Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Computationally-efficient stochastic cluster dynamics method for modeling damage accumulation in irradiated materials

An improved version of a recently developed stochastic cluster dynamics (SCD) method (Marian and Bulatov, 2012) [6] is introduced as an alternative to rate theory (RT) methods for solving coupled ordinary differential equation (ODE) systems for irradiation damage simulations. SCD circumvents by design the curse of dimensionality of the variable space that renders traditional ODE-based RT approaches inefficient when handling complex defect population comprised of multiple (more than two) defect species. Several improvements introduced here enable efficient and accurate simulations of irradiated materials up to realistic (high) damage doses characteristic of next-generation nuclear systems. The first improvement is a procedure for efficiently updating the defect reaction-network and event selection in the context of a dynamically expanding reaction-network. Next is a novel implementation of the τ-leaping method that speeds up SCD simulations by advancing the state of the reaction network in large time increments when appropriate. Lastly, a volume rescaling procedure is introduced to control the computational complexity of the expanding reaction-network through occasional reductions of the defect population while maintaining accurate statistics. The enhanced SCD method is then applied to model defect cluster accumulation in iron thin films subjected to triple ion-beam (Fe{sup 3+}, He{sup +} and H{sup +}) irradiations, for which standard RT or spatially-resolved kinetic Monte Carlo simulations are prohibitively expensive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of the radiation doses in newborn patients submitted to CT examinations

The number of computed tomography (CT) scans available to the population is increasing, as well as the complexity of such exams. As a result, the radiation doses are increasing as well. Considering the population exposed to CT exams, pediatric patients are considerably more sensitive to radiation than adults. They have a longer life expectancy than adults, and may receive a higher radiation dose than necessary if the CT scan settings are not adjusted for their smaller body size. As a result of these considerations, the risk of developing cancer is of great concern when newborn patients are involved. The objective of this work was to study the radiation doses on radiosensitive organs of newborn patients undergoing a whole body CT examination, utilizing Monte Carlo simulations. The novelty of this work is the use of pediatric virtual anthropomorphic phantoms, developed at the Department of Nuclear Energy at the Federal University of Pernambuco (DEN/UFPE). The CT equipment utilized during the simulations was a Discovery VCT GE PET/CT system, with a tube voltage of 140 kVp. The X-ray spectrum of this CT scanner was generated by the SRS-78 software, which takes into account the X-ray beam energy used in PET/CT procedures. The absorbed organ doses were computed employing the F6 tally (MeV/g). The results were converted to dose coefficients (mGy/100 mA) for all the structures, considering all employed beams. The highest dose coefficients values were obtained for the brain and the thyroid. This work provides useful information regarding the risks involving ionizing radiation in newborn patients, employing a new and reliable technique. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-G-17A-04: Internal Dosimetric Calculations for Pediatric Nuclear Imaging Applications, Using Monte Carlo Simulations and High-Resolution Pediatric Computational Models

Purpose: Our purpose is to evaluate the administered absorbed dose in pediatric, nuclear imaging studies. Monte Carlo simulations with the incorporation of pediatric computational models can serve as reference for the accurate determination of absorbed dose. The procedure of the calculated dosimetric factors is described, while a dataset of reference doses is created. Methods: Realistic simulations were executed using the GATE toolkit and a series of pediatric computational models, developed by the “IT'IS Foundation”. The series of the phantoms used in our work includes 6 models in the range of 5–14 years old (3 boys and 3 girls). Pre-processing techniques were applied to the images, to incorporate the phantoms in GATE simulations. The resolution of the phantoms was set to 2 mm3. The most important organ densities were simulated according to the GATE “Materials Database”. Several used radiopharmaceuticals in SPECT and PET applications are being tested, following the EANM pediatric dosage protocol. The biodistributions of the several isotopes used as activity maps in the simulations, were derived by the literature. Results: Initial results of absorbed dose per organ (mGy) are presented in a 5 years old girl from the whole body exposure to 99mTc - SestaMIBI, 30 minutes after administration. Heart, kidney, liver, ovary, pancreas and brain are the most critical organs, in which the S-factors are calculated. The statistical uncertainty in the simulation procedure was kept lower than 5%. The Sfactors for each target organ are calculated in Gy/(MBq*sec) with highest dose being absorbed in kidneys and pancreas (9.29*10{sup 10} and 0.15*10{sup 10} respectively). Conclusion: An approach for the accurate dosimetry on pediatric models is presented, creating a reference dosage dataset for several radionuclides in children computational models with the advantages of MC techniques. Our study is ongoing, extending our investigation to other reference models and evaluating the results with clinical estimated doses.

