Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Two-phase flow numerical analysis of electrode geometry for alkaline water electrolyzers

Hydrogen is a promising component of a future energy-secure and efficient economy, but its competitiveness depends on reducing production costs. One strategy is to operate alkaline water electrolyzers at higher current densities to increase output. However, this intensifies performance losses due to gas bubble accumulation, which blocks transport pathways and deactivates electrochemically active surfaces. Enhancing bubble evacuation through electrode design is therefore essential. Previous studies have explored various approaches — such as modifying surface morphology, applying sonication or pressure modulation, and introducing surfactants — but these efforts have addressed a limited range of conditions due to the complexity of two-phase flow and electrode geometries. Experiments have also largely been focused on either cell level improvements, which lack the information necessary to isolate each contributing factor, or on modified geometries that are not relevant to practical cell operation. From a modeling perspective, conventional Eulerian multiphase models do not track the complex gas–liquid interfacial dynamics and often neglect surface tension and contact angle effects, reducing their predictive accuracy. To provide insights on the effects of different electrode geometries on the performance of alklaine water electrolyzers this work employs an immersed boundary volume-of-fluid method to simulate bubble behavior in 3D porous electrodes. Multiple base electrode geometries, typically used in practice, with varying porosity are evaluated under a constant surface gas generation rate. Simulation data is analyzed to quantify electrode gas coverage, bubble size dynamics and other relevant metrics. Results show that porosity strongly influences bubble accumulation on electrode surfaces, with higher porosity reducing gas coverage, and its not strictly dependent on the electrode geometry. However, the electrode’s base geometry significantly affects gas accumulation at the separator gap, independent of porosity. A foam electrode geometry resulted in the lowest gas coverage of all electrodes with a median volumetric gas coverage of 11%, but at the cost of a 70% reduction in active area compared with the largest surface area electrode, while gyroid electrodes showed the best trade-off between gas coverage, particularly at the separator surface, and electrochemically active area. In conclusion, the results highlight the need for holistic electrode design strategies.

Alkaline↗

Postoperative Proton Radiotherapy for Localized and Locoregional Breast Cancer: Potential for Clinically Relevant Improvements?

Purpose: To study the potential reduction of dose to organs at risk (OARs) with intensity-modulated proton radiotherapy (IMPT) compared with intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) photon radiotherapy for left-sided breast cancer patients. Methods and Materials: Comparative treatment-planning was performed using planning computed tomography scans of 20 left-sided breast cancer patients. For each patient, three increasingly complex locoregional volumes (planning target volumes [PTVs]) were defined: whole breast (WB) or chest wall (CW) = (PTV1), WB/CW plus medial-supraclavicular (MSC), lateral-supraclavicular (LSC), and level III axillary (AxIII) nodes = (PTV2) and WB/CW+MSC+LSC+AxIII plus internal mammary chain = (PTV3). For each patient, 3D-CRT, IMRT, and IMPT plans were optimized for PTV coverage. Dose to OARs was compared while maintaining target coverage. Results: All the techniques met the required PTV coverage except the 3D-CRT plans for PTV3-scenario. All 3D-CRT plans for PTV3 exceeded left-lung V20. IMPT vs. 3D-CRT: significant dose reductions were observed for all OARs using IMPT for all PTVs. IMPT vs. IMRT: For PTV2 and PTV3, low (V5) left lung and cardiac doses were reduced by a factor >2.5, and cardiac doses (V22.5) were by a factor of >20 lower with IMPT compared with IMRT. Conclusions: When complex-target irradiation is needed, 3D-CRT often compromises the target coverage and increases the dose to OARs; IMRT can provide better results but will increase the integral dose. The benefit of IMPT is based on improved target coverage and reduction of low doses to OARs, potentially reducing the risk of late-toxicity. These results indicate a potential role of proton-radiotherapy for extended locoregional irradiation in left breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole Brain Radiotherapy With Hippocampal Avoidance and Simultaneous Integrated Boost for 1-3 Brain Metastases: A Feasibility Study Using Volumetric Modulated Arc Therapy

