Use of a continuous source in flame fluorescence spectrometry.
Continuous source for atomic fluorescence flame spectrometry using 150-watt xenon arc, total consumption atomizer-burner and low resolution monochromator
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Continuous source for atomic fluorescence flame spectrometry using 150-watt xenon arc, total consumption atomizer-burner and low resolution monochromator
Photoelectric spectral scans at 30-A resolution of 9 dwarfs, 10 giants and 6 supergiants with spectral types GO to M5 were presented. All stars were observed every 4 A from wavelength 3300 to wavelength 7000. Absorption features at this resolution coincide with: strong atomic lines of Fe 1,11, Ca 1,11, Mg 1, and Na 1; vibrational bands of the electronic transitions of TiO, MgH, CaH, SiH, AlH, Cn, Ch, C2, OH, and NH. The dependence of the wavelength 3740 Fe 1 blend and the wavelength 3440 depression on temperature is discussed.
Photoelectric spectral scans at 30 A resolution of nine dwarfs, ten giants, and six supergiants with spectral types G0 to M5 are presented. (All stars were observed every 4 A from 3300 to 7000 A.) Absorption features observed at this resolution coincide with: strong atomic lines of Fe I, Fe II, Ca I, Ca II, Mg I, and Na I; vibrational bands of the electronic transitions of TiO, MgH, CaH, SiH, AlH, CN, CH, C2, OH, and NH. The dependences of the 3740-A Fe I blend and the 3440-A depression on temperature are discussed.
Eighteen-pound unit gives real-time onsite sample analysis. Mass range is twelve to two hundred atomic mass units with resolution of two hundred. Device has biomedical application possibilities, such as determination of alcohol and gas content of blood and breath.
The Infrared Spectrograph on the Spitzer Space Telescope was used for observations of the Kepler supernova remnant, with all four instrument modules targeted on the bright infrared knot located at 17h30m35.80s,-21d28m54.0s (J2000). The low spectral resolution modules data show a dust continuum spectrum consistent with dust grains heated by high-energy electrons, while the high resolution modules data show atomic emission line ratios consistent with excitation by a high velocity shock of greater than 100 kilometers per second and electron densities of approximately 1,000 per centimeter. The abundance ratios for the six detected elements show signs of heavy-element enhancement. This work is based on observations made with the Spitzer Space Telescope, which is operated by the Jet Propulsion Laboratory, California Institute of Technology. Support for this work was provided by NASA's Office of Space Science.
The recent discovery of Pb* (radiogenic lead) -enriched domains (PEDs) in zircon using high-resolution scanning ion imaging, atom probe tomography and transmission electron microscopy indicates that the U-Pb isotopic system in zircon can be affected not only by Pb* loss but also by intra-crystalline Pb* enrichment. However, the formation mechanism of PEDs and the consequences for in-situ U-Pb dating remain elusive. To further understand these issues, scanning ion imaging and U-Pb dating were carried out on 51 Hadean detrital zircon grains from the Jack Hills, Western Australia. Of these, 8 grains were found to contain micrometer-scale PEDs with elevated Pb-207 and Pb-206 in the ion images. Isotope profiles across these PEDs confirm that they represent unsupported Pb* resulting from intra-grain mobilization and local enrichment of Pb* during ancient overprinting events. The PEDs are rare in most grains, with only 1 – 3 Pb* hotspots present in any ~70 μm × 70 μm imaged area, and are located either in dark-CL, high-U growth zones, or associated with bright-CL, low-Th recrystallized domains, suggesting that they were likely formed by local-scale processes. The PEDs located in dark-CL, high-U growth zones likely resulted from Pb* trapped in local, interconnected pathways produced by radiation damage during thermal overprinting events. Those associated with bright-CL, low-Th domains are interpreted as Pb* concentrated in nanoscale pores formed during fluid-present recrystallization of non-metamict zircon. Our interpretations therefore imply that intra-crystalline enrichment of Pb* in zircon can occur at various scales and through diverse mechanisms. Age calculations based on the ion images demonstrate that incorporation of PEDs in conventional in-situ SIMS spots produces spuriously old ages that are either reversely discordant or concordant, depending on the time of Pb* mobilization and the analytical precision. The implication is that careful investigation of intra-grain distribution of U-Th-Pb isotopes is required in order to better understand the U-Pb isotopic system and to obtain reliable crystallization ages for ancient zircons affected by complex Pb* mobilization and redistribution.
