Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Origin of Magic Angles in Twisted Bilayer Graphene

Twisted bilayer graphene (TBG) was recently shown to host superconductivity when tuned to special “magic angles” at which isolated and relatively flat bands appear. However, until now the origin of the magic angles and their irregular pattern have remained a mystery. Here we report on a fundamental continuum model for TBG which features not just the vanishing of the Fermi velocity, but also the perfect flattening of the entire lowest band. When parametrized in terms of α ~ 1/θ, the magic angles recur with a remarkable periodicity of Δα ≃ 3/2. We show analytically that the exactly flat band wave functions can be constructed from the doubly periodic functions composed of ratios of theta functions—reminiscent of quantum Hall wave functions on the torus. We further report on the unusual robustness of the experimentally relevant first magic angle, address its properties analytically, and discuss how lattice relaxation effects help justify our model parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Band Engineering of Large-Twist-Angle Graphene/h-BN Moiré Superlattices with Pressure

Graphene interfacing hexagonal boron nitride (h-BN) forms lateral moiré superlattices that host a wide range of new physical effects such as the creation of secondary Dirac points and band gap opening. A delicate control of the twist angle between the two layers is required as the effects weaken or disappear at large twist angles. In this Letter, we show that these effects can be reinstated in large-angle (~1.8°) graphene/h-BN moiré superlattices under high pressures. Additionally, a graphene/h-BN moiré superlattice microdevice is fabricated directly on the diamond culet of a diamond anvil cell, where pressure up to 8.3 GPa is applied. The band gap at the primary Dirac point is opened by 40-60 meV, and fingerprints of the second Dirac band gap are also observed in the valence band. Theoretical calculations confirm the band engineering with pressure in large-angle graphene/h-BN bilayers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Irena : tool suite for modeling and analysis of small-angle scattering.

Irena, a tool suite for analysis of both X-ray and neutron small-angle scattering (SAS) data within the commercial Igor Pro application, brings together a comprehensive suite of tools useful for investigations in materials science, physics, chemistry, polymer science and other fields. In addition to Guinier and Porod fits, the suite combines a variety of advanced SAS data evaluation tools for the modeling of size distribution in the dilute limit using maximum entropy and other methods, dilute limit small-angle scattering from multiple non-interacting populations of scatterers, the pair-distance distribution function, a unified fit, the Debye-Bueche model, the reflectivity (X-ray and neutron) using Parratt's formalism, and small-angle diffraction. There are also a number of support tools, such as a data import/export tool supporting a broad sampling of common data formats, a data modification tool, a presentation-quality graphics tool optimized for small-angle scattering data, and a neutron and X-ray scattering contrast calculator. These tools are brought together into one suite with consistent interfaces and functionality. The suite allows robust automated note recording and saving of parameters during export.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conditional Experts for Improved Building Damage Assessment Across Satellite Imagery View Angles

Rapid building damage assessment (BDA) is vital in guiding disaster response missions and estimating population distribution across impacted areas. While commercial satellite imagery providers have enabled near-daily monitoring of the Earth, near-realtime assessment of disaster scenarios frequently requires analysis of off-nadir imagery, as satellites are often far from impacted areas for at-nadir post-event imaging to occur Such scenarios are, however, underrepresented in existing BDA datasets and methodologies. With this motivation, we investigate generalization capabilities of current BDA practices across overhead view-angles and strategies for their improvement. Using a labeled dataset of images capturing conflict-related damages, we first train a baseline BDA architecture using imbalanced and balanced datasets with respect to view-angle. Then, we explore conditional convolutions parameterized on image features, image nadir, and their combination as a mechanism for conditioning on view-angles. Experiments demonstrate the limitations of current practice and the potential of conditional mechanisms to increase model robustness to view-angle variations.