Purpose: To evaluate the feasibility of using volumetric modulated arc therapy (VMAT) to deliver whole brain radiotherapy (WBRT) with hippocampal avoidance and a simultaneous integrated boost (SIB) for one to three brain metastases. Methods and Materials: Ten patients previously treated with stereotactic radiosurgery for one to three brain metastases underwent repeat planning using VMAT. The whole brain prescription dose was 32.25 Gy in 15 fractions, and SIB doses to brain metastases were 63 Gy to lesions >=2.0 cm and 70.8 Gy to lesions <2.0 cm in diameter. The mean dose to the hippocampus was kept at <6 Gy{sub 2}. Plans were optimized for conformity and target coverage while minimizing hippocampal and ocular doses. Plans were evaluated on target coverage, prescription isodose to target volume ratio, conformity number, homogeneity index, and maximum dose to prescription dose ratio. Results: Ten patients had 18 metastases. Mean values for the brain metastases were as follows: conformity number = 0.73 +- 0.10, target coverage = 0.98 +- 0.01, prescription isodose to target volume = 1.34 +- 0.19, maximum dose to prescription dose ratio = 1.09 +- 0.02, and homogeneity index = 0.07 +- 0.02. For the whole brain, the mean target coverage and homogeneity index were 0.960 +- 0.002 and 0.39 +- 0.06, respectively. The mean hippocampal dose was 5.23 +- 0.39 Gy{sub 2}. The mean treatment delivery time was 3.6 min (range, 3.3-4.1 min). Conclusions: VMAT was able to achieve adequate whole brain coverage with conformal hippocampal avoidance and radiosurgical quality dose distributions for one to three brain metastases. The mean delivery time was under 4 min.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying Interobserver Variation in Target Definition in Palliative Radiotherapy

Purpose: To describe the degree of interobserver and intraobserver variability in target and field definition when using three-dimensional (3D) volume- vs. two-dimensional (2D) field-based planning. Methods and Materials: Standardized case scenario and diagnostic imaging for 9 palliative cases (3 bone metastases, 3 palliative lung cancer, and 3 abdominal pelvis soft-tissue disease) were presented to 5 study radiation oncologists. After a decision on what the intended anatomic target should be, observers created two sets of treatment fields, first using a 2D field-based and then a 3D volume-based planning approach. Percent overlap, under-coverage, and over-coverage were used to describe interobserver and intraobserver variations in target definition. Results: The degree of interobserver variation for 2D and 3D planning was similar with a degree of overlap of 76% (range, 56%-85%) and 74% (range, 55%-88%), respectively. When comparing the treatment fields defined by the same observer using the two different planning methods, the mean degree of overlap was 78%; over-coverage, 22%; and under-coverage, 41%. There was statistically significantly more under-coverage when field-based planning was used for bone metastases (33%) vs. other anatomic sites (16%) (p = 0.02). In other words, 2D planning is more likely to result in geographic misses in bone metastases compared with other areas. Conclusions: In palliative radiotherapy clinically significant interobserver and intraobserver variation existed when using both field- and volume-based planning approaches. Strategies that would reduce this variability deserve further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the Impact of Immediate Reconstruction in Postmastectomy Radiation: A Large, Dose-Volume Histogram-Based Analysis

