Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Photon temporal-mode readout for inference of neutron star merger remnant gravitational waves

Gravitational waves emitted after neutron star binary coalescences and the information they carry about dense matter are a high-priority target for next-generation detectors. Even though such detectors are expected to observe millions of signals, detectable postmerger emission will remain rare. Here, in this work, we explore postmerger detectability and inference through an alternative detector readout scheme for data dominated by quantum-noise, which is the case above 1 kHz; photon-counting. In such a readout, signals and noise become quantized into discrete distributions corresponding to the detection of single photons measured in a chosen basis of modes. Through simulated data, we demonstrate that photon counting can be efficient even for weak signals. We find ∼1 in 100 signals with a postmerger signal-to-noise ratio of 0.2 can result in a single photon and thus be detected. Furthermore, after 2 ×10 4 signals—equivalent to 10 −2 to 1.5 years of observation—photon counting results in a twofold improvement in the measurement of the radius of a 1.6⁢𝑀 ⊙ neutron star. Constraints can be further tightened if the detector classical noise is reduced. Photon counting offers a promising alternative to traditional homodyne readout techniques for extracting information from low signal-to-noise ratio postmerger signals.

gravitational wave detection↗

Time encoded radiation imaging

The various technologies presented herein relate to detecting nuclear material at a large stand-off distance. An imaging system is presented which can detect nuclear material by utilizing time encoded imaging relating to maximum and minimum radiation particle counts rates. The imaging system is integrated with a data acquisition system that can utilize variations in photon pulse shape to discriminate between neutron and gamma-ray interactions. Modulation in the detected neutron count rates as a function of the angular orientation of the detector due to attenuation of neighboring detectors is utilized to reconstruct the neutron source distribution over 360 degrees around the imaging system. Neutrons (e.g., fast neutrons) and/or gamma-rays are incident upon scintillation material in the imager, the photons generated by the scintillation material are converted to electrical energy from which the respective neutrons/gamma rays can be determined and, accordingly, a direction to, and the location of, a radiation source identified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing Axial Symmetry Breaking in the Galaxy with Gaia Data Release 2

We study a set of solar neighborhood ($d < 3$ kpc) stars from Gaia Data Release 2 to determine azimuthal star count differences, i.e., left and right of the line from the Galactic center through the sun - and compare these differences north and south. In this companion paper to Gardner et al. (2020), we delineate our procedures to remove false asymmetries from sampling effects, incompleteness, and/or interloper populations, as this is crucial to tests of axisymmetry. Particularly, we have taken care to make appropriate selections of magnitude, color, in-plane Galactocentric radius and Galactic $|b|$ and $|z|$. We find that requiring parallax determinations of high precision induces sampling biases, so that we eschew such requirements and exclude, e.g., regions around the lines of sight to the Magellanic clouds, along with their mirror-image lines of sight, to ensure well-matched data sets. After making conservative cuts, we demonstrate the existence of azimuthal asymmetries, and find differences in those, north and south. These asymmetries give key insights into the nature and origins of the perturbations on Galactic matter, allowing us to assess the relative influence of the Magellanic Clouds (LMC & SMC), the Galactic bar, and other masses on the Galactic mass distribution, as described in Gardner et al. (2020). The asymmetry's radial dependence reveals variations that we attribute to the Galactic bar, and it changes sign at a radius of $(0.95 \pm 0.03) R_0$, with $R_0$ the Sun-Galactic-Center (GC) distance, to give us the first direct assessment of the outer Lindblad resonant radius.

