Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Understanding Multifamily Energy Use in the Greater Nashville and Hopkinsville-Bowling Green Area: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Multifamily Energy Use in Rural Midwest Climate Zone 6A: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy 101: Energy Efficient Commercial Buildings

Learn how commercial buildings can incorporate whole-building design to save energy and money while enhancing performance and comfort. This video highlights several energy-saving features of the Research Support Facility at the Energy Department's National Renewable Energy Laboratory-a model for high-performance office building design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Use Analysis and Target Requirements

This is an American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) building energy performance standard. ORNL developed the high-efficiency building energy performance targets tables in this standard that enabled it to offer, for the first time, a methodology to comply with the standard solely by the achievement of its performance targets.

Sharp, Terry R.↗

An integrated environmental and health performance quantification model for pre-occupancy phase of buildings in China

To comprehensively pre-evaluate the damages to both the environment and human health due to construction activities in China, this paper presents an integrated building environmental and health performance (EHP) assessment model based on the Building Environmental Performance Analysis System (BEPAS) and the Building Health Impact Analysis System (BHIAS) models and offers a new inventory data estimation method. The new model follows the life cycle assessment (LCA) framework and the inventory analysis step involves bill of quantity (BOQ) data collection, consumption data formation, and environmental profile transformation. The consumption data are derived from engineering drawings and quotas to conduct the assessment before construction for pre-evaluation. The new model classifies building impacts into three safeguard areas: ecosystems, natural resources and human health. Thus, this model considers environmental impacts as well as damage to human wellbeing. The monetization approach, distance-to-target method and panel method are considered as optional weighting approaches. Finally, nine residential buildings of different structural types are taken as case studies to test the operability of the integrated model through application. The results indicate that the new model can effectively pre-evaluate building EHP and the structure type significantly affects the performance of residential buildings.

54 ENVIRONMENTAL SCIENCES↗

Commercial Building Energy Saver, Web App v2.0

The CBES App is a web-based toolkit for use by small businesses and building owners and operators of small and medium size commercial buildings to perform energy benchmarking and retrofit analysis for buildings. The CBES App analyzes the energy performance of user's building for pre- and post-retrofit, in conjunction with user's input data, to identify recommended retrofit measures, energy savings and economic analysis for the selected measures.

Hong, Tianzhen↗

Commercial Building Energy Saver, Web App

The CBES App is a web-based toolkit for use by small businesses and building owners and operators of small and medium size commercial buildings to perform energy benchmarking and retrofit analysis for buildings. The CBES App analyzes the energy performance of user's building for pre-and posto-retrofit, in conjunction with user's input data, to identify recommended retrofit measures, energy savings and economic analysis for the selected measures. The CBES App provides energy benchmarking, including getting an EnergyStar score using EnergyStar API and benchmarking against California peer buildings using the EnergyIQ API. The retrofit analysis includes a preliminary analysis by looking up retrofit measures from a pre-simulated database DEEP, and a detailed analysis creating and running EnergyPlus models to calculate energy savings of retrofit measures. The CBES App builds upon the LBNL CBES API.

Hong, Tianzhen↗

Modeling and analysis of heat emissions from buildings to ambient air

Heat emissions from buildings is a significant source of anthropogenic heat influencing the urban microclimate; however, they are usually oversimplified in urban climate and microclimate modeling. This study developed a bottom-up physics-based approach to calculate heat emissions from buildings to the ambient air and implemented the approach in EnergyPlus. In this work, a simple result verification was conducted by comparing the EnergyPlus simulated results against the spreadsheet calculations. Simulations covering 16 commercial building types, four climates, and two energy efficiency levels were conducted to understand and evaluate the building heat emissions and their temporal patterns as well as three major components: (1) building envelope (convective heat transfer to ambient air), (2) zones (air exfiltration and exhaust air), and (3) HVAC systems (relief air and heat rejection from condensers or cooling towers). The main findings are: (1) heat emissions are usually higher than the site energy use (about 2.5 times), and their dynamics should be considered; (2) building characteristics and their energy systems lead to differences in heat emission contributions from the three components, and their dynamics, for example, in the warehouse models, the envelope component accounts for 90.4%, while it is 12.7% for the large office models; (3) for most building typologies, the climate has a strong impact on heat emissions, for example, buildings with dominant heat emissions from the zone exhaust air and/or the HVAC reject heat, a general decrease in heat emissions in hotter climates is observed, while envelope-dominated buildings show the opposite; and (4) building technologies that reduce energy use in buildings may perform differently in reducing heat emissions. The developed heat emissions calculation method can be adopted in EnergyPlus and most other building energy modeling programs. It can provide dynamic building heat emissions as an input to urban climate computational fluid dynamics (CFD) models at a higher spatial and temporal resolution than is currently available, to improve the simulation accuracy of the urban microclimate and capture the urban heat island effect and urban overheating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A hardware-in-the-loop approach for laboratory performance verification of flexible building equipment in a typical commercial building

