Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compressors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Performance Evaluation of Various Configurations for Domestic Refrigerators with R600a

The increasing global focus on mitigating global warming has driven a change in refrigerant selection for domestic refrigerators. While most existing refrigerators use R-134a as their working fluid, there is a gradual shift towards R600a in newly manufactured products to minimize environmental impact. In order to design a more energy-efficient isobutane refrigerator, various configurations, including both single-evaporator and dual-evaporator cycles, were investigated. The study was conducted using a high-fidelity simulation platform, the Heat Pump Design Model (HPDM), developed and experimentally validated by the US DOE/ORNL. This platform includes detailed segment-to-segment heat exchanger model, fan model, and compressor model, utilizing refrigerant properties from REFPROP 10. A quasi-steady-state approach was employed to simulate the transient behavior and performance of a domestic refrigerator. The performance of various configurations was compared, and the effects of the refrigerant properties and operating conditions were also analyzed and discussed.

Yang, Cheng-Min↗

PIP-II Linac Cryogenic Distribution System Design Challenges

The PIP-II linac Cryogenic Distribution System (CDS) is characterized by extremely small heat inflows and robust mechanical design. It consists of a Distribution Valve Box (DVB), Intermediate Transfer Line, Tunnel Transfer Line, comprising 25 Bayonet Cans, and ends with a Turnaround Can. Multiple helium streams, each characterized by distinct helium parameters, flow through each of these elements. The CDS geometry allows maintaining an acceptable pressure drop for each helium stream, considering the planned flows and helium parameters in different operation modes. This is particularly crucial for the return line of helium vapors, which return from cryomodules to the cold compressors and thus have very restrictive pressure drop requirements. On both sides of the DVB there are fixed supports for process pipes. One of the DVB design challenges was to route the process pipes in such a way that their shape provided sufficient compensation for thermal shrinkage. This ensures th at the forces resulting from thermal shrinkage acting on the cryogenic valves remain at a level acceptable to the manufacturer. The required thermal budget of the CDS was achieved by thermo-mechanical optimization of its components, like process pipes fixed supports in Bayonet Cans.

43 PARTICLE ACCELERATORS↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

System Modeling of Frost/Defrost Cycles in Heat Pumps

Accurately modeling frost/defrost cycles is crucial for guiding heat exchanger design, appropriately sizing the compressor, and quantifying seasonal energy consumption for heating. While previous modelling studies of frosting cycle have predominantly focused on the component level of fin-and-tube coils, there has been limited development of models for system defrosting cycles. This study enhances the existing knowledge by improving a detailed, segment-to-segment heat exchanger model to simulate frost/defrost cycles for both fin-and-tube coils and microchannel heat exchangers. Furthermore, it integrates this component-level model into a steady-state/quasi-steady-state system modeling framework to simulate complete frost/defrost processes, i.e. the ORNL Heat Pump Design Model (HPDM). This comprehensive approach will unveil differences in coil types, and their interactions with the outdoor fan. It will also predict energy consumption patterns and time intervals associated with these processes.

Shen, Bo↗

A Simulation Study of 120V Heat Pump Water Heaters

A 120 V heat pump water heater (HPWH) is a direct plug-in option to replace gas water heater (WH) without needing expensive electric panel upgrade to 220 V. To enable the smooth transition, the HPWH should provide comparable water heating capacity as the gas WH. WH capacities are rated in the form of first hour rating (FHR). Typical home gas WHs have FHRs > 65 gallon with a 40-gallon water tank. It imposes a major challenge on 120V HPWHs. Most 120V circuits in US can provide 1,800 to 2,400W, not adequate to drive electric resistance heat to boost FHRs. Thus, all the heat needs to come from the heat pump with its top power below 1500 Watts, which is constraint by the installation footprint. This study uses a hardware based, HPWH design model, i.e. the DOE/ORNL Heat Pump Design Model to design a 120V unit with a brazed plate condenser, fin-and-tube evaporator and an adequately sized compressor. To maximize the FHR, multiple strategies were simulated, including use of a mixing valve, overheating the tank temperature to 140F, a new sensing method for quicker response, and an innovative water circulation path. We also simulated 24-hour unform energy factors (UEF) to show the tradeoff between the capacity and operation efficiency. Additionally, we evaluated the impact of insulation thickness on FHR and UEF, to seek further footprint reduction or stretch the tank volume.

