Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Computed Tomography–Planned High-Dose-Rate Brachytherapy for Treating Uterine Cervical Cancer

Purpose: To evaluate the long-term results of computed tomography (CT)–planned high-dose-rate (HDR) brachytherapy (BT) for treating cervical cancer patients. Methods and Materials: CT-planned HDR BT was performed according to the adapted Group European de Curietherapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) recommendations in 216 consecutive patients with locally advanced cervical cancer, International Federation of Gynecology and Obstetrics (FIGO) stage IB to IVA, who were treated with conformal external beam radiation therapy and concomitant chemotherapy. We analyzed outcomes and late side effects evaluated according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer and Subjective, Objective, Management, Analysis evaluation scoring system and compared them with the results from a historical group. Results: The median age was 56 years (range, 32-83 years). The median follow-up time for living patients was 52 months (range 37-63 months). The 5-year cumulative incidence function for the local recurrence rate for patients with FIGO II and III was 5.5% and 20%, respectively (P=.001). The 5-year rates of overall survival (OS) and disease-free survival (DFS) were 66.4% and 58.5%, respectively. The relative risk of failure for OS and DFS for FIGO III in relation to FIGO II was 2.24 (P=.003) and 2.6 (P=.000) and for lymph node enlargement was 2.3 (P=.002) and 2 (P=.006), respectively. In 2 patients, rectovaginal fistula occurred, and in 1 patient, vesicovaginal fistula occurred without local progression. Comparison of late adverse effects in patients treated according to the GEC-ESTRO recommendations and in the historical group revealed a reduction in fistula formation of 59% and also a reduction in rectal grade 3 to 4 late toxicity of >59%. Conclusions: This is the largest report with mature data of CT-planned BT HDR for the treatment of cervical cancer with good local control and acceptable toxicity. In comparison with the historical series, there is a substantial benefit in terms of severe late effects. FIGO III and enlarged lymph nodes in positron emission tomography–CT/CT are negative prognostic factors, both with a relative risk of failure of approximately 2.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a lab-scale, high-resolution, tube-generated X-ray computed-tomography system for three-dimensional (3D) materials characterization

The design and construction of a modular high resolution X-ray computed tomography (XCT) system is highlighted in this paper. The design approach is detailed for meeting a specified set of instrument performance goals tailored towards experimental versatility and high resolution imaging. The XCT tool is unique in the detector and X-ray source design configuration, enabling control in the balance between detection efficiency and spatial resolution. The system package is also unique: The sample manipulation approach implemented enables a wide gamut of in situ experimentation to analyze structure evolution under applied stimulus, by optimizing scan conditions through a high degree of controllability. The component selection and design process is detailed: Incorporated components are specified, custom designs are shared, and the approach for their integration into a fully functional XCT scanner is provided. Custom designs discussed include the dual-target X-ray source cradle which maintains position and trajectory of the beam between the two X-ray target configurations with respect to a scintillator mounting and positioning assembly and the imaging sensor, as well as a novel large-format X-ray detector with enhanced adaptability. The instrument is discussed from an operational point of view, including the details of data acquisition and processing implemented for 3D imaging via micro-CT. The performance of the instrument is demonstrated on a silica-glass particle/hydroxyl-terminated-polybutadiene (HTPB) matrix binder PBX simulant. Post-scan data processing, specifically segmentation of the sample's relevant microstructure from the 3D reconstruction, is provided to demonstrate the utility of the instrument. - Highlights: • Custom built X-ray tomography system for microstructural characterization • Detector design for maximizing polychromatic X-ray detection efficiency • X-ray design offered for maximizing X-ray flux with respect to imaging resolution • Novel lab-scale XCT data acquisition and data processing methods • 3D characterization of glass-bead mock plastic-bonded-explosive stimulant.

