Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Atomic layer deposition for aligned growth of and conformal deposition onto double and triple walled carbon nanotubes

We present our work on the growth and functionalization of carbon nanotubes (CNTs). A significant challenge in the growth of aligned single, double and triple walled nanotubes is in the deposition of a controlled thickness catalyst layer. Conventional techniques using line of sight deposition such as sputtering and evaporation produce uniform catalyst layers only when extreme care is taken in the placement of flat substrates. Growth of aligned low wall number carbon nanotubes on contoured, complex geometry, or large surface area substrates is simply not technically feasible through these techniques. Using iron atomic layer deposition (ALD) with ferrocene and oxygen precursors for catalyst deposition circumvents the line of sight problems and allows for uniform coverage across almost all substrates. Furthermore the ALD technique allows for extremely accurate and reproducible thickness depositions. Using these ALD catalyst layers reproducible aligned arrays consisting of primarily double and triple wall CNTS can be fabricated. Conformal coatings onto high aspect ratio surfaces are particularly challenging. The walls of single carbon nanotubes in a nanotube array are inaccessible by line of sight techniques. ALD circumvents this problem by relying on a gas-surface reaction to initiate growth. Generally, growth of ALD films on CNTs results in beading of the deposited materials around CNT defects. This is particularly true of high surface energy materials. The number of nucleation sites and the onset of growth of Pt by ALD can be tuned by use of Ar plasma, O 2 plasma and chemical functionalization.

30 DIRECT ENERGY CONVERSION↗

A convenient alignment approach for x-ray imaging experiments based on laser positioning devices

This study presents a two-laser alignment approach for facilitating the precise alignment of various imaging and measuring components with respect to the x-ray beam. The first laser constantly pointed to the output window of the source, in a direction parallel to the path along which the components are placed. The second laser beam, originating from the opposite direction, was calibrated to coincide with the first laser beam. Thus, a visible indicator of the direction of the incident x-ray beam was established, and the various components could then be aligned conveniently and accurately with its help.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-94: Positioning Errors Resulting From Using Bony Anatomy Alignment for Treating SBRT Lung Tumor

Purpose: To quantify patient setups errors based on bony anatomy registration rather than 3D tumor alignment for SBRT lung treatments. Method: A retrospective study was performed for patients treated with lung SBRT and imaged with kV cone beam computed tomography (kV-CBCT) image-guidance. Daily CBCT images were registered to treatment planning CTs based on bony anatomy alignment and then inter-fraction tumor movement was evaluated by comparing shift in the tumor center in the medial-lateral, anterior-posterior, and superior-inferior directions. The PTV V100% was evaluated for each patient based on the average daily tumor displacement to assess the impact of the positioning error on the target coverage when the registrations were based on bony anatomy. Of the 35 patients studied, 15 were free-breathing treatments, 10 used abdominal compression with a stereotactic body frame, and the remaining 10 were performed with BodyFIX vacuum bags. Results: For free-breathing treatments, the range of tumor displacement error is between 1–6 mm in the medial-lateral, 1–13 mm in the anterior-posterior, and 1–7 mm in the superior-inferior directions. These positioning errors lead to 6–22% underdose coverage for PTV - V100% . Patients treated with abdominal compression immobilization showed positional errors of 0–4mm mediallaterally, 0–3mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% underdose ranging between 6–17%. For patients immobilized with the vacuum bags, the positional errors were found to be 0–1 mm medial-laterally, 0–1mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% under dose ranging between 5–6% only. Conclusion: It is necessary to align the tumor target by using 3D image guidance to ensure adequate tumor coverage before performing SBRT lung treatments. The BodyFIX vacuum bag immobilization method has the least positioning errors among the three methods studied when bony anatomy is used for registration.

60 APPLIED LIFE SCIENCES↗

Alignment of RNA molecules: Binding energy and statistical properties of random sequences

A new statistical approach to the problem of pairwise alignment of RNA sequences is proposed. The problem is analyzed for a pair of interacting polymers forming an RNA-like hierarchical cloverleaf structures. An alignment is characterized by the numbers of matches, mismatches, and gaps. A weight function is assigned to each alignment; this function is interpreted as a free energy taking into account both direct monomer-monomer interactions and a combinatorial contribution due to formation of various cloverleaf secondary structures. The binding free energy is determined for a pair of RNA molecules. Statistical properties are discussed, including fluctuations of the binding energy between a pair of RNA molecules and loop length distribution in a complex. Based on an analysis of the free energy per nucleotide pair complexes of random RNAs as a function of the number of nucleotide types c, a hypothesis is put forward about the exclusivity of the alphabet c = 4 used by nature.