The overall objective of the project is to develop datasets that measure the holistic load flexibility performance of a suite of commonly-used commercial building HVAC and thermal storage equipment using a hardware-in-the-loop test method. The development of the software side of the hardware-in-the-loop flexible load testbed is summarized in this paper.

Chen, Zhelun↗

Bioinjection Performance Review for the Building 100 Area and 4.5 Acre Site at the Pinellas County, Florida, Site

This document provides a summary of a review of the performance of bioinjection activities at the Building 100 Area and the 4.5 Acre Site at the Pinellas County, Florida, Site since 2010, determines how best to optimize future injection events, and identifies the approach for the bioinjection event in 2016 at (1) the 4.5 Acre Site and (2) the Essentra property at the Building 100 Area. Because this document describes the next bioinjection event at the 4.5 Acre Site, it also serves as an addendum to the Interim Remedial Action Plan for Emulsified Edible Oil Injection at the 4.5 Acre Site (DOE 2013). In addition, this document revises the injection layout and injection intervals for the Essentra property that were originally described in the Interim Corrective Measure Work Plan for Source and Plume Treatment at the Building 100 Area (DOE 2014), and is a de facto update of that document. Bioinjection consists of injection of emulsified vegetable oil (EVO) and the microorganism Dehalococcoides mccartyi (DHM; formerly known as Dehalococcoides ethenogenes) into the subsurface to enhance biodegradation of trichloroethene (TCE), dichloroethene (DCE), and vinyl chloride (VC). VC is the only contaminant that exceeds its maximum contaminant level (10 micrograms per liter onsite and 1 microgram per liter onsite) on the 4.5 Acre Site and the Essentra property. Bioinjection was conducted at the 4.5 Acre Site in 2010 and 2013. Approximately 49,900 gallons of EVO and DHM were injected at 95 injection points in February 2010, and approximately 22,900 gallons of EVO and DHM were injected at 46 injection points in July 2013. The injection locations are shown on Figure 1. The goal of bioinjection at the 4.5 Acre Site is to decrease contaminant concentrations to maximum contaminant levels along the west and southwest property boundaries (to meet risk–based corrective action requirements) and to minimize the extent of the contaminant plume in the interior of the site. Bioinjection was conducted at the Building 100 Area in 3 phases from October 2014 through November 2015 (Figures 2–4). Approximately 32,850 gallons of EVO and DHM were injected using 62 temporary injection points in the onsite plumes in October and November 2014, 16,500 gallons were injected using 33 temporary injection points in the offsite plumes in February 2015, and 51,000 gallons were injected beneath the building using 8 horizontal wells in November 2015. The goal of bioinjection at the Building 100 Area is to enhance contaminant biodegradation to stabilize or shrink the contaminant plumes.

54 ENVIRONMENTAL SCIENCES↗

Streamlining Building Efficiency Evaluation with DOE's Asset Score Preview

Building Energy Asset Score (Asset Score), developed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE), is a tool to help building owners and managers assess the efficiency of a building's energy-related systems and encourage investment in cost-effective improvements. The Asset Score uses an EnergyPlus model to provide a quick assessment of building energy performance with minimum user inputs of building characteristics and identifies upgrade opportunities. Even with a reduced set of user inputs, data collection remains a challenge for wide-spread adoption, especially when evaluating a large number of buildings. To address this, Asset Score Preview was developed to allow users to enter as few as seven building characteristics to quickly assess their buildings before a more in-depth analysis. A streamlined assessment from Preview to full Asset Score provides an easy entry point and also enables users who manage a large number of buildings to screen and prioritize buildings that can benefit most from a more detailed evaluation and possible energy efficiency upgrades without intensive data collection.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Standardizing Performance Metrics for Building-Level Electrical Distribution Systems

