High Frequency Active-Clamped Zero-Current Switching Current-Fed Push-Pull Converter for Micro-Converter Applications
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
AGU 2021 Fall Meeting, Virtual, December 13-17, 2021.
Abstract not provided.
A hydrokinetic turbine system for harvesting energy from riverine and tidal sources, including a first floating dock, a marine hydrokinetic turbine mounted on the first floating dock, and a second floating dock. The system further includes a winch assembly mounted on the second floating dock and operationally connected to the first floating dock and a linkage assembly operationally connected to the first floating dock and to the second floating dock. The linkage assembly may be actuated to pull the first floating dock into contact with the second floating dock. The linkage assembly may be actuated to distance the first floating dock from the second floating dock, and the winch assembly may be energized to orient the first floating dock into a position wherein the marine hydrokinetic turbine is above the first floating dock and wherein the winch assembly may be energized to orient the first floating dock into a position wherein the marine hydrokinetic turbine is below the first floating dock.
This work introduces a new current model into the EFIT code for plasma current profile reconstruction. Using this model, edge-localized current density profiles are reconstructed solely from external magnetic measurements. Quantitative comparisons show that edge current profiles obtained with the new current model align closely with those from kinetic equilibrium reconstruction. The new model enables current density reconstruction with fewer diagnostics than kinetic equilibrium reconstruction (Lao et al 1990 Nucl. Fusion 30 1035–49), demonstrating that edge-localized current density information can be obtained from external magnetic measurements only, without the help of kinetic profiles and internal diagnostics, and without using the bootstrap current model. Furthermore, with the constraints of external magnetic and MSE measurements, current profiles in full radius obtained from the new model are in good agreement with the results of kinetic equilibrium reconstruction, which not only improves the efficiency of current reconstruction but also helps avoid possible errors caused by different kinds of diagnoses. Possible applications are also discussed, and a brief analysis of the evolution of the full-radius current density is performed. Noticeable decreases in both the magnitude and gradient of the edge current around the time of ELM bursts are observed. Moreover, analysis of the full radius current density profiles ( ρ N = 0 − 1.0, ρN denotes to square root of the normalized toroidal flux) reveals that as the edge current changes, the inner current also changes following a sinusoidal-like pattern at almost all time slices during four type-I ELMs in discharge 161493. The current evolution in the inner region ( ρ N = 0.2 − 0.6) is synchronized with the boundary region ( ρ N = 0.89 − 1.0), while the intermediate region ( ρ N = 0.6 − 0.89) shows opposite behavior. This sinusoidal-like variations in full-radius current density profile indicates strong core-pedestal coupling, suggesting ELMs significantly affect core plasmas, though current changes manifest differently across radial regions.
The Solid-State Fault Current Limiter (SSCL) is a promising technology that can be applied to utility power delivery systems to address the problem of increasing fault currents associated with load growth. As demand continues to grow, more power is added to utility system either by increasing generator capacity or by adding distributed generators, resulting in higher available fault currents, often beyond the capabilities of the present infrastructure. The SSCL is power-electronics based equipment designed to work with the present utility system to address this problem. The SSCL monitors the line current and dynamically inserts additional impedance into the line in the event of a fault being detected. The SSCL is based on a modular design and can be configured for 5kV through 69kV systems at nominal current ratings of 1000A to 4000A. Results and Findings This report provides the final test results on the development of 15kV class SSCL single phase power stack. The scope of work included the design of the modular standard building block sub-assemblies, the design and manufacture of the power stack and the testing of the power stack for the key functional tests of continuous current capability and fault current limiting action. Challenges and Objectives Solid-State Current Limiter technology impacts a wide spectrum of utility engineering and operating personnel. It addresses the problems associated with load growth both at Transmission and Distribution class networks. The design concept is pioneering in terms of developing the most efficient and compact power electronics equipment for utility use. The initial test results of the standard building blocks are promising. The independent laboratory