Shen, Bo↗

Residential Integrated Heat Pump to Meet All the Home Comfort Needs

This paper will introduce development and field trial of a residential air-source integrated heat pump for cold climates. The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating. The integrated heat pump is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency > 30.0 EER and required only 25 minutes to heat a 50-gallon tank of water. One heat pump prototype is going through a field trial since April, 2023 in Syracuse, New York. The one-year field test results are summarized.

Shen, Bo↗

“Max-tech FHR”: What is the maximum technically achievable water delivery capacity from a single 120 V plug?

Electrifying water heating will require affordable, direct drop-in replacements for existing gas water heaters that meet consumer expectations for hot water delivery. For many replacement scenarios, affordability requires a replacement option with like-for-like physical product dimensions, and existing consumer expectations presume a large delivery capacity from a small water heater. This work explores the technical potential for hot water delivery capacity for a heat pump water heater (HPWH) powered from a common 120 V plug. Delivery capability in this work is quantified by two metrics: the First Hour Rating (FHR) defined in the Code of Federal Regulations, and a real-world draw profile that resulted in hot water runout during field studies of 120 V HPWHs. The work focuses on the common “tall-and-slim” gas water heater product category, with external product dimensions of 20 inch diameter and 60 inch height. Using a simulation model in DOE/ORNL Heat Pump Design Model, validated by experimental baseline testing of a commercially available 120 V HPWH model, several measures were evaluated to maximize the delivery capacity of a 120 V HPWH. The 120 V HPWH was constrained by 1) external product dimensions of 20 in diameter and 60 inch height, 2) electrical power of 1.5 kW (85% of the available power from a dedicated 120 V, 15 A circuit), and 3) commercially-available components. The measures implemented included a large compressor, a pumped loop with plate heat exchanger to maximize tank stratification, enlarged heat exchangers, and relatively thin insulation to maximize the water storage volume.

Gluesenkamp, Kyle↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗

Multi-physics Modeling of Radiative Heat Transfer and Fluid Flow for the Reactor Cavity Cooling System

High-temperature gas-cooled reactors (HTGRs) are notable for their high thermal efficiency and potential for combined heat and power applications. These reactors are particularly appealing due to their advanced passive safety features. HTGRs utilize passive safety systems that function without requiring active components like pumps or compressors during emergencies. These reactor designs depend on a Reactor Cavity Cooling System (RCCS) to manage decay heat removal from the reactor pressure vessel (RPV) during accident conditions. The RCCS consists of vertical rectangular channels known as "risers" or riser ducts positioned around the RPV. These risers receive heat from the RPV through both convective and radiative heat transfer mechanisms. Understanding the interplay of multiple physical phenomena, such as fluid dynamics, heat transfer, and neutron interactions, is essential for the effective design and operation of nuclear reactors, particularly for systems like the RCCS. Multi-physics simulations provide a comprehensive approach to studying these interactions, offering detailed insights and enhancing accuracy. They are especially important in RCCS designs, where the interaction between radiative and convective heat transfer can significantly impact system performance. By leveraging multi-physics simulations, complex reactor behaviors can be modeled without compromising the fidelity of the underlying physical processes. This work aims to establish a robust methodology for coupling multiple physical processes in an air-cooled RCCS. By focusing on validating this multi-physics approach, the study involves designing test cases that simulate various conditions to verify the numerical models employed. The outcomes of this research will provide critical insights for accurately modeling and optimizing complex nuclear systems like the RCCS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Water separator for hydrogen steam injected turbine engine

A propulsion system for an aircraft includes a core engine that includes a core flow path where air is compressed in a compressor section, communicated to a combustor section, mixed with a hydrogen based fuel and ignited to generate a core gas flow that is expanded through a turbine section. The propulsion system includes a hydrogen fuel system that is configured to supply hydrogen fuel to the combustor through a fuel flow path, a condenser that is arranged along the core flow path and configured to condense water within the core gas flow, and a separator that includes an inlet, a primary water outlet and an exit that includes a plurality of exit guide vanes for straightening the core gas flow that proceeds through the exit. The exit guide vanes include a secondary water outlet for removing condensed water in the core gas flow that proceeds through the exit.

Terwilliger, Neil J.↗

Adjustable primary and supplemental power units

A propulsion system for an aircraft includes a core flow path in communication with a compressor section, combustor section and a turbine section. A first bottoming cycle system includes a bottoming working fluid flow in thermal communication with a high energy exhaust gas flow that is generated by the core engine. The first bottoming cycle is configured to recover power from the high energy exhaust gas flow in a first engine operating condition and in a second engine operating condition. A second bottoming cycle system is configured to recover power from the high energy exhaust gas flow in the first engine operating condition and not to recover power in a second engine operating condition.