Ambrozio Dias, Philipe↗

Technique to measure contact angle of micro/nanodroplets using atomic force microscopy

Contact angle is the primary parameter that characterizes wetting; however, the measurement techniques have been limited to droplets with a diameter as low as about 50 {mu}m. The authors developed an atomic force microscopy-based technique to measure the contact angle of micro- and nanodroplets deposited using a modified nanoscale dispensing tip. The obtained contact angle results were compared with those of a macrodroplet (2.1 mm diameter). It was found that the contact angle on various surfaces decreases with decreasing the droplet size.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sputter deposition of Al-doped ZnO films with various incident angles

Al-doped ZnO (AZO) films were sputter deposited on glass substrates heated at 200 degree sign C under incident angles of sputtered particles at 0 degree sign (incidence normal to substrate), 20 deg., 40 deg., 60 deg., and 80 deg. In the case of normal incidence, x-ray diffraction pole figures show a strong [001] preferred orientation normal to the film surface. In contrast, in the case wherein the incident angles were higher than 60 degree sign , the [001] orientation inclined by 25 deg. - 35 deg. toward the direction of sputtered particles. Transmission electron microscopy revealed that the tilt angle of the [001] orientation increased with increasing angle of the incident sputtered particles, whereas the columnar structure did not show any sign of inclination with respect to the substrate plane.

36 MATERIALS SCIENCE↗

Impact of pellet preparation on reflectance measurements of ammonium sulfate by single-angle reflectance spectroscopy

The optical constants, n and k, are required to model the reflection, refraction and transmission of light at the first surface interface of a material, as well as its propagation through the material; here n corresponds to the real component and k the imaginary component of the refractive index. Several different spectroscopic methods have been used to determine the n and k values for different materials, including single angle reflectance spectroscopy and ellipsometry. The single-angle reflectance method quantitatively records the specular reflectance R(v) from a plane parallel face of the material and uses the Kramers-Kronig transform to extract the n and k values. For most compounds, however, it is difficult to obtain a single crystal or high-quality window of sufficient planarity and of the appropriate dimensions (several mm) to make the measurement. For this reason, we further investigate the use of pressed pellets of neat powdered substances to measure optical constants of these substances using the single-angle reflectance method. We have found that surface roughness can significantly influence the measured quantitative reflectance spectrum R(v) and, consequently, the derived n and k parameters. A collaborative study between Defence Research and Development Canada (DRDC) - Valcartier Research Center and Pacific Northwest National Laboratory (PNNL) has been carried out using different pellets of neat ammonium sulfate [(NH4)2SO4] to show how parameters such as the relative fraction of particle sizes for the component powder along with the grinding process of the pure compound all can affect the reflectance spectrum used to derive the optical constants. All pressed pellets were characterized by single-angle reflectance spectroscopy.

Diaz, Emmanuela↗

Collimator angle influence on dose distribution optimization for vertebral metastases using volumetric modulated arc therapy

Purpose: The cylindrical symmetry of vertebrae favors the use of volumetric modulated arc therapy in generating a dose ''hole'' on the center of the vertebrae limiting the dose to the spinal cord. The authors have evaluated if collimator angle is a significant parameter for dose distribution optimization in vertebral metastases. Methods: Three patients with one-three vertebrae involved were considered. Twenty-one differently optimized plans (nine single-arc and 12 double-arc plans) were performed, testing various collimator angle positions. Clinical target volume was defined as the whole vertebrae, excluding the spinal cord canal. The planning target volume (PTV) was defined as CTV+5 mm. Dose prescription was 5x4 Gy{sup 2} with normalization to PTV mean dose. The dose at 1 cm{sup 3} of spinal cord was limited to 11.5Gy. Results: The best plans in terms of target coverage and spinal cord sparing were achieved by two arcs and Arc1-80 deg. and Arc2-280 deg. collimator angles for all the cases considered (i.e., leaf travel parallel to the spinal cord primary orientation). If one arc is used, only 80 deg. reached the objectives. Conclusions: This study demonstrated the role of collimation rotation for the vertebrae metastasis irradiation, with the leaf travel parallel to the spinal cord primary orientation to be better than other solutions. Thus, optimal choice of collimator angle increases the optimization freedom to shape a desired dose distribution.

