Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRASOUND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Design of Zeolitic Imidazolate Framework-8-Functionalized Capacitive Micromachined Ultrasound Transducer Gravimetric Sensors for Gas and Hydrocarbon Vapor Detection

A capacitive micromachined ultrasound transducer (CMUT) was engineered and functionalized with zeolitic imidazolate framework-8 (ZIF-8) dispersed in a photoresist AZ1512HS (AZ) matrix to function as a gravimetric gas sensor. The sensor response was recorded in the presence of nitrogen, argon, carbon dioxide, and methane gases as well as water, acetylene, a propane/butane mixture, n-hexane, gasoline, and diesel vapors. The photoresist matrix alone was found to have a negligible response to all the gases and vapors, except for water vapor. No visible difference in sensor response was detected when switching from nitrogen to methane gas. However, a strong shift in the sensor resonance frequency was observed when exposed to higher hydrocarbons, ranging from 1 kHz for acetylene to 7.5 kHz for gasoline. Even longer-chain hydrocarbons, specifically kerosene and more so diesel, had a significantly reduced sensor frequency shift compared with gasoline. Sensors functionalized with a thin film of AZ+ZIF-8 demonstrated higher sensitivity in their response to a hydrocarbon molecular mass than without functionalization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Some aspects of using ultrasounds to improve sulfurous mineral flotation technology

The results are discussed which were obtained with a new method of desorption of collector reagents connected with improving the selectivity of the flotation of copper and lead concentrate through the action of ultrasounds. Analysis of the results obtained by treating copper and lead concentrate in an ultraacoustic field indicates an increase in the copper content of the copper concentrate, of the lead content in the lead concentrate and, at the same time, a reduction in the lead of the copper concentrate.

Mihu, V. P.↗

Cracking and reformation of saturated hydrocarbons by ultrasound in the presence of water

The exposure of saturated hydrocarbons to ultrasound (800 kHz, 6 W/sq cm) in the presence of water results in: (1) cleavage of the carbon chain, producing saturated and unsaturated hydrocarbons with a lower number of carbons than the initial hydrocarbon (cracking); and (2) recombination after cleavage, producing saturated and unsaturated hydrocarbons with a higher number of carbons than the initial hydrocarbon (reformation). The addition of argon facilitates these phenomena. The effects are attributed to a homolytic (radical) mechanism occurring within the cavitation bubbles under the effects of microsparks.

Prudhomme, M. R. O.↗

Improvement of electric characteristics of lead accumulators under the action of ultrasounds

Results are given of experiments conducted in order to improve the electric characteristics of lead accumulators by ultrasonic irradiation of their electrolytes. The experimental results discussed complete the research conducted on static Le2, Le3 and D. Quaiser cells whose solutions were irradiated beforehand with ultrasounds of the frequency of 1 MHz. It is demonstrated that the discharge currents and capacitances of the investigated cells keep to higher values even 1 year after ultrasonic irradiation of the electrolyte. The experimental results are discussed.

Mihu, V. P.↗

Influence of ultrasounds on electrolytic polishing

On the basis of study of the electrolytic polishing of metal pieces, the following conclusions can be drawn: (1) Utilization of ultrasonically irradiated electrolytes in the electrolytic polishing of copper and steel pieces leads to enhanced polishing quality. (2) Polishing time for the reference pieces was twice as long as for the test pieces. (3) The chemical attack exerted on the surface of the test pieces in order to get the structure of the respective metal lasted less than half as long and yielded superior qualitative results in the copper as well as in the OT 60-2 steel test pieces polished with ultrasonically irradiated electrolytes. (4) The utilization of higher polishing current densities can be explained by the fact that the cavitational effect that arises in the electrolyte owing to ultrasounds contributes to an increase in the solution's electrical conductivity and elimination of gases from the electrolyte.

Gavrila, I.↗

Influence of moisture content on the velocity of ultrasounds in black poplar wood

Correlations among the longitudinal, radial and tangential velocities of ultrasounds in black poplar on the one hand and among these magnitudes and the wood's moisture content on the other hand are presented. Mathematical equations approximating these correlations are given, and the influence of moisture content on the elastic constants of wood is discussed. The possibility of using ultrasonic methods in automating the wood drying process and in testing the quality and homogeneity of wood is pointed out.