tests of the power stack are promising. However the complete 3 phase system needs rigorous testing for performance and reliability. Applications, Values, and Use The SSCL is an intelligent power-electronics device which is modular in design and can provide current limiting or current interrupting capabilities. It can be applied to variety of applications from distribution class to transmission class power delivery grids and networks. It can also be applied to single major commercial and industrial loads and distributed generator supplies. The active switching of devices can be further utilized for protection of substation transformers. The stress on the system can be reduced substantially improving the life of the power system. It minimizes the voltage sag by speedy elimination of heavy fault currents and promises to be an important element of the utility power system. DOE Perspective This development effort is now focused on a 15kV system. This project will help mitigate the challenges of increasing available fault current. DOE has made a major contribution in providing a cost effective SSCL designed to integrate seamlessly into the Transmission and Distribution networks of today and the future. Approach SSCL development program for a 69kV SSCL was initiated which included the use of the Super GTO advanced semiconductor device which won the 2007 R&D100 Award. In the beginning, steps were identified to accomplish the economically viable design of a 69kV class Solid State Current Limiter that is extremely reliable, cost effective, and compact enough to be applied in urban transmission. The prime thrust in design and development was to encompass the 1000A and the 3000A ratings and provide a modular design to cover the wide range of applications. The focus of the project was then shifted to a 15kV class SSCL. The specifications for the 15kV power stack are reviewed. The design changes integrated into the 15kV power stack are discussed. In this Technical Update the complete project is summarized followed by a detailed test report. The power stack independent high voltage laboratory test requirements and results are presented. Keywords Solid State Current Limiter, SSCL, Fault Current Limiter, Fault Current Controller, Power electronics controller, Intelligent power-electronics Device, IED
Non-inductive (NI) plasma current start-up and ramp-up is an important research topic for spherical tokamak (ST) based reactors and fusion pilot plant (FPP). For a compact FPP, the OH flux availability is highly restricted due to its compact geometry. Efficient fundamental extraordinary mode (X-I) electron cyclotron heating (ECH) current start-up and ramp-up regime was identified for a reactor-like high toroidal magnetic field range which has more than a hundred times higher current drive efficiency compared to more conventional ECH methods for the relevant start-up temperature range. High current drive efficiency is possible due to the strong X-I fundamental ECH interaction only with unidirectional passing electrons constrained by the wave accessibility conditions. Here, we extend the X-I electron cyclotron current drive (ECCD) investigation to a time dependent model to simulate the non-inductive current ramp-up to 10 MA for the Sustained High-Power Density (SHPD) facility. As the X-I ECCD driven current I EC rises, due to the back EMF driven negative current, the net plasma current Ip rises more slowly with the current resistive time scale. For tokamak confinement time (both L-mode and H-Mode) which tends to rise with I p , a positive feedback results and even with constant applied ECH power, T e0 , I EC , and I p can continue to rise to very high values. However, in a realistic situation, the T e0 rise should saturate due to a number of factors such as enhanced core radiation and increased power loss at high temperature. To simulate this effect, we adopt a maximum T e0 model which would limit the temperature rise to certain T e0 . With this model, we investigated the current ramp-up for various ECH power levels and the maximum T e0 of 15, 20, and 25 keV. We find that while the power required is reduced with increasing T e0 limit due to increased current drive efficiency, the time to reach 10 MA tends to go up due to the reduced plasma resistivity for the higher T e0 limit. We also find for a given Te0 limit, the time to reach 10 MA tends to be reduced by increasing the applied ECH power by over driving the current ramp-up where I EC is driven at significantly higher level than 10 MA. While the current ramp-up time may not be an issue for the steady-state reactor systems, if it is desirable to minimize the current ramp-up time, it is prudent to have a sufficient ECH power for current over-drive and have some T e0 limiting tools such as impurity seeding for enhanced radiation. In conclusion, a well-controlled NI ECH start-up also has a potential of improving the tokamak start-up reliability and avoid run-away electrons while the NI off-axis current drive could enhance MHD stability and plasma performance improvements.
