Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Coordinated Optimal Control of PV Inverters and HVAC Loads in Distribution Systems

The increasing integration of distributed energy resources (DERs), such as photovoltaics (PVs) and smart buildings into distribution systems complicate power system operation and controls. This paper proposes a coordinated optimal control strategy for PV inverters and Heating, ventilation, and air conditioning (HVAC) loads in smart buildings to minimize the total network loss in a distribution system. For the HVAC units, we enforce minimum on and off time constraints to avoid frequent switching that can degrade the unit. The proposed control will dispatch optimal control signals of active and reactive power to PV inverters and on/off commands to HVAC units while maintaining the nodal voltage within a secure range and the temperature of HVAC units at a comfort level. The simulation results on a modified IEEE 33-node distribution system demonstrate that the proposed coordinated control scheme can reduce the network loss.

Pani, Naveen↗

A Critical Exploration of the Efficiency Impacts of Demand Response From HVAC in Commercial Buildings

Increasing quantities of renewable energy generation has yielded a need for greater energy storage capacity in power systems. Thermal storage in variable air volume (VAV) heating, ventilation, and air conditioning (HVAC) in commercial buildings has been identified as an inexpensive source of grid storage, but the true costs are not known. Recent literature explores the inefficiency associated with providing grid services from these HVAC-based demand response (DR) resources by employing a battery analogy to calculate round-trip efficiency (RTE). Results vary significantly across studies and in some cases reported efficiencies are strikingly low. This article has three objectives to address these prior results. First, we synthesize and expand on insights into existing literature by systematically exploring the potential causes for the discrepancies in results. We reinforce previous work indicating baseline modeling may drive differences across studies and deduce that control accuracy plays a role in the major differences between experiments and simulation. Second, we discuss why the RTE metric is problematic for DR applications, discuss another proposed metric, additional energy consumption (AEC), and propose an extension, which we call uninstructed energy consumption (UEC), to evaluate DR performance. Finally, we explore the merits of different metrics using experimental data and highlight UEC's reduced sensitivity to the characteristics of the DR signal than previously proposed metrics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY2022 Filter Test for TRU Waste Drum Prototype Unit

Continuing last year’s (fiscal year 2021) work, a prototype instrument and an NPI-6 Integrated Work Document (IWD) were developed to assess the functionality of filters on transuranic waste containers (commonly called 55 Gallon ring-top drums) without requiring the removal of the drum lid. The purpose of this work is to determine the air flow and pressure characteristics associated with filter clogging, filter pressure drop at a fixed flow rate, and leakage around the lid seal. The FY22 objectives included: (A) Development of prototype device, (B) Drafting an IWD document, (C) Defining a filter clogging parameter, (D) Assessing filter damage due to over-pressure events, and (E) A path forward to obtain approval of the system safety filters in compliance with P101-16 Industrial Ventilation – non HVACR (LANL 2022).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pre-Installation Acceptance (PIA) Functional Performance of the Design Verification Test (DVT) Exploration Extra-vehicular Mobility Unit (xEMU)

In an effort that began with technology investment by NASA in a few key components during the Constellation Program and then evolved to demonstrate a packaged Portable Life Support System (PLSS) as part of the Advanced Exploration Systems (AES) Program, the next evolution of the PLSS is now a key component of the Exploration Extra-vehicular Mobility Unit (xEMU) and is assembled as a Design Verification Test (DVT) unit. The xEMU has been detailed with respect to completing a demonstration on the International Space Station (ISS) with support of units for initial lunar capability. The xEMU completed the Preliminary Design Review (PDR) with subsequent Safety Review Panel (SRP) Phase I reviews in 2019-2020. The objectives for DVT are to validate requirements, train the team, learn how to fabricate the hardware with appropriate process controls, assemble the hardware, test the hardware, determine the failure mechanisms/limits of the hardware design and buy down the most risk possible for the qualification and flight phases of the development. With completion of the assembly and initial functional testing of the DVT PLSS in laboratory ambient conditions and vacuum conditions the xEMU has progressed significantly into the DVT objectives. A key part of the test sequences for DVT and all future phases is the Pre-Installation Acceptance (PIA) functional testing which validates the performance of integrated systems including: primary thermal control, auxiliary thermal control, suit ventilation, primary oxygen, secondary oxygen, power distribution, as well as caution and warning all with respect to the applied requirements. This discussion will include an overview of the assembly, summary of the PIA functional testing, lessons learned, and corrective actions implemented moving forward into the remainder of the DVT phase for xEMU.

