Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Increasing Density and Reducing Costs of Data Acquisition

There are a number of reasons why it is important to increase the density of data acquisition functions. Sensor fusion seeks to integrate large numbers of sensors into a decision network. Addition of health monitoring functions may incur additional sensor requirements. But at the same time, it is important to reduce the per-channel costs of data acquisition systems. Often the most significant cost is the management of data acquisition networks, which incurs substantial costs associated with transducer installation, configuration, calibration, and maintenance. Alternatives that lower the cost of the transducer system and reduce the data acquisition system channel count will directly impact initial system costs. Other techniques that affect maintenance and operating costs will contribute to reducing life cycle costs. This paper describes work undertaken to explore alternative architectures for lowering the cost per transducer function using a MEMS-based accelerometer as the model.

Schmalzel, J. L.↗

Terrestrial Gamma-ray Flash (TGF) Observations with the Gamma-ray Burst Monitor on the Fermi Observatory

Terrestrial Gamma-ray Flashes (TGFs) have now been detected with four different orbiting spacecraft. The latest observations are being made with the scintillation detectors of Gamma-ray Burst Monitor (GBM) on the Fermi Gamma-ray Space Telescope Observatory (Fermi). Although this experiment was designed and optimized for the observation of cosmic gamma-ray bursts (GRBs), it has unprecedented capabilities for TGF observations, surpassing those of the experiment that discovered TGFs, the BATSE experiment on the Compton Gamma-ray Observatory. Launched in June 2008 from the Kennedy Space Center, the Fermi-GBM has been detecting about one TGF every four weeks. The thick bismuth germinate (BGO) scintillation detectors of the GBM have now observed photon energies from TGFs at energies up to approx.40 MeV. Individual photons are detected with an absolute timing accuracy of 2 microsec. Unlike the BATSE instrument, the GBM data system allows higher counting rates to be recorded and deadtime characteristics are well-known and correctable; thus the saturation effects seen with BATSE are avoided. TGF pulses as narrow as approx.0.1ms have been observed with the GBM. Like BATSE (and unlike RHESSI) an on-board trigger is required to detect TGFs. The minimum time window for this trigger is 16ms. A trigger window this wide greatly reduces the number of detected TGFs, since they most often have a much shorter duration than this window, thus reducing the signal-to-background. New on-board trigger algorithms based on detected photon energies are about to be implemented; this should increase the number of TGF triggers. High-energy spectra from TGFs observed with Fermi-GBM will be described.

Fishman, Gerald J.↗

Radiation Dosimetry via Automated Fluorescence Microscopy

A developmental instrument for assessment of radiation-induced damage in human lymphocytes includes an automated fluorescence microscope equipped with a one or more chargecoupled- device (CCD) video camera(s) and circuitry to digitize the video output. The microscope is also equipped with a three-axis translation stage that includes a rotation stage, and a rotary tray that holds as many as thirty specimen slides. The figure depicts one version of the instrument. Once the slides have been prepared and loaded into the tray, the instrument can operate unattended. A computer controls the operation of the stage, tray, and microscope, and processes the digital fluorescence-image data to recognize and count chromosomes that have been broken, presumably by radiation. The design and method of operation of the instrument exploit fluorescence in situ hybridization (FISH) of metaphase chromosome spreads, which is a technique that has been found to be valuable for monitoring the radiation dose to circulating lymphocytes. In the specific FISH protocol used to prepare specimens for this instrument, metaphase lymphocyte cultures are chosen for high mitotic index and highly condensed chromosomes, then several of the largest chromosomes are labeled with three of four differently colored whole-chromosome-staining dyes. The three dyes, which are used both individually and in various combinations, are fluorescein isothiocyanate (FITC), Texas Red (or equivalent), and Cy5 (or equivalent); The fourth dye 4',6-diamidino- 2-phenylindole (DAPI) is used as a counterstain. Under control by the computer, the microscope is automatically focused on the cells and each slide is scanned while the computer analyzes the DAPI-fluorescence images to find the metaphases. Each metaphase field is recentered in the field of view and refocused. Then a four-color image (more precisely, a set of images of the same view in the fluorescent colors of the four dyes) is acquired. By use of pattern-recognition software developed specifically for this instrument, the images in the various colors are processed to recognize the metaphases and count the chromosome fragments of each color within the metaphases. The intermediate results are then further processed to estimate the proportion of cells that have suffered genetic damage. The prototype instrument scans at an average areal rate of 4.7 mm2/h in unattended operation, finding about 14 metaphases per hour. The false-alarm rate is typically less than 3 percent, and the metaphase-miss rate has been estimated to be less than 5 percent. The counts of chromosomes and fragments thereof are 50 to 70 percent accurate.