Purpose: To assess the impact of immediate breast reconstruction on postmastectomy radiation (PMRT) using dose-volume histogram (DVH) data. Methods and Materials: Two hundred forty-seven women underwent PMRT at our center, 196 with implant reconstruction and 51 without reconstruction. Patients with reconstruction were treated with tangential photons, and patients without reconstruction were treated with en-face electron fields and customized bolus. Twenty percent of patients received internal mammary node (IMN) treatment. The DVH data were compared between groups. Ipsilateral lung parameters included V20 (% volume receiving 20 Gy), V40 (% volume receiving 40 Gy), mean dose, and maximum dose. Heart parameters included V25 (% volume receiving 25 Gy), mean dose, and maximum dose. IMN coverage was assessed when applicable. Chest wall coverage was assessed in patients with reconstruction. Propensity-matched analysis adjusted for potential confounders of laterality and IMN treatment. Results: Reconstruction was associated with lower lung V20, mean dose, and maximum dose compared with no reconstruction (all P<.0001). These associations persisted on propensity-matched analysis (all P<.0001). Heart doses were similar between groups (P=NS). Ninety percent of patients with reconstruction had excellent chest wall coverage (D95 >98%). IMN coverage was superior in patients with reconstruction (D95 >92.0 vs 75.7%, P<.001). IMN treatment significantly increased lung and heart parameters in patients with reconstruction (all P<.05) but minimally affected those without reconstruction (all P>.05). Among IMN-treated patients, only lower lung V20 in those without reconstruction persisted (P=.022), and mean and maximum heart doses were higher than in patients without reconstruction (P=.006, P=.015, respectively). Conclusions: Implant reconstruction does not compromise the technical quality of PMRT when the IMNs are untreated. Treatment technique, not reconstruction, is the primary determinant of target coverage and normal tissue doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Intrafraction Prostate Motion on Proton Pencil Beam Scanning Delivery: A Quantitative Assessment

Purpose: To assess the dosimetric impact caused by the interplay between intrafraction prostate motion and the intermittent delivery of proton pencil beam scanning (PBS). Methods and Materials: A cohort of 10 prostate patients was treated with PBS using a bilateral single-field uniform dose (SFUD) modality. Bilateral intensity-modulated proton therapy (IMPT) plans were generated for comparison. Because beam-on time in PBS was intermittent, the actual beam-on time was determined from treatment logs. Prostate motion was generalized according to real-time Calypso tracking data from our previously reported prospective photon trial. We investigated potential dose deviations by considering the interplay effect resulting from the worst-case scenario motion and the PBS delivery sequence. Results: For both bilateral-field SFUD and IMPT plans, clinical target volume (CTV) D{sub 99}% coverage was degraded <2% owing to prostate intrafraction motion when averaged over the course of treatment, but was >10% for the worst fraction. The standard deviation of CTV D{sub 99}% distribution was approximately 1.2%. The CTV coverage of individual fields in SFUD plans degraded as time elapsed after the initial alignment, owing to prostate drift. Intensity-modulated proton therapy and SFUD demonstrated comparable results when bilateral opposed fields were used. Single-field SFUD plans that were repainted twice, which could reduce half of the treatment time, resulted in similar CTV coverage as bilateral-field plans. Conclusions: Intrafraction prostate motion affects the actual delivered dose to CTV; however, when averaged over the course of treatment, CTV D{sub 99}% coverage degraded only approximately 2% even for the worst-case scenario. The IMPT plan results are comparable to those of the SFUD plan, and similar coverage can be achieved if treated by SFUD 1 lateral field per day when rescanning the field twice to shorten the treatment time and mitigate intrafraction motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Insurance Status on Radiation Treatment Modality Selection Among Potential Candidates for Prostate, Breast, or Gynecologic Brachytherapy

Purpose: The Patient Protection and Affordable Care Act looks to expand both private and Medicaid insurance. To evaluate how these changes may affect the field of radiation oncology, we evaluated the association of insurance status with the use of brachytherapy in cancers for which this treatment technique is used. Methods and Materials: A total of 190,467 patients met the inclusion criteria, of whom 95,292 (50.0%) had breast cancer, 61,096 (32.1%) had prostate cancer, 28,194 (14.8%) had endometrial cancer, and 5885 (3.1%) had cervical cancer. A multivariate logistic regression model was used to determine the association between insurance status and receipt of brachytherapy among patients treated definitively for prostate and cervical cancer or postoperatively for breast and endometrial cancer. Results: The rates of non-Medicaid insurance were 49.9% (cervical), 85.3% (endometrial), 87.4% (breast), and 90.9% (prostate) (P<.001). In a logistic regression, patients who received radiation therapy were less likely to receive brachytherapy if they had Medicaid coverage (odds ratio [OR] 0.57, 95% confidence interval [CI] 0.53-0.61, P<.001) or did not have insurance coverage (OR 0.50, 95% CI 0.45-0.56, P<.001) compared with those with non-Medicaid insurance. On subset analysis, patients with Medicaid coverage or without insurance coverage were significantly less likely to receive brachytherapy than were those with non-Medicaid insurance for all 4 sites, except for patients with endometrial cancer. Conclusions: Despite being a cost-effective treatment modality, brachytherapy is less often used in the definitive or postoperative management of cancer in patients with Medicaid coverage or without insurance. Upcoming health policy changes resulting in the expansion of private insurance and Medicaid will likely increase access to and demand for brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robustness Recipes for Minimax Robust Optimization in Intensity Modulated Proton Therapy for Oropharyngeal Cancer Patients