Building-level electrical distribution systems comprise a myriad of current-carrying equipment, conversion devices, and protection devices that deliver power from the utility or local distributed energy resources to end-use building loads. Electric power has traditionally been generated, transmitted, and distributed in alternating current (AC). However, the last decade has seen a significant increase in the integration of native direct current (DC) equipment that has elevated the importance of DC distribution systems. Numerous studies have comparatively examined the performance of various electrical distribution systems in buildings but have failed to achieve uniform conclusions, primarily because of a lack of consistent and analogous performance evaluation methods. This paper aims to fill this gap by providing a standard set of metrics and measurement boundaries to consistently evaluate the performance of AC, DC, or hybrid AC/DC electrical distribution systems. The efficacy of the proposed approach is evaluated on a representative medium-sized commercial office building model with AC distribution and an equivalent hybrid AC/DC and DC distribution model, wherein the AC distribution model is concluded to be the most efficient. The simulation results show variation in computed metrics with different selected boundaries that verify the effectiveness of the proposed approach in ensuring consistent computation of the performance of building-level electrical distribution systems. This paper provides an initial set of guidelines for building energy system stakeholders to adopt appropriate solutions, thus leading to more efficient energy systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

A Toolbox Necessity: Finding Best Practices in High-Performance Homes with the Building America Solution Center

The U.S. Department of Energy’s Building America Solution Center is a free, easy-to-access web tool containing the latest building science research from the Building America program. This paper describes how the Solution Center is bringing best practices for high-performance homes to members of the building industry to help their businesses to gain an edge to help expand their markets. It includes a tour of the Solution Center’s newest features and updates. The Building America Solution Center provides full and simple access to a wealth of best practices based on building science and energy efficiency research generated by the Building America program, along with other resources to help builders specify features, train crews, complete quality installations, and sell houses. This paper supports the visual presentation with the same title. The paper will be submitted for inclusion in the ACEEE Summer Study 2018 proceedings. The poster will be presented at the ACEEE 2018 Summer Study conference.

.S. Department of Energy Building Technologies Pro↗

New Whole-House Solutions Case Study: Lancaster County Career and Technology Center Green Home 3 - Mount Joy, Pennsylvania

This case study describes a unique vocational program at Lancaster County Career Technology Center in Mount Joy, PA, where high school students are gaining hands-on construction experience in building high performance homes with help from Building America team, Home Innovation Research Labs. This collaboration resulted in the Green Home 3, the third in a series of high performance homes for Apprentice Green. As one of LCCTC’s key educational strategies for gaining practical experience, students are involved in building real houses that incorporate state-of-the-art energy efficiency and green technologies. With two homes already completed, the Green Home 3 achieved a 44% whole-house energy savings over the Building America New Construction B10 Benchmark, DOE Zero Energy Ready Home (formerly Challenge Home) certification, and National Green Building Standard Gold-level certification.

BUILDING AMERICA↗

Building and managing high performance, scalable, commodity mass storage systems

The NAS Systems Division has recently embarked on a significant new way of handling the mass storage problem. One of the basic goals of this new development are to build systems at very large capacity and high performance, yet have the advantages of commodity products. The central design philosophy is to build storage systems the way the Internet was built. Competitive, survivable, expandable, and wide open. The thrust of this paper is to describe the motivation for this effort, what we mean by commodity mass storage, what the implications are for a facility that performs such an action, and where we think it will lead.

Lekashman, John↗

OpenStudio System-level KPI Reporting Measure v1.0

This is a OpenStudio measure that calculates and reports the system-level key performance indicators (KPIs) for evaluating building energy performance at the system level. The systems are defined by the service it provides in commercial buildings, which include (1) lighting, (2) Miscellaneous Electric Loads (MELs), (3) Heating, Ventilation and Air Conditioning (HVAC), and (4) Service Water Heating (SWH).

Li, Han↗