We present the designs of probes for making critical current density (J{sub c}) measurements on anisotropic high-temperature superconducting tapes as a function of field, field orientation, temperature and strain in our 40 mm bore, split-pair 15 T horizontal magnet. Emphasis is placed on the design of three components: the vapour-cooled current leads, the variable temperature enclosure, and the springboard-shaped bending beam sample holder. The vapour-cooled brass critical-current leads used superconducting tapes and in operation ran hot with a duty cycle (D) of ∼0.2. This work provides formulae for optimising cryogenic consumption and calculating cryogenic boil-off, associated with current leads used to make J{sub c} measurements, made by uniformly ramping the current up to a maximum current (I{sub max}) and then reducing the current very quickly to zero. They include consideration of the effects of duty cycle, static helium boil-off from the magnet and Dewar (b{sup ′}), and the maximum safe temperature for the critical-current leads (T{sub max}). Our optimized critical-current leads have a boil-off that is about 30% less than leads optimized for magnet operation at the same maximum current. Numerical calculations show that the optimum cross-sectional area (A) for each current lead can be parameterized by LI{sub max}/A=[1.46D{sup −0.18}L{sup 0.4}(T{sub max}−300){sup 0.25D{sup −{sup 0{sup .{sup 0{sup 9}}}}}}+750(b{sup ′}/I{sub max})D{sup 10{sup −{sup 3I{sub m}{sub a}{sub x}−2.87b{sup ′}}}}]× 10{sup 6}A m{sup −1} where L is the current lead's length and the current lead is operated in liquid helium. An optimum A of 132 mm{sup 2} is obtained when I{sub max} = 1000 A, T{sub max} = 400 K, D = 0.2, b{sup ′} = 0.3 l h{sup −1} and L = 1.0 m. The optimized helium consumption was found to be 0.7 l h{sup −1}. When the static boil-off is small, optimized leads have a boil-off that can be roughly parameterized by: b/I{sub max } ≈ (1.35 × 10{sup −3})D{sup 0.41} l h{sup ‑1} A{sup −1}. A split-current-lead design is employed to minimize the rotation of the probes during the high current measurements in our high-field horizontal magnet. The variable-temperature system is based on the use of an inverted insulating cup that operates above 4.2 K in liquid helium and above 77.4 K in liquid nitrogen, with a stability of ±80 mK to ±150 mK. Uniaxial strains of −1.4% to 1.0% can be applied to the sample, with a total uncertainty of better than ±0.02%, using a modified bending beam apparatus which includes a copper beryllium springboard-shaped sample holder.
Hybrid organic-inorganic block copolymer electrolytes are of interest to enable batteries containing lithium metal anodes. The conductive block is a standard polymer electrolyte of poly(ethylene oxide) and the mechanically rigid block is an inorganic poly(acryloisobutyl polyhedral oligomeric silsesquioxane) polymer. Here, in this paper, we compare a poly(acryloisobutyl polyhedral oligomeric silsesquioxane)-b-poly(ethylene oxide)-b-poly(acryloisobutyl polyhedral oligomeric silsesquioxane) (POSS-PEO-POSS) triblock copolymer and a poly(ethylene oxide)-b- poly(acryloisobutyl polyhedral oligomeric silsesquioxane) (PEO-POSS) diblock copolymer mixed with lithium bis(trifluoromethanesulfonyl)imide salt. We have experimentally measured the limiting current density in lithium symmetric cells containing hybrid organic-inorganic electrolytes at 90 °C. The cells were polarized at a large range of applied current density. The diblock copolymer electrolyte exhibited a clear plateau in cell potential at all current densities below the limiting current density. At low applied current density, the triblock copolymer electrolyte also exhibited a clear plateau in cell potential. At currents approaching the limiting current density, the triblock copolymer electrolyte exhibited an underdamped potential profile. The cell potential did not reach a plateau at current densities above the limiting current in both systems. The diblock and triblock copolymer electrolytes were fully characterized using electrochemical methods to determine the ionic conductivity, cation current fraction, salt diffusion coefficient, and open circuit voltage as a function of salt concentration. Cell potential and salt concentration as functions of position in the cell at various current densities were calculated using Newman's concentrated solution theory. The theoretical limiting current density was calculated to be the current density at which salt is depleted at the cathode. We see quantitative agreement between experimental measurements and theoretical predictions for the limiting current density in the diblock copolymer electrolyte which has an ordered structure at all salt concentrations, while the experimental limiting current density is lower than the theoretical prediction for the triblock copolymer electrolyte, which exhibits a disordered morphology at high salt concentrations.