79 ASTRONOMY AND ASTROPHYSICS↗

Predicting Biological Cleanliness: An Empirical Bayes Approach for Spacecraft Bioburden Accounting

To comply with the international planetary protection policy set forth by the Committee on Space Research and NASA Agency level requirements, spacecraft destined to biologically sensitive planetary bodies have to minimize terrestrial biological contamination. Analysis, testing and inspection are the standard forward verification activities that are used to demonstrate compliance with the biological contamination requirements. For testing of spacecraft surface areas, a swab or wipe sample is collected from surfaces prior to last access and subsequently processed in the lab using NASA Approved Planetary Protection Methods for Culture Based Assays. Raw data resulting from this assay is then statistically treated employing a mathematical paradigm stemming from the 1970’s Viking Lander Project to generate the bioburden density and total microbial bioburden present. This standard approach arbitrarily accounts for error and provides an upper conservative bound as it reports the maximum number of spores estimated to be present on flight hardware surfaces. A bioburden density estimate factors in the following variables: the observed bioburden count, representative volume processed, sampling efficiencies. Notably, to account for error in the approach, a 0 observed count is arbitrarily changed to a count of 1 for each hardware grouping. The data generated by spacecraft bioburden verification campaigns in the past have resulted in <80% of wipes and <90% of swabs containing a bioburden count of 0. As such, having a robust and well documented statistical approach for dealing with the probability of low incident rates is necessary to be able to estimate spacecraft bioburden. Being able to statistically describe the bioburden distribution and associated confidence level is a gamechanger for the development of bioburden allocations during mission design and will allow for tighter management of risk throughout spacecraft build. Thus, Empirical Bayes statistical approach was evaluated to estimate the microbial bioburden on spacecraft to mitigate the aforementioned mathematical concerns and provide a probabilistic bioburden distribution of the flight hardware surface. For application of this approach to performing bioburden calculations, a range of non-informative prior assumptions on hardware surfaces are explored for Bayesian analyses while informative priors using posterior distributions from prior assays are utilized for Empirical Bayes analyses. Several non-informative priors are currently under investigation to assess fitness including use of these priors to serve as a foundation to build off of NASA specification values or a basis of risk to account for unknowns during the integration and testing process. Informative priors under consideration are generated using sampled bioburden values from hardware originating within like processing environments (e.g. vendor cleaning process or similar assembly process), temporal spacecraft status events as a prediction for hardware cleanliness of future samples, and heritage system bioburden actuals to predict allocation for subsequent missions. Informative priors and probabilistic bioburden distributions are then validated using data sets from the Mars Exploration Rover, Mars Science Laboratory, and InSight missions. Using Empirical Bayes approach to generate a probabilistic bioburden distribution as demonstrated through mission use cases provides a valid approach for use in the end-to-end requirements verification process.

97 MATHEMATICS AND COMPUTING↗

Bayesian Framework for Bioburden Density Estimation in Planetary Protection

To comply with the international planetary protection policy set forth by the Committee on Space Research and NASA Agency level requirements, spacecraft destined to biologically sensitive planetary bodies have to minimize terrestrial biological contamination. Analysis, testing and inspection are the standard forward verification activities that are used to demonstrate compliance with the biological contamination requirements. For testing of spacecraft surface areas, a swab or wipe sample is collected from surfaces prior to last access and subsequently processed in the lab using NASA Approved Planetary Protection Methods for Culture Based Assays. Raw data resulting from this assay is then statistically treated employing a mathematical paradigm stemming from the 1970’s Viking Lander Project to generate the bioburden density and total microbial bioburden present. This standard approach arbitrarily accounts for error and provides an upper conservative bound as it reports the maximum number of spores estimated to be present on flight hardware surfaces. A bioburden density estimate factors in the following variables: the observed bioburden count, representative volume processed, sampling efficiencies. Notably, to account for error in the approach, a 0 observed count is arbitrarily changed to a count of 1 for each hardware grouping. The data generated by spacecraft bioburden verification campaigns in the past have resulted in <80% of wipes and <90% of swabs containing a bioburden count of 0. As such, having a robust and well documented statistical approach for dealing with the probability of low incident rates is necessary to be able to estimate spacecraft bioburden. Being able to statistically describe the bioburden distribution and associated confidence level is a gamechanger for the development of bioburden allocations during mission design and will allow for tighter management of risk throughout spacecraft build. Thus, Empirical Bayes statistical approach was evaluated to estimate the microbial bioburden on spacecraft to mitigate the aforementioned mathematical concerns and provide a probabilistic bioburden distribution of the flight hardware surface. For application of this approach to performing bioburden calculations, a range of non-informative prior assumptions on hardware surfaces are explored for Bayesian analyses while informative priors using posterior distributions from prior assays are utilized for Empirical Bayes analyses. Several non-informative priors are currently under investigation to assess fitness including use of these priors to serve as a foundation to build off of NASA specification values or a basis of risk to account for unknowns during the integration and testing process. Informative priors under consideration are generated using sampled bioburden values from hardware originating within like processing environments (e.g. vendor cleaning process or similar assembly process), temporal spacecraft status events as a prediction for hardware cleanliness of future samples, and heritage system bioburden actuals to predict allocation for subsequent missions. Informative priors and probabilistic bioburden distributions are then validated using data sets from the Mars Exploration Rover, Mars Science Laboratory, and InSight missions. Using Empirical Bayes approach to generate a probabilistic bioburden distribution as demonstrated through mission use cases provides a valid approach for use in the end-to-end requirements verification process.