36 MATERIALS SCIENCE↗

Analysis of Daily Setup Variation With Tomotherapy Megavoltage Computed Tomography

The purpose of this study was to evaluate different setup uncertainties for various anatomic sites with TomoTherapy (registered) pretreatment megavoltage computed tomography (MVCT) and to provide optimal margin guidelines for these anatomic sites. Ninety-two patients with tumors in head and neck (HN), brain, lung, abdominal, or prostate regions were included in the study. MVCT was used to verify patient position and tumor target localization before each treatment. With the anatomy registration tool, MVCT provided real-time tumor shift coordinates relative to the positions where the simulation CT was performed. Thermoplastic facemasks were used for HN and brain treatments. Vac-Lok{sup TM} cushions were used to immobilize the lower extremities up to the thighs for prostate patients. No respiration suppression was administered for lung and abdomen patients. The interfractional setup variations were recorded and corrected before treatment. The mean interfractional setup error was the smallest for HN among the 5 sites analyzed. The average 3D displacement in lateral, longitudinal, and vertical directions for the 5 sites ranged from 2.2-7.7 mm for HN and lung, respectively. The largest movement in the lung was 2.0 cm in the longitudinal direction, with a mean error of 6.0 mm and standard deviation of 4.8 mm. The mean interfractional rotation variation was small and ranged from 0.2-0.5 deg., with the standard deviation ranging from 0.7-0.9 deg. Internal organ displacement was also investigated with a posttreatment MVCT scan for HN, lung, abdomen, and prostate patients. The maximum 3D intrafractional displacement across all sites was less than 4.5 mm. The interfractional systematic errors and random errors were analyzed and the suggested margins for HN, brain, prostate, abdomen, and lung in the lateral, longitudinal, and vertical directions were between 4.2 and 8.2 mm, 5.0 mm and 12.0 mm, and 1.5 mm and 6.8 mm, respectively. We suggest that TomoTherapy (registered) pretreatment MVCT can be used to improve the accuracy of patient positioning and reduce tumor margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed tomography image using sub-terahertz waves generated from a high-T{sub c} superconducting intrinsic Josephson junction oscillator

A computed tomography (CT) imaging system using monochromatic sub-terahertz coherent electromagnetic waves generated from a device constructed from the intrinsic Josephson junctions in a single crystalline mesa structure of the high-T{sub c} superconductor Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+δ} was developed and tested on three samples: Standing metallic rods supported by styrofoam, a dried plant (heart pea) containing seeds, and a plastic doll inside an egg shell. The images obtained strongly suggest that this CT imaging system may be useful for a variety of practical applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improving accuracy of electron density measurement in the presence of metallic implants using orthovoltage computed tomography

The goal of this study was to evaluate the improvement in electron density measurement and metal artifact reduction using orthovoltage computed tomography (OVCT) imaging compared with conventional kilovoltage CT (KVCT). For this study, a bench-top system was constructed with adjustable x-ray tube voltage up to 320 kVp. A commercial tissue-characterization phantom loaded with inserts of various human tissue substitutes was imaged using 125 kVp (KVCT) and 320 kVp (OVCT) x rays. Stoichiometric calibration was performed for both KVCT and OVCT imaging using the Schneider method. The metal inserts--titanium rods and aluminum rods--were used to study the impact of metal artifacts on the electron-density measurements both inside and outside the metal inserts. It was found that the relationships between Hounsfield units and relative electron densities (to water) were more predictable for OVCT than KVCT. Unlike KVCT, the stoichiometric calibration for OVCT was insensitive to the use of tissue substitutes for direct electron density calibration. OVCT was found to significantly reduce metal streak artifacts. Errors in electron-density measurements within uniform tissue substitutes were reduced from 42% (maximum) and 18% (root-mean-square) in KVCT to 12% and 2% in OVCT, respectively. Improvements were also observed inside the metal implants. For the detectors optimized for KVCT, the imaging dose is almost doubled for OVCT for the image quality comparable to KVCT. OVCT may be a good option for high-precision radiotherapy treatment planning, especially for patients with metal implants and especially for charged particle therapy, such as proton therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality and accuracy of cone beam computed tomography gated by active breathing control