60 APPLIED LIFE SCIENCES↗

Gallbladder Cryoablation: Proof of Concept in a Swine Model for a Percutaneous Alternative to Cholecystectomy

PurposeTo investigate the feasibility of percutaneous gallbladder cryoablation (GBC) under CT guidance in a swine model with histopathologic correlation.Materials and MethodsInstitutional Animal Care and Use Committee approval was obtained for this study protocol. Five pigs underwent GBC. Under CT guidance, 3–4 cryoprobes were positioned percutaneously at the gallbladder margins. Thermocouple probes were placed percutaneously at the gallbladder fundus, neck, free wall, and gallbladder fossa. Two freeze–thaw cycles ranging from 10 to 26 min were performed. The subjects were sacrificed 5 h after cryoablation. The gallbladder and bile ducts were resected, stained, and examined microscopically.ResultsGBC was completed in all subjects. A 10-mm ablation margin was achieved beyond all gallbladder walls. Thermocouple probes reached at least −20 °C. Intra-procedural body temperature decreased to a minimum of 35 °C but recovered after the procedure. Intra- and post-procedural vital signs otherwise remained within physiologic parameters. Non-target ablation occurred in the stomach and colon of the first two subjects. Histology demonstrated complete denudation of the gallbladder epithelium, hemorrhage, and edema within the muscularis layer, and preservation of the microscopic architecture of the common bile duct in all cases.ConclusionPercutaneous gallbladder cryoablation is feasible, with adequate ablation margins obtained and histologic changes demonstrating transmural necrosis. Adjacent structures included in the ablation may require conservative ablation zones, hydrodissection, or continuous saline lavage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flow of fresh concrete through reinforced elements: Experimental validation of the porous analogy numerical method

Numerical simulations of concrete castings are complex and time consuming. In order to decrease simulation time and to simplify simulation procedure, an innovative modelling approach, which treats reinforced sections in a formwork as porous media, was proposed. In the previous studies, this numerical model was proved suitable to simulate casting of model yield-stress fluids through reinforced elements. This article focuses on the experimental validation of the proposed model at the concrete scale. For this purpose, a large-scale laboratory casting of a highly reinforced beam is performed. The casting process is numerically simulated and the numerical results are compared to the experimental measurements.

36 MATERIALS SCIENCE↗

Poster — Thur Eve — 02: Measurement of CT radiation profile width using Fuji CR imaging plate raw data

Measuring the CT collimation width and assessing the shape of the overall profile is a relatively straightforward quality control (QC) measure that impacts both image quality and patient dose, and is often required at acceptance and routine testing. Most CT facilities have access to computed radiography (CR) systems, so performing CT collimation profile assessments using CR plates requires no additional equipment. Previous studies have shown how to effectively use CR plates to measure the radiation profile width. However, a major limitation of the previous work is that the full dynamic range of CR detector plates are not used, since the CR processing technology reduces the dynamic range of the DICOM output to 2{sup 10}, requiring the sensitivity and latitude settings of CR reader to be adjusted to prevent clipping of the CT profile data. Such adjustments to CR readers unnecessarily complicate the QC procedure. These clipping artefacts hinder the ability to accurately assess CT collimation width because the full-width at half maximum value of the penumbras are not properly determined if the maximum dose of the profile is not available. Furthermore, any inconsistencies in the radiation profile shape are lost if the profile plateau is clipped off. In this work we developed an opensource Matlab script for straightforward CT profile width measurements using raw CR data that also allows assessment of the profile shape without clipping, and applied this approach during CT QC.