97 - MATHEMATICS AND COMPUTING↗

Improving the Field Portability of Neutron and Gamma Counting Techniques

Savannah River National Laboratory (SRNL) puts science to work by developing techniques that better meet customers needs for in-situ measurements. There is high demand for laboratory quality measurements in field situations, improving the cost and speed for first responders and environmental monitoring. This work focused on two improvements (1) reading a signal from a neutron detector using a Raspberry Pi (2) testing the Peak-to-Valley method for determining the depth of a source in soil contamination measurements. A Raspberry Pi is a cheap, compact computer. This affordable, compact computer is able to do simple tasks that a desktop computer is able to do, like spreadsheets, browse the internet, play games and even program a simple robot. Additionally, a Raspberry Pi can run off of a battery, so it could be deployed for long term measurements in adverse conditions like neutron monitors deployed in a shipping port. Using the Raspberry Pi and libraries easily accessible on the internet, a code was written in Python that allows the Pi to keep track of how many times a button is pushed. This work will be used with the future goal of creating low power-budget neutron detectors. 1) Make sure Python was correctly installed on the Raspberry Pi. 2) Write a code that will keep track of how many times a button connected to the Pi is pressed. A code was written to use the Raspberry Pi to count the number of times the button was pushed. Moving forward the Raspberry Pi will be tested with a neutron counter. Ideally, each signal from the neutron pulse will be equivalent of 'push the button' and be counted. In the characterization of a soil contamination area both the location and the depth of the source is important. Attenuation of the source by the soil can make determining its depth challenging, particularly for monoenergetic radionuclides like Cs-137. To address this issue, a method of calculating the 'peak-to-valley' ratio of the gamma count spectra is implemented to help calculate the known depth of the source. 1) Determine the 'peak-to-valley' ratio of a Cs-137 source at different depths. 2) Find an appropriate function to serve as a model for the peak-to-valley ratio as a function of depth. Several Petri dishes, filled with sand, were stacked with one containing a Cs-137 source. The individual Petri dishes allowed for the source to be placed at different depths. A bucket was placed over the sand and source, to keep the detector at a consistent height. A Petri dish containing a Eu-155 source, which acted as an internal calibration standard, was placed on top of the bucket. A NaI detector was place on top of the Eu-155 source and the assembly was surrounded by a tungsten shield. Count times were 20 minutes and the data was analyzed using PeakEasy. Data was recorded for Cs-137 at a series of depths in sand. Both exponential and logarithmic functions provided a reasonable fit to the data. The experimental data showed a decreasing 'peak-to-valley' ratio as the depth was increased. The next steps for this project involves determining the optimum fit function and combining the results from sand to different soil types to get a better representation of the soil found at SRS. Eventually, the peak-to-valley ratio will be used to estimate the depth of contamination in field measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GIANT GROUND LEVEL ENHANCEMENT OF RELATIVISTIC SOLAR PROTONS ON 2005 JANUARY 20. I. SPACESHIP EARTH OBSERVATIONS