The purpose of this study was to evaluate the quality and accuracy of cone beam computed tomography (CBCT) gated by active breathing control (ABC), which may be useful for image guidance in the presence of respiration. Comparisons were made between conventional ABC-CBCT (stop and go), fast ABC-CBCT (a method to speed up the acquisition by slowing the gantry instead of stopping during free breathing), and free breathing respiration correlated CBCT. Image quality was assessed in phantom. Accuracy of reconstructed voxel intensity, uniformity, and root mean square error were evaluated. Registration accuracy (bony and soft tissue) was quantified with both an anthropomorphic and a quality assurance phantom. Gantry angle accuracy was measured with respect to gantry speed modulation. Conventional ABC-CBCT scan time ranged from 2.3 to 5.8 min. Fast ABC-CBCT scan time ranged from 1.4 to 1.8 min, and respiratory correlated CBCT scans took 2.1 min to complete. Voxel intensity value for ABC gated scans was accurate relative to a normal clinical scan with all projections. Uniformity and root mean square error performance degraded as the number of projections used in the reconstruction of the fast ABC-CBCT scans decreased (shortest breath hold, longest free breathing segment). Registration accuracy for small, large, and rotational corrections was within 1 mm and 1 degree sign . Gantry angle accuracy was within 1 degree sign for all scans. For high-contrast targets, performance for image-guidance purposes was similar for fast and conventional ABC-CBCT scans and respiration correlated CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping

Purpose: The purpose of this work is to demonstrate that multicontrast computed tomography (CT) imaging can be performed using a Talbot-Lau interferometer without phase stepping, thus allowing for an acquisition scheme like that used for standard absorption CT. Methods: Rather than using phase stepping to extract refraction, small-angle scattering (SAS), and absorption signals, the two gratings of a Talbot-Lau interferometer were rotated slightly to generate a moire pattern on the detector. A Fourier analysis of the moire pattern was performed to obtain separate projection images of each of the three contrast signals, all from the same single-shot of x-ray exposure. After the signals were extracted from the detector data for all view angles, image reconstruction was performed to obtain absorption, refraction, and SAS CT images. A physical phantom was scanned to validate the proposed data acquisition method. The results were compared with a phantom scan using the standard phase stepping approach. Results: The reconstruction of each contrast mechanism produced the expected results. Signal levels and contrasts match those obtained using the phase stepping technique. Conclusions: Absorption, refraction, and SAS CT imaging can be achieved using the Talbot-Lau interferometer without the additional overhead of long scan time and phase stepping.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-05: A Correction Algorithm for Kilovoltage Cone-Beam Computed Tomography Dose Calculations in Cervical Cancer Patients

Purpose: To investigate the accuracy and feasibility of dose calculations using kilovoltage cone beam computed tomography in cervical cancer radiotherapy using a correction algorithm. Methods: The Hounsfield units (HU) and electron density (HU-density) curve was obtained for both planning CT (pCT) and kilovoltage cone beam CT (CBCT) using a CIRS-062 calibration phantom. The pCT and kV-CBCT images have different HU values, and if the HU-density curve of CBCT was directly used to calculate dose in CBCT images may have a deviation on dose distribution. It is necessary to normalize the different HU values between pCT and CBCT. A HU correction algorithm was used for CBCT images (cCBCT). Fifteen intensity-modulated radiation therapy (IMRT) plans of cervical cancer were chosen, and the plans were transferred to the pCT and cCBCT data sets without any changes for dose calculations. Phantom and patient studies were carried out. The dose differences and dose distributions were compared between cCBCT plan and pCT plan. Results: The HU number of CBCT was measured by several times, and the maximum change was less than 2%. To compare with pCT, the CBCT and cCBCT has a discrepancy, the dose differences in CBCT and cCBCT images were 2.48%±0.65% (range: 1.3%∼3.8%) and 0.48%±0.21% (range: 0.1%∼0.82%) for phantom study, respectively. For dose calculation in patient images, the dose differences were 2.25%±0.43% (range: 1.4%∼3.4%) and 0.63%±0.35% (range: 0.13%∼0.97%), respectively. And for the dose distributions, the passing rate of cCBCT was higher than the CBCTs. Conclusion: The CBCT image for dose calculation is feasible in cervical cancer radiotherapy, and the correction algorithm offers acceptable accuracy. It will become a useful tool for adaptive radiation therapy.