Castleman, Kenneth R.↗

GeV/TeV Cooperation: Ongoing Strategies

Although many of their scientific interests overlap, current GeV and reV telescopes have many properties that show strong contrasts. Field of view, duty cycle, speed of analysis, photon counting statistics, background, and data release policies differ markedly. The challenge for cooperative studies has been to make the best use of complementary properties. One example is GeV discovery and monitoring surveys for AGN coupled with rev time variability studies. Another is GeV spectral measurements for Galactic sources joined with reV spatial resolution. In many cases, sharing of information has been a positive factor, and continuing to explore ways to exchange results and ideas will help to maximize the scientific return from all gamma-ray observatories.

Thompson, David J.↗

The Bombardment History of 4 Vesta as Told by Sample Geochronology

The Dawn mission showed asteroid 4 Vesta to be an extensively cratered body, ancient in age, with craters in a variety of morphologies and preservation states [1-3]. Tying Vesta's relative crater ages to an absolute impact history can be accomplished through investigations of the HED (howardite, eucrite, diogenite) meteorites. Eucrites are crustal basalts and gabbros, diogenites are mostly orthopyroxenites representing lower crust or upper mantle materials, and howardites are mixed breccias containing both lithologies. Eucrite 53Mn-53Cr systematics show that the HED parent body globally differentiated by ~4.56 Ga and fully crystallized soon afterwards [4]. Much later, many eucrites were brecciated and heated by large impacts into the parent body surface. Disturbance ages in eucrites show that multiple large impacts occurred within 1 Gyr after crystallization, showing a history that largely resembles that of the Moon [5-7]. Dawn images also showed that Vesta is covered with a well-developed regolith that is spectrally similar to howardite meteorites [8]. Howardites are polymict regolith breccias made up mostly of clasts of eucrites and diogenites, but which also contain clasts formed by melting of the regolith by relatively large, energetic impact events. Impact-melt clast ages from howardites extend our knowledge of the impact history of Vesta, expanding on eucrite disturbance ages and helping give absolute age context to the observed crater-counts produced using Dawn data. The distribution of 40Ar-39Ar ages of impact-melt clasts in howardites shows that they formed within the time period 3.3-3.8 Ga [9]. These, and other impact-melted HED materials, have distinct age and compositional characteristics that suggest they formed in discrete impact events. In order to create these crystalline impact-melt products on the surface of Vesta, the impacts during this time period must have had velocities much higher than 5 km/s, the main belt average [10]. This is inconsistent with formation by a normal distribution of impact velocities and points instead to a unique period where high-velocity collisions were more frequent than currently observed. Until now, impact-reset ages in the HED meteorites have been be interpreted under the umbrella of the canonical lunar cataclysm where an increase in the absolute number of bombarding objects is responsible for creating larger absolute amounts of impact-affected and impact-melted rocks, statistically increasing their chances of being found on Earth and dated. However, the distribution of age among the howardite impact-melt clasts may not necessarily result from an increased number of impacts, but rather result from impacts of higher velocity. The changeover from a typical main belt velocity profile to this regime of increased velocity population at Vesta occurs contemporaneously with a similar transition at the Moon, indicating that howardite impact-melt clast ages reinforce the notion of a dynamically unusual episode of bombardment in the inner solar system beginning at around 4.0 Ga.