A ground level enhancement (GLE) is a solar event that accelerates ions (mostly protons) to GeV range energies in such great numbers that ground-based detectors, such as neutron monitors, observe their showers in Earth's atmosphere above the Galactic cosmic ray background. GLEs are of practical interest because an enhanced relativistic ion flux poses a hazard to astronauts, air crews, and aircraft electronics, and provides the earliest direct indication of an impending space radiation storm. The giant GLE of 2005 January 20 was the second largest on record (and largest since 1956), with up to 4200% count rate enhancement at sea level. We analyzed data from the Spaceship Earth network, supplemented to comprise 13 polar neutron monitor stations with distinct asymptotic viewing directions and Polar Bare neutron counters at South Pole, to determine the time evolution of the relativistic proton density, energy spectrum, and three-dimensional directional distribution. We identify two energy-dispersive peaks, indicating two solar injections. The relativistic solar protons were initially strongly beamed, with a peak maximum-to-minimum anisotropy ratio over 1000:1. The directional distribution is characterized by an axis of symmetry, determined independently for each minute of data, whose angle from the magnetic field slowly varied from about 60 Degree-Sign to low values and then rose to about 90 Degree-Sign . The extremely high relativistic proton flux from certain directions allowed 10 s tracking of count rates, revealing fluctuations of period {approx}> 2 minutes with up to 50% fractional changes, which we attribute to fluctuations in the axis of symmetry.

79 ASTRONOMY AND ASTROPHYSICS↗

A DEEP 1.2 mm MAP OF THE LOCKMAN HOLE NORTH FIELD

We present deep 1.2 mm continuum mapping of a 566 arcmin{sup 2} area within the Lockman Hole North (LHN) field, previously a target of the Spitzer Wide-Area Infrared Extragalactic survey and extremely deep 20 cm mapping with the Very Large Array, which we have obtained using the Max-Planck millimeter bolometer (MAMBO) array on the IRAM 30 m telescope. After filtering, our full map has an rms sensitivity ranging from 0.45 to 1.5 mJy beam{sup -1}, with an average of 0.75 mJy beam{sup -1}. Using the pixel flux distribution (PFD) in a map made from our best data, we determine the shape, normalization, and approximate flux density cutoff for 1.2 mm number counts well below our nominal sensitivity and confusion limits. After validating our full data set through comparison with this map, we successfully detect 41 1.2 mm sources with signal-to-noise ratio (S/N) > 4.0 and S{sub 1.2{sub mm}} {approx_equal} 2-5 mJy. We use the most significant of these detections to directly determine the integral number counts down to 1.8 mJy, which are consistent with the results of the PFD analysis. Ninety-three percent of our 41 individual detections have 20 cm counterparts, 49% have Spitzer/MIPS 24 {mu}m counterparts, and one may have a significant Chandra X-ray counterpart. We resolve {approx_equal} 3% of the cosmic infrared background (CIB) at 1.2 mm into significant detections and directly estimate a 0.05 mJy faint-end cutoff for the counts that is consistent with the full intensity of the 1.2 mm CIB. The median redshift of our 17 detections with spectroscopic or robust photometric redshifts is z{sub median} = 2.3, and rises to z{sub median} = 2.9 when we include redshifts estimated from the radio/far-infrared spectral index. By using a nearest neighbor and angular correlation function analysis, we find evidence that our S/N > 4.0 detections are clustered at the 95% confidence level.

