Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Magnetic Measurements of HL-LHC AUP Cryo-Assemblies at Fermilab

LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test facility. The ~10 m - long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis location, and for variations in axis position and local field profile. A multi-probe, PCB-based rotating coil and Single Stretched Wire system are employed for these measurements. To accurately determine rotating coil location and angles within the cold mass, a laser tracker is utilized to record multiple targets at one end of the probe. This paper describes the measurements, probes/equipment, and techniques used to perform the necessary characterization of the cold mass.

43 PARTICLE ACCELERATORS↗

Cryo nanomanipulator probe with integrated gas injection

A probe assembly for use with a charged particle instrument includes an elongate body having a proximal end for positioning outside of a charged particle instrument enclosed environment, a distal end for positioning within the enclosed environment and a longitudinal axis. A port interface is located on the body between the proximal and distal ends, and is coupleable to a nanomanipulator system of the charged particle instrument. A probe needle is positioned at a distal end of the body and is selectively positionable from outside the enclosed environment to contact a specimen within the enclosed environment. At least one gas injection needle is adjustably positioned near the probe needle. The gas injection needle is connectable to a source of pressurized gas to selectively inject gas in the area of the probe needle within the enclosed environment.

Perea, Daniel E.↗

Cryoplasty Versus Conventional Balloon Angioplasty of the Femoropopliteal Artery in Diabetic Patients: Long-Term Results from a Prospective Randomized Single-Center Controlled Trial

The purpose of this study was to investigate the immediate and long-term results of cryoplasty versus conventional balloon angioplasty in the femoropopliteal artery of diabetic patients. Fifty diabetic patients (41 men, mean age 68 years) were randomized to cryoplasty (group CRYO; 24 patients with 31 lesions) or conventional balloon angioplasty (group COBA; 26 patients with 34 lesions) of the femoropopliteal artery. Technical success was defined as <30% residual stenosis without any adjunctive stenting. Primary end points included technical success, primary patency, binary in-lesion restenosis (>50%), and freedom from target lesion recanalization. Cox proportional hazards regression analysis was performed to adjust for confounding factors of heterogeneity. In total, 61.3% (19 of 31) in group CRYO and 52.9% (18 of 34) in group COBA were de novo lesions. More than 70% of the lesions were Transatlantic Inter-Society Consensus (TASC) B and C in both groups, and 41.4% of the patients in group CRYO and 38.7% in group COBA suffered from critical limb ischemia. Immediate technical success rate was 58.0% in group CRYO versus 64.0% in group COBA (p = 0.29). According to 3-year Kaplan-Meier estimates, there were no significant differences with regard to patient survival (86.8% in group CRYO vs. 87.0% in group COBA, p = 0.54) and limb salvage (95.8 vs. 92.1% in groups CRYO and COBA, respectively, p = 0.60). There was a nonsignificant trend of increased binary restenosis in group CRYO (hazard ratio [HR] 1.3; 95% CI 0.6-2.6, p = 0.45). Primary patency was significantly lower in group CRYO compared with group COBA (HR 2.2; 95% CI 1.1-4.3, p = 0.02). Significantly more repeat intervention events because of recurrent symptoms were required in group CRYO (HR 2.5; 95% CI 1.2-5.3, p = 0.01). Cryoplasty was associated with lower primary patency and more clinically driven repeat procedures after long-term follow-up compared with conventional balloon angioplasty.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extracellular filaments revealed by affinity capture cryogenic-electron tomography

Cryogenic-electron tomography (cryo-ET) has provided an unprecedented glimpse into the nanoscale architecture of cells by combining cryogenic preservation of biological structures with electron tomography. Micropatterning of extracellular matrix proteins is increasingly used as a method to prepare adherent cell types for cryo-ET as it promotes optimal positioning of cells and subcellular regions of interest for vitrification, cryo-focused ion beam (cryo-FIB) milling, and data acquisition. Here we demonstrate a micropatterning workflow for capturing minimally adherent cell types, human T cells and Jurkat cells, for cryo-FIB and cryo-ET. Our affinity capture system facilitated the nanoscale imaging of Jurkat cells, revealing extracellular filamentous structures. It improved workflow efficiency by consistently producing grids with a sufficient number of well-positioned cells for an entire cryo-FIB session. Affinity capture can be extended to facilitate high-resolution imaging of other adherent and non-adherent cell types with cryo-ET.