This project examined the current magnitude and frequency response of 7SJ61 and 7SJ62 SIPROTEC relays. The measured sample frequencies for the 7SJ61 and 7SJS62 relays were 800 and 960 Hz, respectively. The relays were tested at frequencies of up to 1 and 20.16 kHz. Two experiments were run in a lab environment. The first experiment was run at frequencies of up to 1 kHz every 10 Hz. The second one was run at frequencies of up to 20.16 kHz every 200 and 240 Hz (common factors of sample rate frequency) for the 7SJ61 and 7SJ62 SIPROTEC relays, respectively. Both experiments were set at a current magnitude of 0.1 and 0.5 Arms. A testbed with a Relay Test Equipment (RTE) was set to run the experiment at frequencies of up to 1 kHz, while a testbed with a RTE and High Frequency Power Source/ Amplifier (HFPS/A) was set to run at frequencies of up to 20.16 kHz. Currents of 0.1 and 0.5 Arms at different frequencies were connected at Phase A of the relays, and a current of 1 Arms (60 Hz) was connected at Phase B of relays. The 1 Arms current allowed the relays to trip and saved their record events by setting both relays at a definite-time overcurrent protection function. The record events were collected after the 7SJ61 and 7SJ62 relays tripped, and the current magnitude and frequency were plotted. The record events from the relays were collected using the DIGSI® 4 software. The SYNCHROWAVE® Event and MATLAB® software were then used to plot the current magnitude and frequency, respectively, from the relay record events. The current magnitude and frequency were plotted at time and frequency domain, respectively.The 7SJ61 and 7SJ62 relays measured source frequencies of up to 400 and 480 Hz, respectively. The percentage error of frequency for the relays increased after 400 and 480 Hz, respectively. The 7SJ62 relay with 0.1 and 0.5 Arms measured the alias frequency up to 1440 Hz. The 7SJ61 relay with 0.1 and 0.5 Arms measured the alias frequency up to 1000 and 1200 Hz, respectively. At frequencies higher than the alias frequency, the relays measured a DC amplitude current instead of an AC amplitude current. In the DC amplitude current zone, non-desired frequencies were measured by both relays. The current magnitude intensity (dB) for the 7SJ61 and 7SJ62 relays from 1 to 20.16 kHz were plotted. The current magnitude intensity for the 7SJ61 relay decreased up to 2600 and 1200 Hz for 0.5 and 0.1 Arms tests, respectively. However, the current magnitude intensity for the 7SJ62 relay decreased up to 4800 and 2640 Hz for 0.5 and 0.1 Arms tests, respectively. The current magnitude and frequency response study for the 7SJ61 and 7SJ62 relays was performed satisfactorily, observing the source, alias, and non-desired measured frequency zones for both relays.
We have developed a system of differential-output monitors that diagnose current and voltage in the vacuum section of a 20-MA 3-MV pulsed-power accelerator. The system includes 62 gauges: 3 current and 6 voltage monitors that are fielded on each of the accelerator's 4 vacuum-insulator stacks, 6 current monitors on each of the accelerator's 4 outer magnetically insulated transmission lines (MITLs), and 2 current monitors on the accelerator's inner MITL. The inner-MITL monitors are located 6 cm from the axis of the load. Each of the stack and outer-MITL current monitors comprises two separate B-dot sensors, each of which consists of four 3-mm-diameter wire loops wound in series. The two sensors are separately located within adjacent cavities machined out of a single piece of copper. The high electrical conductivity of copper minimizes penetration of magnetic flux into the cavity walls, which minimizes changes in the sensitivity of the sensors on the 100-ns time scale of the accelerator's power pulse. A model of flux penetration has been developed and is used to correct (to first order) the B-dot signals for the penetration that does occur. The two sensors are designed to produce signals with opposite polarities; hence, each current monitor may be regarded as a single detector with differential outputs. Common-mode-noise rejection is achieved by combining these signals in a 50-{Omega} balun. The signal cables that connect the B-dot monitors to the balun are chosen to provide reasonable bandwidth and acceptable levels of Compton drive in the bremsstrahlung field of the accelerator. A single 50-{omega} cable transmits the output signal of each balun to a double-wall screen room, where the signals are attenuated, digitized (0.5-ns/sample), numerically compensated for cable losses, and numerically integrated. By contrast, each inner-MITL current monitor contains only a single B-dot sensor. These monitors are fielded in opposite-polarity pairs. The two signals from a pair are not combined in a balun; they are instead numerically processed for common-mode-noise rejection after digitization. All the current monitors are calibrated on a 76-cm-diameter axisymmetric radial transmission line that is driven by a 10-kA current pulse. The reference current is measured by a current-viewing resistor (CVR). The stack voltage monitors are also differential-output gauges, consisting of one 1.8-cm-diameter D-dot sensor and one null sensor. Hence, each voltage monitor is also a differential detector with two output signals, processed as described above. The voltage monitors are calibrated in situ at 1.5 MV on dedicated accelerator shots with a short-circuit load. Faraday's law of induction is used to generate the reference voltage: currents are obtained from calibrated outer-MITL B-dot monitors, and inductances from the system geometry. In this way, both current and voltage measurements are traceable to a single CVR. Dependable and consistent measurements are thus obtained with this system of calibrated diagnostics. On accelerator shots that deliver 22 MA to a low-impedance z-pinch load, the peak lineal current densities at the stack, outer-MITL, and inner-MITL monitor locations are 0.5, 1, and 58 MA/m, respectively. On such shots the peak currents measured at these three locations agree to within 1%.