MacDonald, Malcolm P.↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting magnet test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in Proton Improvement Plant PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyses heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool's capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, R. [Fermilab]↗

Integration and commissioning plan of Full Flow Purifier at Muon Campus

The Full Flow Purifier for Fermilab's Muon Campus uses a charcoal bed surrounded by a liquid nitrogen jacket to purify up to 240 g/s of helium gas. Fabrication by Ability Engineering Technology Inc. has been completed and the purifier delivered to Fermilab. It is the largest purifier to be used at Fermilab based on both capacity and size. A previous paper discussed the design of purifier for various operational conditions and horizontal shipping. The purifier is designed to withstand 5g force in vertical and 2g force in lateral and longitudinal directions. Transportation experience from vendor to Fermilab and within site is discussed. Integration of the purifier involved design and fabrication of a liquid nitrogen transfer line, regeneration system, and helium piping to connect it to Muon Campus cryogenic system. It also involved establishing electrical, instrumentation and controls connections to the system. Integration of the purifier is discussed in detail. The purifier is to be commissioned using up to 4 MYCOM helium compressors to supply helium and liquid nitrogen supplied by a 60,000-liter tank. Actual effectiveness of the 3-stream heat exchanger is to be estimated based on measured temperatures and flow rate. Impurity levels will be monitored at inlet and outlet of the purifier. Theoretical adsorption capacity of the purifier is calculated based on the measured temperatures and flowrates and is compared to actual adsorption capacity over time.

Subedi, J. [Fermilab] (ORCID:0009000185837576)↗

Modeling and Energy Analysis of Refrigeration Systems in Supermarkets: A Case Study

Refrigeration systems are the single largest consumer of electricity in supermarkets, accounting for approximately 40–60% of total store electricity use. As supermarkets face increasing pressures to improve efficiency and reduce operational costs, understanding the energy performance of refrigeration systems in supermarkets has become essential. In this paper, we investigate the energy performance and patterns of the refrigeration system using field measurements in one supermarket. The compressor coefficient of performance (COP) averaged 4.5 during nighttime steady-state operation, providing a practical efficiency benchmark. We develop simple physical-based load models for the display cases in the supermarket, where the refrigeration system uses R404A. The results show the display case models achieve a good agreement with measured data, validating its utility for energy estimation during unoccupied hours. Finally, the analysis reveals several challenges of data collection systems for refrigeration systems in the supermarket industry as well.

Chen, Yimin [ORNL] (ORCID:0000000338181655)↗

burtscher/LICO

LICO is a fast lossless image compressor. It takes BMP files (in 24-bit BMP3 format) as input.

Burtscher, Martin [Texas State Univ., San Marcos, ↗

Volumetric efficiency and pressure pulsations of a triplex reciprocating supercritical CO 2 pump

A reciprocating triplex pump has been integrated into a closed-loop supercritical carbon dioxide test facility. The pump is designed to compress liquid or supercritical carbon dioxide and has a maximum volumetric flow rate of 51 L/min. A sweep across the pump’s speed range of 100–1000 rev/min was performed with inlet conditions between 60 and 160 bar. The volumetric efficiency was found to increase as pump speed increased from 10 to 40 % before it plateaued at higher pump speeds. The mechanical efficiency increased linearly with pump speed and was not affected by system pressure. Pressure pulsations caused by the plungers and valves were also measured at each speed. Additionally, a 35-liter buffer volume, connected near the pump’s discharge was isolated at each speed to determine its effectiveness as a pulsation dampener. Overall the reciprocating pump was shown to perform exceptionally with liquid or supercritical inlet conditions applicable to many supercritical fluid applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation of Advanced Grid Support Functionalities by Smart Operation of Residential Loads with low Cost Converter Interface

This paper investigates a grid-supportive load concept for small-scale residential appliances, focusing on a residential refrigerator. Power consumption is adjusted based on grid conditions to achieve IEEE-1547 grid support functions. Two key aspects are presented: a low-cost refrigerator converter with Lyapunov energy function-based local controllers for speed control, and the impact on a standard microgrid system, demonstrating advanced grid support from the load side. This method enhances grid resilience and reliability and can be extended to other residential loads. The study contributes to efficient and robust grid-supportive load management systems, showing promising performance. This approach has the potential to improve overall grid stability and can be adapted for various types of residential appliances. The modeling and simulations in MATLAB/Simulink and PLECS confirm the feasibility and effectiveness of the proposed solution. Future work will explore real-world implementation and scalability of this concept for broader applications.

grid supportive loads (GSL)↗