Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

PACE OCI Lunar Calibration: Initial Results

Launched in February 2024, the Ocean Color Instrument (OCI) onboard NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission has started performing its monthly lunar calibrations at ±7degreeslunar phase angle in March 2024. In this paper, we will describe the OCI lunar calibration methodology and show the results of lunar calibration events during the initial months of PACE/OCI operation. A key difference of OCI lunar calibration from heritage sensors is that the lunar disk integrated irradiance is computed from lunar pixel radiance and sampling distance instead of the instrument’s IFOV. PACE provided a near constant sweep rate during lunar calibration allowing accurate determination of OCI pixel sampling extent. OCI performs lunar calibration in baseline science mode with 282 hyperspectral bands from 315 –895 nm and 7 shortwave infrared bands(940 -2260 nm). For each OCI band, we compute the integrated lunar disk irradiance, and compare the result with a lunar irradiance model (ROLO)prediction. The early results presented here clearly show that OCI’s lunar image acquisition is working as intended and will provide accurate data for OCI’s on-orbit radiometric characterization. The hyperspectral lunar irradiances provided by OCI are expected to become a valuable data set for the evaluation of lunar irradiance models.

calibration↗

Spatiotemporal Automatic Calibration of Infrastructure Lidar, Radar, and Camera with a Global Navigation Satellite System: Preprint

Robust and accurate perception is important for modern intelligent transportation systems (ITS), which use sensors of various modalities for data fusion to create a digital twin of an intersection. Sensor calibration is an important process that creates a unified coordinate frame for the sensor output data so that it can be used for data fusion. Classical approaches for sensor calibration are time-consuming, require an overlapping field of view for feature matching, and are not feasible for ITS application as they cause disruptions in the flow of traffic. In this paper, we present a spatiotemporal automatic calibration approach to calibrate multiple infrastructure lidar, radar, and cameras installed at a traffic intersection. The approach uses global navigation satellite system (GNSS) positioning information shared by connected vehicles, and when the vehicle is detected by the sensor, we match the sensor detections with the GNSS coordinates. The proposed algorithm is evaluated with a real-world dataset utilizing detections from two radars, cameras, and lidars with a test vehicle instrumented with a post-processing kinematic (PPK)-corrected GNSS driving past the sensors installed at a four-way traffic intersection. The experimental results show that the proposed automatic calibration approach can achieve the transformation with a root mean squared error of less than 0.5 for radar and lidar and less than 2 for camera detections. The ability to rapidly calibrate sensors not only benefits initial installations, but can also be used for system health monitoring, while utilizing available connected vehicle data to test the real-time sensor fidelity and operational status.

ADVANCED PROPULSION SYSTEMS↗

Application of Indirect Quantification of 133mXe to Calibration of HPGe Detector

The INL Noble Gas Laboratory provides intercomparison samples for the noble gas analysis laboratories as part of the CTBTO PrepCom IMS. Xe-133m is one of the four relevant radionuclides in nuclear explosion monitoring. Without commercially available Xe-133m calibration standards laboratories must create and improve calibration methods. Improvements in calibration methods at the INL NGL benefit the CTBTO PrepCom through better certified values for Xe-133m intercomparison samples. Calibration of High Purity Germanium detectors for Xe-133m quantification is complicated by the coexistence of Xe-133 in samples under analysis. Xe-133 is typically produced in larger quantities, has higher gamma emission probabilities, and its gammas are detected more efficiently than Xe-133m. Xe-133m activity of samples can be indirectly inferred through the 133:133m activity ratio of a batch of material, and the Xe-133 counts in the assay of a small aliquot of the same material. This indirect quantification method can be leveraged to perform detector calibrations for quantification of Xe-133m. Calibrations can be performed by inferring the Xe-133m to certify the sample, and direct counting to determine detector efficiency. A comparison of method results will be shown.

