Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Real-time gas cooling of flowing liquid lithium limiter for the EAST

A novel continuously flowing liquid lithium limiter (FLiLi) which employs an in-vessel electro-magnetic pump to drive liquid Li flowing on the surface of limiter has been successfully designed and tested in the experimental advanced superconducting tokamak (EAST) device in 2014. In order to better control the surface temperature, an upgraded design and the real-time gas cooling were performed in 2016. Two kinds of cooling gas, helium (He) and argon (Ar) were tested on the FLiLi system prior to the experiment. It was found that the cooling rates of He and Ar at 2.5 MPa are 34.2 °C/min, 10.2 °C/min or 31.7 °C/kL and 28.1 °C/kL, respectively. The cooling performance of He is more effective than Ar. Experimental results show that the real-time He cooling could effectively contain the FLiLi surface temperature increase and prevent the strong passive evaporation of lithium during plasma discharges. Limiter heat flux up to 0.2 MW/m2 was removed during ohmic discharge with 2.5 MPa He gas. Finally, Because of the upgraded design and real-time gas cooling, the surface of FLiLi was not damaged by heat flux after entire plasma discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring the Potential of Rainwater Harvesting for Cooling Towers: A Systematic Review and Regional Feasibility Assessment

Water scarcity has driven interest in rainwater harvesting, especially for U.S. industries like power and manufacturing, which dedicate a large percentage of their water needs to cooling towers. This paper provides a comprehensive systematic review of studies on the use of rainwater in cooling tower applications, along with an assessment of the regional feasibility of integrating RWH in U.S. manufacturing cooling towers. The systematic review examines the technical, economic, environmental, and policy feasibility of utilizing harvested rainwater, and the regional feasibility analysis evaluates the practical implementation of RWH in manufacturing cooling towers, considering factors such as regional RWH potential, water costs, state policies, and the industrial water use of manufacturing facilities per state. This study supports the hypothesis that RWH for cooling towers is technically feasible, economically viable, and environmentally beneficial. Harvested rainwater is naturally less conductive and soft, and rainwater reuse minimizes the ecological footprint. Supportive state policies, regional RWH potential, and rising water costs across the U.S. are important variables that may impact RWH adoption. The review highlights rooftop RWH as the most studied method and notes that implementing RWH requires infrastructure changes and filtration techniques. While initial investment costs may be high, operational and maintenance costs are low, making RWHS economically feasible over time. Regions with higher water costs and supportive policies are more likely to benefit from RWH adoption. The study provides a foundation for understanding the potential for using RWH in industrial cooling towers.

Cooling towers↗

Design and evaluation of an open-source, conformable skin-cooling system for body magnetic resonance guided focused ultrasound treatments

Magnetic resonance guided focused ultrasound (MRgFUS) treatment of tumors uses inter-sonication delays to allow heat to dissipate from the skin and other near-field tissues. Despite inter-sonication delays, treatment of tumors close to the skin risks skin burns. This work has designed and evaluated an open-source, conformable, skin-cooling system for body MRgFUS treatments to reduce skin burns and enable ablation closer to the skin. A MR-compatible skin cooling system is described that features a conformable skin-cooling pad assembly with feedback control allowing continuous flow and pressure maintenance during the procedure. System performance was evaluated with hydrophone, phantom and in vivo porcine studies. Sonications were performed 10 and 5 mm from the skin surface under both control and forced convective skin-cooling conditions. 3D MR temperature imaging was acquired in real time and the accumulated thermal dose volume was measured. Gross analysis of the skin post-sonication was further performed. Device conformability was demonstrated at several body locations. Hydrophone studies demonstrated no beam aberration, but a 5–12% reduction of the peak pressure due to the presence of the skin-cooling pad assembly in the acoustic near field. Phantom evaluation demonstrated there is no MR temperature imaging precision reduction or any other artifacts present due to the coolant flow during MRgFUS sonication. The porcine studies demonstrated skin burns were reduced in size or eliminated when compared to the control condition. An open-source design of an MRgFUS active skin cooling system demonstrates device conformability with a reduction of skin burns while ablating superficial tissues.