79 ASTRONOMY AND ASTROPHYSICS↗

Trials and tribulations in the first three years in operation of the SSAMS for biomedical 14 C-AMS at LLNL

We report on the first several years of operation of our recently installed 250 kV SSAMS at LLNL, purchased to replace our 1-MV AMS system for the measurement of 14 C from labeled biochemical samples. We have modified the ion source region to improve ion output. Additionally, the SSAMS required significant software modifications to the data acquisition system in order to accurately measure 14 C at the high-count rates typically encountered with labeled biochemical samples. Here, we found that the data can be corrected assuming a nonparalyzable dead time response with a single event dead time of 6 µs. Since operation began, we have measured over 13,000 graphitic unknowns and over 1900 standards with an overall precision of 1.0%. We have optimized our system for the analysis of CO 2 gas samples. We compared aliquots of identical samples measured as solid graphite and as liquid drops. Excellent agreement was found between the two, although the average precision of the graphite targets was an order of magnitude better than the liquid drop analysis due to the much larger number of 14 C atoms available for measurement.

42 ENGINEERING↗

TriC: Distributed-memory Triangle Counting by Exploiting the Graph Structure

Graph analytics has emerged as an important tool in the analysis of large scale data from diverse application domains such as social networks, cyber security and bioinformatics. Counting the number of triangles in a graph is a fundamental kernel with several applications such as detecting the community structure of a graph or in identifying important vertices in a graph. The ubiquity of massive datasets is driving the need to scale graph analytics on parallel systems. However, numerous challenges exist in efficiently parallelizing graph algorithms, especially on distributed-memory systems. Irregular memory accesses and communication patterns, low computation to communication ratios, and the need for frequent synchronization are some of the leading challenges. In this paper, we present TriC, our distributed-memory implementation of triangle counting in graphs using the Message Passing Interface (MPI), as a submission to the 2020 GraphChallenge competition. Using a set of synthetic and real-world inputs from the challenge, we demonstrate a speedup of up to 90x relative to previous work on 32 processor-cores of a NERSC Cori node. We also provide details from distributed runs with up to8192 processes along with strong scaling results. The observations presented in this work provide an understanding of the system-level bottlenecks at scale that specifically impact sparse-irregular workloads and will therefore benefit other efforts to parallelize graph algorithms.

Halappanavar, Mahantesh↗

Waste Characterization Using Gamma Ray Spectrometry with Automated Efficiency Optimization - 13404

Gamma ray spectrometry using High Purity Germanium (HPGe) detectors is commonly employed in assaying radioactive waste streams from a variety of sources: nuclear power plants, Department of Energy (DOE) laboratories, medical facilities, decontamination and decommissioning activities etc. The radioactive material is typically packaged in boxes or drums (for e.g. B-25 boxes or 208 liter drums) and assayed to identify and quantify radionuclides. Depending on the origin of the waste stream, the radionuclides could be special nuclear materials (SNM), fission products, or activation products. Efficiency calibration of the measurement geometry is a critical step in the achieving accurate quantification of radionuclide content. Due to the large size of the waste items, it is impractical and expensive to manufacture gamma ray standard sources for performing a measurement based calibration. For well over a decade, mathematical efficiency methods such as those in Canberra's In Situ Object Counting System (ISOCS) have been successfully employed in the efficiency calibration of gamma based waste assay systems. In the traditional ISOCS based calibrations, the user provides input data such as the dimensions of the waste item, the average density and fill height of the matrix, and matrix composition. As in measurement based calibrations, the user typically defines a homogeneous matrix with a uniform distribution of radioactivity. Actual waste containers can be quite nonuniform, however. Such simplifying assumptions in the efficiency calibration could lead to a large Total Measurement Uncertainty (TMU), thus limiting the amount of waste that can be disposed of as intermediate or low activity level waste. To improve the accuracy of radionuclide quantification, and reduce the TMU, Canberra has developed the capability to optimize the efficiency calibration using the ISOCS method. The optimization is based on benchmarking the efficiency shape and magnitude to the data available in the analyzed gamma ray spectra. Data from measurements of a given item in multiple counting geometries are among the powerful benchmarks that could be used in the optimization. Also, while assaying a waste stream with fission products and activation products emitting gamma lines of multiple energies, optimizing the efficiency on the basis of line activity consistency is very effective. In the present paper, the ISOCS- based optimization methodology is applied to measurement scenarios involving multiple counting geometries, and multi-gamma-line radionuclides. Results will be presented along with accuracy and precision estimates for each measurement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of Blending and In-Tank Pretreatment on Direct Feed Hanford High Level Waste Vitrification - 18434

