Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controlled humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Packaged SMIP Smart Connector for Ectron Computers

The project provides appropriate software modules, which allow to represent a physical oven as a virtual oven model. For that a virtual oven model is developed, which defines oven parameters like temperature, power consumption but also the door status and the humidity. To connect a real oven to the virtual model for monitoring and control multiple sensors are used to collect data. Using a MQTT based data connection the measured parameters are send to the CESMII environment for further processing and monitoring. Within this project the CESMII model for the general oven was developed and provided. Further the sensors were connected to the actual oven. The sensor data is collected via means of a MQTT based data transfer protocol to a gateway module. The gateway module then translates and transfers the collected data to the actual CESMII oven model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tailoring Fibre Structure Enabled by X-ray Analytics for Targeted Biomedical Applications

The rising interest in designing fibres via spinning techniques combining the properties of various polymeric materials into advanced functionalised materials is directed towards targeted biomedical applications such as drug delivery, wearable sensors or tissue engineering. Understanding how these functional polymers exhibit multiscale structures ranging from the molecular level to nano-, micro-and millimetre scale is a key prerequisite for their challenging applications that can be addressed by a non-destructive X-ray based analytical approach. X-ray multimodalities combining X-ray imaging, scattering and diffraction allow the study of morphology, molecular structure, and the analysis of nano-domain size and shape, crystallinity and preferential orientation in 3D arrangements. The incorporation of X-ray analytics in the design process of polymeric fibers via their nanostructure under non-ambient conditions (i.e. temperature, mechanical load, humidity…) allows for efficient optimization of the fabrication process as well as quality control along the product lifetime under operating environmental conditions. Here, we demonstrate the successful collaboration between the laboratory of Biomimetic Textiles and Membranes and the Center of X-ray Analytics at Empa for the design, characterisation and optimisation of advanced functionalised polymeric fibrous material systems.

60 APPLIED LIFE SCIENCES↗

A portable personal cooling system for mine rescue operations

Design of a portable personal cooling system to reduce physiological stress in high-temperature, high-humidity conditions is discussed. The system, based on technology used in the thermal controls of space suits, employs a combination of head and thoracic insulation and cooling through a heat sink unit. Average metabolic rates, heart rates, rectal temperature increase and sweat loss were monitored for test subjects wearing various configurations of the cooling system, as well as for a control group. The various arrangements of the cooling garment were found to provide significant physiological benefits; however, increases in heat transfer rate of the cooling unit and more effective insulation are suggested to improve the system's function.

Webbon, B.↗

Space flight printed wiring board measling investigation

A flight printed wiring board (PWB) for a satellite project was observed to have a high incidence of measling. Other PWB's produced for the program by the same manufacturer did not exhibit the degree of measling as did the 'measle-prone' board. Measling susceptibility during hand soldering and measling effects on PWB insulation resistance were investigated for three production PWB's. Measling resistance was significantly different between the three boards: the 'worst' exhibited five times the number of measles as the 'best' board. 'Severe' measling (that which is likely to affect board reliability) did not exist on the 'best' board, even under extreme soldering conditions (399 degrees C for 12-15 sec.), whereas the 'worst' board showed an average of one 'severe' measle for every two pads under more normal soldering conditions (288-343 degrees C for 2-5 sec.). Both soldering time and temperature affected measling, with time having a slightly greater influence (2 percent versus 12 percent). Measling effects on PWB insulation resistance were inconclusive. These were evaluated by in situ resistance measurements on the same three boards at elevated temperature and humidity. The measured resistance for all three boards decreased for exposures greater than 50 degrees C and 50 percent relative humidity. The 'measle-prone' board showed a resistance decrease at only 25 degrees C and 50 percent relative humidity. However, no definitive difference was detected between measled and not-measled (control) samples. The boards evaluated were production boards, so the effect of interlayer traces connecting the plated-through holes was not controlled. It is likely the resistance measurements were over different volumes of PWB laminate, which would account for the widely varying resistances measured. Thermomechanical measurements on board laminate materials did not reveal any differences attributed to measling. Differences in glass transition temperature were significantly different when measured by DTA, but not by SDT. Laminate thermal expansion differences were significant for the 35 degrees C evaluations, but not for any higher temperatures.