60 APPLIED LIFE SCIENCES↗

Structure and Characterization of Vertically Aligned Single-Walled Carbon Nanotube Bundles

Arrays of vertically aligned single-walled carbon nanotube bundles, SWCNTs, have been synthesized by simple alcohol catalytic chemical vapor deposition process, carried out at 800 ° C . The formed SWCNTs are organized in small groups perpendicularly aligned and attached to the substrate. These small bundles show a constant diameter of ca. 30 nm and are formed by the adhesion of no more than twenty individual SWCNTs perfectly aligned along their length.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

ADEPT: a domain independent sequence alignment strategy for gpu architectures

Bioinformatic workflows frequently make use of automated genome assembly and protein clustering tools. At the core of most of these tools, a significant portion of execution time is spent in determining optimal local alignment between two sequences. This task is performed with the Smith-Waterman algorithm, which is a dynamic programming based method. With the advent of modern sequencing technologies and increasing size of both genome and protein databases, a need for faster Smith-Waterman implementations has emerged. Multiple SIMD strategies for the Smith-Waterman algorithm are available for CPUs. However, with the move of HPC facilities towards accelerator based architectures, a need for an efficient GPU accelerated strategy has emerged. Existing GPU based strategies have either been optimized for a specific type of characters (Nucleotides or Amino Acids) or for only a handful of application use-cases. In this paper, we present ADEPT, a new sequence alignment strategy for GPU architectures that is domain independent, supporting alignment of sequences from both genomes and proteins. Our proposed strategy uses GPU specific optimizations that do not rely on the nature of sequence. We demonstrate the feasibility of this strategy by implementing the Smith-Waterman algorithm and comparing it to similar CPU strategies as well as the fastest known GPU methods for each domain. ADEPT’s driver enables it to scale across multiple GPUs and allows easy integration into software pipelines which utilize large scale computational systems. We have shown that the ADEPT based Smith-Waterman algorithm demonstrates a peak performance of 360 GCUPS and 497 GCUPs for protein based and DNA based datasets respectively on a single GPU node (8 GPUs) of the Cori Supercomputer. Overall ADEPT shows 10x faster performance in a node-to-node comparison against a corresponding SIMD CPU implementation. ADEPT demonstrates a performance that is either comparable or better than existing GPU strategies. We demonstrated the efficacy of ADEPT in supporting existing bionformatics software pipelines by integrating ADEPT in MetaHipMer a high-performance denovo metagenome assembler and PASTIS a high-performance protein similarity graph construction pipeline. Our results show 10% and 30% boost of performance in MetaHipMer and PASTIS respectively.

59 BASIC BIOLOGICAL SCIENCES↗

Benchmarking of alignment-free sequence comparison methods

Background: Alignment-free (AF) sequence comparison is attracting persistent interest driven by data-intensive applications. Hence, many AF procedures have been proposed in recent years, but a lack of a clearly defined benchmarking consensus hampers their performance assessment. Results: Here, we present a community resource (http://afproject.org) to establish standards for comparing alignment-free approaches across different areas of sequence-based research. We characterize 74 AF methods available in 24 software tools for five research applications, namely, protein sequence classification, gene tree inference, regulatory element detection, genome-based phylogenetic inference, and reconstruction of species trees under horizontal gene transfer and recombination events. Conclusion: The interactive web service allows researchers to explore the performance of alignment-free tools relevant to their data types and analytical goals. It also allows method developers to assess their own algorithms and compare them with current state-of-the-art tools, accelerating the development of new, more accurate AF solutions

59 BASIC BIOLOGICAL SCIENCES↗

Linac Alignment Algorithm: Analysis on 1-to-1 Steering

In a linear accelerator, it is important to achieve a good alignment between all of its components (such as quadrupoles, RF cavities, beam position monitors et al.), in order to better preserve the beam quality during acceleration. After the survey of the main linac components, there are several beam-based alignment (BBA) techniques to be applied, to further optimize the beam trajectory and calculate the corresponding steering magnets strength. Among these techniques the most simple and straightforward one is the one-to-one (1-to-1) steering technique, which steers the beam from quad center to center, and removes the betatron oscillation from quad focusing. For a future linear collider such as the International Linear Collider (ILC), the initial beam emittance is very small in the vertical plane (flat beam with {gamma}{epsilon}{sub y} = 20-40nm), which means the alignment requirement is very tight. In this note, we evaluate the emittance growth with one-to-one correction algorithm employed, both analytically and numerically. Then the ILC main linac accelerator is taken as an example to compare the vertical emittance growth after 1-to-1 steering, both from analytical formulae and multi-particle tracking simulation. It is demonstrated that the estimated emittance growth from the derived formulae agrees well with the results from numerical simulation, with and without acceleration, respectively.