A direct feed high level waste (DFHLW) option is under consideration for early operations of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). In this option, the Pretreatment Facility would be bypassed in order to support an earlier start-up of the HLW Vitrification Facility. For HLW, this would mean that ultrafiltration and caustic leaching that would otherwise have been performed either would not be performed or would be replaced by interim pretreatment functions such as in-tank washings. These changes could result in higher aluminum contents, higher chromium contents, higher fractions of supernate, and lower solids contents in the HLW feed. As a result, glass formulations and downstream vitrification operations will be impacted. In the present work, we investigate the effects of various waste blending and in-tank pretreatment scenarios on DFHLW glass waste loadings, canister counts, and processing rates. Eleven source tanks and five waste groups were selected for the studies of waste blending. In addition, the five waste groups selected were the subjects of an in-tank pretreatment study. Glass property-composition models and melter test data were used to calculate waste loadings, canister counts, processing rates, and treatment durations for a range of DFHLW scenarios. The processing scenarios were defined by the types of waste blending and in-tank pretreatment that were assumed. Blending cases were evaluated that ranged between the 'No Blend' and 'Total Blend' extremes and included pairwise blending (blending of two source tanks, either completely or in various proportions) and macro-batches formed from various combinations of the source tanks. Over 36,000 possible pairwise blending scenarios were evaluated and an optimal retrieval/blending sequence was identified. The waste loading of this optimal sequence is within 0.03 wt% of the 'Total Blend' case. Further, a total of 38 retrieval sequences were identified that have waste loadings within 0.1 wt% of the 'Total Blend' case. To evaluate the effects of in-tank pretreatment, an in-tank wash/settle/decant process was assumed and tank-specific wash factors were employed. Washing of the macro-batch blends gave a general increase in HLW loading, decrease in canister count, and decrease in glass yield. Glass yields are towards the low end of the values expected for the WTP, which could lead to lower than nominal glass production rates. The waste loading increases and canister count reductions with washing were small for two of the wastes indicating that direct treatment of the unwashed waste may be practical. For wastes that are relatively low in sulfate and halides, excessive washing is counterproductive. The results highlight the importance of maintaining high solids content in the HLW feed to maintain glass production rates. The results also illustrate that the optimum washing strategy will need to be evaluated on a tank-to-tank basis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A plastic miniature x-ray emission spectrometer based on the cylindrical von Hamos geometry

We present a short working distance miniature x-ray emission spectrometer (miniXES) based on the cylindrical von Hamos geometry. We describe the general design principles for the spectrometer and detail a specific implementation that covers K{beta} and valence level emission from Fe. Large spatial and angular access to the sample region provides compatibility with environmental chambers, microprobe, and pump/probe measurements. The primary spectrometer structure and optic is plastic, printed using a 3-dimensional rapid-prototype machine. The spectrometer is inexpensive to construct and is portable; it can be quickly set up at any focused beamline with a tunable narrow bandwidth monochromator. The sample clearance is over 27 mm, providing compatibility with a variety of environment chambers. An overview is also given of the calibration and data processing procedures, which are implemented by a multiplatform user-friendly software package. Finally, representative measurements are presented. Background levels are below the level of the K{beta}{sub 2,5} valence emission, the weakest diagram line in the system, and photometric analysis of count rates finds that the instrument is performing at the theoretical limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a novel collimator for molecular breast tomosynthesis

