Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Impact of Satellite Orbit Drift on Modis Earth Scene Observations Used in Calibration of the Reflective Solar Bands

After more than 20 years in orbit, NASA’s Terra and Aqua satellites have both started drifting away from their historically maintained orbits. The MODIS instruments on Terra and Aqua continue to collect valuable Earth observation data, but the changing orbits present a challenge for maintaining accurate calibration. The MODIS reflective solar bands (RSB), spanning the wavelength range from 412 nm to 2130 nm, are calibrated on orbit using a combination of regular data collections from an on-board solar diffuser, the Moon, and pseudo-invariant Earth scenes. Starting in the Collection 6 Level 1B (L1B) data products, the RSB calibration began using data from desert targets for a few of the visible bands to better track changes in the response versus scan angle that could not be captured by the on-board calibration. The use of Earth scene data has been extended recently for Terra MODIS calibration in Collection 6.1 (C6.1) and the upcoming Collection 7 (C7) L1B to also include data from ocean scenes and deep convective clouds (DCC). Drifts in both the orbit inclination and ground track of Terra and Aqua lead to changes in the solar illumination angles and satellite view angles of the Earth scenes. We discuss how these orbital changes impact the desert and DCC targets used for MODIS RSB calibration and present the accompanying changes made to our C6.1 and C7 calibration algorithms. We also discuss remaining future challenges, such as better characterization of bi-directional reflectance distribution functions, and possible alternative calibration strategies.

MODIS↗

Improvements of the Load Schedule for the Machine Calibration of a Strain-Gage Balance

The load schedule for the calibration of a six-component force balance in a calibration machine was improved. Now, single-component loads are repeated in regular intervals during the calibration. This approach has several advantages. First, the number of single-component loads increases to about twenty-two percent of all loads and load combinations. Consequently, more accurate numerical estimates of the primary bridge sensitivities can be obtained if global regression is used for the analysis of the calibration data. In addition, single-component repeats make it possible to track the stability of the applied loads during the calibration process. Finally, interactions of single-component repeats can be compared with interactions that are observed during the application of manual loads to the balance. Machine calibration and manual data sets of two force balances are used to illustrate benefits of the new load schedule. It is shown in the examples how differences between the observed interactions of machine calibration and manual data can be quantified. The suggested improvements can also be implemented in the load schedule for the machine calibration of a moment or direct-read balance as long as single-component loads are included that are described in the design load format of the balance.

wind tunnel test↗

Initial On-Orbit Spectral Calibration of the PACE Ocean Color Instrument

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Project Science Team has used Ocean Color Instrument (OCI) measurements of Fraunhofer lines in spectra of sunlight reflected by the solar diffuser and measurements of atmospheric absorption bands in cloudtop and ocean spectra to characterize the spectral calibration of OCI on orbit. Multiple lines have been analyzed for both the ultraviolet to visible (UVVIS, 340−607 nm) and visible to near-infrared (VISNIR, 597−897 nm) grating spectrographs. The spectrographs yield hyperspectral observations with 5 nm bandwidths and 0.625 nm sampling intervals. The on-orbit observations have been compared with the prelaunch spectral calibration of OCI performed by the Goddard Laser for Absolute Measurement of Radiance (GLAMR) during thermal vacuum testing to track any changes in the calibration since launch. The calibration analyzed the line positions and strengths for the Fraunhofer lines for each spectrograph by comparing the solar spectra measured by OCI with predicted solar spectra derived from the solar reference spectrum and the BRDF of the solar diffuser, convolved with the OCI relative spectral responses. The calibration also compared the line positions of the atmospheric absorption bands with the model transmissions used by the PACE Project. The line position comparisons show that the root mean square (RMS) spectral difference between the measured and predicted spectra is 0.15 nm, the average spectral shift is 0.062 nm, and the residual spectral dispersion over the wavelength range of the Fraunhofer lines is 0.17 nm. All three estimates of the spectral accuracy of OCI meet the instrument functional requirement of a spectral accuracy of 0.5 nm and are well within the 0.625 nm sampling interval of the data. The line strength comparisons between measured and predicted spectra are essentially the same. These results show that the spectral calibration of OCI on orbit has not drifted since the prelaunch calibration of OCI by GLAMR and that the on-orbit spectral calibration of OCI is stable over time. These results also provide a baseline for monitoring the future spectral performance of OCI on orbit.