Purpose: We aimed to derive a “robustness recipe” giving the range robustness (RR) and setup robustness (SR) settings (ie, the error values) that ensure adequate clinical target volume (CTV) coverage in oropharyngeal cancer patients for given gaussian distributions of systematic setup, random setup, and range errors (characterized by standard deviations of Σ, σ, and ρ, respectively) when used in minimax worst-case robust intensity modulated proton therapy (IMPT) optimization. Methods and Materials: For the analysis, contoured computed tomography (CT) scans of 9 unilateral and 9 bilateral patients were used. An IMPT plan was considered robust if, for at least 98% of the simulated fractionated treatments, 98% of the CTV received 95% or more of the prescribed dose. For fast assessment of the CTV coverage for given error distributions (ie, different values of Σ, σ, and ρ), polynomial chaos methods were used. Separate recipes were derived for the unilateral and bilateral cases using one patient from each group, and all 18 patients were included in the validation of the recipes. Results: Treatment plans for bilateral cases are intrinsically more robust than those for unilateral cases. The required RR only depends on the ρ, and SR can be fitted by second-order polynomials in Σ and σ. The formulas for the derived robustness recipes are as follows: Unilateral patients need SR = −0.15Σ{sup 2} + 0.27σ{sup 2} + 1.85Σ − 0.06σ + 1.22 and RR=3% for ρ = 1% and ρ = 2%; bilateral patients need SR = −0.07Σ{sup 2} + 0.19σ{sup 2} + 1.34Σ − 0.07σ + 1.17 and RR=3% and 4% for ρ = 1% and 2%, respectively. For the recipe validation, 2 plans were generated for each of the 18 patients corresponding to Σ = σ = 1.5 mm and ρ = 0% and 2%. Thirty-four plans had adequate CTV coverage in 98% or more of the simulated fractionated treatments; the remaining 2 had adequate coverage in 97.8% and 97.9%. Conclusions: Robustness recipes were derived that can be used in minimax robust optimization of IMPT treatment plans to ensure adequate CTV coverage for oropharyngeal cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Head and Neck Margin Reduction With Adaptive Radiation Therapy: Robustness of Treatment Plans Against Anatomy Changes

Purpose: We set out to investigate loss of target coverage from anatomy changes in head and neck cancer patients as a function of applied safety margins and to verify a cone beam computed tomography (CBCT)–based adaptive strategy with an average patient anatomy to overcome possible target underdosage. Methods and Materials: For 19 oropharyngeal cancer patients, volumetric modulated arc therapy treatment plans (2 arcs; simultaneous integrated boost, 70 and 54.25 Gy; 35 fractions) were automatically optimized with uniform clinical target volume (CTV)–to–planning target volume margins of 5, 3, and 0 mm. We applied b-spline CBCT–to–computed tomography (CT) deformable registration to allow recalculation of the dose on modified CT scans (planning CT deformed to daily CBCT following online positioning) and dose accumulation in the planning CT scan. Patients with deviations in primary or elective CTV coverage >2 Gy were identified as candidates for adaptive replanning. For these patients, a single adaptive intervention was simulated with an average anatomy from the first 10 fractions. Results: Margin reduction from 5 mm to 3 mm to 0 mm generally led to an organ-at-risk (OAR) mean dose (D{sub mean}) sparing of approximately 1 Gy/mm. CTV shrinkage was mainly seen in the elective volumes (up to 10%), likely related to weight loss. Despite online repositioning, substantial systematic errors were present (>3 mm) in lymph node CTV, the parotid glands, and the larynx. Nevertheless, the average increase in OAR dose was small: maximum of 1.2 Gy (parotid glands, D{sub mean}) for all applied margins. Loss of CTV coverage >2 Gy was found in 1, 3, and 7 of 73 CTVs, respectively. Adaptive intervention in 0-mm plans substantially improved coverage: in 5 of 7 CTVs (in 6 patients) to <2 Gy of initially planned. Conclusions: Volumetric modulated arc therapy head and neck cancer treatment plans with 5-mm margins are robust for anatomy changes and show a modest increase in OAR dose. Margin reduction improves OAR sparing with approximately 1 Gy/mm at the expense of target coverage in a subgroup of patients. Patients at risk of CTV underdosage >2 Gy in 0-mm plans may be identified early in treatment using dose accumulation. A single intervention with an average anatomy derived from CBCT effectively mitigates discrepancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Implications of Residual Tracking Errors During Robotic SBRT of Liver Metastases