43 PARTICLE ACCELERATORS↗

Laboratory Guide for Residual Stress Sample Alignment and Experiment Planning-October 2011 Version

The December 2010 version of the guide, ORNL/TM-2008/159, by Jeff Bunn, Josh Schmidlin, Camden Hubbard, and Paris Cornwell, has been further revised due to a major change in the GeoMagic Studio software for constructing a surface model. The Studio software update also includes a plug-in module to operate the FARO Scan Arm. Other revisions for clarity were also made. The purpose of this revision document is to guide the reader through the process of laser alignment used by NRSF2 at HFIR and VULCAN at SNS. This system was created to increase the spatial accuracy of the measurement points in a sample, reduce the use of neutron time used for alignment, improve experiment planning, and reduce operator error. The need for spatial resolution has been driven by the reduction in gauge volumes to the sub-millimeter level, steep strain gradients in some samples, and requests to mount multiple samples within a few days for relating data from each sample to a common sample coordinate system. The first step in this process involves mounting the sample on an indexer table in a laboratory set up for offline sample mounting and alignment in the same manner it would be mounted at either instrument. In the shared laboratory, a FARO ScanArm is used to measure the coordinates of points on the sample surface ('point cloud'), specific features and fiducial points. A Sample Coordinate System (SCS) needs to be established first. This is an advantage of the technique because the SCS can be defined in such a way to facilitate simple definition of measurement points within the sample. Next, samples are typically mounted to a frame of 80/20 and fiducial points are attached to the sample or frame then measured in the established sample coordinate system. The laser scan probe on the ScanArm can then be used to scan in an 'as-is' model of the sample as well as mounting hardware. GeoMagic Studio 12 is the software package used to construct the model from the point cloud the scan arm creates. Once a model, fiducial, and measurement files are created, a special program, called SScanSS combines the information and by simulation of the sample on the diffractometer can help plan the experiment before using neutron time. Finally, the sample is mounted on the relevant stress measurement instrument and the fiducial points are measured again. In the HFIR beam room, a laser tracker is used in conjunction with a program called CAM2 to measure the fiducial points in the NRSF2 instrument's sample positioner coordinate system. SScanSS is then used again to perform a coordinate system transformation of the measurement file locations to the sample positioner coordinate system. A procedure file is then written with the coordinates in the sample positioner coordinate system for the desired measurement locations. This file is often called a script or command file and can be further modified using excel. It is very important to note that this process is not a linear one, but rather, it often is iterative. Many of the steps in this guide are interdependent on one another. It is very important to discuss the process as it pertains to the specific sample being measured. What works with one sample may not necessarily work for another. This guide attempts to provide a typical work flow that has been successful in most cases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proposal for the Alignment of the 'Loose End'

The 'loose end' of the girder presents an alignment problem because there is no beam based alignment procedure available to position it. The positioning always depends on the fiducialization of the undulator. A direct way to position the 'loose end' to the next quadrupole is to measure their fiducials in relation to each other. By spanning a wire over a distance of several girders, each undulator and quadrupole can be measured by reading its distance to the wire with a portable wire sensor. The pitch of a girder can be determined by measuring height differences at different points on the girder. To measure the height differences a portable HLS is used. During the measurements of the portable system the permanent Wire Position Monitor and the permanent HLS are used to monitor the interim movements of the girder. After the initial alignment the position of the 'loose end' can be monitored with the permanent systems in relation to the quadrupoles.