60 APPLIED LIFE SCIENCES↗

Evaluation of a deformable registration algorithm for subsequent lung computed tomography imaging during radiochemotherapy

Purpose: Rating both a lung segmentation algorithm and a deformable image registration (DIR) algorithm for subsequent lung computed tomography (CT) images by different evaluation techniques. Furthermore, investigating the relative performance and the correlation of the different evaluation techniques to address their potential value in a clinical setting. Methods: Two to seven subsequent CT images (69 in total) of 15 lung cancer patients were acquired prior, during, and after radiochemotherapy. Automated lung segmentations were compared to manually adapted contours. DIR between the first and all following CT images was performed with a fast algorithm specialized for lung tissue registration, requiring the lung segmentation as input. DIR results were evaluated based on landmark distances, lung contour metrics, and vector field inconsistencies in different subvolumes defined by eroding the lung contour. Correlations between the results from the three methods were evaluated. Results: Automated lung contour segmentation was satisfactory in 18 cases (26%), failed in 6 cases (9%), and required manual correction in 45 cases (66%). Initial and corrected contours had large overlap but showed strong local deviations. Landmark-based DIR evaluation revealed high accuracy compared to CT resolution with an average error of 2.9 mm. Contour metrics of deformed contours were largely satisfactory. The median vector length of inconsistency vector fields was 0.9 mm in the lung volume and slightly smaller for the eroded volumes. There was no clear correlation between the three evaluation approaches. Conclusions: Automatic lung segmentation remains challenging but can assist the manual delineation process. Proven by three techniques, the inspected DIR algorithm delivers reliable results for the lung CT data sets acquired at different time points. Clinical application of DIR demands a fast DIR evaluation to identify unacceptable results, for instance, by combining different automated DIR evaluation methods.

60 APPLIED LIFE SCIENCES↗

Ultrasonic Testing (UT) and Computed Tomography (CT) Comparative Scanning of Proposed Additive Manufacturing Reference Standard

This report presents qualitative results of ultrasonic full matrix capture/total focusing method (FMC/TFM) scanning of two series of blocks, additively manufactured by powder bed fusion, containing a variety of internal features and structures that would not be achievable by conventional manufacturing techniques. The purpose of the first series of additively manufactured (AM) blocks was to explore the possibility of building calibration blocks for FMC/TFM ultrasonic testing (UT). It was confirmed that AM is a suitable candidate for generation of unusual and novel reflector forms, such as rotating slots, purposely embedded voids, and tapering holes, and that FMC/TFM was very capable of characterizing them. The intended use of the second series of AM blocks was as UT reference blocks to characterize the AM process quality or the interrogating UT technique. The larger block in this series was scanned from multiple faces, using multiple UT methods (conventional UT and FMC/TFM) and X-ray computed tomography for comparative purposes. The performance of each method was quantified by a metric corresponding to the detection limit of each feature, and the quantitative results are discussed.

36 MATERIALS SCIENCE↗

Investigation of the Feasibility of Utilizing Gamma Emission Computed Tomography in Evaluating Fission Product Migration in Irradiated TRISO Fuel Experiments

In the High Temperature Gas-Cooled Reactor (HTGR) the TRISO particle fuel serves as the primary fission product containment. However the large number of TRISO particles present in proposed HTGRs dictates that there will be a small fraction (~10 -4 to 10 -5 ) of as manufactured and in-pile particle failures that will lead to some fission product release. The matrix material surrounding the TRISO particles in fuel compacts and the structural graphite holding the TRISO particles in place can also serve as sinks for containing any released fission products. However data on the migration of solid fission products through these materials is lacking. One of the primary goals of the AGR-3/4 experiment is to study fission product migration from failed TRISO particles in prototypic HTGR components such as structural graphite and compact matrix material. In this work, the potential for a Gamma Emission Computed Tomography (GECT) technique to non-destructively examine the fission product distribution in AGR-3/4 components and other irradiation experiments is explored. Specifically, the feasibility of using the Idaho National Laboratory (INL) Hot Fuels Examination Facility (HFEF) Precision Gamma Scanner (PGS) system for this GECT application is considered. To test the feasibility, the response of the PGS system to idealized fission product distributions has been simulated using Monte Carlo radiation transport simulations. Previous work that applied similar techniques during the AGR-1 experiment will also be discussed as well as planned uses for the GECT technique during the post irradiation examination of the AGR-2 experiment. The GECT technique has also been applied to other irradiated nuclear fuel systems that were currently available in the HFEF hot cell including oxide fuel pins, metallic fuel pins, and monolithic plate fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The role of contrast-enhanced computed tomography to detect renal stones