Here, this study investigated a novel gamma camera for molecular breast tomosynthesis (MBT), which is a nuclear breast imaging method that uses limited angle tomography. The camera is equipped with a variable angle, slant-hole (VASH) collimator that allows the camera to remain close to the breast throughout the acquisition. The goal of this study was to evaluate the spatial resolution and count sensitivity of this camera and to compare contrast and contrast-to-noise ratio (CNR) with conventional planar imaging using an experimental breast phantom. Methods The VASH collimator mounts to a commercial gamma camera for breast imaging that uses a pixelated (3.2 mm), 15 × 20 cm NaI crystal. Spatial resolution was measured in planar images over a range of distances from the collimator (30-100 mm) and a range of slant angles (–25° to 25°) using 99m Tc line sources. Spatial resolution was also measured in reconstructed MBT images including in the depth dimension. The images were reconstructed from data acquired over the -25° to 25° angular range using an iterative algorithm adapted to the slant-hole geometry. Sensitivity was measured over the range of slant angles using a disk source. Measured spatial resolution and sensitivity were compared to theoretical values. Contrast and CNR were measured using a breast phantom containing spherical lesions (6.2 mm and 7.8 mm diameter) and positioned over a range of depths in the phantom. The MBT and planar methods had equal scan time, and the count density in the breast phantom data was similar to that in clinical nuclear breast imaging. The MBT method used an iterative reconstruction algorithm combined with a postreconstruction Metz filter. Results The measured spatial resolution in planar images agreed well with theoretical calculations over the range of distances and slant angles. The measured FWHM was 9.7 mm at 50 mm distance. In reconstructed MBT images, the spatial resolution in the depth dimension was approximately 2.2 mm greater than the other two dimensions due to the limited angle data. The measured count sensitivity agreed closely with theory over all slant angles when using a wide energy window. At 0° slant angle, measured sensitivity was 19.7 counts sec -1 μ Ci -1 with the open energy window and 11.2 counts sec -1 μ Ci -1 with a 20% wide photopeak window (126 to 154 keV). The measured CNR in the MBT images was significantly greater than in the planar images for all but the lowest CNR cases where the lesion detectability was extremely low for both MBT and planar. The 7.8 mm lesion at 37 mm depth was marginally detectable in the planar image but easily visible in the MBT image. The improved CNR with MBT was due to a large improvement in contrast, which out-weighed the increase in image noise. Conclusion The spatial resolution and count sensitivity measurements with the prototype MBT system matched theoretical calculations, and the measured CNR in breast phantom images was generally greater with the MBT system compared to conventional planar imaging. These results demonstrate the potential of the proposed MBT system to improve lesion detection in nuclear breast imaging.

60 APPLIED LIFE SCIENCES↗

Gamma ray spectroscopy at high energy and high time resolution at JET

In fusion plasmas gamma ray emission is caused by reactions of fast particles, such as fusion alpha particles, with impurities. Gamma ray spectroscopy at JET has provided valuable diagnostic information on fast fuel as well as fusion product ions. Improvements of these measurements are needed to fully exploit the flux increase provided by future high power experiments at JET and ITER. Limiting aspects are, for instance, the count rate capability due to a high neutron/gamma background combined with slow detector response and a modest energy resolution due to the low light yield of the scintillators. This paper describes the solutions developed for achieving higher energy resolution, signal to background, and time resolution. The detector design is described based on the new BrLa{sub 3} scintillator crystal. The paper will focus on hardware development, including a photomultiplier tube capable of stable operation at counting rate as high as 1 MHz, the magnetic shielding, and the fast digital data acquisition system.

