Performance analysis and data reduction for exascale scientific workflows

Chimbuko is the first in situ, scalable, workflow-level performance analysis tool for trace-level analysis and visualization of application performance. This tool was developed by the Co-design Center for Online Data Analysis and Reduction and funded by the U.S. Department of Energy’s Exascale Computing Project. We provide a detailed description of Chimbuko’s architecture and illustrate our online and offline visualization with multiple use cases. We also present results for the deployment and scalability of the tool as applied to a high-energy physics workflow running at large scale on the Frontier supercomputer.

97 MATHEMATICS AND COMPUTING↗

Cloud based tool for analysis of chemical kinetic mechanisms

The size and complexity of chemical kinetic models used to simulate combustion of hydrocarbon fuels continue to increase with our improved understanding of the underlying physical mechanisms, along with the improved ability to utilize such models as the result of increased computational power and efficiency. As mechanisms grow beyond thousands of species and tens of thousands of reactions, it becomes increasingly difficult to manually check for errors and physical inconsistencies. In this work, we present several automated methods to check for such issues in the specification of chemical reaction models. First, we demonstrate how discontinuities in thermodynamic data can cause simulation difficulties manifested as long wall-clock times and convergence failures. To correct this type of problem, we describe an automated method for refitting thermodynamic parameters. We also outline several methods to check the timescales of reaction rate coefficients to ensure physical consistency. All the methods are made available through a web-based tool (https://combustiontools.llnl.gov) intended to aid mechanism developers and users to improve the accuracy and performance of fuel models used by the combustion community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Two-Dimensional Non-Linear Magnetic Equivalent Circuit Model to Facilitate the Preliminary Design of a Normal Conducting Quadrupole

Normal conducting quadrupoles have been used to focus charged particle beams in synchrotrons, beam transfer lines, medical linacs, etc. for a long time. Optimization techniques based on analytical expressions combined with the use of a numerical field analysis tool exist in the literature for the design of an optimal pole tip shape. However, the initial shape and dimensions of the remaining yoke (including the pole itself and yoke base that act as the return path) are usually less well defined. This article discusses a design methodology for a normal conducting quadrupole based on a two-dimensional magnetic equivalent circuit. Here, this approach considers the geometry of the entire magnet and the non-linear behavior of the yoke material, thereby eliminating the initial iterations. The design outcome of this exercise serves as a competent starting point and can then be used to refine the pole tip, pole taper, yoke size, and add other geometrical features to achieve the required field quality, gradient, coil considerations, etc. by employing a finite element analysis tool. An example design study to demonstrate the proposed methodology is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of SPECT corrections on 3D-dosimetry for liver transarterial radioembolization using the patient relative calibration methodology