60 APPLIED LIFE SCIENCES↗

Neutron Diagnostics for Deuteron Flows from Pulsed Plasma Formations in a Magnetic Field

A diagnostic procedure establishing a relation between the energy of a laser pulse W (0.1 ≤ W ≤ 0.8) and the number of deuterons N{sub d} extracted from the laser plasma in a vacuum accelerating diode with magnetic isolation of electrons is presented. The diagnostics is based on the measurement of neutrons generated at a target, which is a part of the ion collector at the same time. The results of experimental research and numerical modeling for the accelerating voltage at a diode interval up to 400 kV are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

STATISTICAL ANALYSIS OF CURRENT SHEETS IN THREE-DIMENSIONAL MAGNETOHYDRODYNAMIC TURBULENCE

We develop a framework for studying the statistical properties of current sheets in numerical simulations of magnetohydrodynamic (MHD) turbulence with a strong guide field, as modeled by reduced MHD. We describe an algorithm that identifies current sheets in a simulation snapshot and then determines their geometrical properties (including length, width, and thickness) and intensities (peak current density and total energy dissipation rate). We then apply this procedure to simulations of reduced MHD and perform a statistical analysis on the obtained population of current sheets. We evaluate the role of reconnection by separately studying the populations of current sheets which contain magnetic X-points and those which do not. We find that the statistical properties of the two populations are different in general. We compare the scaling of these properties to phenomenological predictions obtained for the inertial range of MHD turbulence. Finally, we test whether the reconnecting current sheets are consistent with the Sweet-Parker model.

79 ASTRONOMY AND ASTROPHYSICS↗

Unenhanced Cone Beam Computed Tomography and Fusion Imaging in Direct Percutaneous Sac Injection for Treatment of Type II Endoleak: Technical Note

AimTo evaluate safety, feasibility, technical success, and clinical success of direct percutaneous sac injection (DPSI) for the treatment of type II endoleaks (T2EL) using anatomical landmarks on cone beam computed tomography (CBCT) and fusion imaging (FI).Materials and MethodsEight patients with T2EL were treated with DPSI using CBCT as imaging guidance. Anatomical landmarks on unenhanced CBCT were used for referencing T2EL location in the first five patients, while FI between unenhanced CBCT and pre-procedural computed tomography angiography (CTA) was used in the remaining three patients. Embolization was performed with thrombin, glue, and ethylene–vinyl alcohol copolymer. Technical and clinical success, iodinated contrast utilization, procedural time, fluoroscopy time, and mean radiation dose were registered.ResultsDPSI was technically successful in all patients: the needle was correctly positioned at the first attempt in six patients, while in two of the first five patients the needle was repositioned once. Neither minor nor major complications were registered. Average procedural time was 45 min and the average administered iodinated contrast was 13 ml. Mean radiation dose of the procedure was 60.43 Gy cm{sup 2} and mean fluoroscopy time was 18 min. Clinical success was achieved in all patients (mean follow-up of 36 months): no sign of T2EL was reported in seven patients until last CT follow-up, while it persisted in one patient with stability of sac diameter.ConclusionsDPSI using unenhanced CBCT and FI is feasible and provides the interventional radiologist with an accurate and safe alternative to endovascular treatment with limited iodinated contrast utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of 3-dimensional dose reconstruction system between fluence-based system and dose measurement-guided system

COMPASS system (IBA Dosimetry, Schwarzenbruck, Germany) and ArcCHECK with 3DVH software (Sun Nuclear Corp., Melbourne, FL) are commercial quasi-3-dimensional (3D) dosimetry arrays. Cross-validation to compare them under the same conditions, such as a treatment plan, allows for clear evaluation of such measurement devices. In this study, we evaluated the accuracy of reconstructed dose distributions from the COMPASS system and ArcCHECK with 3DVH software using Monte Carlo simulation (MC) for multi-leaf collimator (MLC) test patterns and clinical VMAT plans. In a phantom study, ArcCHECK 3DVH showed clear differences from COMPASS, measurement and MC due to the detector resolution and the dose reconstruction method. Especially, ArcCHECK 3DVH showed 7% difference from MC for the heterogeneous phantom. ArcCHECK 3DVH only corrects the 3D dose distribution of treatment planning system (TPS) using ArcCHECK measurement, and therefore the accuracy of ArcCHECK 3DVH depends on TPS. In contrast, COMPASS showed good agreement with MC for all cases. However, the COMPASS system requires many complicated installation procedures such as beam modeling, and appropriate commissioning is needed. In terms of clinical cases, there were no large differences for each QA device. The accuracy of the compass and ArcCHECK 3DVH systems for phantoms and clinical cases was compared. Both systems have advantages and disadvantages for clinical use, and consideration of the operating environment is important. The QA system selection is depending on the purpose and workflow in each hospital.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo simulation of initial breakdown phase for magnetised toroidal ICRF discharges