36 MATERIALS SCIENCE↗

STAR COUNT DENSITY PROFILES AND STRUCTURAL PARAMETERS OF 26 GALACTIC GLOBULAR CLUSTERS

We used an appropriate combination of high-resolution Hubble Space Telescope observations and wide-field, ground-based data to derive the radial stellar density profiles of 26 Galactic globular clusters from resolved star counts (which can be all freely downloaded on-line). With respect to surface brightness (SB) profiles (which can be biased by the presence of sparse, bright stars), star counts are considered to be the most robust and reliable tool to derive cluster structural parameters. For each system, a detailed comparison with both King and Wilson models has been performed and the most relevant best-fit parameters have been obtained. This collection of data represents the largest homogeneous catalog collected so far of star count profiles and structural parameters derived therefrom. The analysis of the data of our catalog has shown that (1) the presence of the central cusps previously detected in the SB profiles of NGC 1851, M13, and M62 is not confirmed; (2) the majority of clusters in our sample are fit equally well by the King and the Wilson models; (3) we confirm the known relationship between cluster size (as measured by the effective radius) and galactocentric distance; (4) the ratio between the core and the effective radii shows a bimodal distribution, with a peak at {approx}0.3 for about 80% of the clusters and a secondary peak at {approx}0.6 for the remaining 20%. Interestingly, the main peak turns out to be in agreement with that expected from simulations of cluster dynamical evolution and the ratio between these two radii correlates well with an empirical dynamical-age indicator recently defined from the observed shape of blue straggler star radial distribution, thus suggesting that no exotic mechanisms of energy generation are needed in the cores of the analyzed clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

COUNTS-IN-CYLINDERS IN THE SLOAN DIGITAL SKY SURVEY WITH COMPARISONS TO N-BODY SIMULATIONS

Environmental statistics provide a necessary means of comparing the properties of galaxies in different environments, and a vital test of models of galaxy formation within the prevailing hierarchical cosmological model. We explore counts-in-cylinders, a common statistic defined as the number of companions of a particular galaxy found within a given projected radius and redshift interval. Galaxy distributions with the same two-point correlation functions do not necessarily have the same companion count distributions. We use this statistic to examine the environments of galaxies in the Sloan Digital Sky Survey Data Release 4 (SDSS DR4). We also make preliminary comparisons to four models for the spatial distributions of galaxies, based on N-body simulations and data from SDSS DR4, to study the utility of the counts-in-cylinders statistic. There is a very large scatter between the number of companions a galaxy has and the mass of its parent dark matter halo and the halo occupation, limiting the utility of this statistic for certain kinds of environmental studies. We also show that prevalent empirical models of galaxy clustering, that match observed two- and three-point clustering statistics well, fail to reproduce some aspects of the observed distribution of counts-in-cylinders on 1, 3, and 6 h{sup -1} Mpc scales. All models that we explore underpredict the fraction of galaxies with few or no companions in 3 and 6 h{sup -1} Mpc cylinders. Roughly 7% of galaxies in the real universe are significantly more isolated within a 6 h{sup -1} Mpc cylinder than the galaxies in any of the models we use. Simple phenomenological models that map galaxies to dark matter halos fail to reproduce high-order clustering statistics in low-density environments.

79 ASTRONOMY AND ASTROPHYSICS↗

Counts-in-Cylinders in the Sloan Digital Sky Survey with Comparisons to N-Body

Environmental statistics provide a necessary means of comparing the properties of galaxies in different environments and a vital test of models of galaxy formation within the prevailing, hierarchical cosmological model. We explore counts-in-cylinders, a common statistic defined as the number of companions of a particular galaxy found within a given projected radius and redshift interval. Galaxy distributions with the same two-point correlation functions do not necessarily have the same companion count distributions. We use this statistic to examine the environments of galaxies in the Sloan Digital Sky Survey, Data Release 4. We also make preliminary comparisons to four models for the spatial distributions of galaxies, based on N-body simulations, and data from SDSS DR4 to study the utility of the counts-in-cylinders statistic. There is a very large scatter between the number of companions a galaxy has and the mass of its parent dark matter halo and the halo occupation, limiting the utility of this statistic for certain kinds of environmental studies. We also show that prevalent, empirical models of galaxy clustering that match observed two- and three-point clustering statistics well fail to reproduce some aspects of the observed distribution of counts-in-cylinders on 1, 3 and 6-h{sup -1}Mpc scales. All models that we explore underpredict the fraction of galaxies with few or no companions in 3 and 6-h{sup -1} Mpc cylinders. Roughly 7% of galaxies in the real universe are significantly more isolated within a 6 h{sup -1} Mpc cylinder than the galaxies in any of the models we use. Simple, phenomenological models that map galaxies to dark matter halos fail to reproduce high-order clustering statistics in low-density environments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