Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Particle-in-cell modeling of electron beam generated plasma

Plasmas generated using energetic electron beams are well known for their low electron temperature (T e ) and plasma potential, which makes them attractive for atomic-precision plasma processing applications such as atomic layer etch and deposition. A 2-dimensional particle-in-cell model for an electron beam-generated plasma in argon confined by a constant applied magnetic field is described here in this article. Plasma production primarily occurs in the path of the beam electrons in the center of the chamber. The resulting plasma spreads out in the chamber through non-ambipolar diffusion with a short-circuiting effect allowing unequal electron and ion fluxes to different regions of the bounding conductive chamber walls. The cross-field transport of the electrons (and thus the steady-state characteristics of the plasma) are strongly impacted by the magnetic field. T e is anisotropic in the electron beam region, but low and isotropic away from the plasma production zone. The plasma density increases and the plasma becomes more confined near the region of production when the magnetic field strengthens. The magnetic field reduces both electron physical and energy transport perpendicular to the magnetic field. T e is uniform along the magnetic field lines and slowly decreases perpendicular to it. Electrons are less energetic in the sheath regions where the sheath electric field repels and confines the low-energy electrons from the bulk plasma. Even though electron and ion densities are similar in the bulk plasma due to quasi-neutrality, electron and ion fluxes on the grounded chamber walls are unequal at most locations. Electron confinement by the magnetic field weakens with increasing pressure, and the plasma spread out farther from the electron beam region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anticathode effect on electron kinetics in electron beam generated E × B plasma

Electron beam (e-beam) generated plasmas with applied crossed electric and magnetic (E x B) fields are promising for low damage processing of materials with applications to microelectronics and quantum information systems. In cylindrical e-beam E x B plasmas, radial confinement of electrons and ions is achieved by an axial magnetic field and radial electric field, respectively. To control the axial confinement of electrons, such e-beam generated plasma sources may incorporate a conducting boundary known as an anticathode, which is placed on the axially opposite side of the plasma from the cathode. In this work, it is shown that varying the anticathode voltage bias can control the degree to which the anticathode collects or repels incident electrons, allowing control of warm electron (electron energies in 10–30 eV range) and beam electron population confinement. It is suggested that the effect of the anticathode bias on the formation of these distinct electron populations is also associated with the transition between weak turbulence and strong Langmuir turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First neutral beam experiments on Wendelstein 7-X

In the previous divertor campaign, the Wendelstein 7-X (W7-X) device injected 3.6 MW of neutral beam heating power allowing for the achievement of densities approaching 2 × 10 20 m -3 , and providing the first initial assessment of fast ion confinement in a drift optimized stellarator. The neutral beam injection (NBI) system on W7-X is comprised of two beam boxes with space for four radio frequency sources each. The 3.6 MW of heating reported in this work was achieved with two sources in the NI21 beam box. The effect of combined electron-cyclotron resonance heating (ECRH) and NBI was explored through a series of discharges varying both NBI and ECRH power. Discharges without ECRH saw a linear increase in the line-integrated plasma density, and strong peaking of the core density, over the discharge duration. The presence of 1 MW of ECRH power was found to be sufficient to control a continuous density rise during NBI operation. Simulations of fast ion wall loads were found to be consistent with experimental infrared camera images during operation. In general, NBI discharges were free from the presence of fast ion induced Alfvénic activity, consistent with low beam betas. These experiments provide data for future scenario development and initial assessment of fast-ion confinement in W7-X, a key topic of the project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutral beam prompt loss in LTX-β

Prompt loss of beam injected fast ions approaches 100% in lithium tokamak experiment-beta (LTX-β) discharges, though significantly improved confinement is expected for the higher current plasmas made available by a recent upgrade to the Ohmic heating power supply. Modeling of fast ions using TRANSP/NUBEAM finds a maximum coupled beam fraction of 76% at the near-term limits of the LTX-β operating space. The full ion orbit code POET is employed to validate NUBEAM results against possible non-adiabatic effects on fast ion orbits, but corrections to the prompt loss fraction due to collisionless transport are found to be small. The graphical method code CONBEAM is used to investigate the topology of fast ion phase space as it relates to neutral beam deposition, and counter-injected NBI is considered as a way to access a region of high field side beam deposition. A metric is developed within the CONBEAM using a beam filament model to estimate the prompt loss fraction and shown to agree well with both POET and NUBEAM, enabling near real-time analysis and potential feedback to operators between plasma discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interplay between beam-driven chirping modes and plasma confinement transitions in spherical tokamak ST40