Thomas, Walter B., III↗

Statistical Quality Control of Moisture Data in GEOS DAS

A new statistical quality control algorithm was recently implemented in the Goddard Earth Observing System Data Assimilation System (GEOS DAS). The final step in the algorithm consists of an adaptive buddy check that either accepts or rejects outlier observations based on a local statistical analysis of nearby data. A basic assumption in any such test is that the observed field is spatially coherent, in the sense that nearby data can be expected to confirm each other. However, the buddy check resulted in excessive rejection of moisture data, especially during the Northern Hemisphere summer. The analysis moisture variable in GEOS DAS is water vapor mixing ratio. Observational evidence shows that the distribution of mixing ratio errors is far from normal. Furthermore, spatial correlations among mixing ratio errors are highly anisotropic and difficult to identify. Both factors contribute to the poor performance of the statistical quality control algorithm. To alleviate the problem, we applied the buddy check to relative humidity data instead. This variable explicitly depends on temperature and therefore exhibits a much greater spatial coherence. As a result, reject rates of moisture data are much more reasonable and homogeneous in time and space.

Dee, D. P.↗

Impact of CAMEX-4 Data Sets for Hurricane Forecasts using a Global Model

This study explores the impact on hurricane data assimilation and forecasts from the use of dropsondes and remote-sensed moisture profiles from the airborne Lidar Atmospheric Sensing Experiment (LASE) system. We show that the use of these additional data sets, above those from the conventional world weather watch, has a positive impact on hurricane predictions. The forecast tracks and intensity from the experiments show a marked improvement compared to the control experiment where such data sets were excluded. A study of the moisture budget in these hurricanes showed enhanced evaporation and precipitation over the storm area. This resulted in these data sets making a large impact on the estimate of mass convergence and moisture fluxes, which were much smaller in the control runs. Overall this study points to the importance of high vertical resolution humidity data sets for improved model results. We note that the forecast impact from the moisture profiling data sets for some of the storms is even larger than the impact from the use of dropwindsonde based winds.

Kamineni, Rupa↗

Advanced Plant Habitat (APH)

The Advanced Plant Habitat (APH) hardware will be a large growth volume plant habitat, capable of hosting multigenerational studies, in which environmental variables (e.g., temperature, relative humidity, carbon dioxide level light intensity and spectral quality) can be tracked and controlled in support of whole plant physiological testing and Bio-regenerative Life Support System investigations.

Plant↗

Thrust Measurement of Dielectric Barrier Discharge (DBD) Plasma Actuators: New Anti-Thrust Hypothesis, Frequency Sweeps Methodology, Humidity and Enclosure Effects

We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust, or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a grounded large-diameter metal sleeve. Strong dependence on humidity is also shown; the thrust significantly increased with decreasing humidity, e.g., 44 percent increase as relative humidity changed from 18 percent and dew point 33 degF to 50 percent and dew point of 57 degF.

Ashpis, David E.↗

Physical Mechanisms Controlling Upper Tropospheric Water Vapor as Revealed by MLS Data from UARS

The seasonal changes of the upper tropospheric humidity are studied with the water vapor data from the Microwave Limb Sounder on the NASA Upper Atmosphere Research Satellite, and the winds and vertical velocity data obtained from the European Centre for Medium-Range Weather Forecasts. Using the same algorithm for vertical transport as that used for horizontal transport (Zhu and Newell, 1998), we find that the moisture in the tropical upper troposphere may be increased mainly by intensified local convection in a small portion, less than 10%, of the whole area between 40 deg S to 40 deg N. The contribution of large scale background circulations and divergence of horizontal transport is relatively small in these regions. These dynamic processes cannot be revealed by the traditional analyses of moisture fluxes. The negative feedback suggested by Lindzen (1990) also exists, if enhanced convection is concentrated in the tropics, but is apparently not the dominant process in the moisture budget.