60 APPLIED LIFE SCIENCES↗

Experimental Demonstration of Hadron Beam Cooling Using Radio-Frequency Accelerated Electron Bunches

Cooling of beams of gold ions using electron bunches accelerated with radio-frequency systems was recently experimentally demonstrated in the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. Such an approach is new and opens the possibility of using this technique at higher energies than possible with electrostatic acceleration of electron beams. The challenges of this approach include generation of electron beams suitable for cooling, delivery of electron bunches of the required quality to the cooling sections without degradation of beam angular divergence and energy spread, achieving the required small angles between electron and ion trajectories in the cooling sections, precise velocity matching between the two beams, high-current operation of the electron accelerator, as well as several physics effects related to bunched-beam cooling. Here we report on the first demonstration of cooling hadron beams using this new approach.

43 PARTICLE ACCELERATORS↗

SiC and GaN Devices With Cryogenic Cooling

This article presents the cryogenically cooled application for wide bandgap (WBG) semiconductor devices. Characteristics of silicon carbide (SiC) and gallium nitride (GaN) at cryogenic temperatures are illustrated. SiC MOSFETs exhibit increased on-state resistance and slower switching speed at cryogenic temperatures. However, cryogenic cooling provides low ambient temperature environment and thus enables the SiC converter to operate at lower junction temperature to achieve higher efficiency compared to room temperature cooling. A cryogenically cooled MW-level SiC inverter prototype is developed and demonstrated the feasibility of operating high-power SiC converter with cryogenic cooling. GaN HEMTs exhibit more than five times on-state resistance reduction and faster switching speed at cryogenic temperatures which makes GaN HEMTs an excellent candidate for cryogenic power electronics applications. The significantly reduced on-state resistance of GaN devices provides the possibility to operate them at a current level much higher than rated current at cryogenic temperatures. A GaN double pulse test (DPT) circuit is constructed and demonstrated that GaN HEMTs can operate at nearly four times of rated current at cryogenic temperatures. Challenges of utilizing WBG device with cryogenic cooling are discussed and summarized.

42 ENGINEERING↗

R&D toward a proof-of-principle experiment on optical stochastic cooling at the Fermilab’s IOTA ring

The stochastic-cooling method was invented in the late 70s and played a key role in the accumulation of intense beams of antiprotons for a head-on collision with counter rotating proton beams at 500 GeV in the Super Proton Synchrotron (SPS) at CERN. Such an improvement led to the discovery of the W and Z bosons in 1983. In brief, stochastic cooling relies on recording information (position) associated with short longitudinal slices within the bunch. The radiation is encoded on a radiofrequency (RF) signal, manipulated and used to correct the bunch slices at a later time.The repetitive correction is applied as the beam circulates in the ring ultimately cool the beam.Stochastic cooling has been successfully implemented in several machines for particle cooling and accumulation. Cooling of bunched beams in proton-(anti)proton colliders was challenging due to the high phase-space density of the bunches but was recently demonstrated at the Relativistic Heavy Ion Collider (RHIC).

43 PARTICLE ACCELERATORS↗

An Overview of Non-LWR Vessel Cooling Systems for Passive Decay Heat Removal (Technical Letter Final Report)