133mXe↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emulator-based Bayesian calibration of a subglacial drainage model

Subglacial drainage models, often motivated by the relationship between hydrology and ice flow, sensitively depend on numerous unconstrained parameters. We explore using borehole water-pressure time series to calibrate the uncertain parameters of a popular subglacial drainage model, taking a Bayesian perspective to quantify the uncertainty in parameter estimates and in the calibrated model predictions. To reduce the computation time associated with Markov Chain Monte Carlo sampling, we construct a fast Gaussian process emulator to stand in for the subglacial drainage model. We first carry out a calibration experiment using synthetic observations consisting of model simulations with hidden parameter values as a demonstration of the method. Using real borehole water pressures measured in western Greenland, we find meaningful constraints on four of the eight model parameters and a factor-of-three reduction in uncertainty of the calibrated model predictions. These experiments illustrate Gaussian process-based Bayesian inference as a useful tool for calibration and uncertainty quantification of complex glaciological models using field data. However, significant differences between the calibrated model and the borehole data suggest that structural limitations of the model, rather than poorly constrained parameters or computational cost, remain the most important constraint on subglacial drainage modelling.

58 GEOSCIENCES↗

Machine Learning Calibration of Groundwater Table Depth in ELM: Impact on Land Surface Hydrology and Land‐Atmosphere Fluxes

Accurate representation of groundwater table depth (GWTD) is crucial for simulating hydrological cycling in Earth system models (ESM). Nevertheless, there is a notable gap in the literature regarding the validation of GWTD simulations in ESMs and their subsequent impact on downstream hydrological components. This study explores the calibration of parameterization of global GWTD using machine learning within the Energy Exascale Earth System Model (E3SM) Land Model (ELM). Despite achieving significant gains in simulating GWTD through calibration, offline ELM simulations unexpectedly show that these improvements do not translate to substantial enhancements in model performance for other key hydrological variables, including soil moisture (SM), runoff, groundwater contribution to runoff or base flow index (BFI), and evapotranspiration and its partitioning. The performance in SM and runoff was even degraded in some regions, while BFI was mostly overestimated. Although there is significant improvement in GWTD within the critical range of 1–5 m, where groundwater traditionally influences land surface energy fluxes, these improvements occurred mostly in humid areas where the impact of GWTD on surface processes is minimal. Although the impacts of model calibration are generally small in offline ELM simulations, coupled land-atmosphere simulations exhibit much stronger responses to GWTD calibration, highlighting the role of land-atmosphere feedbacks in Earth system modeling. These findings underscore the need for integrated calibration strategies that simultaneously optimize multiple hydrological variables. However, if a single-variable approach is necessary, it is crucial to establish clear priorities for calibration, identifying the most critical variables that have the greatest impact on overall model performance.

Fang, Yilin [Pacific Northwest National Laboratory↗

Calibrating Microscopic Car-Following Models for Adaptive Cruise Control Vehicles: Multiobjective Approach

Adaptive cruise control (ACC) vehicles are the first step toward comprehensive vehicle automation. However, the impacts of such vehicles on the underlying traffic flow are not yet clear. Therefore, it is of interest to accurately model vehicle-level dynamics of commercially available ACC vehicles so that they may be used in further modeling efforts to quantify the impact of commercially available ACC vehicles on traffic flow. Importantly, not only model selection but also the calibration approach and error metric used for calibration are critical to accurately model ACC vehicle behavior. In this work, we explore the question of how to calibrate car following models to describe ACC vehicle dynamics. Specifically, we apply a multi-objective calibration approach to understand the tradeoff between calibrating model parameters to minimize speed error vs. spacing error. Three different car-following models are calibrated for data from six vehicles. The results are in line with recent literature and verify that targeting a low spacing error does not compromise the speed accuracy whether the opposite is not true for modeling ACC vehicle dynamics.

33 ADVANCED PROPULSION SYSTEMS↗

Improving gas adsorption modeling for MOFs by local calibration of Hubbard U parameters

While computational screening with density functional theory (DFT) is frequently employed for the screening of metal–organic frameworks (MOFs) for gas separation and storage, commonly applied generalized gradient approximations (GGAs) exhibit self-interaction errors, which hinder the predictions of adsorption energies. We investigate the Hubbard U parameter to augment DFT calculations for full periodic MOFs, targeting a more precise modeling of gas molecule–MOF interactions, specifically for N2, CO2, and O2. We introduce a calibration scheme for the U parameter, which is tailored for each MOF, by leveraging higher-level calculations on the secondary building unit (SBU) of the MOF. When applied to the full periodic MOF, the U parameter calibrated against hybrid HSE06 calculations of SBUs successfully reproduces hybrid-quality calculations of the adsorption energy of the periodic MOF. The mean absolute deviation of adsorption energies reduces from 0.13 eV for a standard GGA treatment to 0.06 eV with the calibrated U, demonstrating the utility of the calibration procedure when applied to the full MOF structure. Furthermore, attempting to use coupled cluster singles and doubles with perturbative triples calculations of isolated SBUs for this calibration procedure shows varying degrees of success in predicting the experimental heat of adsorption. It improves accuracy for N2 adsorption for cases of overbinding, whereas its impact on CO2 is minimal, and ambiguities in spin state assignment hinder consistent improvements of O2 adsorption. Our findings emphasize the limitations of cluster models and advocate the use of full periodic MOF systems with a calibrated U parameter, providing a more comprehensive understanding of gas adsorption in MOFs.