The Earth’s magnetosphere is an open dynamic system permanently interacting with the solar wind, i.e., the plasma flow from the Sun. Some plasma processes in the magnetosphere are of spontaneous explosive character, while others develop rather slowly as compared to the characteristic times of plasma particle motion in it. The large-scale current sheet in the magnetotail can be in an almost equilibrium state both in quiet periods and during geomagnetic perturbations, and its variations can be considered quasistatic. Thus, under some conditions, the magnetotail current sheet can be described as an equilibrium plasma system. Its state depends on various parameters, in particular, on those determining the dynamics of charged particles. Knowing the main governing parameters, one can study the structure and properties of the current sheet equilibrium. This work is devoted to the self-consistent modeling of the equilibrium thin current sheet (TCS) of the Earth’s magnetotail, the thickness of which is comparable with the ion gyroradius. The main objective of this work is to examine how the TCS structure depends on the parameters characterizing the particle dynamics and magnetic field geometry. A numerical hybrid self-consistent TCS model in which the tension of magnetic field lines is counterbalanced by the inertia of ions moving through the sheet is constructed. The ion dynamics is considered in the quasi-adiabatic approximation, while the electron motion, in the conductive fluid approximation. Depending on the values of the adiabaticity parameter κ (which determines the character of plasma particle motion) and the dimensionless normal component of the magnetic field b{sub z}, the following two scenarios are considered: (A) the adiabaticity parameter is proportional to the particle energy and b{sub z} = const and (B) the particle energy is fixed and the adiabaticity parameter is proportional to b{sub z}. The structure of the current sheet and particle dynamics in it are studied as functions of the parameters κ and b{sub z}. It is shown that, in scenario A, the current sheet thickness decreases with increasing adiabaticity parameter due to a decrease in the ion gyroradius. Accordingly, the radius of curvature of magnetic field lines decreases, which leads to an increase in the contribution of electron drift currents near the neutral plane z = 0. Numerical simulations demonstrate that current equilibria can exist if the adiabaticity parameter lies in the range 0.05 ≤ κ ≤ 0.7. At κ ∼ 0.7, the contribution of electron drift currents to the total current density is much larger than the contribution of ions and the ion motion becomes chaotic. At larger values of the adiabaticity parameter, no equilibrium solutions were found in the framework of the given one-dimensional model. Therefore, the value κ = 0.7 corresponds to the upper applicability limit of the quasi-adiabatic model of the current sheet. In scenario B, an increase in the parameter κ leads to the appearance of a large number of quasi-trapped ions in the current sheet, due to which the current sheet thickens and the amplitude of the current density decreases. As a result, equilibrium solutions exist in a much narrower range of the adiabaticity parameter, 0.05≤ κ ≤ 0.25. Consequences of the existence of parametric boundaries of equilibrium solutions for the TCS under actual geomagnetic conditions are discussed.
This article describes the development of a direct-current (dc) superconducting transformer system for the high current test of superconducting cables. The transformer consists of a core-free 10 464 turn primary solenoid which is enclosed by a 6.5 turn secondary. The transformer is designed to deliver a 50 kA dc secondary current at a dc primary current of about 50 A. The secondary current is measured inductively using two toroidal-wound Rogowski coils. The Rogowski coil signal is digitally integrated, resulting in a voltage signal that is proportional to the secondary current. This voltage signal is used to control the secondary current using a feedback loop which automatically compensates for resistive losses in the splices to the superconducting cable samples that are connected to the secondary. The system has been commissioned up to 28 kA secondary current. The reproducibility in the secondary current measurement is better than 0.05% for the relevant current range up to 25 kA. The drift in the secondary current, which results from drift in the digital integrator, is estimated to be below 0.5 A/min. The system's performance is further demonstrated through a voltage-current measurement on a superconducting cable sample at 11 T background magnetic field. The superconducting transformer system enables fast, high resolution, economic, and safe tests of the critical current of superconducting cable samples.