Purpose: To investigate the detectability of renal stones in corticomedullary and nephrographic phases on contrast-enhanced computed tomography (CT). Methods: All consecutive patients between January 2012 and February 2016 undergoing CT of the kidneys according to our department’s standard four-phase protocol and having at least one stone in the NC-phase (NCP) were included. Fifty patients with altogether 136 stones were eligible. Two radiologists in consensus evaluated the NCP from each examination and documented the number, location, and size of stones. Three abdominal radiologists blinded to the findings of the NCP reviewed independently the corticomedullary and nephrographic phases on two different occasions. They reported the number and location of stones in each kidney. For the inter-observer agreement the intra-class correlation coefficient (ICC) was estimated. The detection rate of renal stones was calculated for the three radiologists and compared between the two contrast-enhanced phases and the results were analyzed with concern to the size of the stones. Results: The ICC was 0.86. There was no statistically significant difference between corticomedullary and nephrographic phases (p = 0.94). The detection rate for stones measuring 3–5 mm was 82–88% and 98% for stones ≥ 6 mm. Conclusion: The detectability of renal stones ≥ 6 mm on contrast-enhanced CT is extremely high. This means that stones with a higher risk of not passing spontaneously can be safely diagnosed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Indication for Computed Tomography During Hepatic Arteriography (CTHA) in Addition to Dynamic CT Studies to Identify Hypervascularity of Hepatocellular Carcinoma

PurposeTo identify factors benefiting from computed tomography during hepatic arteriography (CTHA) in addition to dynamic CT studies at the preoperative evaluation of the hypervascularity of hepatocellular carcinoma (HCC).Materials and MethodsWe retrospectively divided 45 patients with HCC, who underwent both dynamic CT (dCT) and CTHA, into two groups based on the number of hypervascular HCCs identified on dCT and CTHA studies. In group A, the number of HCCs identified by dCT and CTHA was the same and additive CTHA had not been indicated. In group B, fewer HCCs were counted on dCT than on CTHA images, indicating that additive CTHA studies had been appropriate. We compared the patient characteristics, the serum alpha-fetoprotein level, and the tumor-liver contrast (TLC) of the main tumor on dCT scans of both groups. To identify factors alerting to the benefit of additional CTHA studies, we performed univariate logistic regression analysis. Statistically significant parameters were subjected to receiver operating characteristic analysis for obtaining the optimal cutoff value indicative of the benefit of CTHA.ResultsUnivariate analysis identified only the TLC of the main tumor on dCT images as a significant factor for the benefit of CTHA images (P < 0.01). At the optimal cutoff value for the TLC of the main tumor on dCT images (15.9 Hounsfield units), the sensitivity and specificity for the benefit of CTHA were 85.0 and 92.0%, respectively.ConclusionEvaluation of the TLC of the main tumor on dCT scans identifies patients in whom additive CTHA studies are beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Four-Dimensional Computed Tomography Pulmonary Ventilation Imaging-Based Functional Avoidance for Lung Cancer Radiotherapy