Cohen, B. A.↗

A Second Look at 12 Candidate Dual AGNs Using BAYMAX

We present an analysis of 12 optically selected dual active galactic nucleus (AGN) candidates at z < 0.34. Each candidate was originally identified via double-peaked [O III] λ5007 emission lines and received follow-up Chandra and Hubble Space Telescope (HST) observations. Because the X-ray data are low-count (<100 counts) with small separations (<1''), a robust analysis is necessary for classifying each source. Pairing long-slit [O III] observations with existing Chandra observations, we re-analyze the X-ray observations with Bayesian AnalYsis of AGNs in X-rays to determine whether the X-ray emission from each system is more likely a single or dual point source. We find that 4 of the 12 sources are likely dual X-ray point-source systems. We examine each point source's spectra via a Monte Carlo method that probabilistically identifies the likely origin of each photon. When doing so, we find that (i) the secondary X-ray point sources in two of the systems have L(X)< 10(exp 40) erg/s, such that we cannot rule out a non-AGN origin, (ii) one source has a secondary with L(X)> 10(exp 40) erg/s but a spectrum that is too soft to definitively preclude being X-ray emitting diffuse gas that was photoionized by the primary AGN, and (iii) one system (SDSS J1126+2944) is a dual AGN. Additionally, using complementary HST observations, we analyze a subsample of systems that are visually identified as merging. Our results suggest that dual AGNs may preferentially reside in mergers with small separations, consistent with both simulations and observations.

Adi Foord↗

Laser Communications Relay Demonstration Optimetrics Experiment

Within this paper, we report on an Optimetrics experiment conducted on the National Aeronautics and Space Administration (NASA) Laser Communication Relay Demonstration (LCRD). The high precision two-way ranging is conducted on the optical communications link between the LCRD space terminal in a geosynchronous orbit and the Optical Ground Station 1 (OGS1) at Table Mountain, California, and is referred to as optimetrics ranging. The receiver to transmitter clock loopback is implemented in the LCRD space modem. A digital dual mixer time difference phase meter (DDMTD) is implemented in the OGS1 ground modem. The round-trip time is measured with the DDMTD by counting the frame and data clock ticks between transmitter and receiver frame synchronization markers for coarse range, and the relative phase of the transmit and receive clock for high precision range. This approach provides coverage for all potential ranges with no ranging ambiguity. The flight modem FPGA code was modified for frame and data clock loopback and the OGS1 FPGA code was modified for the DDMTD phase meter implementation. The experiment team conducted a 36-hour continuous ranging measurement. Preliminary two-way optimetrics ranging data show a noise floor of 3cm (rms). Based on our theoretical noise analysis and ground tests with spare flight modems, we expected one order of magnitude improvement on ranging precision. We are conducting detailed post data processing to identify the differences to further reduce the noise level and formulating an improved implementation approach for future missions. For reference and comparison, traditional Radio Frequency (RF) ranging between LCRD and OGS1 was conducted at the same time and indicates a ranging noise floor of 30cm(rms). Other telemetry and relevant environmental parameters such as weather and atmosphere temperature were also collected for offline data processing. The high precision ranging and range rate measurements from the laser communications data link clock and clock phase are performed simultaneously with continuous optical communication. No extra hardware added to existing system. This high precision optimetrics measurement implementation provides alternative ranging and range rate measurements for orbit determination (OD) and flight dynamics calculations with higher precision. We see significant improvement on OD for navigation upon implementation in future optical communication systems.

Rafael Garcia↗

Storage of Ultracold Neutrons in the Magneto-Gravitational Trap of the UCN Experiment

The UCN experiment is designed to measure the lifetime n of the free neutron by trapping ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provides a background holding field to eliminate depolarization-induced UCN loss caused by magnetic field nodes. We present a measurement of the storage time store of the trap by storing UCN for various times and counting the survivors. The data are consistent with a single exponential decay, and we find store = 860 19 s, within 1 of current global averages for n. The storage time with the holding field deactivated is found to be store = 470 160 s; this decreased storage time is due to the loss of UCN, which undergo Majorana spin flips while being stored. We discuss plans to increase the statistical sensitivity of the measurement and investigate potential systematic effects.