Purpose: Although the metric precision of robotic stereotactic body radiation therapy in the presence of breathing motion is widely known, we investigated the dosimetric implications of breathing phase–related residual tracking errors. Methods and Materials: In 24 patients (28 liver metastases) treated with the CyberKnife, we recorded the residual correlation, prediction, and rotational tracking errors from 90 fractions and binned them into 10 breathing phases. The average breathing phase errors were used to shift and rotate the clinical tumor volume (CTV) and planning target volume (PTV) for each phase to calculate a pseudo 4-dimensional error dose distribution for comparison with the original planned dose distribution. Results: The median systematic directional correlation, prediction, and absolute aggregate rotation errors were 0.3 mm (range, 0.1-1.3 mm), 0.01 mm (range, 0.00-0.05 mm), and 1.5° (range, 0.4°-2.7°), respectively. Dosimetrically, 44%, 81%, and 92% of all voxels differed by less than 1%, 3%, and 5% of the planned local dose, respectively. The median coverage reduction for the PTV was 1.1% (range in coverage difference, −7.8% to +0.8%), significantly depending on correlation (P=.026) and rotational (P=.005) error. With a 3-mm PTV margin, the median coverage change for the CTV was 0.0% (range, −1.0% to +5.4%), not significantly depending on any investigated parameter. In 42% of patients, the 3-mm margin did not fully compensate for the residual tracking errors, resulting in a CTV coverage reduction of 0.1% to 1.0%. Conclusions: For liver tumors treated with robotic stereotactic body radiation therapy, a safety margin of 3 mm is not always sufficient to cover all residual tracking errors. Dosimetrically, this translates into only small CTV coverage reductions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring the Margin Recipe for Online Adaptive Radiation Therapy for Intermediate-Risk Prostate Cancer: An Intrafractional Seminal Vesicles Motion Analysis

Purpose: To provide a benchmark for seminal vesicle (SV) margin selection to account for intrafractional motion and to investigate the effectiveness of 2 motion surrogates in predicting intrafractional SV coverage. Methods and Materials: Fifteen prostate patients were studied. Each patient had 5 pairs (1 patient had 4 pairs) of pretreatment and posttreatment cone beam CTs (CBCTs). Each pair of CBCTs was registered on the basis of prostate fiducial markers. All pretreatment SVs were expanded with 1-, 2-, 3-, 4-, 5-, and 8-mm isotropic margins to form a series of planning target volumes, and their intrafractional coverage to the posttreatment SV determined the “ground truth” for exact coverage. Two motion surrogates, the center of mass (COM) and the border of contour, were evaluated by the use of Pearson product-moment correlation coefficient and exponential fitting for predicting SV underdosage. Action threshold of each surrogate was calculated. The margin for each surrogate was calculated according to a traditional margin recipe. Results: Ninety-five percent posttreatment SV coverage was achieved in 9%, 53%, 73%, 86%, 95%, and 97% of fractions with 1-, 2-, 3-, 4-, 5-, and 8-mm margins, respectively. The 5-mm margins provided 95% intrafractional SV coverage in over 90% of fractions. The correlation between the COM and border was weak, moderate, and strong in the left-right (L-R), anterior-posterior (A-P), and superior-inferior (S-I) directions, respectively. Exponential fitting gave the underdosage threshold of 4.5 and 7.0 mm for the COM and border. The Van Herk margin recipe recommended 0-, 0.5-, and 0.8-mm margins in the L-R, A-P, and S-I directions based on the COM, and 1.2-, 3.9-, and 2.5-mm margins based on the border. Conclusions: Five-millimeter isotropic margins for the SV constitute the minimum required to mitigate the intrafractional motion. Both the COM and the border are acceptable predictors for SV underdosage with 4.5- and 7.0-mm action threshold. Traditional margin based on the COM or border underestimates the margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Coadsorbed Water on the Photodecomposition of Acetone on TiO2(110)