Colin Campbell↗

Exploration Extravehicular Mobility Unit (xEMU) Chamber B Thermal Vacuum “Suit 2” Pressure Garment System Hardware and Test Design

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation space suit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test hardware design and test methodology for the “Suit 2” Pressure Garment System (PGS) test article. The uncrewed “Suit 2” PGS test article consisted of a full PGS assembly with simulated Portable Life Support System (PLSS) functionality provided by test equipment, including a ventilation loop and two distinct thermal control loops. This paper will discuss in depth the test hardware design, including internal suit thermal boundary simulation, sensor quantity and placement, test support equipment rigs for gas flow, water flow, and power. Custom hardware designed to add additional penetrations to the suit or provide additional interfaces for sensors will also be discussed. This paper will also address the assembly and integration sequence for the test article. In addition to test hardware design, this paper will provide insights into the test methodology for this test article, including a discussion of thermal steady-state testing, simultaneous dual suit thermal vacuum testing, and hazard mitigation and controls.

xEMU↗

Short Exploration Extravehicular Mobility Unit Testing Setup: Evaluation Under Realistic Pressure and Thermal Conditions

The purpose of Short Exploration Extravehicular Mobility Unit (SxEMU) thermal vacuum testing was to verify the functionality of the Design Verification Testing (DVT) prototype xEMU (SxEMU for this test) at vacuum pressures and extreme space and lunar surface temperature conditions. The SxEMU Thermal Vacuum Test was the culmination of the DVT xEMU project. This paper’s focus is on the pre-Extravehicular Activity (EVA) test setup, and general performance of the SxEMU Portable Life Support Subsystem (xPLSS), with focus on the performance of the Primary Oxygen Assembly (POA) and Secondary Oxygen Assembly (SOA), including Secondary Oxygen Regulator (SOR) takeover and the POA and SOA low-setpoint change inhibit. The initial pre-EVA test preparation included recharging the batteries and replenishing consumables, including test-system water, oxygen assemblies (with gaseous nitrogen), and the integrated thermal loops, including the Feedwater Supply Assemblies. xPLSS functionality testing included carbon dioxide (CO2) removal via the Rapid Cycle Amine swingbed system, thermal loop temperature control, and monitoring of suit ventilation loop pressure, temperature, and CO2 percentages. Testing evaluated automatic takeover of suit pressure control by the SOR after the primary oxygen supply is depleted. The Primary Oxygen Regulator and SOR low-setpoint change inhibit function prevents the crewmember from inadvertently setting the primary regulator to a low pressure setpoint during an EVA.

xPLSS↗

Data Analysis Approach for Large Data Volumes in a Connected Community

Recent advancements within smart neighborhoods where utilities are enabling automatic control of appliances such as heating, ventilation, and air conditioning (HVAC) and water heater (WH) systems are providing new opportunities to minimize energy costs through reduced peak load. This requires systematic collection, storage, management, and in-memory processing of large volumes of streaming data for fast performance. In this paper, we propose a multi-tier layered IoT software framework that enables effective descriptive and predictive data analysis for understanding live operation of the neighborhood, fault identification, and future opportunities for further optimization of load curves. We then demonstrate how we achieve live situational awareness of the connected neighborhood through a suite of visualization components. Finally, we discuss a few analytic dashboards that address questions such as peak load reductions obtained due to optimization, customer preference for automatic control of appliances (do they override the automatic control of HVAC?, etc.). 1 1 This manuscript has been authored by UT-Battelle, LLC under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a nonexclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan).