Experiments on the high field spherical tokamak ST40 have led to the recent observation of interplay between beam-driven modes of sweeping frequency (chirping modes) and transitions to the enhanced global confinement regime (H-mode) and back to the low confinement regime (L-mode). The H-modes of plasma confinement are identified from decreased intensity of D α signal and from clear distinctions in the edge gradients of the visible plasma boundary (observed as a sharp plasma edge in camera images). The beam-driven chirping modes, identified as ideal magnetohydrodynamics beta-induced Alfvén acoustic eigenmodes modes, are observed in Mirnov coil signals, interferometry, and soft x-ray diagnostics. A moderate amplitude ‘primer’ chirping mode usually precedes an H–L transition. This is followed by a ‘dominant’ chirping mode with higher amplitude during the L-mode. The L–H transition back to the improved confinement occurs on a longer time scale of tens of ms, consistent with the slowing down time scale of fast beam ions. A dramatic decrease in toroidal plasma rotation is systematically observed associated with chirping modes sweeping down to zero frequency. Resonance maps built for the beam-driven chirping modes with the ASCOT (accelerated simulation of charged particle orbits in torodoial devices) code show that the resonant beam ions have orbits near the trapped-passing boundary. The ASCOT modelling assesses how losses of the resonant fast ions caused by the chirping modes with high enough amplitude modify the torque, potentially affecting the plasma rotation.

magnetic confinement fusion↗

Machine learning surrogate for charged particle beam dynamics with space charge based on a recurrent neural network with aleatoric uncertainty

In this work, we develop a machine learning (ML) model with aleatoric uncertainty for the low energy beam transport (LEBT) region of the LANSCE linear accelerator in which we model the transport of a space-charge-dominated 750 keV proton beam through a lattice of 22 quadrupole magnets. Our ML model is developed based on data generated by a Kapchinsky–Vladimirsky (KV) envelope model of beam transport. We show that a recurrent neural network can be used as a dynamical surrogate model for fast prediction of the LEBT beam envelope. Furthermore, we endow the model with the prediction of aleatoric uncertainty and compare three different approaches. We demonstrate that the ML-based uncertainty quantification models are well calibrated and produce good estimates of the regions where the model is less certain about its predictions. This ML framework is a necessary step in the development of a real-time virtual diagnostic tool with uncertainty quantification that can be integrated into more complex downstream tasks (e.g., adaptive control or learning flexible control policies via reinforcement learning) for improved efficiency in beam operations. In future work, we plan to expand on this preliminary study by considering more realistic envelope models that include longitudinal momentum spread and dispersive effects in bending magnets, as well as particle tracking codes with 3D space charge (such as and ). Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

The Continuous Electron Beam Accelerator Facility at 12 GeV

This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of 20 MV / m . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Aqueous harvesting of 88 Zr at a radioactive-ion-beam facility for cross-section measurements

Isotope harvesting is a method of collecting the long-lived radioisotopes that build up during the operation of ion-beam facilities in a way that is useful for subsequent research. As a demonstration of this method for the collection of a group IV metal at a fragmentation facility, the high-energy Zr 88 secondary beam produced from a 140-MeV/u Mo 92 primary beam at the National Superconducting Cyclotron Laboratory (NSCL) was stopped in a water target. The setup aimed to mimic the aqueous beam dump that will be implemented at the Facility for Rare Isotope Beams (FRIB). The collected Zr 88 and accompanying Y 88 decay daughter were radiochemically extracted from the solution and made into target samples suitable for neutron-capture cross-section measurements. These samples were then irradiated at two reactor facilities, and the Zr 88 average thermal-neutron-capture cross section ( σ T ) and resonance integral ( I ) were determined to be σ T = ( 8.04 ± 0.63 ) × 10 5 b and I = ( 2.53 ± 0.28 ) × 10 6 b. The σ T value agrees well with previous results and I , determined for the first time here, was found to be the largest measured resonance integral by two orders of magnitude. The Y 88 thermal-neutron-capture cross section was determined to be less than 1.8 × 10 4 b. This work demonstrates the steps needed to make cross-section measurements with samples produced via aqueous isotope harvesting.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Ion energy distribution in an electron beam ion trap inferred from simulations of the trapped ion cloud

For this work, we have inferred the energy distribution of trapped ions in an electron beam ion trap (EBIT) from simulations of the spatial distribution of Fe 13+ ions and a comparison with measured visible light images of the ion cloud. We simulated the cloud of Fe 13+ ions by computing ion trajectories in the EBIT for different ion energy distributions used to initialize the trajectories. We then performed a least-squares fit to infer the ion energy distribution that best reproduced the measured ion cloud. These best-fit distributions were typically non-Maxwellian. For electron beam energies of 395–475 eV and electron beam currents of 1–9 mA, we find that the average ion energy is in the range of 10–300 eV. We also find that the average ion energy increases with increasing beam current approximately as $\langle$E$\rangle$ ≈ 25 I e eV, where I e is the electron beam current in mA. We have also compared our results to Maxwell-Boltzmann-distribution ion clouds. We find that our best-fit non-thermal distributions have an $\langle$E$\rangle$ that is less than half that of the T from the best-fit Maxwell-Boltzmann distributions ($\langle$E$\rangle$/q)/T=0.41 ± 0.05.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of electron source feedback for enhanced X-ray beam stability at NSLS-II