The influence of coadsorbed water on the photodecomposition of acetone on TiO2 was examined using temperature programmed desorption (TPD) and the rutile TiO2(110) surface as a model photocatalyst. Of the two major influences ascribed to water in the heterogeneous photocatalysis literature (promotion via OH radical supply and inhibition due to site blocking), only the negative influence of water was observed. As long as the total water and acetone coverage was maintained well below the first layer saturation coverage (‘1 ML’), little inhibition of acetone photodecomposition was observed. However, as the total water+acetone coverage exceeded 1 ML, acetone was preferentially displaced from the first layer to physisorbed states by water and the extent of acetone photodecomposition attenuated. The displacement originated from water compressing acetone into high coverage regions where increased acetone-acetone repulsions caused displacement from the first layer. The immediate product of acetone photodecomposition was adsorbed acetate, which occupies twice as many surface sites per molecule as compared to acetone. Since the acetate intermediate was more stable on the TiO2(110) surface than either water or acetone (as gauged by TPD) and since its photodecomposition rate was less than that of acetone, additional surface sites were not opened up during acetone photodecomposition for previously displaced acetone molecules to re-enter the first layer. Results in this study suggest that increased molecular-level repulsions between organic molecules brought about by increased water coverage are as influential in the inhibiting effect of water on photooxidation rates as are water-organic repulsions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Periodic domain boundary ordering in a dense molecular adlayer: Sub-saturation carbon monoxide on Pd(111)

Here, we describe a previously unreported ordered phase of carbon monoxide adsorbed on the (111) facet of single crystal palladium at near-saturation coverage. The adlayer superstructure is identified from low energy electron diffraction to be c(16×2) with respect to the underlying Pd(111) surface net. The ideal coverage is determined to be 0.6875 ML, approximately 92% of the 0.75–ML saturation coverage. Density functional theory calculations support a model for the molecular packing characterized by strips of locally-saturated (2×2) regions, with the CO bound near high-symmetry surface sites, separated by antiphase domain boundaries. The structure exists in a narrow coverage range and is prepared by heating the saturated adlayer to desorb a small fraction of the CO. Comparison of the c(16×2) domain-boundary structure with structural motifs at lower coverages suggests that between 0.6 and 0.6875 ML the adlayer order may be more strongly influenced by interadsorbate repulsion than by adsorption-site-specific interactions. The system is an example of the structural complexity that results from the compromise between adsorbate–substrate and adsorbate–adsorbate interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO and H 2 adsorption on Au-Ni bimetallic surfaces: a combined experimental and DFT theoretical study