Salvat, D. J.↗

Use of XRF to characterize pre-Hanford orchards in the 100-OL-1 operable unit - 15717

Prior to 1943, Hanford site included several small towns with approximately 5,000 acres of orchards; at the time lead arsenate (PbHAsO{sub 4}) was the most commonly used pesticide. High concentration of lead and arsenic have been recorded where trees and stumps are still visible. Pre-Hanford orchards have been designated as 100-OL-1 Operable Unit. An Optimization study evaluated optimal counting time and position of the XRF from soils collected at the site. A Pilot Study included the evaluation of a field portable x-ray fluorescence (XRF) analyzer determining if performance results meet quality assurance criteria for cleanup. XRF has only previously been used as a screening tool. Four Decision Units (DUs) are to be analyzed: Ol-14. OL-32. OL-IU6-4 and OL-FR2-1. The DUs vary in size and have had distinct historic activities; such as 46.4 acres OL-14 having a military camp in the 1950's unlike OL-FR2-1 having been disturbed as it is near the F area reactor. Together the DUs provide an adequate representation of the Operable Unit. Screening criteria for lead (250 mg/kg) and arsenic (20 mg/kg). Six samples were collected ranging above, at, and below the screening criteria of 250 mg/kg for Pb and 20 mg/kg for As at the Decision Units OL-14 and OL-IU6-4, and labeled respectively. Samples were hand sieved, homogenized and placed in sample cups. Three replicates were prepared for each sample. Each sample cup was analyzed 3 times for 30 sec. A Standard Reference Material (SRM) was analyzed after every 20 readings. Three samples were selected for 15, 30, 45, 60, 90, 120, 150 and 180 second fixed and variable analysis. Two transects at OL-14, and one at OL-IU6-4 were created by selecting locations 90. around ground zero at distances of 0.5, 1, 2, 4, 8 and 12 feet (16 ft for OL-14). Locations were scanned in triplicate for 60 seconds each. 4 Decision Units spanning roughly 370 acres were chosen to represent 100-OL-1 Operable Unit. 40 locations within each DU were selected using Visual Sample Plan (VSP) with a random start and systematic grid pattern. Each location would be analyzed with 3 replicates and a 60 second count time. The Standard Reference Material (SRM) and blank are analyzed after every 20 counts to ensure accuracy. Data is extracted from XRF to be implemented in GIS for visual representation of site with 1943 and 2013 aerial imagery. Discussion/Conclusion: - XRF provided a good indication of precision and accuracy relative to ICP with a linear correlation R{sup 2} value higher than anticipated at .9735; - MDL proved the detection limit is significantly lower than the screening criteria; - When comparing results from the first 40 locations of OL-14 to the total 80 locations of OL-14, the same variability was seen; - We expect high concentrations of Pb and As to be where past orchards are present though this does not occur as all sites. Significance: - XRF is competent for decision making as values fall within ±20% ICP data; - The highest concentrations are not where expected, which may be an issue for sites outside of Hanford that have had more development; - The size of the DU does not affect the number of samples measured. Future Work: - Verification and validation of the XRF Data (QA/QC); - Revise conceptual site model; - Statistical evaluations to investigate: Estimation of variability in surface soils, appropriate size for DU, and sample size per DU; - Coordinating sample results through CORE; - Displaying sample results in PHOENIX (GIS tool)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The compact neutron spectrometer at ASDEX Upgrade

The first neutron spectrometer of ASDEX Upgrade (AUG) was installed in November 2008. It is a compact neutron spectrometer (CNS) based on a BC501A liquid scintillating detector, which can simultaneously measure 2.45-MeV and 14-MeV neutrons emitted from deuterium (D) plasmas and {gamma} radiation. The scintillating detector is coupled to a digital pulse shape discrimination data acquisition (DPSD) system capable of count rates up to 10{sup 6} s{sup -1}. The DPSD system can operate in acquisition and processing mode. With the latter n-{gamma} discrimination is performed off-line based on the two-gate method. The paper describes the tests of the CNS and its installation at AUG. The neutron emission from the D plasma measured during a discharge with high auxiliary heating power was used to validate the CNS performance. The study of the optimal settings for the DPSD data processing to maximize the n-{gamma} discrimination capability of the CNS is reported. The CNS measured both 2.45-MeV and 14-MeV neutrons emitted in AUG D plasmas with a maximum count rate of 5.4 x10{sup 5} s{sup -1} (>10 times higher than similar spectrometers previously achieved) with an efficiency of 9.3 x 10{sup -10} events per AUG neutron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-G-17A-01: Innovative High-Performance PET Imaging System for Preclinical Imaging and Translational Researches