This work reports on the application of a novel electric field-ionization setup for high-resolution laser spectroscopy measurements on bunched fast atomic beams in a collinear geometry. In combination with multi-step resonant excitation to Rydberg states using pulsed lasers, the field ionization technique demonstrates increased sensitivity for isotope separation and measurement of atomic parameters over previous non-resonant laser ionization methods. The setup was tested at the Collinear Resonance Ionization Spectroscopy experiment at ISOLDE-CERN to perform high-resolution measurements of transitions in the indium atom from the 5s 2 5d 2 D 5/2 and 5s 2 5d 2 D 3/2 states to 5s 2 np 2 P and 5s 2 nf 2 F Rydberg states, up to a principal quantum number of n=72 . The extracted Rydberg level energies were used to re-evaluate the ionization potential of the indium atom to be 46,670.107(4)cm -1 . The nuclear magnetic dipole and nuclear electric quadrupole hyperfine structure constants and level isotope shifts of the 5s 2 5d 2 D 5/2 and 5s 2 5d 2 D 3/2 states were determined for 113,115 In. The results are compared to calculations using relativistic coupled-cluster theory. A good agreement is found with the ionization potential and isotope shifts, while disagreement of hyperfine structure constants indicates an increased importance of electron correlations in these excited atomic states. With the aim of further increasing the detection sensitivity for measurements on exotic isotopes, a systematic study of the field-ionization arrangement implemented in the work was performed at the same time and an improved design was simulated and is presented. The improved design offers increased background suppression independent of the distance from field ionization to ion detection.
Cool red giant stars exhibit absorption bands of calcium monochloride (CaCl) in the optical region. In this work, the bands of CaCl corresponding to the A 2 Π − X 2 Σ + transition with v' ≤ 4 and v'' ≤ 4, and B 2 Σ + − X 2 Σ + transition with v' ≤ 2 and v'' ≤ 2 are rotationally analyzed with PGOPHER, a multipurpose program for simulating and fitting molecular spectra. All bands were analyzed using high-resolution absorption spectra collected at the National Solar Observatory in 1985, calibrated with atomic lines from a high-resolution emission spectrum obtained in a separate hollow cathode experiment. The results are compared with previous laser-induced fluorescence measurements. Overall, the accuracy of spectroscopic constants for the A2Π and B2Σ+ states is improved. Scaled transition dipole moment calculations were used to obtain line strengths. Line lists are provided with Einstein A coefficients and oscillator strengths, which can be used to determine CaCl stellar abundances. Additionally, isotope splittings allowed us to estimate band origins for the 40 Ca 37 Cl isotopologue based on band-head positions.
Rationale Nd and Sm isotope ratios play an important role in geological dating and as nuclear forensic signatures; however, the overlap of the respective 144, 148, 150 Nd/Sm isobars requires prior separations to be performed before analysis on typical MS platforms. The work presented here overcomes these isobaric interferences using ultrahigh‐mass resolution to alleviate interference without prior chemical separations. Methods A liquid sampling‐atmospheric pressure glow discharge ion source was coupled to a standard, QExactive Focus Orbitrap mass spectrometer, providing a mass resolution of ~80 k. A Spectroswiss FTMS booster X2 data acquisition package was used to collect extended transients, providing much higher mass resolution; ~230 k and ~600 k are employed here for Nd and Sm isotopes. Results While the standard Orbitrap resolution is far greater than typical “atomic” MS platforms, it was insufficient to alleviate all isobars. The use of a resolution of ~230 k resulted in baseline separation across the entire isotopic envelope for both Nd and Sm. Isotope ratios obtained from Nd:Sm mixtures using high‐resolution were equivalent to those found for individual‐element solutions, while isotope ratios obtained at a resolution of ~80 k (standard for the OEM data system) showed large deviations. Conclusions Use of ultrahigh‐resolution is an attractive alternative to extensive chemical separations to alleviate severe isobaric interferences. Sufficient mass resolution greatly reduces/eliminates the need for sample manipulations (separations) before analysis while reducing costs and total analysis times.
Abstract Modern scanning microscopes can image materials with up to sub-atomic spatial and sub-picosecond time resolutions, but these capabilities come with large volumes of data, which can be difficult to store and analyze. We report the Fast Autonomous Scanning Toolkit (FAST) that addresses this challenge by combining a neural network, route optimization, and efficient hardware controls to enable a self-driving experiment that actively identifies and measures a sparse but representative data subset in lieu of the full dataset. FAST requires no prior information about the sample, is computationally efficient, and uses generic hardware controls with minimal experiment-specific wrapping. We test FAST in simulations and a dark-field X-ray microscopy experiment of a WSe 2 film. Our studies show that a FAST scan of <25% is sufficient to accurately image and analyze the sample. FAST is easy to adapt for any scanning microscope; its broad adoption will empower general multi-level studies of materials evolution with respect to time, temperature, or other parameters.