Radiometric Calibration↗

A Method to Test Model Calibration Techniques: Preprint

This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Method to Test Model Calibration Techniques

This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based approaches to calibration and certification of nondestructive assay systems - 15615

Increasingly, model-based methods founded in physics are employed to calibrate, or extend the calibration of, nondestructive assay (NDA) systems used to characterize materials contaminated with plutonium, uranium, and other radioactive isotopes. In addition, modeling and mathematical methods are used to establish system parameters, correction factors, and measurement uncertainty components in NDA measurements. The methods combine the characteristics of the measurement configuration (detector structure, object shape and dimensions, source-detector distance and orientation, and collimation), generator knowledge of the waste composition, and known physical properties of the system in order to establish these parameters, factors, and components. These methods offer several important benefits over traditional methods used to test, calibrate, operate, and certify radiation measurement systems. First, instruments can be set up and put into service more quickly and correctly using a model-based approach. Second, calibrations can be performed, tested, and modified with reduced use of plutonium and uranium standards when modeling and mathematical methods are employed. Also, modeled approaches avoid calibration error resulting from heterogeneous source distribution. Moreover, the parameters can be installed quickly and simply in an office setting without the need for the safety, security, and safeguards considerations that are present when standards are used. Calibrations can also be tailored to fit unique or nonstandard container configurations (for example, over-packed drums), new container types, or specialized matrices. Finally, when modeling methods are applied, correction factors and measurement uncertainty elements can be developed, tested, and validated relatively quickly and without the need for surrogate matrix materials and a large number of test measurements. A combined gamma and neutron NDA system has recently been moved from Idaho National Laboratory to the TA 55 facility at Los Alamos National Laboratory (LANL). The system will be used to assay transuranic waste packaged in drums. After the move, the system was modified to replace degraded components and improve system performance. Afterwards, it was set up to assay different container types and to extend the calibration range. Model-based approaches were used to adapt the system to its new purpose at LANL. This report will describe the setup, calibration, and certification of the combined system at LANL Included in this discussion will be the measurement applications and details of the measurement methods. The steps in these processes that involved the use of modeling and mathematical calculations to replace or supplement more traditional methods will be identified and discussed. Finally, an overarching discussion of the methods and advantages of model-based methods to establish the properties of NDA systems will be presented. We conclude that validated mathematical methods offer a robust, flexible, and mature approach which is technically defensible from first principle physics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Building X-ray Diffraction Calibration Software

X-ray diffraction is a technique used to analyze the structure of crystals. It records the interference pattern created when x-rays travel through a crystal. Three dimensional structure can be inferred from these two dimensional diffraction patterns. Before the patterns can be analyzed, diffraction data must be precisely calibrated. Calibration is used to determine the experimental parameters of the particular experiment. This is done by fitting the experimental parameters to the diffraction pattern of a well understood crystal. Fit2D is a software package commonly used to do this calibration but it leaves much to be desired. In particular, it does not give very much control over the calibration of the data, requires a significant amount of manual input, does not allow for the calibration of highly tilted geometries, does not properly explain the assumptions that it is making, and cannot be modified. We build code to do this calibration while at the same time overcoming the limitations of Fit2D. This paper describes the development of the calibration software and the assumptions that are made in doing the calibration.

36 MATERIALS SCIENCE↗

Calibration, measurement, and characterization of soil moisture dynamics in a central Amazonian tropical forest

Soil moisture plays a key role in hydrological, biogeochemical, and energy budgets of terrestrial ecosystems. Accurate soil moisture measurements in remote ecosystems such as the Amazon are difficult and limited because of logistical constraints. Time domain reflectometry (TDR) sensors are widely used to monitor soil moisture and require calibration to convert the TDR's dielectric permittivity measurement (K a ) to volumetric water content (θ v ). In this study, our objectives were to develop a field-based calibration of TDR sensors in an old-growth upland forest in the central Amazon, to evaluate the performance of the calibration, and then to apply the calibration to determine the dynamics of soil moisture content within a 14.2 -m-deep vertical soil profile. Depth-specific TDR calibration using local soils in a controlled laboratory setting yielded a novel K a –θ v third-degree polynomial calibration. The sensors were later installed to their specific calibration depth in a 14.2-m pit. The widely used K a –θ v relationship (Topp model) underestimated the site-specific θ v by 22–42%, indicating significant error in the model when applied to these well-structured, clay-rich tropical forest soils. The calibrated wet- and dry-season θ v data showed a variety of depth and temporal variations highlighting the importance of soil textural differentiation, root uptake depths, as well as event to seasonal precipitation effects. Data such as these are greatly needed for improving our understanding of ecohydrological processes within tropical forests and for improving models of these systems in the face of changing environmental conditions.