Chinthavali, Supriya↗

Smart indoor air venting system

A venting system in accordance with the present disclosure includes a ventilation fan and one or more sensors coupled to the ventilation fan. The ventilation fan is positioned to vent air from an indoor environment. The sensors are positioned to monitor conditions in the indoor environment and selectively operate the ventilation fan to condition air in the indoor environment.

Moore, Mike↗

Simple Wins: Driving Effective Implementation of Energy Efficiency Projects

Small- and medium-sized manufacturers (SMMs) in the United States, making up over 98% of manufacturing firms, account for 48.3% of the sector’s energy consumption. Despite access to energy assessments and technical resources, such as those from the US Department of Energy’s Better Plants program and Industrial Training and Assessment Centers, implementation rates for identified energy-saving measures remain lower than expectations, averaging 47%. Some barriers were identified by other researchers as limited workforce capacity, inadequate training, and time constraints hinder progress. This article studied the development of customized checklists together with the energy assessment report as a practical solution to improve implementation rates for energy efficiency projects among SMMs. The framework for the checklists was grounded in five principles: short, precise, actionable, relevant, and codeveloped (SPARC). A case study of a 500,000-squarefoot SMM demonstrates how tailored checklists targeting significant energy users—such as heating, ventilating and air conditioning (HVAC), lighting, and compressed air systems for this facility—can simplify the process for staff to do facility walkthroughs to monitor best practices and track the progress of energy efficiency project implementation.

Guo, Wei [Oak Ridge National Laboratory (ORNL), Oa↗

Evaluation of exercise-respiratory system modifications and preliminary respiratory-circulatory system integration scheme

The respiratory control system, functioning as an independent system, is presented with modifications of the exercise subroutine. These modifications illustrate an improved control of ventilation rates and arterial and compartmental gas tensions. A very elementary approach to describing the interactions of the respiratory and circulatory system is presented.

Gallagher, R. R.↗

Human Systems Integration: Managing Risk in Anesthesia

The practice of anesthesia relies on clinicians’ ability to safely manage increasingly complex equipment. Devices such as ventilators, drug infusion pumps, and physiologic monitors use sophisticated algorithms to deliver care, but most clinicians are only trained to manage automated systems during normal operation. Few if any receive training on how to manage system failures. Although manufacturers are required to consult with human factors engineers as part of the equipment design process, most pieces of equipment are ultimately brought to market without extensive input from clinicians. Systems in the operating room can be as simple as an oxygen tank, or as complex as a multi-institutional healthcare organization. Humans are also a complex system, and play a critical role in the domains of operations, design, fabrication, maintenance, repair, and ultimately, dismantling and closeout. HSI seeks to provide a means for advocating the human side of the system. Human Systems Integration (HSI) is the cross disciplinary process used as part of the Systems Engineering process to reduce risk in systems. HSI professionals consider the human, hardware, and software elements of system design to optimize system performance and improve safety. HSI professionals work in domains of study that include training, management, human factors engineering, safety, and occupational health, among others. This article discusses the role of systems in the practice of anesthesia, and how consideration of the human during all phases of the system life cycle helps manage risks and promote a better patient outcome.

Human Factors↗

Flexible Fabrics with High Thermal Conductivity for Advanced Spacesuits

This paper describes the effort and accomplishments for developing flexible fabrics with high thermal conductivity (FFHTC) for spacesuits to improve thermal performance, lower weight and reduce complexity. Commercial and additional space exploration applications that require substantial performance enhancements in removal and transport of heat away from equipment as well as from the human body can benefit from this technology. Improvements in thermal conductivity were achieved through the use of modified polymers containing thermally conductive additives. The objective of the FFHTC effort is to significantly improve the thermal conductivity of the liquid cooled ventilation garment by improving the thermal conductivity of the subcomponents (i.e., fabric and plastic tubes). This paper presents the initial system modeling studies, including a detailed liquid cooling garment model incorporated into the Wissler human thermal regulatory model, to quantify the necessary improvements in thermal conductivity and garment geometries needed to affect system performance. In addition, preliminary results of thermal conductivity improvements of the polymer components of the liquid cooled ventilation garment are presented. By improving thermal garment performance, major technology drivers will be addressed for lightweight, high thermal conductivity, flexible materials for spacesuits that are strategic technical challenges of the Exploration