The following report provides a technical review of various reactor vessel cooling system (VCS) concepts under consideration for decay heat removal (DHR) in non-light water advanced reactor designs. This review focuses on ex-vessel designs, including the Reactor Cavity Cooling System (RCCS), the Reactor Vessel Auxiliary Cooling System (RVACS), and hybrid iterations, using both air and water cooling to achieve their heat removal function. Based on a literature review of publicly available sources published between 1979 and 2021, a technical summary is presented detailing existing and planned VCS design options, their applicability to specific reactor type, and review of authored research and development studies. Following an assessment of the availability of data and modeling tools, an evaluation was performed analyzing their likely performance during normal, degraded, and accident conditions, including reliability, stability, and longevity. With renewed consideration of air-based DHR systems by some US vendors, there is a need to fully understand the complexities inherent to natural circulation systems, and more importantly, how they may influence safety-related heat removal functions and system performance. For DHR systems that rely on air-based mode of cooling, this entails quantification of the impacts of low flow conditions during start-up, relative elevations of inlet and outlet ducts for below-grade installations, effects of the use of multiple parallel chimneys for redundancy, and impact of weather conditions at the plant site. For systems relying on water-based mode cooling, reliance on limited coolant inventory in an event of pipe break or extended duration accident scenarios, sensitivities related to stability of boiling flow and heat transfer conditions, and quantification of full-scale structural vibrations on balance of plant structures are among the complicating factors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Studies of Conventional and ERL-Based Re-Circulator Electron Cooling for an Electron Ion Collider (Final Report)

The envisioned Electron Ion Collider will be comprised of a chain of accelerators, each employing electron cooling. Depending on the purpose, each accelerator will employ some form of electron cooling: conventional DC type, Energy Recovering Linac-based recirculator, or coherent electron cooling. Each electron cooling type has its own peculiarities that need to be studied, understood, and their performance optimized to maximize luminosity; these are the subjects of this project. In particular, we developed the first microscopic electron cooling modeling and simulation framework that was also benchmarked against experiment. We proved for the first time the feasibility of first principle, accurate and efficient electron cooling simulations with a minimal number of assumptions and approximations that match empirical studies.

43 PARTICLE ACCELERATORS↗

Real-Time Closed Loop Modulated Turbine Cooling

It has been noted by industry that in addition to dramatic variations of temperature over a given blade surface, blade-to-blade variations also exist despite identical design. These variations result from manufacturing variations, uneven wear and deposition over the life of the part as well as limitations in the uniformity of coolant distribution in the baseline cooling design. It is proposed to combine recent advances in optical sensing, actuation, and film cooling concepts to develop a workable active, closed-loop modulated turbine cooling system to improve by 10 to 20 the turbine thermal state over the flight mission, to improve engine life and to dramatically reduce turbine cooling air usage and aircraft fuel burn. A reduction in oxides of nitrogen (NOx) can also be achieved by using the excess coolant to improve mixing in the combustor especially for rotorcraft engines. Recent patents filed by industry and universities relate to modulating endwall cooling using valves. These schemes are complex, add weight and are limited to the endwalls. The novelty of the proposed approach is twofold 1) Fluidic diverters that have no moving parts are used to modulate cooling and can operate under a wide range of conditions and environments. 2) Real-time optical sensing to map the thermal state of the turbine has never been attempted in realistic engine conditions.

turbines↗

Thermospheric Nitric Oxide Cooling Responses to the 14 December 2020 Solar Eclipse

The behaviors of the nitric oxide (NO) cooling in the lower thermosphere during the 14 December 2020 solar eclipse are studied using Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) measurements and WACCM-X simulations. We found that NO cooling rate decreases during the solar eclipse in both SABER measurements and WACCM-X simulations. The maximum decrease of the NO cooling is 40% in SABER measurements and 25% in WACCM-X simulations. The NO cooling process is initiated almost entirely through the collisions with atomic oxygen (O) which depends linearly on NO and O densities and non-linearly on the neutral temperature. During the eclipse, the NO concentration and temperature decreases are larger than that of O concentration. Consequently, the eclipse-time NO concentration and temperature decreases are the major drivers of the NO cooling rate decrease. The decreases of the temperature and the NO concentration contribute comparably to the eclipse-time NO cooling rate decrease.

solar eclipse↗

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Clean Water Production in Cooling Towers

This project developed and demonstrated a novel technology that produces clean water from cooling tower recirculating water by using the natural evaporation and condensation cycle inside cooling towers. The system captures the escaping plume and converts blowdown quality water into high purity water suitable for on-site reuse such as boiler feed. The technology uses electric fields to ionize exhaust plumes, charge the entrained droplets, and direct them toward collection electrodes where they coalesce and flow downward. This allows water recovery at a low energy cost while reducing visible plume emissions. In addition, we developed a complementary software platform that improves overall cooling tower performance. The system uses wireless sensors and physics-based machine learning algorithms to optimize key parameters of the cooling process. For power generation facilities, this increases the thermal efficiency of the cooling loop and condenser, resulting in measurable cycle efficiency gains. Improvements of one percent or more can deliver significant increases in electricity production for the same fuel input.