Newell, Reginald E.↗

End-Use Savings Shapes: Measure Documentation: Add Exhaust Air Heat/Energy Recovery

This documentation focuses on a single end-use savings shape measure—Add Exhaust Air Heat/Energy Recovery. This measure adds exhaust air energy recovery or heat recovery to existing air handling units (AHU) with outdoor air. Systems that already have energy/heat recovery are not modified. Furthermore, food service building types are also not modified by this measure due to the added complication of integrating cooking hood exhaust that could cause heat exchanger fouling from kitchen exhaust. In total, this measure is applicable airloops serving ~70% of the floor area in ComStock. In practice, energy/heat recovery systems are retrofitted to existing air delivery systems either as separate systems that provide outdoor air to the AHUs or are directly integrated to an AHU; the modeling approach used in this study is agnostic of the energy recovery type and simply accounts recovery effectiveness, added static pressure, and other controls which are described further in this document. Energy recovery with sensible and latent exchange gets added in humid climate zones, while heat recovery with sensible-only exchange gets added in drier climate zones. Energy recovery is modeled as a fixed membrane plate counterflow heat exchanger, while heat recovery is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and electric resistance preheat coil for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combining Mass Spectrometry of Picoliter Samples with a Multicompartment Electrodynamic Trap for Probing the Chemistry of Droplet Arrays

Single droplet levitation provides contactless access to the microphysical and chemical properties of micrometer-sized samples. Most applications of droplet levitation to chemical and biological systems use nondestructive optical techniques to probe droplet properties. To provide improved chemical specificity, we coupled a multicompartment quadrupole electrodynamic trap (QET) with single droplet mass spectrometry. Our QET continuously traps a monodisperse droplet population (tens to hundreds of droplets) and allows for the simultaneous sizing of a single droplet using its Mie scattering pattern. Single droplets are subsequently ejected into the ionization region of an ambient pressure inlet mass spectrometer. We optimized two complementary soft ionization techniques for picoliter aqueous droplets: (1) paper spray (PS) ionization and (2) thermal desorption glow discharge (TDGD) ionization. Both techniques detect oxygenated organic acids in single droplets, with signal-to-noise ratios >100 and detection limits on the order of 10 pg. Sensitivity and reproducibility across single droplets are driven by the droplet deposition location and spray stability in PS-MS and the ionization region humidity and analyte evaporation rate in TDGD-MS. Importantly, the analyte evaporation rate can control the TDGD-MS quantitative capability because high evaporation rates result in significant ion suppression. Additionally, this effect is mitigated by optimizing the vaporization temperature, droplet size range, and analyte volatility. We demonstrate quantitative and reproducible measurements with a droplet internal standard (<10% RSD) and compare the sensitivity of PS-MS and TDGD-MS. Finally, we demonstrate the application of QET-MS to the study of heterogeneous chemical kinetics with the reaction of gas phase O 3 and aqueous maleic acid droplets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast, high sensitivity dewpoint hygrometer

A dewpoint/frostpoint hygrometer that uses a surface moisture-sensitive sensor as part of an RF oscillator circuit with feedback control of the sensor temperature to maintain equilibrium at the sensor surface between ambient water vapor and condensed water/ice. The invention is preferably implemented using a surface acoustic wave (SAW) device in an RF oscillator circuit configured to generate a condensation-dependent output signal, a temperature sensor to measure the temperature of the SAW device and to distinguish between condensation-dependent and temperature-dependent signals, a temperature regulating device to control the temperature of the SAW device, and a feedback control system configured to keep the condensation-dependent signal nearly constant over time in the presence of time-varying humidity, corrected for temperature. The effect of this response is to heat or cool the surface moisture-sensitive device, which shifts the equilibrium with respect to evaporation and condensation at the surface of the device. The equilibrium temperature under feedback control is a measure of dewpoint or frostpoint.

Hoenk, Michael E.↗

Diurnal temperature fluctuation effects on potatoes grown with 12 hr photoperiods

This study was designed to characterize the growth responses of potato (Solanum tuberosum L.) to diurnal temperature fluctuations. Potato plants of two cultivars, Norland and Denali, were grown for 90 days under 12 hr photoperiod in walk-in growth rooms at the University of Wisconsin Biotron. The alternating temperature was 22 C light/14 C dark and compared to a constant 18 C as control. At all temperature regimes vapor pressure deficit was maintained at 0.62 kPa (70% relative humidity [correction of humdidity] at 18 C). Plant height, plant dry weight, tuber dry weight, and harvest index were overall greater under the warm light/cool dark alternating temperatures than under the constant temperature. The differences between temperature treatments were greater for Denali than for Norland. Alternating temperatures increased Denali tuber weights by 25%, but no significant increase was found with Norland. Also the total plant weight was increased over 20% with Denali, but increased with Norland in only one of the two replications of the experiment. This study documents that alternating temperatures are a benefit to some cultivars but may not be of benefit to all cultivars.