Trevino, Luis A.↗

International Space Station (ISS) Bacterial Filter Elements (BFEs): Filter Efficiency and Pressure Testing of Returned Units

The air revitalization system aboard the International Space Station (ISS) provides the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation due to the microgravity environment in Low Earth Orbit (LEO). The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Adsorption (HEPA) media filters deployed at multiple locations in each U.S. Segment module; these filters are referred to as Bacterial Filter Elements, or BFEs. These filters see a replacement interval, as part of maintenance, of 2-5 years dependent on location in the ISS. In this work, we present particulate removal efficiency, pressure drop, and leak test results for a sample set of 8 BFEs returned from the ISS after filter replacement. The results can potentially be utilized by the ISS Program to ascertain whether the present replacement interval can be maintained or extended to balance the on-ground filter inventory with extension of the lifetime of ISS beyond 2024. These results can also provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

Filtration↗

Modeling of a Two-Phase Jet Pump with Phase Change, Shocks and Temperature-Dependent Properties

One of the primary motivations behind this work is the attempt to understand the physics of a two-phase jet pump which constitutes part of a flow boiling test facility at NASA-Marshall. The flow boiling apparatus is intended to provide data necessary to design highly efficient two-phase thermal control systems for aerospace applications. The facility will also be capable of testing alternative refrigerants and evaluate their performance using various heat exchangers with enhanced surfaces. The test facility is also intended for use in evaluating single-phase performance of systems currently using CFC refrigerants. Literature dealing with jet pumps is abundant and covers a very wide array of application areas. Example application areas include vacuum pumps which are used in the food industry, power station work, and the chemical industry; ejector systems which have applications in the aircraft industry as cabin ventilators and for purposes of jet thrust augmentation; jet pumps which are used in the oil industry for oil well pumping; and steam-jet ejector refrigeration, to just name a few. Examples of work relevant to this investigation includes those of Fairuzov and Bredikhin (1995). While past researchers have been able to model the two-phase flow jet pump using the one-dimensional assumption with no shock waves and no phase change, there is no research known to the author apart from that of Anand (1992) who was able to account for condensation shocks. Thus, one of the objectives of this work is to model the dynamics of fluid interaction between a two-phase primary fluid and a subcooled liquid secondary fluid which is being injected employing atomizing spray injectors. The model developed accounts for phase transformations due to expansion, compression, and mixing. It also accounts for shock waves developing in the different parts of the jet pump as well as temperature and pressure dependencies of the fluid properties for both the primary two-phase mixture and the secondary subcooled liquid. The research effort on which this document partly reports described a relatively simple model capable of describing the performance of a two-phase flow jet pump. The model is based on the isentropic homogeneous expansion/compression hypothesis and is capable of fully incorporating the effects of shocks in both the mixing chamber and the throat/diffuser parts of the pump. The physical system chosen is identical to that experimentally tested by Fairuzov and Bredikhin (1995) and should therefore be relatively easy to validate.