Purpose: To develop a practical and compact preclinical PET with innovative technologies for substantially improved imaging performance required for the advanced imaging applications. Methods: Several key components of detector, readout electronics and data acquisition have been developed and evaluated for achieving leapfrogged imaging performance over a prototype animal PET we had developed. The new detector module consists of an 8×8 array of 1.5×1.5×30 mm{sup 3} LYSO scintillators with each end coupled to a latest 4×4 array of 3×3 mm{sup 2} Silicon Photomultipliers (with ∼0.2 mm insensitive gap between pixels) through a 2.0 mm thick transparent light spreader. Scintillator surface and reflector/coupling were designed and fabricated to reserve air-gap to achieve higher depth-of-interaction (DOI) resolution and other detector performance. Front-end readout electronics with upgraded 16-ch ASIC was newly developed and tested, so as the compact and high density FPGA based data acquisition and transfer system targeting 10M/s coincidence counting rate with low power consumption. The new detector module performance of energy, timing and DOI resolutions with the data acquisition system were evaluated. Initial Na-22 point source image was acquired with 2 rotating detectors to assess the system imaging capability. Results: No insensitive gaps at the detector edge and thus it is capable for tiling to a large-scale detector panel. All 64 crystals inside the detector were clearly separated from a flood-source image. Measured energy, timing, and DOI resolutions are around 17%, 2.7 ns and 1.96 mm (mean value). Point source image is acquired successfully without detector/electronics calibration and data correction. Conclusion: Newly developed advanced detector and readout electronics will be enable achieving targeted scalable and compact PET system in stationary configuration with >15% sensitivity, ∼1.3 mm uniform imaging resolution, and fast acquisition counting rate capability for substantially improved imaging and quantification performance for small animal imaging and image-guided radiotherapy applications. This work was supported by a research award RP120326 from Cancer Prevention and Research Institute of Texas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Recursive Multi-step Machine Learning Approach for Airport Configuration Prediction

Airport configuration selection is a complex decision-making process that involves several operational and human factors. In this paper we propose a novel recursive multi-step machine learning (ML) approach to predict airport configuration. The multi-step approach guarantees stability of the predicted configuration by taking as input the configuration predicted at the previous time step. The features of the proposed model include weather data, future arrival and departure counts and current configuration. Due to the importance of arrival and departure counts in predicting the airport configuration, arrival counts are calculated using landing time predictions selected from physics-based landing time predictions available in FAA System Wide Information Management data feeds for each flight. The selection rules were developed and refined to select the most accurate time for different phases of flight. The proposed model predicts the airport configurations up to 6 hours ahead. In this paper we show the predictive performance of the proposed model for six major US airports, including Charlotte Douglas International Airport (CLT), Dallas/Fort Worth International Airport (DFW), John F. Kennedy International Airport (JFK), Newark Liberty International Airport (EWR), LaGuardia Airport (LGA) and Dallas Love Field Airport (DAL). We trained and evaluated models on 2019 and 2020 data in order to study the effect of the pandemic and how changes in traffic patterns affected the performance of the proposed model. Results are compared with a baseline assuming no airport configuration changes. In our results for DFW, we obtained a prediction accuracy of 89.3% for 3 hours ahead prediction, and 82.8% for 6 hours ahead when applied on 2019 data.

machine learning↗

A Recursive Multi-step Machine Learning Approach for Airport Configuration Prediction