01 COAL, LIGNITE, AND PEAT↗

Influence of interrupted cooling on the development of bimodal γ' precipitate distributions in ATI 718Plus

The influence of aging treatments on the evolution of the γ' precipitates in ATI 718Plus was studied using scanning electron microscopy, energy dispersive spectroscopy, transmission electron microscopy, and atomic probe tomography. A set of aging treatments was performed on solution-treated samples to obtain various γ' size distributions. The aging temperatures ranged from 720 to 900°C with holding times of either two hours (for the 900°C aging temperature) or 10 h (for the 720°C and 750°C aging temperatures) followed by either air cooling, furnace cooling, or water quenching. The cooling method and aging temperature influenced the distribution of the solute elements. This work discussed the evolution of the γ' precipitation during single-step aging and two-step aging involving continuous cooling or interrupted cooling. Finally, a bimodal size distribution of the γ' precipitates was obtained through interrupted cooling two-step aging treatments, while single-step aging resulted in unimodal γ' precipitate distributions.

36 MATERIALS SCIENCE↗

Critical cooling rates for amorphous-to-ordered complexion transitions in Cu-rich nanocrystalline alloys

Amorphous complexions in nanocrystalline metals have the potential to improve mechanical properties and radiation tolerance, as well as resistance to grain growth. In this study, the stability of amorphous complexions in binary and ternary Cu-based alloys is investigated by observing the effect of cooling rate from high temperature on the occurrence of amorphous-to-ordered complexion transitions. Bulk Cu-Zr and Cu-Zr-Hf alloy samples were annealed to induce boundary premelting and then quenched through a procedure that induces a gradient of local cooling rate through the sample height. Amorphous complexion thickness distributions were found to be invariant to local cooling rate in the Cu-Zr-Hf alloy, demonstrating enhanced stability of the amorphous complexion structure compared to the Cu-Zr alloy, which had thinner amorphous complexions in the regions that were slowly cooled. The experimental results are used to construct time-temperature-transformation diagrams for the amorphous-to-ordered complexion transition in both the binary and ternary alloys, enabling a deeper understanding of the influence of cooling rate and grain boundary chemistry on complexion transitions. In conclusion, the critical cooling rate necessary to avoid complexion transitions in the ternary alloy is found to be at least three orders of magnitude slower than that for the binary alloy.

36 MATERIALS SCIENCE↗

Bifunctional Asymmetric Fabric with Tailored Thermal Conduction and Radiation for Personal Cooling and Warming

Personal thermal management is emerging as a promising strategy to provide thermal comfort for the human body while conserving energy. By improving control over the heat dissipating from the human body, personal thermal management can provide effective personal cooling and warming. Here, we propose a facile surface modification approach to tailor the thermal conduction and radiation properties based on commercially available fabrics, to realize better management of the whole heat transport pathway from the human body to the ambient. Additionally, a bifunctional asymmetric fabric (BAF) offering both a cooling and a warming effect is demonstrated. Due to the advantages of roughness asymmetry and surface modification, the BAF demonstrates an effective cooling effect through enhanced heat conduction and radiation in the cooling mode; in the warming mode, heat dissipation along both routes is reduced for personal warming. As a result, a 4.6 °C skin temperature difference is measured between the cooling and warming BAF modes, indicating that the thermal comfort zone of the human body can be enlarged with one piece of BAF clothing. We expect this work to present new insights for the design of personal thermal management textiles as well as a novel solution for the facile modification of available fabrics for both personal cooling and warming.