Biochemistry↗

Radiochemistry as a (rho)R Diagnostic with the RAGS Gas Collection System

Radiochemical diagnostic techniques such as gas-phase capsule debris analysis may prove to be successful methods for establishing the success or failure of ignition experiments at the National Ignition Facility (NIF). Samples in the gas phase offer the most direct method of collection by simply pumping out the large target chamber following a NIF shot. The target capsules will be prepared with dopants which will produce radioactive noble gas isotopes upon activation with neutrons. We have designed and constructed the Radchem Apparatus for Gas Sampling (RAGS) in order to collect post-shot gaseous samples for NIF capsule diagnostics. The design of RAGS incorporates multiple stages intended to purify, transfer, and count the radioactive decays from gaseous products synthesized in NIF experiments. At the moment the dopant of choice is {sup 124}Xe, which will undergo (n,{gamma}) and (n, 2n) reactions to produce {sup 125}Xe and {sup 123}Xe. The half-lives of each are on the order of multiple hours and are suitable for long-term gamma-counting. These isotopes and the rest of the gases evolved in a NIF shot will be drawn through the NIF turbo pumps, past the temporarily shuttered cryo pumps (to aid our collection efficiency), and towards the first main portion of the RAGS system: the pre-cleaner. The pre-cleaner will consist of a water removal system, a series of heated getter cartridges to remove most other impurities such as N{sub 2}, O{sub 2}, CO{sub 2}, etc., and a residual gas analyzer (RGA) to monitor vacuum quality. The noble gases will flow through the precleaner and into the second stage of the system: the cryo collector. This cryo collector consists of a main cryo head for noble gas collection which will operate for approximately five minutes post-shot. Afterwards a valve will close and isolate the pre-cleaner, while the cryo head warms to release the Xe gas to one of two locations - either a second cryo station for in-situ gamma counting, or to a small cooled gas bottle for removal and counting. Additional capabilities of the RAGS system include a noble gas calibration apparatus attached to the NIF target chamber, which will be operated hours pre-shot to determine collection efficiency through the whole RAGS system via the signal detected from the RGA. Also it is possible there will be the addition of a helium puff system to drive the Xe through the pre-cleaner and collection stations. It is also likely that multiple cryo collection stations will be built into the system in the future to fractionate and collect other noble gases such as Kr, Ar, and possibly Ne. A prototype pre-cleaner has been built at Lawrence Berkeley National Laboratory (LBNL) and is in the testing phases. The information learned in this testing will help collaborators at Sandia National Laboratory that are building and delivering the systems that will be deployed at NIF. The LBNL testing so far has demonstrated that radioactive fission gases can be flowed through the system with and without carrier gases of air and/or He, and the activity can be collected on an activated charcoal sample. Further testing in the upcoming months will hopefully yield more information about any presence of Xe in the water removed from the system, and commissioning of a small cryo cooler as well.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conjugate Multimode Heat Transfer Analysis of Cryogenic EXLO Manipulation

Abstract In this study, a conjugate radiation/conduction multimode heat transfer analysis of cryogenic focused ion beam (FIB) milling steps necessary for producing ex situ lift out specimens under cryogenic conditions (cryo-EXLO) is performed. Using finite volume for transient heat conduction and enclosure theory for radiation heat transfer, the analysis shows that as long as the specimen is attached or touching the FIB side wall trenches, the specimen will remain vitreous indefinitely, while actively cooled at liquid nitrogen (LN2) temperatures. To simulate the time needed to perform a transfer step to move the bulk sample containing the FIB-thinned specimen from the cryo-FIB to the cryo-EXLO cryostat, the LN2 temperature active cooling is turned off after steady-state conditions are reached and the specimen is monitored over time until the critical devitrification temperature is reached. Under these conditions, the sample will remain vitreous for >3 min, which is more than enough time needed to perform the cryo-transfer step from the FIB to the cryostat, which takes only ∼10 s. Cryo-transmission electron microscopy images of a manipulated cryo-EXLO yeast specimen prepared with cryo-FIB corroborates the heat transfer analysis.

Materials Science↗

Cryogenic EBSD reveals structure of directionally solidified ice–polymer composite

Despite considerable research efforts on directionally solidified or freeze-cast materials in recent years, little fundamental knowledge has been gained that links model with experiment. In this contribution, the cryogenic characterization of directionally solidified polymer solutions illustrates, how powerful cryo-scanning electron microscopy combined with electron backscatter diffraction is for the structural characterization of ice–polymer composite materials. Under controlled sublimation, the freeze-cast polymer scaffold structure is revealed and imaged with secondary electrons. Electron backscatter diffraction fabric analysis shows that the ice crystals, which template the polymer scaffold and create the lamellar structure, have a-axes oriented parallel to the direction of solidification and the c-axes perpendicular to it. These results indicate the great potential of both cryo-scanning electron microscopy and cryo-electron backscatter diffraction in gaining fundamental knowledge of structure–property–processing correlations. - Highlights: • Cryo-SEM of freeze-cast polymer solution reveals an ice-templated structure. • Cryo-EBSD reveals the ice crystal a-axis to parallel the solidification direction. • The honeycomb-like polymer phase favors columnar ridges only on one side. • Combining cryo-SEM with EBSD links solidification theory with experiment.