Purpose: To quantify the dosimetric impact of four-dimensional computed tomography (4D-CT) pulmonary ventilation imaging-based functional treatment planning that avoids high-functional lung regions. Methods and Materials: 4D-CT ventilation images were created from 15 non-small-cell lung cancer patients using deformable image registration and quantitative analysis of the resultant displacement vector field. For each patient, anatomic and functional plans were created for intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Consistent beam angles and dose-volume constraints were used for all cases. The plans with Radiation Therapy Oncology Group (RTOG) 0617-defined major deviations were modified until clinically acceptable. Functional planning spared the high-functional lung, and anatomic planning treated the lungs as uniformly functional. We quantified the impact of functional planning compared with anatomic planning using the two- or one-tailed t test. Results: Functional planning led to significant reductions in the high-functional lung dose, without significantly increasing other critical organ doses, but at the expense of significantly degraded the planning target volume (PTV) conformity and homogeneity. The average reduction in the high-functional lung mean dose was 1.8 Gy for IMRT (p < .001) and 2.0 Gy for VMAT (p < .001). Significantly larger changes occurred in the metrics for patients with a larger amount of high-functional lung adjacent to the PTV. Conclusion: The results of the present study have demonstrated the impact of 4D-CT ventilation imaging-based functional planning for IMRT and VMAT for the first time. Our findings indicate the potential of functional planning in lung functional avoidance for both IMRT and VMAT, particularly for patients who have high-functional lung adjacent to the PTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frequency and Clinical Significance of Previously Undetected Incidental Findings Detected on Computed Tomography Simulation Scans for Breast Cancer Patients

Purpose: To determine the frequency and clinical significance of previously undetected incidental findings found on computed tomography (CT) simulation images for breast cancer patients. Methods and Materials: All CT simulation images were first interpreted prospectively by radiation oncologists and then double-checked by diagnostic radiologists. The official reports of CT simulation images for 881 consecutive postoperative breast cancer patients from 2009 to 2010 were retrospectively reviewed. Potentially important incidental findings (PIIFs) were defined as any previously undetected benign or malignancy-related findings requiring further medical follow-up or investigation. For all patients in whom a PIIF was detected, we reviewed the clinical records to determine the clinical significance of the PIIF. If the findings from the additional studies prompted by a PIIF required a change in management, the PIIF was also recorded as a clinically important incidental finding (CIIF). Results: There were a total of 57 (6%) PIIFs. The 57 patients in whom a PIIF was detected were followed for a median of 17 months (range, 3-26). Six cases of CIIFs (0.7% of total) were detected. Of the six CIIFs, three (50%) cases had not been noted by the radiation oncologist until the diagnostic radiologist detected the finding. On multivariate analysis, previous CT examination was an independent predictor for PIIF (p = 0.04). Patients who had not previously received chest CT examinations within 1 year had a statistically significantly higher risk of PIIF than those who had received CT examinations within 6 months (odds ratio, 3.54; 95% confidence interval, 1.32-9.50; p = 0.01). Conclusions: The rate of incidental findings prompting a change in management was low. However, radiation oncologists appear to have some difficulty in detecting incidental findings that require a change in management. Considering cost, it may be reasonable that routine interpretations are given to those who have not received previous chest CT examinations within 1 year.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Position Variation of Pancreatic Tumors Quantified Using Intratumoral Fiducial Markers and Daily Cone Beam Computed Tomography

Purpose: The aim of this study was to quantify interfractional pancreatic position variation using fiducial markers visible on daily cone beam computed tomography (CBCT) scans. In addition, we analyzed possible migration of the markers to investigate their suitability for tumor localization. Methods and Materials: For 13 pancreatic cancer patients with implanted Visicoil markers, CBCT scans were obtained before 17 to 25 fractions (300 CBCTs in total). Image registration with the reference CT was used to determine the displacement of the 2 to 3 markers relative to bony anatomy and to each other. We analyzed the distance between marker pairs as a function of time to identify marker registration error (SD of linear fit residuals) and possible marker migration. For each patient, we determined the mean displacement of markers relative to the reference CT (systematic position error) and the spread in displacements (random position error). From this, we calculated the group systematic error, Σ, and group random error, σ. Results: Marker pair distances showed slight trends with time (range, −0.14 to 0.14 mm/day), possibly due to tissue deformation, but no shifts that would indicate marker migration. The mean SD of the fit residuals was 0.8 mm. We found large interfractional position variations, with for 116 of 300 (39%) fractions a 3-dimensional vector displacement of >10 mm. The spread in displacement varied significantly (P<.01) between patients, from a vector range of 9.1 mm to one of 24.6 mm. For the patient group, Σ was 3.8, 6.6, and 3.5 mm; and σ was 3.6, 4.7 and 2.5 mm, in left–right, superior–inferior, and anterior–posterior directions, respectively. Conclusions: We found large systematic displacements of the fiducial markers relative to bony anatomy, in addition to wide distributions of displacement. These results for interfractional position variation confirm the potential benefit of using fiducial markers rather than bony anatomy for daily online position verification for pancreatic cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Locoregional Control of Non-Small Cell Lung Cancer in Relation to Automated Early Assessment of Tumor Regression on Cone Beam Computed Tomography