Future synchrotron light sources are being designed to deliver significantly higher brightness and coherence, enabling faster scanning and more advanced imaging techniques. However, realizing these capabilities requires improved X-ray beam stability, as vibrations directly limit measurement accuracy and image quality. At the NSLS-II Hard X-ray Nanoprobe (HXN), a local mechanical feedback system mitigates low-frequency motion but provides only limited suppression of dominant vibrations at 27 Hz and 120 Hz. To address this limitation, this work explores the use of the electron beam itself as the actuator for feedback by integrating X-ray beam position monitor signals into the fast orbit feedback system through a dedicated electrometer. Experimental results show that this approach effectively suppresses the dominant vibration peaks and enhances stability at the focusing point. Benchmark ptychography measurements further confirm that electron-beam-based feedback reduces background fluctuations and mitigates vibration-induced artifacts under fast-scanning conditions. These results establish the feasibility of using the electron beam as a feedback actuator for next-generation synchrotron applications and provide an experimental assessment of its potential and limitations.

36 MATERIALS SCIENCE↗

Using kernel-based statistical distance to study the dynamics of charged particle beams in particle-based simulation codes

Measures of discrepancy between probability distributions (statistical distance) are widely used in the fields of artificial intelligence and machine learning. We describe how certain measures of statistical distance can be implemented as numerical diagnostics for simulations involving charged-particle beams. Related measures of statistical dependence are also described. The resulting diagnostics provide sensitive measures of dynamical processes important for beams in nonlinear or high-intensity systems, which are otherwise difficult to characterize. Here, the focus is on kernel-based methods such as maximum mean discrepancy, which have a well-developed mathematical foundation and reasonable computational complexity. Several benchmark problems and examples involving intense beams are discussed. While the focus is on charged-particle beams, these methods may also be applied to other many-body systems such as plasmas or gravitational systems.

47 OTHER INSTRUMENTATION↗

Phase Space Reconstruction from Accelerator Beam Measurements Using Neural Networks and Differentiable Simulations

Characterizing the phase space distribution of particle beams in accelerators is a central part of accelerator understanding and performance optimization. However, conventional reconstruction-based techniques either use simplifying assumptions or require specialized diagnostics to infer high-dimensional (> $2D$) beam properties. In this Letter, we introduce a general-purpose algorithm that combines neural networks with differentiable particle tracking to efficiently reconstruct high-dimensional phase space distributions without using specialized beam diagnostics or beam manipulations. Furthermore, we demonstrate that our algorithm accurately reconstructs detailed 4D phase space distributions with corresponding confidence intervals in both simulation and experiment using a single focusing quadrupole and diagnostic screen. This technique allows for the measurement of multiple correlated phase spaces simultaneously, which will enable simplified 6D phase space distribution reconstructions in the future.

47 OTHER INSTRUMENTATION↗

Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

Investigating the FLASH Effect in a Rat Brain Organotypic Model With a Novel High-Energy Electron Beam

Ultrahigh dose rate (FLASH) radiation therapy is reported to reduce normal tissue toxicity while maintaining tumor control; however, mechanism(s) remain obscure. To study FLASH mechanisms in brain tissue, we developed a novel experimental platform featuring a specialized high-energy electron linear accelerator, High Intensity Gamma Ray Source (HIGS), paired with an organotypic ex vivo brain metastasis model. We varied interpulse spacing to modulate the mean dose rate (MDR) of our unique 35 MeV electron beam, while maintaining extremely high instantaneous dose rate (IDR). We characterized dosimetry and targeting accuracy of the FLASH beam with film dosimetry. We combined this FLASH beam with an organotypic rat brain slice/breast carcinoma coculture model of brain metastasis to assess effects on normal and neoplastic tissues. Live-cell and bioluminescence imaging demonstrated cancer cell growth effects, whereas normal tissue responses and immune activation were assessed using live-cell imaging, cytokine profiles, and confocal microscopy. Here, we performed comparison experiments with 20 MeV electrons from a Varian clinical linear accelerator (VCLA) using conventional dose rates. The highest IDR of the FLASH beam to date was 20.7 ± 0.6 MGy/s, with maximum MDR of 20.7 MGy/s delivered in 1 pulse of 1 µs duration. Beam targeting was accurate to <1 mm and reproducible. HIGS-FLASH and VCLA dose rates equivalently decreased cancer cell growth. HIGS-FLASH irradiation significantly increased tumor necrosis factor α and fractalkine levels and confocal microscopy revealed distinct changes in microglial morphology slices suggesting microglia activation. Our novel experimental platform produces extremely high dose rates and rapid normal/neoplastic tissue readouts for mechanistic research into the effects of FLASH radiation in the brain. HIGS-FLASH irradiation induces comparable cancer cell growth inhibition but differential effects on cytokines and microglial morphology, suggesting that acute innate immune responses may be involved in FLASH normal tissue effects in the brain.