We present an approach for minimizing the critical current for the magnetization switching in magnetic tunnel junctions by optimizing the spatial distribution of the current density. We show that such a minimization is possible because critical current is determined by the condition of making one of the magnetization eigenstates grow in time. The excitation of the eigenstates is enhanced when the spatial distributions of the eigenstates and current density overlap. Critical current can be viewed as a functional of the current density spatial distribution and it can be minimized by optimizing this distribution. Such an optimization results in a major reduction of the critical current and increase of the switching efficiency, viz. the ratio between the energy barrier and critical current. The minimized critical current increases approximately linearly with the magnetic tunnel junction size, which is much slower than critical current for the case of a uniform current density. The optimized efficiency can be approximately a constant with respect to the magnetic tunnel junction size, which is much higher than the efficiency for the uniform current density. Additional optimization can be achieved by spatially modulating the material parameters, e.g., the saturation magnetization. The presented approach and obtained scaling of the critical current and efficiency offers opportunities for the magnetic tunnel junction optimization.
In many of the publications, over 50 per year for the last five years, the Poole-Frenkel-effect (PFE) is identified or suggested as dominating current mechanism to explain measured current–electric field dependencies in metal-insulator-metal (MIM) thin film stacks. Very often, the insulating thin film is a metal oxide as this class of materials has many important applications, especially in information technology. In the overwhelming majority of the papers, the identification of the PFE as dominating current mechanism is made by the slope of the current–electric field curve in the so-called Poole-Frenkel plot, i.e., logarithm of current density, j, divided by the applied electric field, F, versus the square root of that field. This plot is suggested by the simplest current equation for the PFE, which comprises this proportionality (ln(j/F) vs. F{sup 1/2}) leading to a straight line in this plot. Only one other parameter (except natural constants) may influence this slope: the optical dielectric constant of the insulating film. In order to identify the importance of the PFE simulation studies of the current through MIM stacks with thin insulating films were performed and the current–electric field curves without and with implementation of the PFE were compared. For the simulation, an advanced current model has been used combining electronic carrier injection/ejection currents at the interfaces, described by thermionic emission, with the carrier transport in the dielectric, described by drift and diffusion of electrons and holes in a wide band gap semiconductor. Besides the applied electric field (or voltage), many other important parameters have been varied: the density of the traps (with donor- and acceptor-like behavior); the zero-field energy level of the traps within the energy gap, this energy level is changed by the PFE (also called internal Schottky effect); the thickness of the dielectric film; the permittivity of the dielectric film simulating different oxide materials; the barriers for electrons and holes at the interfaces simulating different electrode materials; the temperature. The main results and conclusions are: (1) For a single type of trap present only (donor-like or acceptor-like), none of the simulated current density curves shows the expected behavior of the PFE and in most cases within the tested parameter field the effect of PFE is negligibly small. (2) For both types of traps present (compensation) only in the case of exact compensation, the expected slope in the PF-plot was nearly found for a wider range of the applied electric field, but for a very small range of the tested parameter field because of the very restricting additional conditions: first, the quasi-fermi level of the current controlling particle (electrons or holes) has to be 0.1 to 0.5 eV closer to the respective band limit than the zero-field energy level of the respective traps and, second, the compensating trap energy level has to be shallow. The conclusion from all these results is: the observation of the PFE as dominating current mechanism in MIM stacks with thin dielectric (oxide) films (typically 30 nm) is rather improbable!.
This paper reports the results of modelling of the current-voltage characteristics (I-V) of a planar mid-wave Mercury Cadmium Telluride photodiode in a gate controlled diode experiment. It is reported that the diode exhibits nearly ideal I-V characteristics under the optimum surface potential leading to the minimal surface leakage current. Deviations from the optimum surface potential lead to non ideal I–V characteristics, indicating a strong relationship between the ideality factor of the diode with its surface leakage current. Diode's I–V characteristics have been modelled over a range of gate voltages from −9 V to −2 V. This range of gate voltages includes accumulation, flat band, and depletion and inversion conditions below the gate structure of the diode. It is shown that the I–V characteristics of the diode can be very well described by (i) thermal diffusion current, (ii) ohmic shunt current, (iii) photo-current due to background illumination, and (iv) excess current that grows by the process of avalanche multiplication in the gate voltage range from −3 V to −5 V that corresponds to the optimum surface potential. Outside the optimum gate voltage range, the origin of the excess current of the diode is associated with its high surface leakage currents. It is reported that the ohmic shunt current model applies to small surface leakage currents. The higher surface leakage currents exhibit a nonlinear shunt behaviour. It is also shown that the observed zero-bias dynamic resistance of the diode over the entire gate voltage range is the sum of ohmic shunt resistance and estimated zero-bias dynamic resistance of the diode from its thermal saturation current.