Purpose: Large interindividual variations in volume regression of non-small cell lung cancer (NSCLC) are observable on standard cone beam computed tomography (CBCT) during fractionated radiation therapy. Here, a method for automated assessment of tumor volume regression is presented and its potential use in response adapted personalized radiation therapy is evaluated empirically. Methods and Materials: Automated deformable registration with calculation of the Jacobian determinant was applied to serial CBCT scans in a series of 99 patients with NSCLC. Tumor volume at the end of treatment was estimated on the basis of the first one third and two thirds of the scans. The concordance between estimated and actual relative volume at the end of radiation therapy was quantified by Pearson's correlation coefficient. On the basis of the estimated relative volume, the patients were stratified into 2 groups having volume regressions below or above the population median value. Kaplan-Meier plots of locoregional disease-free rate and overall survival in the 2 groups were used to evaluate the predictive value of tumor regression during treatment. Cox proportional hazards model was used to adjust for other clinical characteristics. Results: Automatic measurement of the tumor regression from standard CBCT images was feasible. Pearson's correlation coefficient between manual and automatic measurement was 0.86 in a sample of 9 patients. Most patients experienced tumor volume regression, and this could be quantified early into the treatment course. Interestingly, patients with pronounced volume regression had worse locoregional tumor control and overall survival. This was significant on patient with non-adenocarcinoma histology. Conclusions: Evaluation of routinely acquired CBCT images during radiation therapy provides biological information on the specific tumor. This could potentially form the basis for personalized response adaptive therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-OPERA: A Multicenter/Multivendor Validation of Magnetic Resonance Imaging–Only Prostate Treatment Planning Using Synthetic Computed Tomography Images

Purpose: To validate the dosimetric accuracy and clinical robustness of a commercially available software for magnetic resonance (MR) to synthetic computed tomography (sCT) conversion, in an MR imaging–only workflow for 170 prostate cancer patients. Methods and Materials: The 4 participating centers had MriPlanner (Spectronic Medical), an atlas-based sCT generation software, installed as a cloud-based service. A T2-weighted MR sequence, covering the body contour, was added to the clinical protocol. The MR images were sent from the MR scanner workstation to the MriPlanner platform. The sCT was automatically returned to the treatment planning system. Four MR scanners and 2 magnetic field strengths were included in the study. For each patient, a CT-treatment plan was created and approved according to clinical practice. The sCT was rigidly registered to the CT, and the clinical treatment plan was recalculated on the sCT. The dose distributions from the CT plan and the sCT plan were compared according to a set of dose-volume histogram parameters and gamma evaluation. Treatment techniques included volumetric modulated arc therapy, intensity modulated radiation therapy, and conventional treatment using 2 treatment planning systems and different dose calculation algorithms. Results: The overall (multicenter/multivendor) mean dose differences between sCT and CT dose distributions were below 0.3% for all evaluated organs and targets. Gamma evaluation showed a mean pass rate of 99.12% (0.63%, 1 SD) in the complete body volume and 99.97% (0.13%, 1 SD) in the planning target volume using a 2%/2-mm global gamma criteria. Conclusions: Results of the study show that the sCT conversion method can be used clinically, with minimal differences between sCT and CT dose distributions for target and relevant organs at risk. The small differences seen are consistent between centers, indicating that an MR imaging–only workflow using MriPlanner is robust for a variety of field strengths, vendors, and treatment techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