Airport configuration selection is a complex decision-making process that involves several operational and human factors. In this paper we propose a novel recursive multi-step machine learning (ML) approach to predict airport configuration. The multi-step approach guarantees stability of the predicted configuration by taking as input the configuration predicted at the previous time step. The features of the proposed model include weather data, future arrival and departure counts and current configuration. Due to the importance of arrival and departure counts in predicting the airport configuration, arrival counts are calculated using landing time predictions selected from physics-based landing time predictions available in FAA System Wide Information Management data feeds for each flight. The selection rules were developed and refined to select the most accurate time for different phases of flight. The proposed model predicts the airport configurations up to 6 hours ahead. In this paper we show the predictive performance of the proposed model for six major US airports, including Charlotte Douglas International Airport (CLT), Dallas/Fort Worth International Airport (DFW), John F. Kennedy International Airport (JFK), Newark Liberty International Airport (EWR), LaGuardia Airport (LGA) and Dallas Love Field Airport (DAL). We trained and evaluated models on 2019 and 2020 data in order to study the effect of the pandemic and how changes in traffic patterns affected the performance of the proposed model. Results are compared with a baseline assuming no airport configuration changes. In our results for DFW, we obtained a prediction accuracy of 89.3% for 3 hours ahead prediction, and 82.8% for 6 hours ahead when applied on 2019 data.

machine learning↗

Star counts as an indicator of galactic structure and quasar evolution

A detailed model of the stellar content of the Galaxy is described briefly. Illustrative applications of the model are made, using existing data, to indicate how star counts can be used to determine some parameters of galactic structure, to detect a massive (stellar) halo, and to constrain models of quasar evolution.

Bahcall, J. N.↗

Modeling longitudinal INMA(1) with COM–Poisson innovation under non-stationarity: application to medical data

This paper introduces an observation-driven (OD) longitudinal integer-valued moving average model of order 1 (INMA(1)) with COM–Poisson innovations under non-stationary moment conditions. This new longitudinal model provides lot of practical flexibility in terms of modeling a wide range of over-, under-dispersion and any mixed level of dispersion. In this set-up, the model parameters of primary interest consist of the regression and dispersion effects while the serial autocorrelation parameters are treated as nuisance. A robust Generalized Quasi-Likelihood approach is formulated to estimate the different set of parameters. The performance of the estimating algorithm is assessed via Monte Carlo experiments under various combination of the serial and dispersion values and is compared with the existing adaptive generalized method of moments. Application to two medical data: epileptic seizures and polyposis counts are also illustrated.

97 MATHEMATICS AND COMPUTING↗

Open-Source Data Analysis Tool for Spectral Small-Angle X-ray Scattering Using Spectroscopic Photon-Counting Detector

Spectral small-angle X-ray scattering (sSAXS) is a powerful technique for material characterization from thicker samples by capturing elastic X-ray scattering data in angle- and energy-dispersive modes at small angles. This approach is enabled by the use of a 2D spectroscopic photon-counting detector that provides energy and position information of scattered photons when a sample is irradiated by a polychromatic X-ray beam. Here, we describe an open-source tool with a graphical interface for analyzing sSAXS data obtained from a 2D spectroscopic photon-counting detector with a large number of energy bins. The tool takes system geometry parameters and raw detector data to output 1D scattering patterns and a 2D spatially-resolved scattering map in the energy range of interest. We validated these features using data from samples of caffeine powder with well-known scattering peaks. This open-source tool will facilitate sSAXS data analysis for various material characterization applications.

Chemistry↗

Extinction Monitoring of Pulsed Proton Beams Using FPGA-Based Peak Detection

The Mu2e experiment at Fermilab imposes stringent requirements on the elimination of out-of-time beam in its pulsed proton beam - a requirement known as "extinction". We present a method to measure the out-of-time particle rates to calculate the level of extinction in the inter-pulse gaps. The proposed method utilizes an array of quartz Cherenkov radiators and photomultiplier tubes to detect particles scattered from a vacuum chamber in the M4 transfer beamline at Fermilab.The measurement will employ a new μTCA-based FPGA system for data acquisition and signal processing, utilizing real-time peak detection algorithms to count scattered beam particles. By integrating data over many transfers, the time profile of the out-of-time beam will be resolved to fractional levels relative to that of the in-time beam. These results are compared with G4beamline simulations to validate models of beam transport, dynamics, and extinction, providing critical input for optimizing beam delivery to Mu2e.

Hensley, Ryan [UC, Davis]↗