Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Considerations for the temperature stratification in a pre-burn constant-volume combustion chamber

In recent years, the Engine Combustion Network (ECN) has developed as a worldwide reference for understanding and describing engine combustion processes, successfully bringing together experimental and numerical efforts. Since experiments and numerical simulations both target the same boundary conditions, an accurate characterization of the stratified environment that is inevitably present in experimental facilities is required. The difference between the core-, and pressure-derived bulk-temperature of pre-burn combustion vessels has been addressed in various previous publications. Additionally, thermocouple measurements have provided initial data on the boundary layer close to the injector nozzle, showing a transition to reduced ambient temperatures. The conditions at the start of fuel injection influence physicochemical properties of a fuel spray, including near nozzle mixing, heat release computations, and combustion parameters. To address the temperature stratification in more detail, thermocouple measurements at larger distances from the spray axis have been conducted. Both the temperature field prior to the pre-combustion event that preconditions the high-temperature, high-pressure ambient, as well as the stratification at the moment of fuel injection were studied. To reveal the cold boundary layer near the injector with a better spatial resolution, Rayleigh scattering experiments and thermocouple measurements at various distances close to the nozzle have been carried out. The impact of the boundary layers and temperature stratification are illustrated and quantified using numerical simulations at Spray A conditions. Next to a reference simulation with a uniform temperature field, six different stratified temperature distributions have been generated. These distributions were based on the mean experimental temperature superimposed by a randomized variance, again derived from the experiments. The results showed that an asymmetric flame structure arises in the computed results when the temperature stratification input is used. In these predictions, first-stage ignition is advanced by 24 $\mu$s , while second-stage ignition is delayed by 11 $\mu$s. At the same time a lift-off length difference between the top and the bottom of up to 1.1 mm is observed. Furthermore, the lift-off length is less stable over time. Given the shown dependency, the temperature data is made available along with the vessel geometry data as a recommended basis for future numerical simulations.

42 ENGINEERING↗

Hydrogen adsorption and transport in clay-rich geomaterials: Implications for large-volume underground hydrogen storage

Depleted oil and gas reservoirs, characterized by impermeable clay-rich caprocks, are promising sites for large-scale underground hydrogen storage (UHS), which is a key strategy to support hydrogen-based energy systems. However, experimental data on hydrogen storage in clay-rich geomaterials remain scarce. In this work, we experimentally investigated hydrogen adsorption and migration in clay-rich geomaterials in the presence of nitrogen and water under controlled temperatures. Experimental observations showed that hydrogen was adsorbed in dry illite. A dual-porosity transport model was developed to interpret hydrogen transport between large-pore and small-pore domains in illite. The large-pore domain is the space between clay particles (i.e., inter-particle space), whereas the small-pore domain is the nanoscale pore space between clay mineral layers (i.e., inter-layer or intra-particle space). In contrast, nitrogen showed no evidence of adsorption in dry illite because it cannot move into the small-pore domain due to the relatively large kinetic diameter, referred to as the molecular sieving effect. Here, we found that 0.7–1.3 nm is the length scale regulating this molecular sieving effect, matching the interlayer spacing in illite, suggesting that nitrogen is a promising cushion gas in UHS, which aims to maintain adequate pressure in the reservoir for economic operations. In wetted illite, hydrogen was not adsorbed into the interlayer space due to the occupation of adsorption sites by interlayer water, which highlights the critical role of the clay hydration state in controlling hydrogen-clay interactions. Additionally, hydrogen adsorption experiments on crushed shale indicated that the shale surface possessed adsorption sites more favorable for hydrogen than for nitrogen. Through these experiments, we provide new insights into hydrogen storage mechanisms in clay-rich geomaterials and offer valuable laboratory data for evaluating the performance of large-scale UHS systems.

Adsorption↗

A Novel Analytical Population Tumor Control Probability Model Includes Cell Density and Volume Variations: Application to Canine Brain Tumor

Tumor control probability (TCP) models based on Poisson statistics characterize the distribution of surviving clonogens. Thus enabling the calculation of TCP for individuals. To mathematically describe clinically observed survival data of patient cohorts it is necessary to extend the Poisson TCP model. This is typically done by either incorporating variations of model parameters or by using an empirical logistic model. The purpose of this work is the development of an analytical population TCP model by mechanistic extension of the Possion model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