Analyzing hydrogen distribution in nuclear structural materials at sub-nanometer scale spatial resolution has been challenging by electron microscopy. Furthermore, methods such as thermal desorption spectroscopy only provides a bulk estimate of hydrogen concentration with no nanoscale spatial resolution. In the last decade, cryogenic transfer atom probe tomography (APT) has been emerging as an invaluable characterization technique for analyzing the nanoscale distribution of hydrogen isotopes in materials.
Atomic layer deposition (ALD) allows for fine control over the thickness, stoichiometry, and structural defects of materials. ALD provides a suitable route to deposit lead halides, which can further be converted to perovskites for photovoltaics, photoemission, and photodetection, among other applications. Deposition of lead halides by ALD has already begun to be explored; however, the precursors used in published processes are highly hazardous, require expensive fabrication processes, or contain impurities that can jeopardize the optoelectronic properties of metal halide perovskites after conversion. In this work, we deposited lead iodide (PbI 2 ) by a facile ALD process involving only two readily accessible and low-cost precursors. PbI 2 nanocrystals were grown on soda-lime glass (SLG), silicon dioxide support grids, and silicon wafer substrates and provided the groundwork for further investigation into developing lead halide perovskite processes by ALD. Further, the ALD-grown PbI 2 was characterized by annular dark-field scanning transmission electron microscopy (ADF-STEM), atomic force microscopy (AFM), high resolution transmission electron microscopy (HRTEM), X-ray fluorescence (XRF), and X-ray photoemission spectroscopy (XPS), among other methods. This work presents the first step to synthesize lead halide perovskites with atomic control for applications such as interfacial layers in photovoltaics and for deposition in microcavities for lasing.
Here, we demonstrate a new approach for fast preparation, manipulation, and collective readout of an atomic Rydberg-state qubit. By making use of Rydberg blockade inside a small atomic ensemble, we prepare a single qubit within 3 μs with a success probability of $F_p$ = 0.93 ± 0.02, rotate it, and read out its state in 6 μs with a single-shot fidelity of $F_d$ = 0.92 ± 0.04. The ensemble-assisted detection is 10 3 times faster than imaging of a single atom with the same optical resolution, and enables fast repeated nondestructive measurement. We observe qubit coherence times of 15 μs, much longer than the π rotation time of 90 ns. Potential applications ranging from faster quantum information processing in atom arrays to efficient implementation of quantum error correction are discussed.
The chemical composition of the interstellar medium and planetary atmospheres is constantly in flux as atoms and molecules collide and interact with high-energy particles such as electrons, protons, and photons. These transformative processes ultimately lead to the coalescence of molecules and eventually the birth of stars. Our understanding of these chemical ecosystems relies on models that synthesize data from gas-phase experiments, providing insights into reaction cross sections. This Review examines efforts to delve into the fundamental bond-forming and bond-breaking dynamics that occur during bimolecular and electron-initiated reactions. Furthermore, these experiments involve clever approaches to establish a time reference and the collision geometry necessary for tracking atomic motion with femtosecond time resolution. Findings from these efforts enhance present models and improve predictions for molecule-molecule and electron-molecule collisions.
This is the final report for the DOE-AMO DE-FG02-05ER15663 grant. Using a high-peak-power laser system at the Extreme Light Laboratory of the University of Nebraska-Lincoln, we develop novel femtosecond radiation sources and use them to investigate ultrafast photo-induced processes. Pulses of high energy electrons and x-rays are generated when an optical pulse is focused to ultra-high intensity. The radiation is used to probe the evolution of matter under highly non-equilibrium conditions with atomic-scale temporal and spatial resolution. Moreover, the facility is small enough to fit in a university laboratory and is operated by graduate students and postdocs.