Au-Ni bimetallic thin films were grown on refractory metal substrates. CO and H 2 adsorption on Au-Ni bimetallic surfaces have been studied by a combination of in situ polarization modulation infrared reflection absorption spectroscopy (PM-IRRAS), temperature-programmed desorption (TPD), and density functional theory (DFT) calculations. It is found CO desorption peak shifts from 413 K on pure Ni surfaces to 293 K on the isolated Ni atoms formed by alloying with Au atoms. The sharp decrease of CO desorption temperature on Au-Ni surfaces with increasing Au coverage is caused by the change of the favored CO adsorption sites from bridge/hollow sites on pure Ni surfaces to Ni top sites on Au-Ni bimetallic surfaces. In situ PM-IRRAS shows two CO adsorption bands on Au sites at 2119 cm −1 and 2103 cm −1 on Au-Ni surfaces at 80 K, which are due to CO bound on under-coordinated Au atoms and electron negatively charged Au sites modified with nearby Ni atoms, respectively. Even with the Au-Ni surface temperature at as low as 100 K, CO adsorption induced Ni surface segregation has been observed by in situ PM-IRRAS. Furthermore, DFT calculation results discover the adsorption energy of CO on Ni top sites continues to decrease with increasing Au coverage due to the geometric ensemble effect and the lowered d-band center after Ni alloying with Au. H 2 desorption temperature decreases from 363 K on pure Ni thin films to 302 K with increasing Au coverage to 0.6 ML. A new H 2 peak appears at around 170 K on the Au-Ni surfaces with Au coverages between 0.6 ML and 0.9 ML. This new H 2 TPD peak is assigned to H 2 desorption from the totally isolated Ni sites. With Au coverage above 1.5 ML, there is no any H 2 desorption detected. Finally, the combined surface science studies and DFT calculations provide new insights into the surface structure-activity correlation of Ni-base bimetallic surface alloys.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adsorption of ethane, ethene, and ethyne on reconstructed Fe 3 O 4 (001)

The adsorption of the C2 hydrocarbons including ethane, ethene, and ethyne are studied on magnetite Fe 3 O 4 (001) by a combination of molecular beam dosing, temperature programmed desorption, and X-ray photoelectron spectroscopy. The ethane desorption profile has a single temperature invariant peak at 100 K while ethene and ethyne exhibit additional peaks at ~120 K and ~135 K. An inversion analysis is used to extract coverage dependent desorption energies as well as coverage-averaged prefactors for each molecule. Ethene and ethyne exhibit moderate coverage dependent desorption energies decreasing from ~80 to ~30 kJ/mol at saturation while ethane shows a relatively coverage invariant desorption energy ~28 kJ/mol. The desorption energies of the C2 hydrocarbons increase in order of increasing bond order. This is likely due to the enhanced interaction of the ethene and ethyne p system to the coordinatively unsaturated octahedral Fe sites (Fe oct ) on the ¬oxide surface. The saturation coverages of each C2 hydrocarbon at 82 K were also determined. Furthermore, these match well with the 2-dimensional spacing determined from their liquid densities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Strategies for Obtaining Confident Identifications in Bottom-Up Proteomics Measurements Using Hybrid FTMS instruments

Hybrid FTMS instruments, such as the LTQ-FTTM and LTQ-OrbitrapTM, are capable of generating fast duty cycle linear ion trap MS/MS data along with high resolution information without compromising the overall throughput of measurements. Combined with online LC separations, these instruments represent powerful and flexible tools for proteomics research. In the present work, we explore strategies for high throughput, high coverage proteomics measurements using hybrid FTMS instruments. Our accurate mass and time tag (AMT tag) strategy enables identification of thousands of peptides in a single LC-FTMS analysis by comparing accurate molecular mass and LC elution time information from the analysis to a reference database. An alternative strategy considered here employs linear ion trap (low resolution) MS/MS identifications generated by an appropriate search engine, such as SEQUEST; the high resolution precursor ion spectra were used to refine the MS/MS identifications, an approach termed Accurate Precursor Mass Filter (APMF). The APMF results can be additionally filtered using the LC elution time information from the AMT tag database, which constitutes a Precursor Mass and Time Filter (PMTF), the third approach implemented in this study. Both the APMF and the PMTF approaches are evaluated for coverage and confidence of peptide identifications and contrasted with the current AMT tag strategy. Two separate methodologies were used to reliably quantify identification confidence: a commonly used decoy database method and an alternative method based on the mass accuracy histogram. The two methodologies produced consistent results, confirming the validity of the identification confidence evaluations. Comparison of the three approaches has shown that the AMT tag data analysis approach may be preferential for studies giving a priority to the highest achievable coverage. The APMF approach by itself does not require AMT tag database and provides a moderate coverage combined with acceptable confidence values of ~99%.The PMTF approach yielded a significantly better peptide identification confidence, >99.9%, that essentially excluded any false peptide identifications. The results suggest that even with a perfect peptide ID (0% FDR in the peptide MS/MS database), the peak matching FDR is a function of the database size, so smaller high confidence databases are the goal. Thus a combined strategy can implement multi-pass APMF approach to generate high confidence AMT tag databases, which can be then validated using PMTF approach; the compact high quality databases will be used for subsequent high-throughput, high coverage AMT tag studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of Frothers and Oil at Saltwater–Air Interfaces for Oil Separation: Molecular Dynamics Simulations and Experimental Measurements