NASA Discipline Number 61-10↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Accelerated/abbreviated test methods, study 4 of task 3 (encapsulation) of the low-cost silicon solar array project

Inherent weatherability is controlled by the three weather factors common to all exposure sites: insolation, temperature, and humidity. Emphasis was focused on the transparent encapsulant portion of miniature solar cell arrays by eliminating weathering effects on the substrate and circuitry (which are also parts of the encapsulant system). The most extensive data were for yellowing, which were measured conveniently and precisely. Considerable data also were obtained on tensile strength. Changes in these two properties after outdoor exposure were predicted very well from accelerated exposure data.

Kolyer, J. M.↗

A Dye-Tracer Technique for Experimentally Obtaining Impingement Characteristics of Arbitrary Bodies and a Method for Determining Droplet Size Distribution

A dye-tracer technique has been developed whereby the quantity of dyed water collected on a blotter-wrapped body exposed to an air stream containing a dyed-water spray cloud can be colorimetrically determined in order to obtain local collection efficiencies, total collection efficiency, and rearward extent of impingement on the body. In addition, a method has been developed whereby the impingement characteristics obtained experimentally for a body can be related to theoretical impingement data for the same body in order to determine the droplet size distribution of the impinging cloud. Several cylinders, a ribbon, and an aspirating device to measure cloud liquid-water content were used in the studies presented herein for the purpose of evaluating the dye-tracer technique. Although the experimental techniques used in the dye-tracer technique require careful control, the methods presented herein should be applicable for any wind tunnel provided the humidity of the air stream can be maintained near saturation.

VonGlahn, Uwe H.↗

Controlled environment life support system: Calcium-related leaf injuries on plants

Calcium related injuries to plants grown in controlled environments under conditions which maximize plant growth rates are described. Procedures to encourage movement of calcium into developing leaves of lettuce plants were investigated. The time course and pattern of calcium accumulation was determined to develop effective control procedures for this injury, termed tipburn. Procedures investigated were: (1) increasing the relative humidity to saturation during the dark period and altering root temperatures, (2) maximizing water stress during light and minimizing water stress during dark periods, (3) shortening the light-dark cycle lengths in combination with elevated moisture levels during the dark cycles, (4) reducing nutrient concentrations and (5) vibrating the plants. Saturated humidities at night increased the rate of growth and the large fluctuation in plant water potential encouraged calcium movement to the young leaves and delayed tipburn. Root temperature regulation between 15 and 26 C was not effective in preventing tipburn. Attempts to modulate water stress produced little variation, but no difference in tipburn development. Variations in light-dark cycle lengths also had no effect on calcium concentrations within developing leaves and no variation in tipburn development. Low concentrations of nutrient solution delayed tipburn, presumably because of greater calcium transport in the low concentration plants. Shaking of the plants did not prevent tipburn, but did delay it slightly.

Tibbitts, T. W.↗

Development of Micro Air Reconnaissance Vehicle as a Test Bed for Advanced Sensors and Electronics

This paper describes the development of a Micro/Mini Air Reconnaissance Vehicle for advanced sensors and electronics at NASA Langley Research Center over the last year. This vehicle is expected to have a total weight of less than four pounds, a design velocity of 40 mph, an endurance of 15-20 minutes, and a maximum range of 5km. The vehicle has wings that are simple to detach yet retain the correct alignment. The upper fuselage surface has a quick release hatch used to access the interior and also to mount the varying propulsion systems. The sensor suite developed for this vehicle consists of a Pitot-static measurement system for determining air speed, an absolute pressure measurement for determining altitude, magnetic direction measurement, and three orthogonal gyros to determine body angular rates. Swarming GPS-guidance and in-flight maneuvering is discussed, as well as design and installation of some other advance sensors like MEMS microphones, infrared cameras, GPS, humidity sensors, and an ultrasonic sonar sensor. Also low cost, small size, high performance control and navigation system for the Micro Air Vehicle is discussed. At the end, laboratory characterization of different sensors, motors, propellers, and batteries will be discussed.

Shams, Qamar A.↗