42 ENGINEERING↗

A review of challenges, barriers, and opportunities for large-scale deployment of cool surfaces

Major urban centers are warming due to a combination of global and local phenomena. City governments are increasingly adopting strategies to mitigate the causes and impacts of extreme heat on their populations. Among these strategies are high solar-reflectance (cool) surfaces installed on building roofs and walls. Use of cool surfaces is a cost-effective and simple strategy that replaces conventional darker surfaces with surfaces that have a high reflectance to shortwave (solar) energy. This report reviews the recent history of cool-surface deployment efforts. This includes peer-reviewed literature, conference proceedings, and grey literature to identify challenges and barriers to wide-scale deployment of cool surfaces. We have also researched heat action plans and programs from cities and different codes and standards, as well as available incentive and rebate programs. The review identifies challenges, barriers, and opportunities associated with large-scale deployment of cool surfaces and categorize them broadly as being related to product development & performance or policies & mandates. It provides a foundation upon which we intend to build a roadmap for rapidly accelerating future deployments of cool surfaces. Finally, this roadmap will address identified challenges and incorporate lessons learned from historical efforts to generate a practical and actionable plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooling performance of an active-passive hybrid composite phase change material (HcPCM) finned heat sink: Constant operating mode

Here, the present study explores a hybrid thermal management technology based on air cooling and hybrid composite phase change material (HcPCM) filled finned heat sink for cooling performance of lower to medium heat flux dissipating electronic devices. Two-dimensional numerical simulations are conducted to study the conjugate heat transfer effects of three types of finned heat sink: air-cooled finned heat sink, HcPCM-cooled finned heat sink, and hybrid (air-HcPCM) cooled finned heat sink. A heat sink with a constant volume faction of plate-fins is designed in all cases and simultaneous effects of hybrid nanoparticles and air are investigated to keep the heat sink temperature at safe operating conditions between 40–60°C. The effect of air is incorporated into the heat sink by applying the convective heat transfer coefficient of h c = 10–100W /m 2 .K which tends to create the natural convection and forced convection heat transfer characteristics. The heat flux is varied from 25–40kW /m 2 in the current study. The hybrid nanoparticles of carbon additives (GO and MWCNTs) are dispersed into the RT-35HC, used as a PCM, with a volume fraction of 0% to 6%. Transient simulations are carried out using COMSOL Multiphysics to solve the governing equations for PCM based conjugate heat transfer model. The results showed that forced convection heat transfer improved the cooling performance of the hybrid heat sink compared to natural convection heat transfer. The addition of nanoparticles further enhanced thermal enhancement and uniform melting distribution of PCM inside the finned heat sink. The h c between 30 to 50W/m 2 .K shows optimized values for forced convection heat transfer operating conditions. The volume fraction of 2% of GO+MWCNTs nanoparticles in recommended or optimum concentration for uniform melting of PCM inside the finned heat sink.

36 MATERIALS SCIENCE↗

Review of condensed matter laser cooling using electric-dipole-allowed transitions

The cooling of solids via laser-excited anti-Stokes luminescence has reached the cryogenic regime and is now being considered for several applications that benefit from vibration-free cryogenic refrigeration. 4f-4f transitions in rare-earth-doped crystals with low phonon energies currently offer the best laser-cooling performance. These transitions, however, are electric-dipole (ED) forbidden and thus have low cross sections, limiting the minimum achievable temperatures in practical materials to the 50–100 K regime. In contrast, ED-allowed transitions may offer greater cross sections and potentially enable lower minimum temperatures or more compact devices. The search for laser cooling with ED-allowed transitions has been an active field of research over the past decades with a wide variety of materials having been studied. This paper reviews the fundamentals of solid-state laser cooling, provides a preliminary theoretical assessment showing that laser-cooling with ED-allowed transitions is in principle possible, and reviews the experimental results reported to date. While cooling with ED-allowed transitions has not yet been realized in the solid state, the existing experimental body of work along with the theoretical considerations presented here suggest that further research on this topic may be fruitful.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