Separating oil from saltwater is a process relevant to some industries and may be aided by bubble and froth generation. Simulating saltwater–air interfaces adsorbed with surfactants and oil molecules can assist in understanding froth stability to improve separation. Here, combining with surface tension experimental measurements, in this work we employ molecular dynamics with a united-atom force field to linear alkane oil and three surfactant frothers, methyl isobutyl carbinol (MIBC), terpineol, and ethyl glycol butyl ether (EGBE), to investigate their synergistic behaviors for oil separation. The interfacial phenomena were measured for a range of frother surface coverages on saltwater. Density profiles of the hydrophilic and hydrophobic portions of the frothers show an expected orientation of alcohol groups adsorbing to the polar water. A decrease in surface tension with increasing surface coverage of MIBC and terpineol was observed and reflected in experiments where the frother concentration increased. Relations between surface coverage and bulk concentration were observed by comparing the surface tension decreases. Additionally, a range of oil surface coverages was explored when the interface has a thin layer of adsorbed frother molecules. Finally, the obtained results indicate that an increase in surface coverage of oil molecules led to an increase in surface tension for all frother types and the pair correlation functions depicted MIBC and terpineol as having higher distributions with water at closer distances than with oil.

54 ENVIRONMENTAL SCIENCES↗

Energetics and Structure of Nickel Atoms and Nanoparticles on MgO(100)

The growth morphology and interfacial energetics of vapor deposited Ni on the MgO(100) surface at 300 and 100 K have been studied using single crystal adsorption calorimetry (SCAC), He + low-energy ion scattering spectroscopy (LEIS), X-ray photoelectron spectroscopy (XPS), and low-energy electron diffraction (LEED). At 300 K, the Ni atoms grow as three-dimensional nanoparticles with a saturation number density of 5 × 10 16 particles/m 2 . The differential heat of adsorption at 300 K increases rapidly with coverage, from 276 (initially) to 311 kJ/mol by 0.4 ML. Thereafter, it slowly increases asymptotically to the sublimation enthalpy of bulk Ni (430 kJ/ml) by 9 ML. The Ni 2p 3/2 XPS peak binding energy at 300 K is initially (i.e., at 0.16 ML) 1.4 eV higher than that for bulk Ni(solid), but it decreases to that value at high coverage. The Ni atoms form a metastable phase at 300 K when in nanoparticles with diameter <2.5 nm, and the adhesion energy of such Ni nanoparticles to MgO(100) was found to be 3.05 J/m 2 . At 100 K, the Ni atoms form single adatoms and then 0.17 nm thick 2D islands at low coverage with fewer Ni-Ni bonds compared to the Ni nanoparticles formed at 300 K. Thus, the initial heat (i.e., for the first ~0.03 ML) is 148 kJ/mol at 100 K, 128 kJ/mol lower than at 300 K, and remains lower for the 2D islands. With increasing coverage at 100 K, the tiny 2D Ni islands grow in size to cover nearly the entire surface before thickening. Lastly, the XPS Ni 2p 3/2 peak binding energy for 0.21 ML Ni on MgO(100) at 100 K is 2.2 eV higher than that for bulk Ni(solid), suggesting charge transfer from Ni to MgO(100) and formation of Ni 2+ at very low coverage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