Bucar, V.↗

Tissue identification by ultrasound

The ultrasonic properties of animal and human soft tissue were measured over the frequency range of 1.5 to 10.0 MHz. The method employed a swept-frequency, coherent technique known as time delay spectrometry. Measurements of attenuation versus frequency on liver, backfat, kidney, pancreas, spleen, breast, and other tissue were made. Considerable attention was paid to tissue handling and in determining the effects of fixing on the attenuation of ultrasound in the tissue.

Lecroissette, D. H.↗

Signal processing in ultrasound

Signal is the term used to denote the characteristic in the time or frequency domain of the probing energy of the system. Processing of this signal in diagnostic ultrasound occurs as the signal travels through the ultrasonic and electrical sections of the apparatus. The paper discusses current signal processing methods, postreception processing, display devices, real-time imaging, and quantitative measurements in noninvasive cardiology. The possibility of using deconvolution in a single transducer system is examined, and some future developments using digital techniques are outlined.

Le Croissette, D. H.↗

Clinical ophthalmic ultrasound improvements

The use of digital synthetic aperture techniques to obtain high resolution ultrasound images of eye and orbit was proposed. The parameters of the switched array configuration to reduce data collection time to a few milliseconds to avoid eye motion problems in the eye itself were established. An assessment of the effects of eye motion on the performance of the system was obtained. The principles of synthetic techniques are discussed. Likely applications are considered.

Garrison, J. B.↗

Computer-generated 3D ultrasound images of the carotid artery

A method is under development to measure carotid artery lesions from a computer-generated three-dimensional ultrasound image. For each image, the position of the transducer in six coordinates (x, y, z, azimuth, elevation, and roll) is recorded and used to position each B-mode picture element in its proper spatial position in a three-dimensional memory array. After all B-mode images have been assembled in the memory, the three-dimensional image is filtered and resampled to produce a new series of parallel-plane two-dimensional images from which arterial boundaries are determined using edge tracking methods.

Selzer, Robert H.↗

An analysis of temperature-induced errors for an ultrasound distance measuring system

The presentation of research is provided in the following five chapters. Chapter 2 presents the necessary background information and definitions for general work with ultrasound and acoustics. It also discusses the basis for errors in the slant range measurements. Chapter 3 presents a method of problem solution and an analysis of the sensitivity of the equations to slant range measurement errors. It also presents various methods by which the error in the slant range measurements can be reduced to improve overall measurement accuracy. Chapter 4 provides a description of a type of experiment used to test the analytical solution and provides a discussion of its results. Chapter 5 discusses the setup of a prototype collision avoidance system, discusses its accuracy, and demonstrates various methods of improving the accuracy along with the improvements' ramifications. Finally, Chapter 6 provides a summary of the work and a discussion of conclusions drawn from it. Additionally, suggestions for further research are made to improve upon what has been presented here.

Wenger, David Paul↗

Transcranial Doppler ultrasound and the etiology of neurologic decompression sickness during altitude decompression

The presence of gas bubbles in the arterial circulation can occur from iatrogenic mishaps, cardiopulmonary bypass devices, or following decompression, e.g., in deep-sea or SCUBA diving or in astronauts during extravehicular activities (EVA). We have examined the pathophysiology of neurological decompression sickness in human subjects who developed a large number of small gas bubbles in the right side of the heart as a result of hypobaric exposures. In one case, gas bubbles were detected in the middle cerebral artery (MCA) and the subject developed neurological symptoms; a 'resting' patent foramen ovalae (PFO) was found upon saline contrast echocardiography. A PFO was also detected in another individual who developed Spencer Grade 4 precordial Doppler ultrasound bubbles, but no evidence was seen of arterialization of bubbles upon insonation of either the MCA or common carotid artery. The reason for this difference in the behavior of intracardiac bubbles in these two individuals is not known. To date, we have not found evidence of right-to-left shunting of bubbles through pulmonary vasculature. The volume of gas bubbles present following decompression is examined and compared with the number arising from saline contrast injection. The estimates are comparable.

Norfleet, W. T.↗