The radio-frequency (RF) plasma production technique in the ion cyclotron range of frequency (ICRF) attracts growing attention among fusion experts because of its high potential for solving several basic problems of reactor-oriented superconducting fusion machines, such as ICRF wall conditioning in tokamaks and stellarators (T{sub e} = 3−5eV, n{sub e}<10{sup 12}cm{sup −3}), ICRF-assisted tokamak start-up and target plasma production (n{sub e} = 10{sup 13}cm{sup −3}) in stellarators. Plasma initiation by ICRF has been studied intensively using single particle descriptions and basic analytic models. To further improve the present understanding on plasma production employing the vacuum RF field of ICRF antennas in toroidal devices in presence of the toroidal magnetic field, and its parametric dependencies a Monte Carlo code has been developed. The 1D code RFdinity1D describes the motion of electrons, accelerated by the RF field in front of the ICRF antenna, along one toroidal magnetic field line. Dependent on their individual energies and the related electron collision cross sections (ionisation, excitation and dissociation) weighted by a Monte Carlo procedure, an electron avalanche may occur. Breakdown conditions are discussed as function of RF discharge parameters (i) RF vacuum electric field strength, (ii) RF frequency and (iii) neutral pressure (H2). The slope of the exponential density increase, taken as measure for the breakdown speed, shows qualitative agreement to experimental breakdown times as found in literature and experimental data of the ASDEX upgrade and TEXTOR tokamak, and is interpreted by studying the characteristic electron velocity distribution functions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of HELIOS for ATR Core Follow Analyses

This work summarizes the validation analyses for the HELIOS code to support core design and safety assurance calculations of the Advanced Test Reactor (ATR). Past and current core safety assurance is performed by the PDQ-7 diffusion code; a state of the art reactor physics simulation tool from the nuclear industry’s earlier days. Over the past twenty years, improvements in computational speed have enabled the use of modern neutron transport methodologies to replace the role of diffusion theory for simulation of complex systems, such as the ATR. More exact methodologies have enabled a paradigm-shift away from highly tuned codes that force compliance with a bounding safety envelope, and towards codes regularly validated against routine measurements. To validate HELIOS, the 16 ATR operational cycles from late-2009 to present were modeled. The computed power distribution was compared against data collected by the ATR’s on-line power surveillance system. It was found that the ATR’s lobe-powers could be determined with ±10% accuracy. Also, the ATR’s cold startup shim configuration for each of these 16 cycles was estimated and compared against the reported critical position from the reactor log-book. HELIOS successfully predicted criticality within the tolerance set by the ATR startup procedure for 13 out of the 16 cycles. This is compared to 12 times for PDQ (without empirical adjustment). These findings, as well as other insights discussed in this report, suggest that HELIOS is highly suited for replacing PDQ for core safety assurance of the ATR. Furthermore, a modern verification and validation framework has been established that allows reactor and fuel performance data to be computed with a known degree of accuracy and stated uncertainty.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement Concept for a Possible Clearance of Mercury Waste from Nuclear Facilities - 19138

This paper describes the development of a measurement concept for a clearance of mercury waste from the decommissioning of nuclear facilities. A decontamination of mercury is performed after which large parts of the waste could possibly be released into reuse or conventional mercury disposal. The focus of this work is on the development and validation of a gamma-spectrometric measurement setup that is used for decision-making measurements for a possible clearance procedure. The measurement system is validated by a comparison of experimental measurements with nuclear simulations using Monte Carlo N-Particle{sup R} Transport Code (MCNP{sup R}). The validated MCNP{sup R} simulation model is used to determine the energy-dependent photopeak efficiencies and subsequently the sensitivity of the measurements. Preliminary results of gamma spectrometry in combination with MCNP{sup R} simulations indicate that a clearance of elemental mercury should be possible after decontamination. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of Material Constitutive Laws for Inconel 718 Superalloy Under Different Strain Rates and Working Temperatures

In this paper, a special procedure for the prediction of parameters of the Johnson–Cook constitutive material models is proposed based on the experimental data and specially developed MATLAB scripts which allow advanced modeling of complex 3D response surfaces. Experimental investigations concern two various strain rates of 10{sup −3} and 10{sup 1} 1/s and the testing temperature ranging from the ambient up to 700 °C. As a result, a set of mathematical equations which fit the experimental data is determined. The applicability of the experimentally derived constitutive models to the FEM modeling of real machining processes of Inconel 718 alloy is verified.