Purpose: Many centers aim to plan liver transarterial radioembolization (TARE) with dosimetry, even without CT-based attenuation correction (AC), or with unoptimized scatter correction (SC) methods. This work investigates the impact of presence vs absence of such corrections, and limited spatial resolution, on 3D dosimetry for TARE. Methods: Three voxelized phantoms were derived from CT images of real patients with different body sizes. Simulations of {sup 99m}Tc-SPECT projections were performed with the SIMIND code, assuming three activity distributions in the liver: uniform, inside a “liver’s segment,” or distributing multiple uptaking nodules (“nonuniform liver”), with a tumoral liver/healthy parenchyma ratio of 5:1. Projection data were reconstructed by a commercial workstation, with OSEM protocol not specifically optimized for dosimetry (spatial resolution of 12.6 mm), with/without SC (optimized, or with parameters predefined by the manufacturer; dual energy window), and with/without AC. Activity in voxels was calculated by a relative calibration, assuming identical microspheres and {sup 99m}Tc-SPECT counts spatial distribution. 3D dose distributions were calculated by convolution with {sup 90}Y voxel S-values, assuming permanent trapping of microspheres. Cumulative dose-volume histograms in lesions and healthy parenchyma from different reconstructions were compared with those obtained from the reference biodistribution (the “gold standard,” GS), assessing differences for D95%, D70%, and D50% (i.e., minimum value of the absorbed dose to a percentage of the irradiated volume). γ tool analysis with tolerance of 3%/13 mm was used to evaluate the agreement between GS and simulated cases. The influence of deep-breathing was studied, blurring the reference biodistributions with a 3D anisotropic gaussian kernel, and performing the simulations once again. Results: Differences of the dosimetric indicators were noticeable in some cases, always negative for lesions and distributed around zero for parenchyma. Application of AC and SC reduced systematically the differences for lesions by 5%–14% for a liver segment, and by 7%–12% for a nonuniform liver. For parenchyma, the data trend was less clear, but the overall range of variability passed from −10%/40% for a liver segment, and −10%/20% for a nonuniform liver, to −13%/6% in both cases. Applying AC, SC with preset parameters gave similar results to optimized SC, as confirmed by γ tool analysis. Moreover, γ analysis confirmed that solely AC and SC are not sufficient to obtain accurate 3D dose distribution. With breathing, the accuracy worsened severely for all dosimetric indicators, above all for lesions: with AC and optimized SC, −38%/−13% in liver’s segment, −61%/−40% in the nonuniform liver. For parenchyma, D50% resulted always less sensitive to breathing and sub-optimal correction methods (difference overall range: −7%/13%). Conclusions: Reconstruction protocol optimization, AC, SC, PVE and respiratory motion corrections should be implemented to obtain the best possible dosimetric accuracy. On the other side, thanks to the relative calibration, D50% inaccuracy for the healthy parenchyma from absence of AC was less than expected, while the optimization of SC was scarcely influent. The relative calibration therefore allows to perform TARE planning, basing on D50% for the healthy parenchyma, even without AC or with suboptimal corrections, rather than rely on nondosimetric methods.

60 APPLIED LIFE SCIENCES↗

Correlation of Thermally Induced Pores with Microstructural Features Using High Energy X-rays

Combined application of a near-field High Energy Diffraction Microscopy measurement of crystal lattice orientation fields and a tomographic measurement of pore distributions in a sintered nickel-based superalloy sample allows pore locations to be correlated with microstructural features. Furthermore, measurements were carried out at the Advanced Photon Source beamline 1-ID using an X-ray energy of 65 keV for each of the measurement modes. The nickel superalloy sample was prepared in such a way as to generate significant thermally induced porosity. A three-dimensionally resolved orientation map is directly overlaid with the tomographically determined pore map through a careful registration procedure. The data are shown to reliably reproduce the expected correlations between specific microstructural features (triple lines and quadruple nodes) and pore positions. With the statistics afforded by the 3D data set, we conclude that within statistical limits, pore formation does not depend on the relative orientations of the grains. The experimental procedures and analysis tools illustrated are being applied to a variety of materials problems in which local heterogeneities can affect materials properties.

36 MATERIALS SCIENCE↗

Automated ICRF heating surrogate modeling via machine learning

This work introduces automated machine learning workflows that address critical bottlenecks in surrogate model development for Ion Cyclotron Range of Frequencies (ICRF) heating applications. The automated framework includes data analysis tools that transform raw datasets into actionable insights in seconds, replacing weeks of manual exploratory effort and ensuring consistent, reproducible dataset characterization. By integrating advanced hyperparameter optimization (HPO) methods including Bayesian optimization via BoTorch and Tree-structured Parzen Estimators (TPE), the framework significantly reduces model development time from weeks to hours, decreasing computational cost and required expertise, while enabling high-accuracy surrogate models. Compared to traditional hyperparameter scanning (HPS) techniques such as methodical, randomized, and grid searches, HPO methods achieve superior convergence and predictive performance, even when compared to already well-tuned reference models. On NSTX High Harmonic Fast Wave (HHFW) heating datasets, both Random Forest Regressor (RFR) and neural network surrogates demonstrate improved accuracy, achieving R 2 values beyond 0.97 and 0.98, respectively. The results show that while HPO gains are modest for robust architectures like RFR, they become essential for more sensitive models such as neural networks, highlighting the trade-offs across optimization strategies. Through automated workflows that eliminate manual hyperparameter tuning and require minimal ML expertise, this work enables widespread adoption of high-fidelity surrogate models across the fusion community for real-time plasma control, uncertainty quantification, rapid experimental scenario development, and integrated system optimization.