54 ENVIRONMENTAL SCIENCES↗

Planck 2013 results. V. LFI calibration

We discuss the methods employed to photometrically calibrate the data acquired by the Low Frequency Instrument on Planck. Our calibration is based on a combination of the orbital dipole plus the solar dipole, caused respectively by the motion of the Planck spacecraft with respect to the Sun and by motion of the solar system with respect to the cosmic microwave background (CMB) rest frame. The latter provides a signal of a few mK with the same spectrum as the CMB anisotropies and is visible throughout the mission. In this data releasewe rely on the characterization of the solar dipole as measured by WMAP. We also present preliminary results (at 44 GHz only) on the study of the Orbital Dipole, which agree with the WMAP value of the solar system speed within our uncertainties. We compute the calibration constant for each radiometer roughly once per hour, in order to keep track of changes in the detectors’ gain. Since non-idealities in the optical response of the beams proved to be important, we implemented a fast convolution algorithm which considers the full beam response in estimating the signal generated by the dipole. Moreover, in order to further reduce the impact of residual systematics due to sidelobes, we estimated time variations in the calibration constant of the 30 GHz radiometers (the ones with the largest sidelobes) using the signal of an internal reference load at 4 K instead of the CMB dipole. We have estimated the accuracy of the LFI calibration following two strategies: (1) we have run a set of simulations to assess the impact of statistical errors and systematic effects in the instrument and in the calibration procedure; and (2) we have performed a number of internal consistency checks on the data and on the brightness temperature of Jupiter. Errors in the calibration of this Planck/LFI data release are expected to be about 0.6% at 44 and 70 GHz, and 0.8% at 30 GHz. Both these preliminary results at low and high ℓ are consistent with WMAP results within uncertainties and comparison of power spectra indicates good consistency in the absolute calibration with HFI (0.3%) and a 1.4σ discrepancy with WMAP (0.9%).

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of the ESPRESSO wavelength calibration using iodine absorption cell spectra

ABSTRACT High-quality wavelength calibration is crucial for science cases like radial-velocity studies of exoplanets, the search for a possible variation of fundamental constants, and the redshift drift experiment. However, for state-of-the-art spectrographs, it has become difficult to verify the wavelength calibration on sky because no astrophysical source provides spectra with sufficiently stable or accurate wavelength information. We therefore propose to use iodine absorption cells to validate the wavelength calibration. Observing a bright and featureless star through the iodine cell emulates an astrophysical target with exactly known spectral features that can be analysed like any other science target, allowing to verify the wavelength calibration derived from the internal calibration sources and to identify systematics in the data processing. As demonstration, we temporarily installed an $\mathrm{I_2}$ absorption cell at ESPRESSO. Employing a full forward modelling approach of the $\mathrm{I_2}$ spectrum, including the instrumental line-spread function, we demonstrate wavelength calibration accuracy at the level of a few $\mathrm{m\,s^{-1}}$. We also show that wavelength measurements do depend on the geometry of the light-injection into the spectrograph fibers. This highlights the importance of probing exactly the same light path as science targets, something not possible with internal calibration sources alone. We also demonstrate excellent radial-velocity stability at the ${{< 20\, \mathrm{cm\,s^{-1}}}}$ level in a full end-to-end fashion, from sky to data product. Our study therefore showcases the great potential of absorption cells for the verification and long-term monitoring of the wavelength calibration as well as the unique insights they can provide.