60 APPLIED LIFE SCIENCES↗

iCycle: Integrated, multicriterial beam angle, and profile optimization for generation of coplanar and noncoplanar IMRT plans

Purpose: To introduce iCycle, a novel algorithm for integrated, multicriterial optimization of beam angles, and intensity modulated radiotherapy (IMRT) profiles. Methods: A multicriterial plan optimization with iCycle is based on a prescription called wish-list, containing hard constraints and objectives with ascribed priorities. Priorities are ordinal parameters used for relative importance ranking of the objectives. The higher an objective priority is, the higher the probability that the corresponding objective will be met. Beam directions are selected from an input set of candidate directions. Input sets can be restricted, e.g., to allow only generation of coplanar plans, or to avoid collisions between patient/couch and the gantry in a noncoplanar setup. Obtaining clinically feasible calculation times was an important design criterium for development of iCycle. This could be realized by sequentially adding beams to the treatment plan in an iterative procedure. Each iteration loop starts with selection of the optimal direction to be added. Then, a Pareto-optimal IMRT plan is generated for the (fixed) beam setup that includes all so far selected directions, using a previously published algorithm for multicriterial optimization of fluence profiles for a fixed beam arrangement Breedveld et al.[Phys. Med. Biol. 54, 7199-7209 (2009)]. To select the next direction, each not yet selected candidate direction is temporarily added to the plan and an optimization problem, derived from the Lagrangian obtained from the just performed optimization for establishing the Pareto-optimal plan, is solved. For each patient, a single one-beam, two-beam, three-beam, etc. Pareto-optimal plan is generated until addition of beams does no longer result in significant plan quality improvement. Plan generation with iCycle is fully automated. Results: Performance and characteristics of iCycle are demonstrated by generating plans for a maxillary sinus case, a cervical cancer patient, and a liver patient treated with SBRT. Plans generated with beam angle optimization did better meet the clinical goals than equiangular or manually selected configurations. For the maxillary sinus and liver cases, significant improvements for noncoplanar setups were seen. The cervix case showed that also in IMRT with coplanar setups, beam angle optimization with iCycle may improve plan quality. Computation times for coplanar plans were around 1-2 h and for noncoplanar plans 4-7 h, depending on the number of beams and the complexity of the site. Conclusions: Integrated beam angle and profile optimization with iCycle may result in significant improvements in treatment plan quality. Due to automation, the plan generation workload is minimal. Clinical application has started.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing radiation dose to the female breast during CT coronary angiography: A simulation study comparing breast shielding, angular tube current modulation, reduced kV, and partial angle protocols using an unknown-location signal-detectability metric

Purpose: The authors compared the performance of five protocols intended to reduce dose to the breast during computed tomography (CT) coronary angiography scans using a model observer unknown-location signal-detectability metric.Methods: The authors simulated CT images of an anthropomorphic female thorax phantom for a 120 kV reference protocol and five “dose reduction” protocols intended to reduce dose to the breast: 120 kV partial angle (posteriorly centered), 120 kV tube-current modulated (TCM), 120 kV with shielded breasts, 80 kV, and 80 kV partial angle (posteriorly centered). Two image quality tasks were investigated: the detection and localization of 4-mm, 3.25 mg/ml and 1-mm, 6.0 mg/ml iodine contrast signals randomly located in the heart region. For each protocol, the authors plotted the signal detectability, as quantified by the area under the exponentially transformed free response characteristic curve estimator (A-caret{sub FE}), as well as noise and contrast-to-noise ratio (CNR) versus breast and lung dose. In addition, the authors quantified each protocol's dose performance as the percent difference in dose relative to the reference protocol achieved while maintaining equivalent A-caret{sub FE}.Results: For the 4-mm signal-size task, the 80 kV full scan and 80 kV partial angle protocols decreased dose to the breast (80.5% and 85.3%, respectively) and lung (80.5% and 76.7%, respectively) with A-caret{sub FE} = 0.96, but also resulted in an approximate three-fold increase in image noise. The 120 kV partial protocol reduced dose to the breast (17.6%) at the expense of increased lung dose (25.3%). The TCM algorithm decreased dose to the breast (6.0%) and lung (10.4%). Breast shielding increased breast dose (67.8%) and lung dose (103.4%). The 80 kV and 80 kV partial protocols demonstrated greater dose reductions for the 4-mm task than for the 1-mm task, and the shielded protocol showed a larger increase in dose for the 4-mm task than for the 1-mm task. In general, the CNR curves indicate a similar relative ranking of protocol performance as the corresponding A-caret{sub FE} curves, however, the CNR metric overestimated the performance of the shielded protocol for both tasks, leading to corresponding underestimates in the relative dose increases compared to those obtained when using the A-caret{sub FE} metric.Conclusions: The 80 kV and 80 kV partial angle protocols demonstrated the greatest reduction to breast and lung dose, however, the subsequent increase in image noise may be deemed clinically unacceptable. Tube output for these protocols can be adjusted to achieve a more desirable noise level with lesser breast dose savings. Breast shielding increased breast and lung dose when maintaining equivalent A-caret{sub FE}. The results demonstrated that comparisons of dose performance depend on both the image quality metric and the specific task, and that CNR may not be a reliable metric of signal detectability.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-382: Volumetric Modulated Arc Therapy (VMAT) Beam Angle Optimization in Pulsed Partial Brain Irradiation (PPBI) for Newly Diagnosed Glioblastoma