Sanchez-Villar, Alvaro [Princeton Plasma Physics L↗

SU-E-J-182: Reproducibility of Tumor Motion Probability Distribution Function in Stereotactic Body Radiation Therapy of Lung Using Real-Time Tumor-Tracking Radiotherapy System

Purpose: We aim to achieve new four-dimensional radiotherapy (4DRT) using the next generation real-time tumor-tracking (RTRT) system and flattening-filter-free techniques. To achieve new 4DRT, it is necessary to understand the respiratory motion of tumor. The purposes of this study were: 1.To develop the respiratory motion analysis tool using log files. 2.To evaluate the reproducibility of tumor motion probability distribution function (PDF) during stereotactic body RT (SBRT) of lung tumor. Methods: Seven patients having fiducial markers closely implanted to the lung tumor were enrolled in this study. The positions of fiducial markers were measured using the RTRT system (Mitsubishi Electronics Co., JP) and recorded as two types of log files during the course of SBRT. For each patients, tumor motion range and tumor motion PDFs in left-right (LR), anterior-posterior (AP) and superior-inferior (SI) directions were calculated using log files of all beams per fraction (PDFn). Fractional PDF reproducibility (Rn) was calculated as Kullback-Leibler (KL) divergence between PDF1 and PDFn of tumor motion. The mean of Rn (Rm) was calculated for each patient and correlated to the patient’s mean tumor motion range (Am). The change of Rm during the course of SBRT was also evluated. These analyses were performed using in-house developed software. Results: The Rm were 0.19 (0.07–0.30), 0.14 (0.07–0.32) and 0.16 (0.09–0.28) in LR, AP and SI directions, respectively. The Am were 5.11 mm (2.58–9.99 mm), 7.81 mm (2.87–15.57 mm) and 11.26 mm (3.80–21.27 mm) in LR, AP and SI directions, respectively. The PDF reproducibility decreased as the tumor motion range increased in AP and SI direction. That decreased slightly through the course of RT in SI direction. Conclusion: We developed the respiratory motion analysis tool for 4DRT using log files and quantified the range and reproducibility of respiratory motion for lung tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the interplay effects with proton scanning beams in stage III lung cancer

Purpose: To assess the dosimetric impact of interplay between spot-scanning proton beam and respiratory motion in intensity-modulated proton therapy (IMPT) for stage III lung cancer. Methods: Eleven patients were sampled from 112 patients with stage III nonsmall cell lung cancer to well represent the distribution of 112 patients in terms of target size and motion. Clinical target volumes (CTVs) and planning target volumes (PTVs) were defined according to the authors' clinical protocol. Uniform and realistic breathing patterns were considered along with regular- and hypofractionation scenarios. The dose contributed by a spot was fully calculated on the computed tomography (CT) images corresponding to the respiratory phase that the spot is delivered, and then accumulated to the reference phase of the 4DCT to generate the dynamic dose that provides an estimation of what might be delivered under the influence of interplay effect. The dynamic dose distributions at different numbers of fractions were compared with the corresponding 4D composite dose which is the equally weighted average of the doses, respectively, computed on respiratory phases of a 4DCT image set. Results: Under regular fractionation, the average and maximum differences in CTV coverage between the 4D composite and dynamic doses after delivery of all 35 fractions were no more than 0.2% and 0.9%, respectively. The maximum differences between the two dose distributions for the maximum dose to the spinal cord, heart V40, esophagus V55, and lung V20 were 1.2 Gy, 0.1%, 0.8%, and 0.4%, respectively. Although relatively large differences in single fraction, correlated with small CTVs relative to motions, were observed, the authors' biological response calculations suggested that this interfractional dose variation may have limited biological impact. Assuming a hypofractionation scenario, the differences between the 4D composite and dynamic doses were well confined even for single fraction. Conclusions: Despite the presence of interplay effect, the delivered dose may be reliably estimated using the 4D composite dose. In general the interplay effect may not be a primary concern with IMPT for lung cancers for the authors' institution. The described interplay analysis tool may be used to provide additional confidence in treatment delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automating linear accelerator quality assurance

Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. Conclusions: The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.

60 APPLIED LIFE SCIENCES↗

Risk-based monitoring designs for detecting CO 2 leakage through abandoned wellbores: An application of NRAP’s WLAT and DREAM tools

We report that one suggested approach to managing the risk of geologic CO 2 storage projects is to perform risk-based subsurface monitoring targeting early leak detection. The challenge in risk-based monitoring is that leakage impacts are expected to be small in comparison with the footprint of the stored CO 2 plume and could be at depths ranging from the depth of storage (often ~1 km bgs) up to surficial aquifers. Addressing this challenge requires a multidisciplinary effort capable of characterizing potential subsurface leakage in terms of likelihood, location, magnitude, impacts to overlying aquifers, and uncertainty as well as innovative monitoring technology design and implementation. The National Risk Assessment Partnership (NRAP) was established to develop related risk assessment tools to provide guidance on such assessments. Here we demonstrate the application workflow of two of the NRAP computational tools, WLAT (Wellbore Leakage Analysis Tool) and DREAM (Designs for Risk Evaluation and Management), to a hypothetical CO 2 storage site based on a study area in the Midwestern United States. This workflow shows how CO 2 leakage may be estimated, evaluated, and monitored in terms of risk. Results provide guidance on monitoring configurations and technologies which minimize the time to leak detection, maximize the probability detection, and provide cost considerations.

54 ENVIRONMENTAL SCIENCES↗

Generalizability analysis of tool condition monitoring ensemble machine learning models

Tool condition monitoring (TCM) is an essential research area for the optimization and automation of metal machining processes, and could help manufacturers reduce costs, production time, machine downtime, energy use, and part scrappage. However, TCM systems developed in prior studies have struggled to reach the high level of generalizability which is necessary for industrial applications. This study addresses TCM system generalizability to new machining conditions, how variations in machining and environmental conditions may be used to improve model generalizability, and ensemble machine learning techniques for TCM. Further, milling tool life experiments were conducted using various machining conditions, and the processes' sound, spindle power, and axial load signals were collected. Different machine learning models were evaluated for the prediction of tool wear levels, including four individual models and five ensemble models. Changes in cutting speed were found to display a large effect on model performance, while the chip load showed some effect, and the feed rate had little effect. A simulated noise data augmentation technique for model improvement is applied within TCM for the first time, and resulted in increased model generalizability and reduced overfitting. Across several performance metrics the extremely randomized trees ensemble machine learning model generally performed the best for this application, achieving a leave-one-group-out cross validation accuracy score of 92.4 %, a 10-fold cross validation score of 98.9 %, and an averaged accuracy across 11 generalizability tests of 87.3 %.

42 ENGINEERING↗

New surface characterization tools for alumina based refractory material exposed to cavitation - Image analysis and pattern recognition approach

Highlights: • Surface degradation was monitored via mass loss measurement. • Observation of surface damage destruction was done using image analysis. • Shape parameters of surface defects change during cavitation. • Shape parameters changes are correlated to mass loss measurements. - Abstract: The aim of this study was to examine the influence of cavitation erosion on the morphology of defects formed on the surfaces of alumina-based materials. The alumina-based samples were exposed to cavitation erosion for 42 min. The damages that occurred were monitored at predefined time intervals by measuring the mass loss and observing the sample surfaces. Digital images of surfaces were processed using an image analysis software package to define morphological characteristics of the damages occurred. The calculated morphological parameters were subjected to analysis by pattern recognition techniques to correlate the appearance of particular morphological characteristics with the behavior of the material during cavitation erosion. The newly established method in describing cavitation erosion which uses pattern recognition approach for treatments of morphological parameters calculated for damages by image analysis tools gave the results efficient for material characterization as the traditional one.