The abundance of atomic oxygen is a major unknown for the Mars upper atmosphere, and systematic measurements of this key species is a primary objective of NASA’s Mars Atmosphere and Volatile Evolution (MAVEN) mission. Moreover, the Martian dayside temperature structure and its variability has been a subject of considerable debate in the past. In this study, an inversion analysis of the periapsis limb scans of the O i 130.4 nm emission observed by MAVEN is performed to quantify the neutral temperature and atomic oxygen abundance in the Mars upper atmosphere. Our analysis yields unprecedented resolution of the spatial variation of Mars atomic oxygen, showing that its exobase density decreases with the solar zenith angle (SZA) from ∼0° to 60° by about an order of magnitude, from ∼10{sup 8} to ∼10{sup 7} cm{sup −3} near perihelion (2015 April) and from ∼10{sup 7} to ∼10{sup 6} cm{sup −3} near aphelion (2017 November). For a given SZA the exobase densities near perihelion are about an order of magnitude higher than those near aphelion. The [O]/[CO{sub 2}] mixing ratio at 130 km altitude can vary from ∼0.1% to 4.6%, which also decreases with increasing SZA. Moreover, it is shown that the Mars exobase temperature does not vary significantly with SZA from ∼0° to ∼60°, which is estimated to be ∼239.2 ± 27.6 K near perihelion and ∼162.4 ± 19.9 K near aphelion, with a difference of 76.8 K between these two seasonal extremes.
Electron Paramagnetic Resonance (EPR) is a powerful technique to study materials and biological samples on an atomic scale. High-field EPR in particular enables extracting very small g-anisotropies in organic radicals and half-filled 3d and 4f metal ions such as Mn II (3d 5 ) or Gd III (4f 7 ), and resolving EPR signals from unpaired spins with very close g-values, both of which provide high-resolution details of the local atomic environment. Before the recent commissioning of the high-homogeneity Series Connected Hybrid magnet (SCH, superconducting + resistive) at the National High Magnetic Field Laboratory (NHMFL), the highest-field, high-resolution EPR spectrometer available was limited to 25 T using a purely resistive “Keck” magnet at the NHMFL. Herein, we report the first EPR experiments performed using the SCH magnet capable of reaching the field of 36 T, corresponding to an EPR frequency of 1 THz for g = 2. The magnet’s intrinsic homogeneity (25 ppm, that is 0.9 mT at 36 T over 1 cm diameter, 1 cm length cylinder) was previously established by NMR. We characterized the magnet’s temporal stability (5 ppm, which is 0.2 mT at 36 T over one-minute, the typical acquisition time) using 2,2-diphenyl-1-picrylhydrazyl (DPPH). This high resolution enables resolving the weak g-anisotropy of 1,3-bis(diphenylene)-2-phenylallyl (BDPA), Δg = 2.5 × 10 –4 obtained from measurements at 932 GHz and 33 T. Subsequently, we recorded EPR spectra at multiple frequencies for two Gd III complexes with potential applications as spin labels. In conclusion, we demonstrated a significant reduction in line broadening in Gd[DTPA], attributed to second order zero field splitting, and a resolution enhancement of g-tensor anisotropy for Gd[sTPATCN]-SL.
Magnetic force microscopy (MFM) enables mapping local magnetic fields across a sample surface with nanoscale resolution. To perform MFM, an atomic force microscopy (AFM) probe whose tip has been magnetized vertically (i.e., perpendicular to the probe cantilever) is oscillated at a fixed height above the sample surface. The resultant shifts in the oscillation phase or frequency, which are proportional to the magnitude and sign of the vertical magnetic force gradient at each pixel location, are then tracked and mapped. Although the spatial resolution and sensitivity of the technique increases with decreasing lift height above the surface, this seemingly straightforward path to improved MFM images is complicated by considerations such as minimizing topographical artifacts due to shorter range van der Waals forces, increasing the oscillation amplitude to further improve sensitivity, and the presence of surface contaminants (in particular water due to humidity under ambient conditions). In addition, due to the orientation of the probe's magnetic dipole moment, MFM is intrinsically more sensitive to samples with an out-of-plane magnetization vector. Here, high-resolution topographical and magnetic phase images of single and bicomponent nanomagnet artificial spin-ice (ASI) arrays obtained in an inert (argon) atmosphere glovebox with <0.1 ppm O 2 and H 2 O are reported. Further, optimization of lift height and drive amplitude for high resolution and sensitivity while simultaneously avoiding the introduction of topographical artifacts is discussed, and detection of the stray magnetic fields emanating from either end of the nanoscale bar magnets (~250 nm long and <100 nm wide) aligned in the plane of the ASI sample surface is shown. Likewise, using the example of a Ni-Mn-Ga magnetic shape memory alloy (MSMA), MFM is demonstrated in an inert atmosphere with magnetic phase sensitivity capable of resolving a series of adjacent magnetic domains each ~200 nm wide.