Purpose: To optimize VMAT beam parameters in PPBI to minimize treatment time. We investigate the coverage and organs at risk (OR) avoidance capability of shorter arcs with shorter treatment times. Methods: We evaluated the treatment plans for eleven previously treated PPBI patients. Each patient received 46Gy (2Gy×23) to the initial target and an additional 14Gy (2Gy×7) as a sequential boost. Each daily 2-Gy fraction was delivered as ten 0.2-Gy pulses separated by 3-minute intervals using VMAT. Each pulse was delivered using the same arc and covered at least 95% of the PTV with at least 95% of the prescription dose. To optimize the VMAT beam angle, an initial 360° full-arc VMAT plan was implemented. Beam control points and their corresponding dose rates were exported. A curve of the product of control point and dose rate was plotted against treatment beam angle. The optimum angle range was determined from this relationship. We chose the minimum continuous angle range that covered 85% of the area under the curve. Planning parameters, including treatment time for each pulse (T-pulse), PTV coverage, maximum dose (Dmax), homogeneity index (HI=D5/D95), R50 (50%IDL/PTV), and Dmax to ORs, were compared. Results: Mean PTV volume was 364.1±181.5cc. Mean T-pulse of partial-arc beams was 34.3±10.6s, vs. 63.0±1.7s (p<0.001) for that of full-arc beams. No significant differences were found for PTV V95, Dmax and R50, 99.4%±1.2% vs. 99.7%±0.5% (p=0.066), 108.0%±1.2% vs. 107.5%±1.1% (p=0.107), 2.95±0.38 vs. 2.87±0.35 (p=0.165), for the plans with partial-arc and full-arc beams, respectively. However, plans using full-arc do provide better PTV V100 and HI, 96.0%±3.0% vs. 97.2%±2.0% (p=0.025) and 1.06±0.03 vs. 1.04±0.01 (p=0.009). No significant difference was found on Dmax to ORs. Conclusion: PPBI with optimized partial-arc plans are clinically comparable to full-arc plans, while treatment time be significantly reduced, average saving of 287s for a 10-pulse treatment.

60 APPLIED LIFE SCIENCES↗

SU-F-T-414: Mathematical Formulation of Gantry Starting Angle for Right Medial Tangential Arc in Left Intact Partial Breast Irradiation Using Volumetric Modulated Arc Therapy (VMAT)

Purpose: To choose appropriate gantry starting angle for partial left breast irradiation using volumetric modulated arc therapy (VMAT). Methods: A random patient of left breast carcinoma was selected for this study. The slice which was selected for this mathematical formulation was having maximum breast thickness and maximum medial and lateral tangential distance. After this appropriate isocenter was chosen on that CT slice. The distances between various points were measured by the measuring tool in Monaco 5.00.04. Using the various trigonometric equations, a final equation was derived which shows the relationship between Gantry start angle, isocenter Location and tissue thickness. Results: The final equation for gantry start for right medial tangential arc is given asStarting angle = 270°+tan^(−1)(sin(θ)/(x-1/x-2 +cosθ))The above equation was tested for 10 cases and it was found to be appropriate for all the cases. Conclusion: Gantry starting angle for partial arc irradiation depends upon Breast thickness, Distance between Medial and lateral tangent and isocenter location.