Chemistry↗

Calibrating a finite-strain phase-field model of fracture for bonded granular materials with uncertainty quantification

To study the mechanical behavior of mock high explosives, an experimental and simulation program was developed to calibrate, with quantified uncertainty, a material model of the bonded granular material Idoxuridine and nitroplasticized Estane-5703. This paper reports on the efficacy of such a framework as a generalizable methodology for calibrating material models against experimental data with uncertainty quantification. Additionally, this paper studies the effect of two manufacturing temperatures and three initial granular configurations on the unconfined compressive behavior of the resulting bonded granular materials. In each of these cases, the same calibration framework was used; in that, hundreds of high-fidelity direct numerical simulations using a new, graphics processing unit-enabled, high-performance finite element method software, Ratel, were run to calibrate a finite-strain phase-field fracture model against experimental data. It was found that manufacturing temperature influenced the elastic response of the mock high explosives, with higher temperatures yielding a stiffer response. By contrast, it was found that the initial configuration of the grains had a negligible impact on the overall behavior of the mock high explosives though it remains possible that local damage accumulation within the specimens could be altered by the initial configurations. Overall, the calibration framework was successful at creating well-calibrated models, showing its usefulness as an engineering and scientific tool.

36 MATERIALS SCIENCE↗

The Simons Observatory: gain, bandpass and polarization-angle calibration requirements for B-mode searches

We quantify the calibration requirements for systematic uncertainties for next-generation ground-based observatories targeting the large-angle B-mode polarization of the Cosmic Microwave Background, with a focus on the Simons Observatory (SO). We explore uncertainties on gain calibration, bandpass center frequencies, and polarization angles, including the frequency variation of the latter across the bandpass. We find that gain calibration and bandpass center frequencies must be known to percent levels or less to avoid biases on the tensor-to-scalar ratio r on the order of Δ r∼10-3, in line with previous findings. Polarization angles must be calibrated to the level of a few tenths of a degree, while their frequency variation between the edges of the band must be known to O(10) degrees. Given the tightness of these calibration requirements, we explore the level to which residual uncertainties on these systematics would affect the final constraints on r if included in the data model and marginalized over. We find that the additional parameter freedom does not degrade the final constraints on r significantly, broadening the error bar by O(10%) at most. We validate these results by reanalyzing the latest publicly available data from the collaboration within an extended parameter space covering both cosmological, foreground and systematic parameters. Finally, our results are discussed in light of the instrument design and calibration studies carried out within SO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full calibration of the tomographic redshift distribution from the HSC PDR3 Shape Catalog with DESI

The calibration of tomographic redshift distributionsis essential for cosmological analysis of weak lensing data.In this work, we calibrate all four tomographic bins of the Hyper Suprime Camera (HSC) weak lensing catalog with the Dark Energy Spectroscopic Instrument (DESI) Data Release 1 and 2 using the clustering redshifts technique. We include z > 1.2 redshift sources such as emission line galaxies (ELG) and quasars (QSO) sources in our calibration, which were not available in the previous HSC calibration (Rau et al. (2022), Mon. Not. Roy. Astron. Soc. 524 (2023) 5109), allowing a complete calibration of all the redshift bins. We find the first tomographic bin exhibits a small shift towards low redshifts. The second bin is in good agreement with the photometric calibration, while third and fourth bin exhibit a shift towards higher redshifts. However, these shifts are considerably smaller than the shifts obtained in the HSC Year 3 cosmic shear analyses. We evaluate the impact of galaxy bias and magnification effects from all the samples on the measurements, finding them to be small, and we propose corrections to reduce them further. Specifically, we relax the assumption of linear bias and only assume no redshift evolution of the cross-correlation coefficient, allowing us to leverage smaller clustering scales. We model the redshift distributions with splines and compare our results to previous analyses as well as to other parameterizations found in literature. For the two high-redshift tomographic bins, we find the shifts to higher redshifts with respect to the measurements performed in Rau+2022 to be Δz$_{3}$ =-0.039$^{+0.020}$$_{-0.021}$ and Δz$_{4}$ = -0.048$^{+0.012}$$_{-0.012}$.