Schmidt, Tobias M. (ORCID:0000000248337273)↗

Automated Calibration of Parallel and Distributed Computing Simulators: A Case Study

Many parallel and distributed computing research results are obtained in simulation, using simulators that mimic real-world executions on some target system. Each such simulator is configured by picking values for parameters that define the behavior of the underlying simulation models it implements. The main concern for a simulator is accuracy: simulated behaviors should be as close as possible to those observed in the real-world target system. This requires that values for each of the simulator's parameters be carefully picked, or “calibrated,” based on ground-truth real-world executions. Examining the current state of the art shows that simulator calibration, at least in the field of parallel and distributed computing, is often undocumented (and thus perhaps often not performed) and, when documented, is described as a labor-intensive, manual process. In this work we evaluate the benefit of automating simulation calibration using simple algorithms. Specifically, we use a real-world case study from the field of High Energy Physics and compare automated calibration to calibration performed by a domain scientist. Our main finding is that automated calibration is on par with or significantly outperforms the calibration performed by the domain scientist. Furthermore, automated calibration makes it straightforward to operate desirable tradeoffs between simulation accuracy and simulation speed.

Mc donald, Jesse↗

Sequentially calibrating a Bayesian microsimulation model to incorporate new information and assumptions

Background: Microsimulation models are mathematical models that simulate event histories for individual members of a population. They are useful for policy decisions because they simulate a large number of individuals from an idealized population, with features that change over time, and the resulting event histories can be summarized to describe key population-level outcomes. Model calibration is the process of incorporating evidence into the model. Calibrated models can be used to make predictions about population trends in disease outcomes and effectiveness of interventions, but calibration can be challenging and computationally expensive. Methods: This paper develops a technique for sequentially updating models to take full advantage of earlier calibration results, to ultimately speed up the calibration process. A Bayesian approach to calibration is used because it combines different sources of evidence and enables uncertainty quantification which is appealing for decision-making. We develop this method in order to re-calibrate a microsimulation model for the natural history of colorectal cancer to include new targets that better inform the time from initiation of preclinical cancer to presentation with clinical cancer (sojourn time), because model exploration and validation revealed that more information was needed on sojourn time, and that the predicted percentage of patients with cancers detected via colonoscopy screening was too low. Results: The sequential approach to calibration was more efficient than recalibrating the model from scratch. Incorporating new information on the percentage of patients with cancers detected upon screening changed the estimated sojourn time parameters significantly, increasing the estimated mean sojourn time for cancers in the colon and rectum, providing results with more validity. Conclusions: A sequential approach to recalibration can be used to efficiently recalibrate a microsimulation model when new information becomes available that requires the original targets to be supplemented with additional targets.

60 APPLIED LIFE SCIENCES↗

Definition of Energy-Calibrated Spectra for National Reachback

Accurate energy calibration is critical for the timeliness and accuracy of analysis results of spectra submitted to National Reachback, particularly for the detection of threat items. Many spectra submitted for analysis include either a calibration spectrum using 137 Cs or no calibration spectrum at all. The single line provided by 137 Cs is insufficient to adequately calibrate nonlinear spectra. A calibration source that provides several lines that are well-spaced, from the low energy cutoff to the full energy range of the detector, is needed for a satisfactory energy calibration. This paper defines the requirements of an energy calibration for the purposes of National Reachback, outlines a method to validate whether a given spectrum meets that definition, discusses general source considerations, and provides a specific operating procedure for calibrating the GR-135.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Experimentally Enhanced Computation (ExEC): Traditional Calibration of Anisotropic Yield Functions

This memo addresses the calibration of anisotropic yield functions based on data obtained from a series of uniaxial tension specimens extracted from a tubular Al 7079 circular cylindrical extrusion. Achieving the calibrations completed an important step in the Experimentally Enhanced Computations (ExEC) project. The focus of the project is on novel calibration approaches that will be based on advanced diagnostics and numerical simulations with the intention of reducing the overall calibration effort. The test data used here resulted from traditional tensile tests on specimens cut at 12 orientations within the extrusion. Two anisotropic yield surfaces — Hill’s (1948) and Barlat’s (2005) — were calibrated based on the test data. The methods used to conduct the calibrations are described, and the results show that the material exhibited significant yield anisotropy. The larger number of parameters in Barlat’s yield function allowed it to fit the test data more accurately than Hill’s. Although work remains to assess the sensitivity of the calibrated model parameters to various factors, the methods implemented and the results obtained here provide bases for further work and useful benchmarks for future calibrations to be conducted using the novel approach.