36 MATERIALS SCIENCE↗

Minimizing Error Potential Using Computer Applications - 18498

Many Savannah River Site (SRS) liquid waste facility operations depend upon repetitive engineering calculations and operator actions. Although these calculations and actions are formalized in technical reports and paper procedures, they can still be vulnerable to data entry errors, calculation errors, equipment alignment errors, and occasional changes caused by different people performing these activities. Savannah River Remediation (SRR) is using computer automation to reduce these error precursors by standardizing repetitive calculations and by performing plant alignment checks for repetitive operation processes. Data entry can be automated, calculation methodologies can be standardized, and computers can check to see that predefined plant conditions exist before equipment operation. In addition to improving quality, the time required for these activities to generate technical reports, to perform independent reviews, and to perform equipment alignment checks can be significantly reduced. In the case of operator-performed calculations, error precursors involve distractions that can occur over a multi-page paper procedure, confusing displays and controls from equipment, mathematical errors, complacency, and unfamiliarity with the procedure among many others. Repetitive engineering calculations suffer from similar error precursors and are often compounded by high workloads, lack of proficiency, lack of standard methodology, mental shortcuts, and biases. Web-based computer applications can eliminate many of these precursors through standardization. Calculation methods are fixed, inputs are fixed, and computer checks can highlight potentially wrong inputs and outputs. Automated calculations are performed almost instantaneously once input is provided. Operators and engineers can spend more time focusing on the results than on the process to achieve the results. Similarly, when operators use repetitive procedures involving equipment manipulation, the same error precursors apply. Automated operation sequences and equipment checks can be programmed into the distributed control system to provide standard operating processes that reduce and eliminate error precursors. This paper describes how SRR incorporates Human Performance Improvement (HPI) principles when automating calculations and operation processes. Computer applications will be reviewed in detail, highlighting the software development life-cycle that includes requirements gathering, prototyping, design, development, testing, and implementation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Response function of single crystal synthetic diamond detectors to 1-4 MeV neutrons for spectroscopy of D plasmas

A Single-crystal Diamond (SD) detector prototype was installed at Joint European Torus (JET) in 2013 and the achieved results have shown its spectroscopic capability of measuring 2.5 MeV neutrons from deuterium plasmas. This paper presents measurements of the SD response function to monoenergetic neutrons, which is a key point for the development of a neutron spectrometer based on SDs and compares them with Monte Carlo simulations. The analysis procedure allows for a good reconstruction of the experimental results. The good pulse height energy resolution (equivalent FWHM of 80 keV at 2.5 MeV), gain stability, insensitivity to magnetic field, and compact size make SDs attractive as compact neutron spectrometers of high flux deuterium plasmas, such as for instance those needed for the ITER neutron camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mock Quasar-Lyman-α forest data-sets for the SDSS-III Baryon Oscillation Spectroscopic Survey

We describe mock data-sets generated to simulate the high-redshift quasar sample in Data Release 11 (DR11) of the SDSS-III Baryon Oscillation Spectroscopic Survey (BOSS). The mock spectra contain Lyα forest correlations useful for studying the 3D correlation function including Baryon Acoustic Oscillations (BAO). They also include astrophysical effects such as quasar continuum diversity and high-density absorbers, instrumental effects such as noise and spectral resolution, as well as imperfections introduced by the SDSS pipeline treatment of the raw data. The Lyα forest BAO analysis of the BOSS collaboration, described in Delubac et al. 2014, has used these mock data-sets to develop and cross-check analysis procedures prior to performing the BAO analysis on real data, and for continued systematic cross checks. Tests presented here show that the simulations reproduce sufficiently well important characteristics of real spectra. These mock data-sets will be made available together with the data at the time of the Data Release 11.

79 ASTRONOMY AND ASTROPHYSICS↗

A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)

Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS scans and demonstrated a significant reduction in measurement variation associated with the test object. Conclusions: Three operator errors were identified which significantly affected the usability of the acquired scan images of the test object used for monitoring scanner stability in a multicenter study. The authors’ results demonstrated that at the time of test object scan receipt at a radiology core laboratory, quality control procedures should include an assessment of tilt index, water bottle offset, and air bubble size within the water bottle. Application of this methodology to 2272 SPIROMICS scans indicated that their findings were not limited to the scanner make and model used for the initial test but was generalizable to both Siemens and GE scanners which comprise the scanner types used within the SPIROMICS study.

60 APPLIED LIFE SCIENCES↗