Choppin de Janvry, J. [LBL, Berkeley; UC, Berkeley↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with aspheric x-ray optics

High-accuracy surface metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate x-ray light with nanometer-scale wavelengths. The current and potential capabilities of x˗ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. Metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for fabrication of slightly curved x-ray optics. However, for even moderately curved aspherical x-ray mirrors the flat-reference calibration is not sufficiently accurate. For micro-stitching interferometry developed for surface measurements with curved x-ray mirrors, the tool aberration errors are known to be transferred into the optical surface topography of x-ray mirrors. Our approach to improving metrology is to thoroughly calibrate the measuring tool and apply the results of the calibration to deconvolution of the measured data. Here we explore the application of a recently developed technique for calibrating the instrument transfer function (ITF) of 3D optical surface profilers to metrology with significantly curved x-ray optics. The technique, based on test standards patterned with two-dimensional (2D) binary pseudo-random arrays (BPRAs), employs the unique properties of the BPRA patterns in the spatial frequency domain. The inherent 2D power spectral density of the pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field of view of an instrument. The high efficacy of the technique has been previously demonstrated in application to metrology with flat and slightly curved optics. Here, we concentrate on development of an efficient fabrication process for production of highly randomized (HR) BPRA test standards on flat and 500-mm spherical optical substrates. We also compare and discuss the results of the ITF calibration of an interferometric microscope when using the HR BPRA standards on flat and curved substrates.

Munechika, Keiko↗

Determination of jet calibration and energy resolution in proton–proton collisions at $\sqrt{s} = 8~\hbox {TeV}$ using the ATLAS detector

The jet energy scale, jet energy resolution, and their systematic uncertainties are measured for jets reconstructed with the ATLAS detector in 2012 using proton–proton data produced at a centre-of-mass energy of 8 TeV with an integrated luminosity of 20fb -1 . Jets are reconstructed from clusters of energy depositions in the ATLAS calorimeters using the anti-k t algorithm. A jet calibration scheme is applied in multiple steps, each addressing specific effects including mitigation of contributions from additional proton–proton collisions, loss of energy in dead material, calorimeter non-compensation, angular biases and other global jet effects. The final calibration step uses several in situ techniques and corrects for residual effects not captured by the initial calibration. Furthermore, these analyses measure both the jet energy scale and resolution by exploiting the transverse momentum balance in γ + jet, Z + jet, dijet, and multijet events. A statistical combination of these measurements is performed. In the central detector region, the derived calibration has a precision better than 1% for jets with transverse momentum 150 GeV < p T < 1500 GeV, and the relative energy resolution is (8.4 ± 0.6)% for p T =100 GeV and (23 ± 2)% for p T =20 GeV. The calibration scheme for jets with radius parameter R = 1.0, for which jets receive a dedicated calibration of the jet mass, is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New techniques for jet calibration with the ATLAS detector

A determination of the jet energy scale is presented using proton–proton collision data with a centre-of-mass energy of $\sqrt{s}$ = 13 TeV, corresponding to an integrated luminosity of 140 fb -1 collected using the ATLAS detector at the LHC. Jets are reconstructed using the ATLAS particle-flow method that combines charged-particle tracks and topo-clusters formed from energy deposits in the calorimeter cells. The anti-k t jet algorithm with radius parameter R = 0.4 is used to define the jet. Novel jet energy scale calibration strategies developed for the LHC Run 2 are reported that lay the foundation for the jet calibration in Run 3. Jets are calibrated with a series of simulation-based corrections, including state-of-the-art techniques in jet calibration such as machine learning methods and novel in situ calibrations to achieve better performance than the baseline calibration derived using up to 81 fb -1 of Run 2 data. The performance of these new techniques is then examined in the in situ measurements by exploiting the transverse momentum balance between a jet and a reference object. The b -quark jet energy scale using particle flow jets is measured for the first time with around 1% precision using $\gamma$+jet events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a simplified calibrated building simulation model of a supermarket for proposed ECMs and control strategies impact evaluation