43 PARTICLE ACCELERATORS↗

Impact of Lateral Alignment for Cooling Airflow during Heavy-Truck Platooning

A truck platooning system was tested using two heavy-duty tractor-trailer trucks on a closed test track to investigate the thermal control/heat rejection system sensitivity to intentional lateral offsets over a range of intervehicle spacings. Previous studies have shown the following vehicle can experience elevated temperatures and reduced airflow through the cooling package as a result of close-formation platooning. Four anemometers positioned across the grille of the following trucks as well as aligned and multiple offset positions are used to evaluate the sensitivity of the impact. Straight sections of the track are isolated for the most accurate airflow impact measurements and to be most representative of on-highway driving. An intentional lateral offset in truck platooning is considered as a controls approach to mitigate reduced cooling efficacy at close following scenarios where the highest platoon savings are achieved. The truck platooning system was tested at four gap distances from 9 to 23 meters and the following truck was either aligned with the lead or offset with a 25% width (0.65 m) or 50% width (1.3 m) lateral distance. The experimental results clearly show that offset driving is effective at bringing cooling airflow from 56% with an aligned platoon back up to 75%-80% with minimal impact to fuel savings. In addition, the offset driving can also reduce the trailing truck’s engine coolant temperature by 2°C and the corresponding underhood temperature rise by 10°C. The test outcomes indicate a plausible controls strategy to mitigate reduced cooling flow during hot-weather truck platooning while still enabling the highest-energy-saving, close-following scenarios.

27 ARPA - Advanced Research Projects Agency-Energy↗

Accurate Alignment of Plasma Channels Based on Laser Centroid Oscillations

A technique has been developed to accurately align a laser beam through a plasma channel by minimizing the shift in laser centroid and angle at the channel outptut. If only the shift in centroid or angle is measured, then accurate alignment is provided by minimizing laser centroid motion at the channel exit as the channel properties are scanned. The improvement in alignment accuracy provided by this technique is important for minimizing electron beam pointing errors in laser plasma accelerators.

43 PARTICLE ACCELERATORS↗

Strategies and Lessons-Learned for the Successful Alignment of Contract Cost with the Contract Budget Base (CBB) within the First Year of Contract Award - 13154

In order to provide a sound basis and foundation for integrated Project and Contract change management, it is imperative to ensure the alignment of the Negotiated Contract Costs (NCC) with the Contract Budget Base (CBB), where CBB is defined as the Performance Measurement Baseline (PMB) plus Management Reserve (MR). The achievement of this alignment assures customer and contractor agreement on scope, requirements, quantities, schedule and cost, which facilitates the identification of change conditions and ultimate agreement on the value of changes to the NCC and the CBB. Delays in contract/CBB true up/reconciliation can negatively effect measurement of project progress, limiting owner understanding of liability, and may result in increased contract disagreements and potential claims. The Department of Energy Oak Ridge Office of Environmental Management (OR-EM) and URS - CH2M Oak Ridge LLC (UCOR) achieved alignment of the NCC with the CBB within 10 months of UCOR taking over work on the East Tennessee Technology Park (ETTP) cleanup contract by: 1. Managing as a discrete project; 2. Establishing expectations and setting tone of interactions; 3. Using personnel experienced with Federal Acquisition Regulation (FAR); 4. Partnering; 5. Establishing ombudsmen. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The JCSG MR Pipeline: Optimized Alignments, Multiple Models And Parallel Searches

The success rate of molecular replacement (MR) falls considerably when search models share less than 35% sequence identity with their templates, but can be improved significantly by using fold-recognition methods combined with exhaustive MR searches. Models based on alignments calculated with fold-recognition algorithms are more accurate than models based on conventional alignment methods such as FASTA or BLAST, which are still widely used for MR. In addition, by designing MR pipelines that integrate phasing and automated refinement and allow parallel processing of such calculations, one can effectively increase the success rate of MR. Here, updated results from the JCSG MR pipeline are presented, which to date has solved 33 MR structures with less than 35% sequence identity to the closest homologue of known structure. By using difficult MR problems as examples, it is demonstrated that successful MR phasing is possible even in cases where the similarity between the model and the template can only be detected with fold-recognition algorithms. In the first step, several search models are built based on all homologues found in the PDB by fold-recognition algorithms. The models resulting from this process are used in parallel MR searches with different combinations of input parameters of the MR phasing algorithm. The putative solutions are subjected to rigid-body and restrained crystallographic refinement and ranked based on the final values of free R factor, figure of merit and deviations from ideal geometry. Finally, crystal packing and electron-density maps are checked to identify the correct solution. If this procedure does not yield a solution with interpretable electron-density maps, then even more alternative models are prepared. The structurally variable regions of a protein family are identified based on alignments of sequences and known structures from that family and appropriate trimmings of the models are proposed. All combinations of these trimmings are applied to the search models and the resulting set of models is used in the MR pipeline. It is estimated that with the improvements in model building and exhaustive parallel searches with existing phasing algorithms, MR can be successful for more than 50% of recognizable homologues of known structures below the threshold of 35% sequence identity. This implies that about one-third of the proteins in a typical bacterial proteome are potential MR targets.