Abstract Singular currents typically appear on rational surfaces in non-axisymmetric ideal magnetohydrodynamic (MHD) equilibria with a continuum of nested flux surfaces and a continuous rotational transition. These currents have two components: a surface current (Dirac δ -function in flux surface labeling) that prevents the formation of magnetic islands, and an algebraically divergent Pfirsch–Schlüter current density when a pressure gradient is present across the rational surface. On flux surfaces adjacent to the rational surface, the traditional treatment gives the Pfirsch–Schlüter current density scaling as J ∼ 1 / Δ ι , where Δ ι is the difference of the rotational transform relative to the rational surface. If the distance s between flux surfaces is proportional to Δ ι , the scaling relation J ∼ 1 / Δ ι ∼ 1 / s will lead to a paradox that the Pfirsch–Schlüter current is not integrable. In this work, we investigate this issue by considering the pressure-gradient-driven singular current in the Hahm–Kulsrud–Taylor problem, which is a prototype for singular currents arising from resonant magnetic perturbations. We show that not only the Pfirsch–Schlüter current density but also the diamagnetic current density are divergent as ∼ 1 / Δ ι . However, due to the formation of a Dirac δ -function current sheet at the rational surface, the neighboring flux surfaces are strongly packed with s ∼ ( Δ ι ) 2 . Consequently, the singular current density J ∼ 1 / s , making the total current finite, thus resolving the paradox. Furthermore, the strong packing of flux surfaces causes a steepening of the pressure gradient near the rational surface, with ∇ p ∼ d p / d s ∼ 1 / s . In general non-axisymmetric MHD equilibrium, contrary to Grad’s conjecture that the pressure profile is flat around densely distributed rational surfaces, our result suggests a pressure profile that densely steepens around them.
Marine and hydrokinetic (MHK) energy, including ocean waves, tidal current, ocean current and river current, has been recognized as a promising power source due to its full-day availability and high energy potential. At this stage, ocean current energy, tidal energy and ocean wave energy are currently the most competitive sourves among all the categories of MHK. The state of art MHK energy harvesting technology mainly focus on harvesting either ocean wave energy or current energy, but not both. However, a significant amount of ocean waves and tidal/ ocean current coexist in many sites and traditional devices that harvest from a single form of MHK energy, cannot make full use of the coexisting ocean energy. Furthermore, MHK energy harvesting devices need to advance to be cost-effective and competitive with other energy sources. This is difficult to achieve. Ocean wave excitation is irregular, which means that ocean wave height and wave periods are unpredictable and excitation forces on energy harvesting devices can have large variance in amplitude and frequency. Such problems/ restrictions can be possibly addressed by the concept of a hybrid energy converter. In this sense, a hybrid wave-current ocean energy conveter (HWCEC) that simutaneously harvests energy from current and wave with one single power takeoff (PTO) is designed.The wave energy is extracted through relative heaving motion between a floating buoy and a submerged second body, while the current energy is extracted using a marine current turbine (MCT). Energy from both sources are integrated by a hybrid PTO whose concept is based on a mechanical motion rectifier (MMR). In this study, different working modes are investigated together with switching criteria.Simulations were conducted with hydrodynamic coefficients obtained from computational fluid dynamics analysis and boundary element method. Tank tests were conducted for a HWCEC under coexisting wave and current inputs. For comparison, separate baseline tests of a turbine and a two-body point absorber, each acting in isolation, are conducted. Experimental results validate the dynamic modeling and show that a HWCEC can increase the output power with a range between 29-87 percent over either current turbine and wave energy converter acting individually, and it can reduce by up to 70 percent the peak-to-average power ratio compared with the wave energy converter on the tested conditions.Such results demonstrate the potential of the HWCEC as an efficient and cost-effective design.