36 MATERIALS SCIENCE↗

Optimizing fine-grained communication in a biomolecular simulation application on Cray XK6

Achieving good scaling for fine-grained communication intensive applications on modern supercomputers remains challenging. In our previous work, we have shown that such an application -- NAMD -- scales well on the full Jaguar XT5 without long-range interactions; Yet, with them, the speedup falters beyond 64K cores. Although the new Gemini interconnect on Cray XK6 has improved network performance, the challenges remain, and are likely to remain for other such networks as well. We analyze communication bottlenecks in NAMD and its CHARM++ runtime, using the Projections performance analysis tool. Based on the analysis, we optimize the runtime, built on the uGNI library for Gemini. We present several techniques to improve the fine-grained communication. Consequently, the performance of running 92224-atom Apoa1 with GPUs on TitanDev is improved by 36%. For 100-million-atom STMV, we improve upon the prior Jaguar XT5 result of 26 ms/step to 13 ms/step using 298,992 cores on Jaguar XK6.

Sun, Yanhua↗

Tools for analysis of optimization models

The software is code for analyzing, debugging, and solving optimization models. The code implements several algorithms and provides convenient APIs to apply these algorithms to optimization models. The algorithms are primarily based on graph theory. They compute well-known partitions of graphs, and use these partitions to provide the user information about their optimization model, including diagnosing certain types of structural modeling errors. Some algorithms may be used as a subroutine to solve an optimization problem, and may call an optimization solver to facilitate this. Well-known linear algebra routines are called to provide further diagnostics. The software contains no data and no models other than toy models used for testing.

Parker, Robert↗

Optimizing the performance of reactive molecular dynamics simulations for many-core architectures

Reactive molecular dynamics simulations are computationally demanding. Reaching spatial and temporal scales where interesting scientific phenomena can be observed requires efficient and scalable implementations on modern hardware. In this article, we focus on optimizing the performance of the widely used LAMMPS/ReaxC package for many-core architectures. As hybrid parallelism allows better leverage of the increasing on-node parallelism, we adopt thread parallelism in the construction of bonded and nonbonded lists and in the computation of complex ReaxFF interactions. To mitigate the I/O overheads due to large volumes of trajectory data produced and to save users the burden of post-processing, we also develop a novel in situ tool for molecular species analysis. We analyze the performance of the resulting ReaxC-OMP package on two different architectures: (i) Mira, an IBM Blue Gene/Q system and (ii) Cori-II, a Cray XC-40 sytem with Knights Landing processors. For Pentaerythritol tetranitrate (PETN) systems of sizes ranging from 32 thousand to 16.6 million particles, we observe speedups in the range of 1.5-4.5x. We observe sustained performance improvements for up to 262,144 cores (1,048,576 processes) of Mira and a weak scaling efficiency of 91.5% in large simulations containing 16.6 million particles. Finally, the in situ molecular species analysis tool incurs only insignificant overheads across various system sizes and runs configurations.

97 MATHEMATICS AND COMPUTING↗

SIND Operational Analysis and Tools Improvement (Final Technical Report)

The goal of the SIND Toolkit project is to create a new national solar database with higher temporal and spatial resolution to reduce the costs and risks of integrating solar power systems into the electric power grid. Previous versions of this dataset from the WWSIS2 study and the ERGIS study have already been widely utilized by academics, utilities, and others after having been made publically available. This dataset, along with its companion WIND Toolkit dataset (Draxl, Clifton, Hodge, & McCaa, 2015), will be utilized for the next 5 – 10 years as the foundation for the vast majority of new grid integration studies.