60 APPLIED LIFE SCIENCES↗

Orderly disorder in magic-angle twisted trilayer graphene

Magic-angle twisted trilayer graphene (TTG) has recently emerged as a platform to engineer strongly correlated flat bands. We reveal the normal-state structural and electronic properties of TTG using low-temperature scanning tunneling microscopy at twist angles for which superconductivity has been observed. Real trilayer samples undergo a strong reconstruction of the moiré lattice, which locks layers into near–magic-angle, mirror symmetric domains comparable in size with the superconducting coherence length. This relaxation introduces an array of localized twist-angle faults, termed twistons and moiré solitons, whose electronic structure deviates strongly from the background regions, leading to a doping-dependent, spatially granular electronic landscape. The Fermi-level density of states is maximally uniform at dopings for which superconductivity has been observed in transport measurements.

Science & Technology - Other Topics↗

Programming twist angle and strain profiles in 2D materials

Moiré superlattices in twisted two-dimensional materials have generated tremendous excitement as a platform for achieving quantum properties on demand. However, the moiré pattern is highly sensitive to the interlayer atomic registry, and current assembly techniques suffer from imprecise control of the average twist angle, spatial inhomogeneity in the local twist angle, and distortions caused by random strain. We manipulated the moiré patterns in hetero- and homobilayers through in-plane bending of monolayer ribbons, using the tip of an atomic force microscope. This technique achieves continuous variation of twist angles with improved twist-angle homogeneity and reduced random strain, resulting in moiré patterns with tunable wavelength and ultralow disorder. Our results may enable detailed studies of ultralow-disorder moiré systems and the realization of precise strain-engineered devices.

Science & Technology - Other Topics↗

Structure of the surface microrelief of a droplet evaporating from a rough substrate as a possible cause of contact angle hysteresis

Based on the refraction images of a droplet evaporating on a rough substrate, we simultaneously observed the dynamics of its surface microrelief, contact angle, and contact line deformations along the entire perimeter of the contact line. This has led us conclude that the microrelief structure is directly related to the phenomenon of contact angle hysteresis and the jump-like pattern of contact line deformation. We suggest a possible mechanism for the occurrence of contact angle hysteresis during droplet evaporation and derive the relations that specify the range of possible contact angles at known microrelief parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Studying the Dependence of the Aerodynamic Characteristics of Rotating Cylinders on the Rake Angle of Air Flow

The results of experimental studies on estimating the lift force and lift coefficient of a rotating cylinder of constant cross section are presented. The data on the effect of the flow rake angle on the aerodynamic characteristics of rotating cylinders within a range of angles from 0° to 90° are analyzed. It has been established that a decrease in the lift coefficient is observed at flow rake angles above 30°, so the wind engine element shows a positive result within a range of rake angles from–30 ° ≤ α ≤ 30°. The data of these experimental studies can be used for the development of wind engines with blades designed as rotating cylinders with a smooth surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progress and opportunities in backward angle (u-channel) physics

Backward angle (u-channel) scattering provides complementary information for studies of hadron spectroscopy and structure, but has been less comprehensively studied than the corresponding forward angle case. As a result, the physics of u-channel scattering poses a range of new experimental and theoretical opportunities and questions. We summarize recent progress in measuring and understanding high energy reactions with baryon charge exchange in the u-channel, as discussed in the first Backward angle (u-channel) Physics Workshop. In particular, we discuss backward angle measurements and their theoretical description via both hadronic models and the collinear factorization approach, and discuss planned future measurements of u-channel physics. Finally, we propose outstanding questions and challenges for u-channel physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of two-dimensional small angle deviation with a prism interferometer

A new technique for the measurement of two-dimensional small angular deviation is presented. A compound prism, which effectively produces a combination of two right-angled prisms in orthogonal directions, and plane reference surfaces have been utilized for the measurement of the orthogonal components of the angular tilt of an incident plane wavefront. Each orthogonal component of the angular tilt is separately measured from the angular rotation of the resultant wedge fringes between two plane wavefronts generated due to splitting of the incident plane wavefront by the corresponding set of right-angled prism and plane reference surface. The technique is shown to have high sensitivity for the measurement of small angle deviation. A monolithic prism interferometer, which is practically insensitive to vibration, is also proposed. Results obtained for the measurement of a known tilt angle are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