36 MATERIALS SCIENCE↗

Cryogenic electron tomography by the numbers: Charting underexplored lineages in structural cell biology

Imaging cells and their interactions across the whole biosphere with molecular-scale resolution is key for understanding structure–function relations. Cryogenic electron tomography (cryo-ET) is a powerful method for obtaining this critical information. However, cryo-ET studies are challenging and often limited to a small number of cell types per study. Here, we collate cryo-ET data from hundreds of cells and tissues across the biosphere to i) identify emerging methodological trends, ii) pinpoint strategies to reduce imaging time and costs, iii) quantitatively compare methods for cell freezing and sectioning, and iv) census cryo-ET species coverage across all domains of life. Comparing the fraction of cellular material within a single lamella across all domains of life reveals an order of magnitude difference between eukaryotes (1%) compared to bacteria (9%) and archaea (14%). We calculate the fraction of cellular material which can be imaged using distinct sectioning methods on multicellular communities and tissues—identifying serial lift-out as a powerful approach for obtaining more complete cellular depictions. Finally, we show that the biodiversity of current cryo-ET studies is 2 to 3 orders of magnitude lower than in sequence libraries and 4 to 5 lower than the total predicted on Earth. Our analyses reveal major evolutionary lineages which remain critically understudied and highlight where future cryo-ET research would be most impactful.

HPF↗

Structural determination of a full-length plant cellulose synthase informed by experimental and in silico methods

Three-dimensional structure determination and prediction of proteins with intrinsically disordered regions, unstructured regions, conformational flexibility, and lacking homologous structures are challenging. We previously predicted and refined an in silico structure of a plant cellulose synthase from cotton (GhCESA1), and more recently, cryo-electron microscopy (cryo-EM) has resolved a majority of the lengths of two CESA structures from poplar (PttCESA8) and cotton (GhCESA7). However, 26–30% of these cryo-EM structures remain unresolved, including the N-terminal domain, half of the class-specific region, the gating loop region, and the C-terminal domain. Here, we describe the generation and evaluation of a full-length hybrid GhCESA1 model based on this cryo-EM PttCESA8 structure, with unresolved regions completed using this in silico refined GhCESA1 model. All-atom molecular dynamics simulations and subsequent energy minimizations were performed for the in silico and hybrid GhCESA1 models in a lipid bilayer-water-ion environment, and structural stability, dynamics, energetics, contacts, and quality were evaluated. The unresolved regions were found to be the most dynamic, in agreement with their poor electron density with cryo-EM. The hybrid model exhibited a higher total secondary structure content, more favorable intra-protein and protein-lipid interaction energies, and improved quality metrics. Moreover, hydrogen bonding was revealed to be a primary mechanism for intra-protein and protein-lipid contacts. These results demonstrate that in silico structure prediction and refinement may be useful to augment experimental structure determination, especially for disordered and unstructured regions. Furthermore, this hybrid model can serve as a steppingstone to derive full-length homology models of other CESAs found in more experimentally tractable organisms.

59 BASIC BIOLOGICAL SCIENCES↗

Long helical filaments are not seen encircling cells in electron cryotomograms of rod-shaped bacteria

Highlights: {yields} No long helical filaments are seen near or along rod-shaped bacterial inner membranes by electron cryo-tomography. {yields} Electron cryo-tomography has the resolution to detect single filaments in vivo. -- Abstract: How rod-shaped bacteria form and maintain their shape is an important question in bacterial cell biology. Results from fluorescent light microscopy have led many to believe that the actin homolog MreB and a number of other proteins form long helical filaments along the inner membrane of the cell. Here we show using electron cryotomography of six different rod-shaped bacterial species, at macromolecular resolution, that no long (>80 nm) helical filaments exist near or along either surface of the inner membrane. We also use correlated cryo-fluorescent light microscopy (cryo-fLM) and electron cryo-tomography (ECT) to identify cytoplasmic bundles of MreB, showing that MreB filaments are detectable by ECT. In light of these results, the structure and function of MreB must be reconsidered: instead of acting as a large, rigid scaffold that localizes cell-wall synthetic machinery, moving MreB complexes may apply tension to growing peptidoglycan strands to ensure their orderly, linear insertion.