Kay, Tyler V. [Duke University, Durham, NC (United↗

Experimental study of the 34 m Cl beam production at intermediate energies

Here the isomeric content of a 34 Cl beam produced in the intermediate-energy projectile fragmentation of a 150 MeV/u 36 Ar beam on a 3 mm-thick Be target was studied. β-delayed γ-ray spectroscopy was used to measure the population of 34 Cl fragments in the ground vs. isomeric states at zero degrees relative to the incoming primary beam for four different momentum settings of the fragment separator near the predicted central velocity of these fragments, as well as, at two non-zero-degree settings for one momentum setting. Of the settings explored, which excluded rigidities within 0.5% of the value predicted to maximize total 34 Cl yield due to unreacted primary beam, the maximum rate for the production of Cl was found at a rigidity setting 0.75% below the predicted peak 34 Cl yield. The maximum population of the isomeric state relative to the ground state was observed at a rigidity 1.25% below the predicted maximum 34 Cl yield. Studies such as this are important in generating the understanding needed for producing isomer-enriched rare-isotope beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and alignment of a resonant cavity beam position monitor for the Compact LInear Collider (CLIC) project at CERN

Beam diagnostic devices are essential tools to sense the properties of the beam in particle accelerators. Beam Position Monitors (BPMs) are used to detect the transverse beam spatial coordinates. A large number of high-resolution resonant cavity BPMs, operating at 14GHz, are proposed to monitor the orbit of the two main beam linacs of the CLIC project. This paper discusses innovative calibration techniques on a dedicated test bench in the frame of the PACMAN project. The particular location of the electromagnetic center of the resonant cavity BPM is detected utilizing a stretched-wire measurement approach. Measurements, RF characterization and final fiducialization of the BPM electrical offset are treated with details. Initial studies through EM simulations of the cavity BPM are covered. The presented experimental results prove the feasibility of the alignment methodology with nanometric resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dedicated beam position monitor pair for model-independent lattice characterization at NSLS-II

This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with bunch-by-bunch (B$\times$B) resolution, were recently installed in a section of the storage ring free of magnetic fields. The new BPM pair measured the beam, or bunch’s transverse Poincaré map precisely after the beam was excited. Linear one-turn-matrices (OTM) were then derived, and from these, the 4-dimensional coupled Twiss parameters were extracted at the locations of the BPM pair. By normalizing beam oscillation amplitudes with the Twiss parameters, the global action-variables were obtained. Additionally, these action-variables facilitated the measurement of the local Twiss parameters observed by other BPMs independent on lattice model. This method is general, and particularly useful in certain scenarios such as a round beam mode in a diffraction-limited light source ring. We applied it to assess both weakly and strongly coupled lattices at the NSLS-II ring. Through analysis of the strongly coupled lattice, the quadrupole tilt errors were estimated to be less than 400 μrad. Utilizing the BPMs’ B$\times$B resolution, for the first time we observed the variations of the linear lattice along a long bunch-train.

36 MATERIALS SCIENCE↗

Mitigating Damage to Hybrid Perovskites Using Pulsed-Beam TEM

Using a pulsed-beam transmission electron microscope, we discover a reduction in damage to methylammonium lead iodide (MAPbI3) as compared to conventional beams delivered at the same dose rates. For rates as low as 0.001 e·Å –2 ·s –1 , we find up to a 17% reduction in damage at a total dose of 10 e·Å –2 . We systematically study the effects of number of electrons in each pulse and the duration between pulse arrival. Damage increases for both, though the number of electrons per pulse has a larger effect. A crossover is identified, where a pulsed beam causes more damage than a conventional one. Although qualitatively similar to previous findings, the degree to which damage is reduced in MAPbI3 is less than that observed for other materials (e.g., C36H74), supporting the hypothesis that the effects are material- and damage-mechanism-dependent. Despite this, the observation here of damage reduction for relatively large electron packets (up to 200 electrons per pulse) suggests that MAPbI3 is in fact less susceptible to irradiation than C36H74, which may be related to reported self-healing effects. This work provides insights into damage processes and durability in hybrid perovskites and also illustrates the viability of using pulsed-beam TEM to explore the associated molecular-level routes to degradation, analogous to laser-accelerated energetic pulsed electron beams and the study of damage to biomolecules, cells, and tissues in radiobiology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