36 MATERIALS SCIENCE↗

Forward Global Photometric Calibration of the Dark Energy Survey

Many scientific goals for the Dark Energy Survey (DES) require the calibration of optical/NIR broadband b = grizY photometry that is stable in time and uniform over the celestial sky to one percent or better. It is also necessary to limit to similar accuracy systematic uncertainty in the calibrated broadband magnitudes due to uncertainty in the spectrum of the source. Here we present a "Forward Global Calibration Method (FGCM)" for photometric calibration of the DES, and we present results of its application to the first three years of the survey (Y3A1). The FGCM combines data taken with auxiliary instrumentation at the observatory with data from the broadband survey imaging itself and models of the instrument and atmosphere to estimate the spatial and time dependences of the passbands of individual DES survey exposures. "Standard" passbands that are typical of the passbands encountered during the survey are chosen. The passband of any individual observation is combined with an estimate of the source spectral shape to yield a magnitude in the standard system. This "chromatic correction" to the standard system is necessary to achieve subpercent calibrations and in particular, to resolve ambiguity between the broadband brightness of a source and the shape of its SED. The FGCM achieves a reproducible and stable photometric calibration of standard magnitudes of stellar sources over the multiyear Y3A1 data sample with residual random calibration errors of per exposure. The accuracy of the calibration is uniform across the DES footprint to within . The systematic uncertainties of magnitudes in the standard system due to the spectra of sources are less than for main-sequence stars with .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sky camera geometric calibration using solar observations

A camera model and associated automated calibration procedure for stationary daytime sky imaging cameras is presented. The specific modeling and calibration needs are motivated by remotely deployed cameras used to forecast solar power production where cameras point skyward and use 180° fisheye lenses. Sun position in the sky and on the image plane provides a simple and automated approach to calibration; special equipment or calibration patterns are not required. Sun position in the sky is modeled using a solar position algorithm (requiring latitude, longitude, altitude and time as inputs). Sun position on the image plane is detected using a simple image processing algorithm. The performance evaluation focuses on the calibration of a camera employing a fisheye lens with an equisolid angle projection, but the camera model is general enough to treat most fixed focal length, central, dioptric camera systems with a photo objective lens. Calibration errors scale with the noise level of the sun position measurement in the image plane, but the calibration is robust across a large range of noise in the sun position. In conclusion, calibration performance on clear days ranged from 0.94 to 1.24 pixels root mean square error.

54 ENVIRONMENTAL SCIENCES↗

Hydrologic calibration of paired watersheds using a MOSUM approach

Paired watershed studies have historically been used to quantify hydrologic effects of land use and management practices by concurrently monitoring two neighboring watersheds (a control and a treatment) during the calibration (pre-treatment) and post-treatment periods. This study characterizes seasonal water table and flow response to rainfall during the calibration period and tests a change detection technique of moving sums of recursive residuals (MOSUM) to select calibration periods for each control-treatment watershed pair when the regression coefficients for daily water table elevation (WTE) were most stable to reduce regression model uncertainty. The control and treatment watersheds included 1–3 year intensively managed loblolly pine ( Pinus taeda L. ) with natural understory, same age loblolly pine intercropped with switchgrass ( Panicum virgatum ), 14–15 year thinned loblolly pine with natural understory (control), and switchgrass only. Although monitoring during the calibration period spanned 2009 to 2012, silvicultural operational practices that occurred during this period such as harvesting of existing stand and site preparation for pine and switchgrass establishment may have acted as external factors, potentially shifting hydrologic calibration relationships between control and treatment watersheds. Results indicated that MOSUM was able to detect significant changes in regression parameters for WTE due to silvicultural operations. This approach also minimized uncertainty of calibration relationships which could otherwise mask marginal treatment effects. All calibration relationships developed using this MOSUM method were quantifiable, strong, and consistent with Nash–Sutcliffe Efficiency (NSE) greater than 0.97 for WTE and NSE greater than 0.92 for daily flow, indicating its applicability for choosing calibration periods of paired watershed studies.

54 ENVIRONMENTAL SCIENCES↗