60 APPLIED LIFE SCIENCES↗

Identification and demonstration of roGFP2 as an environmental sensor for cryogenic correlative light and electron microscopy

Cryogenic correlative light and electron microscopy (cryo-CLEM) seeks to leverage orthogonal information present in two powerful imaging modalities. While recent advances in cryogenic electron microscopy (cryo-EM) allow for the visualization and identification of structures within cells at the nanometer scale, information regarding the cellular environment, such as pH, membrane potential, ionic strength, etc., which influences the observed structures remains absent. Fluorescence microscopy can potentially be used to reveal this information when specific labels, known as fluorescent biosensors, are used, but there has been minimal use of such biosensors in cryo-CLEM to date. Here we demonstrate the applicability of one such biosensor, the fluorescent protein roGFP2, for cryo-CLEM experiments. At room temperature, the ratio of roGFP2 emission brightness when excited at 425 nm or 488 nm is known to report on the local redox potential. When samples containing roGFP2 are rapidly cooled to 77 K in a manner compatible with cryo-EM, the ratio of excitation peaks remains a faithful indicator of the redox potential at the time of freezing. Using purified protein in different oxidizing/reducing environments, we generate a calibration curve which can be used to analyze in situ measurements. As a proof-of-principle demonstration, we investigate the oxidation/reduction state within vitrified Caulobacter crescentus cells. The polar organizing protein Z (PopZ) localizes to the polar regions of C. crescentus where it is known to form a distinct microdomain. Finally, by expressing an inducible roGFP2-PopZ fusion we visualize individual microdomains in the context of their redox environment.

59 BASIC BIOLOGICAL SCIENCES↗

Scattering-type scanning near-field optical microscopy with Akiyama piezo-probes

Recent developments of the scattering-type scanning near-field optical microscope at cryogenic temperatures (cryogenic s-SNOM or cryo-SNOM) have led to many breakthroughs in the studies of low energy excitations in quantum materials. However, the simultaneous demands on vibration isolation, low base temperature, precise nano-positioning, and optical access make the construction of a cryo-SNOM a daunting task. Adding to the overhead space required for a cryo-SNOM is the atomic force microscopy control, which predominantly utilizes a laser-based detection scheme for determining the cantilever tapping motion. In this work, we provide an alternative and straightforward route to performing s-SNOM using metal-coated Akiyama probes, where the cantilever tapping motion is detected through a piezoelectric signal. We show that the Akiyama-based cryo-SNOM attains high spatial resolution, good near-field contrast, and is able to perform imaging with a significantly more compact system compared to other cryo-SNOM implementations. Our results firmly establish the potential of s-SNOM based on self-sensing piezo-probes, which can easily accommodate far-infrared wavelengths and high magnetic fields in the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved cryogenic electron tomography for the study of transient cellular processes

Cryogenic electron tomography (cryo-ET) is the highest resolution imaging technique applicable to the life sciences, enabling sub-nanometer visualization of specimens preserved in their near native states. The rapid plunge freezing process used to prepare samples lends itself to time-resolved studies, which researchers have pursued for in vitro samples for decades. Here, we focus on developing a freezing apparatus for time-resolved studies in situ. The device mixes cellular samples with solution-phase stimulants before spraying them directly onto an electron microscopy grid that is transiting into cryogenic liquid ethane. By varying the flow rates of cell and stimulant solutions within the device, we can control the reaction time from tens of milliseconds to over a second prior to freezing. In a proof-of-principle demonstration, the freezing method is applied to a model bacterium, Caulobacter crescentus, mixed with an acidic buffer. Through cryo-ET we resolved structural changes throughout the cell, including surface-layer protein dissolution, outer membrane deformation, and cytosolic rearrangement, all within 1.5 seconds of reaction time. This new approach, Time-Resolved cryo-ET (TR-cryo-ET), enhances the capabilities of cryo-ET by incorporating a sub-second temporal axis and enables the visualization of induced structural changes at the molecular, organelle, or cellular level.

59 BASIC BIOLOGICAL SCIENCES↗

Soft matter and nanomaterials characterization by cryogenic transmission electron microscopy

Soft matter has historically been an unlikely candidate for investigation by electron microscopy techniques due to damage by the electron beam as well as inherent instability under a high vacuum environment. Characterization of soft matter has often relied on ensemble-scattering techniques. The recent development of cryogenic transmission electron microscopy (cryo-TEM) provides the soft matter community with an exciting opportunity to probe the structure of soft materials in real space. Cryo-TEM reduces beam damage and allows for characterization in a native, frozen-hydrated state, providing direct visual representation of soft structure. This article reviews cryo-TEM in soft materials characterization and illustrates how it has provided unique insights not possible by traditional ensemble techniques. Soft matter systems that have benefited from the use of cryo-TEM include biological-based “soft” nanoparticles (e.g., viruses and conjugates), synthetic polymers, supramolecular materials as well as the organic–inorganic interface of colloidal nanoparticles. We conclude that while many challenges remain, such as combining structural and chemical analyses; the opportunity for soft matter research to leverage newly developed cryo-TEM techniques continues to excite.

36 MATERIALS SCIENCE↗