Calibrated building energy simulation is an important pathway to more energy-efficient buildings, but the information requirements of some approaches to this problem are significant. This is particularly true for supermarkets and other so-called “big-box” retail stores. Another characteristic of supermarkets is the significant interaction between Heating Ventilating and Air Conditioning (HVAC) and refrigeration systems in these buildings. These buildings could contain a wide variety of systems and a degree of load diversity that makes calibrated modeling a challenge. This paper describes a simplified approach that uses OpenStudio and EnergyPlus to combine known building parameters with “typical” parameters, resulting in a simplified building that is amenable to calibration. This approach was applied to a big-box store located in Nashville, Tennessee, and a calibrated model was obtained that was used to study potential energy conservation measures. Further, the paper also explores the capabilities of whole-building energy modeling tools, such as EnergyPlus, for modeling the HVAC controls and sequences and their impact evaluation. Although some measures are precluded by the model simplicity, several measures were found to improve the efficiency of the model and demonstrate that the simplified modeling approach is effective. Practical Application: This paper introduces a hybrid approach of building energy model calibration using limited information available from the actual building in combination with characteristics of a “typical” building of the same type. This hybrid approach would also be applicable for other building types than discussed in this paper to calibrate the building energy model using limited information from the actual building.

42 ENGINEERING↗

Automatic Calibration of a Geomechanical Model from Sparse Data for Estimating Stress in Deep Geological Formations

Summary In this study, we demonstrate geomechanical modeling with fully automatic parameter calibration to estimate the full geomechanical stress fields of a prospective US carbon dioxide (CO2) storage site, based on sparse measurement data. The goal is to compute full stress tensor field estimates (principal stresses and orientations) that are maximally compatible with observations within the constraints of the model assumptions, thereby extending pointwise, incomplete partial stress measurement to a simulated full formation stress field, as well as a rough assessment of the associated error. We use the Perch site, located in Otsego County, Michigan, USA, as our case study. The input data consist of partial stress tensor information inferred from in-situ borehole tests, geophysical well logs, and processing of seismic data. A static earth model (SEM) of the site was developed, and geomechanical simulation functionality of the open-source MATLAB Reservoir Simulation Toolbox (MRST) was used to model the stress field. Adjoint-based nonlinear optimization was used to adjust boundary conditions and material properties to calibrate simulated results of observations. Results were interpreted through a Bayesian framework. The focus of this paper is to demonstrate how the fully automatic calibration procedure works and discuss the results obtained; it does not attempt a detailed analysis of the stress field in the context of the proposed CO2 storage initiatives. Our work is part of a larger effort to noninvasively determine in-situ stresses in deep formations considered for CO2 storage. Guided by previously published research on geomechanical model calibration, our work presents a novel calibration approach supporting a potentially large number of linear or nonlinear calibration parameters to produce results optimally agreeing with available measurements and thus extend partial pointwise estimates to full tensor fields compatible with the physics of the site.

Engineering↗

PBX9502 PAGOSA/SURF Calibration for 100 µm Grid Size

There are two methods to calibrate the SURF reactive burn explosives model.The first is to calibrate using Pop plot data. Because there are only two main parameters in SURF, called A and B, there is just enough flexibility in SURF to determine the Pop plot line, i.e., equivalent information to a slope and a single point on the line. However, due to the linearity of the Pop plot being based on logarithmic scales, a slight deviation off the Pop plot (though the fit to the Pop plot might be very good overall) can make considerable difference when comparing with the velocity profile data. The second calibration method thusly focuses strongly on matching entire velocity profile data. This is to say that individual velocity profiles extracted from embedded gages (in the case of PBX 9502, we refer to R. Gustavsen’s experimental data) may fit poorly, while the overall fit to the Pop plot may seem reasonable. In addition, there are other factors that could produce slightly different calibrations for SURF, while leading to an overall acceptable fit to data. One of those may be the physics code used and here we use Pagosa. Another is mesh size dependence. A third one stems from fitting a reactive burn model being done in conjunction with an equation of state (EOS) of the reactants and one for the products – different EOS can result in slightly different parameterizations. Finally, there are several secondary material parameters in SURF, and the overall fit will depend on the entire parameterization. The goal of this report is to clarify some of our previously made statements about SURF calibration, as well as to redo a systematic calibration using 100 µm grid resolution.

42 ENGINEERING↗