59 BASIC BIOLOGICAL SCIENCES↗

Implementation of Accelerated Beam-Specific Matched-Filter-Based Optical Alignment

Accurate automated alignment of laser beams in the National Ignition Facility (NIF) is essential for achieving extreme temperature and pressure required for inertial confinement fusion. The alignment achieved by the integrated control systems relies on algorithms processing video images to determine the position of the laser beam images in real-time. Alignment images that exhibit wide variations in beam quality require a matched-filter algorithm for position detection. One challenge in designing a matched-filter based algorithm is to construct a filter template that is resilient to variations in imaging conditions while guaranteeing accurate position determination. A second challenge is to process the image as fast as possible. This paper describes the development of a new analytical template that captures key recurring features present in the beam image to accurately estimate the beam position under good image quality conditions. Depending on the features present in a particular beam, the analytical template allows us to create a highly tailored template containing only those selected features. The second objective is achieved by exploiting the parallelism inherent in the algorithm to accelerate processing using parallel hardware that provides significant performance improvement over conventional processors. In particular, a Xilinx Virtex II Pro FPGA hardware implementation processing 32 templates provided a speed increase of about 253 times over an optimized software implementation running on a 2.0 GHz AMD Opteron core.

42 ENGINEERING↗

On the field‐aligned electric field in the polar cap

Abstract The Johns Hopkins University Applied Physics Laboratory open‐field line particle precipitation model predicts downward field‐aligned electric field to maintain charge quasi‐neutrality. Previous studies confirmed the existence of such electric fields. However, the present study shows that upward field‐aligned electric field can be found within upward field‐aligned current (FAC) region. In the upward FAC region, upward electric field that accelerates electron downward is seen with the occurrence rates of 82%–96%. In contrast, the occurrence rates in the downward FAC regions are 3%–11%. Polar rain electrons located in the upward FAC region adjacent to closed field lines often show a ramping up of energy with increasing latitude before reaching a plateau. This plateau may be attributed to the magnetosheath electrons that progressively have higher antisunward velocity and lower density with increasing distance from the subsolar point before they asymptotically reach the solar wind values.

Wing, Simon↗

Surface‐Enforced Alignment of Reprogrammable Liquid Crystalline Elastomers

Abstract Liquid crystalline elastomers (LCEs) are stimuli‐responsive materials capable of undergoing large deformations. The thermomechanical response of LCEs is attributable to the coupling of polymer network properties and disruption of order between liquid crystalline mesogens. Complex deformations have been realized in LCEs by either programming the nematic director via surface‐enforced alignment or localized mechanical deformation in materials incorporating dynamic covalent chemistries. Here, the preparation of LCEs via thiol‐Michael addition reaction is reported that are amenable to surface‐enforced alignment. Afforded by the thiol‐Michael addition reaction, dynamic covalent bonds are uniquely incorporated in chemistries subject to surface‐enforce alignment. Accordingly, LCEs prepared with complex director profiles are able to be programmed and reprogrammed by (re)activating the dynamic covalent chemistry to realize distinctive shape transformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Room-Temperature Phototransistor with Negative Photoresponsivity of 10 8 A W -1 Using Fullerene-Sensitized Aligned Carbon Nanotubes

Detection of low intensity light down to a few photons requires photodetectors with high gain. In this paper, a new photodetector is reported based on C 60 -sensitized aligned carbon nanotube (CNT) transistors with an extremely high responsivity of 10 8 A W -1 (gain > 10 8 ) in the ultraviolet and visible range, and 720 A W -1 (gain = 940) in the infrared range. In contrast to most sensitized phototransistors that operate on the photogating effect, the new photodetector operates on the modulation of the electrons scattering in the CNTs, leading to negative photoconductivity. Comparison with similar photodetectors using random CNT networks shows the benefit of using aligned CNTs. Finally, at room temperature, the aligned CNT photodetectors are demonstrated to detect a few tens of photons per CNT.

47 OTHER INSTRUMENTATION↗