Sherif, S. A.↗

Final Seismic Shake Table Test Plan

The Spent Fuel Waste Disposition (SFWD) program is planning to conduct a full-scale seismic shake table test on the dry storage systems of spent nuclear fuel (SNF) to close the gap related to seismic loads on fuel assemblies in dry storage systems. This test will allow for quantifying the strains and accelerations on surrogate fuel assembly hardware and cladding during earthquakes of different magnitudes and frequency content. Full-scale testing is needed because a dry storage system is a complex and highly nonlinear system making it hard to predict (model) the responses to seismic excitations. The non-linearity arises from the multiple spatial gaps in the system – between fuel rods and the basket, between the basket and dry storage canister, between the dry storage canister and the storage cask (overpack), and ventilation gaps. The non-linearities pose significant limitations on the value of tests with scaled systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control Oriented Model of Cabin-HVAC System in a Long-Haul Trucks for Energy Management Applications

Super Truck II is a 48V mild hybrid class 8 truck with an all auxiliary loads powered purely by the battery pack. Electric Heating Ventilation and Air Conditioning (HVAC) load is the most prominent battery load during the hotel period, when the truck driver is resting inside the sleeper. For the PACCAR Super Truck II (ST-II) project a 48 V battery system provides the required power during the hotel period. A cabin-HVAC model estimates the electric load on the 48V battery system, allowing the control system to implement an efficient energy management strategy that avoids engine idling during the hotel period. The thermal model accounts for the sun load due to the time of day and the geographic location of the truck during the hotel period. The cabin-HVAC model has two parts. First, a grey box model with two heat exchangers (Condenser and Evaporator) working in unison with refrigerant mass flow rate as an input and HVAC load as an output. Second, a two-node cabin model formulated to estimate the cabin temperature as a function of the Global Horizontal Irradiance (GHI), HVAC load and ambient temperature. The models are calibrated using experimental cabin-HVAC system data as for long-haul class 8 truck (e.g. ST-II). Here, the model simulations show that the overall Root Mean Square Error (RMSE) value of 0.4°C between the experimental and simulated cabin temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated fault detection and diagnosis of airflow and refrigerant charge faults in residential HVAC systems using IoT-enabled measurements

While automated fault detection and diagnosis (AFDD) in residential heating, ventilation, and air-conditioning (HVAC) using smart thermostat data is gaining increasing attention in recent times, it still requires in-depth investigation for market adoption, especially with real-life data. Furthermore, this paper proposes an Internet of Things (IoT) - based approach that adds a smart sensor to the smart thermostat data to carry out AFDD. The approach uses a model which predicts enthalpy change across the evaporator and compares the prediction to the measured enthalpy change. Deviations which exceed analytically determined thresholds then signal faults in the HVAC system. The faults detected are either installation related or degradation related. Experimental tests were carried out in four homes located in Norman, Oklahoma. From the tests, installation issues like indoor/outdoor mismatch were detected in two homes, while a 30% low charge and low indoor airflow rate were detected in one home. The results show that the proposed AFDD algorithm was able to successfully detect two prevalent faults, namely low indoor airflow and low refrigerant charge. Unlike most of the smart thermostat-based approaches, the proposed IoT-based approach can detect and diagnose both faults but only require one additional sensor which is provided by smart thermostat manufacturers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Management of Grid-Interactive Efficient Buildings via Safe Reinforcement Learning

Reinforcement learning (RL)-based methods have achieved significant success in managing grid-interactive efficient buildings (GEBs). However, RL does not carry intrinsic guarantees of constraint satisfaction, which may lead to severe safety consequences. Besides, in GEB control applications, most existing safe RL approaches rely only on the regularisation parameters in neural networks or penalty of rewards, which often encounter challenges with parameter tuning and lead to catastrophic constraint violations. To provide enforced safety guarantees in controlling GEBs, this paper designs a physics-inspired safe RL method whose decision-making is enhanced through safe interaction with the environment. Different energy resources in GEBs are optimally managed to minimize energy costs and maximize customer comfort. The proposed approach can achieve strict constraint guarantees based on prior knowledge of a set of developed hard steady-state rules. Simulations on the optimal management of GEBs, including heating, ventilation, and air conditioning (HVAC), solar photovoltaics, and energy storage systems, demonstrate the effectiveness of the proposed approach.

Huo, Xiang↗