Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

In situ measurement of interfacial tension of Fe-S and Fe-P liquids under high pressure using X-ray radiography and tomography techniques

Interfacial tension is one of the most important properties of the liquid iron alloy that controls the core formation process in the early history of the Earth and planets. In this study, we made high-pressure X-ray radiography and micro-tomography measurements to determine the interfacial tension between liquid iron alloys and silicate melt using the sessile drop method. The measured interfacial tension of liquid Fe-S decreased significantly (802-112 mN/m) with increasing sulphur content (0-40 at%) at 1.5 GPa. In contrast, the phosphorus content of Fe had an almost negligible effect on the interfacial tension of liquid iron. These tendencies in the effects of light elements are consistent with those measured at ambient pressure. Our results suggest that the effect of sulphur content on the interfacial tension of liquid Fe-S (690 mN/m reduction with the addition of 40 at% S) is large compared with the effect of temperature (~273 mN/m reduction with an increase of 200 K). The three-dimensional structure of liquid Fe-S was obtained at ~2 GPa and 1373-1873 K with a high-pressure tomography technique. The Fe-S droplet was quite homogeneous when evaluated in a slice of the three-dimensional image.

36 MATERIALS SCIENCE↗

High Resolution Neutron Radiography and Tomography of Hydrided Zircaloy-4 Cladding Materials

Neutron radiography for hydrogen analysis was performed with several Zircaloy-4 cladding samples with controlled hydrogen concentrations up to 1100 ppm. Hydrogen charging was performed in a process tube that was heated to facilitate hydrogen absorption by the metal. A correlation between the hydrogen concentration in the hydrided tubes and the neutron intensity was established, by which hydrogen content can be determined precisely in a small area (55 m x 55 m). Radiography analysis was also performed to evaluate the heating rate and its correlation with the hydrogen distribution through hydrided materials. In addition to radiography analysis, tomography experiments were performed on Zircaloy-4 tube samples to study the local hydrogen distribution. Through tomography analysis a 3D reconstruction of the tube was evaluated in which an uneven hydrogen distribution in the circumferential direction can be observed.

hydride↗

From pixels to patterns: Coupling Optical Coherence Tomography and machine learning for monitoring coastal wetland root systems

Coastal wetlands are crucial in shoreline stabilization, carbon sequestration, and storm protection. Yet, due to limitations in traditional destructive sampling techniques, the belowground biomass (live root mass) and necromass (dead and decaying roots) remain difficult to assess in coastal wetlands, limiting our understanding on coastal resilience, nutrient cycling, and soil structure. This study employs Optical Coherence Tomography (OCT) as a high-resolution imaging technique to analyze root biomass and necromass in the Terrebonne Basin, Louisiana. A Random Forest (RF) model was developed to classify root health states based on OCT-derived features, achieving an accuracy of 70% in distinguishing live from dead root segments. The results demonstrate that OCT, combined with ML, offers a promising novel approach to root analysis, providing fine-scale insights into root morphology and decay patterns that are not easily captured by conventional methods. This research lays the foundation for future integration of OCT with complementary imaging modalities such as X-ray Computed Tomography (XCT) and advanced ML algorithms to enhance classification accuracy and scalability. Future work aims to expand the dataset diversity across different wetland types and apply the methodology for large-scale, repeatable assessments of root biomass turnover and accumulation, with important implications for wetland monitoring, conservation, and restoration under changing environmental conditions.

AI/ML↗

Boosting Noise2Inverse via enhanced model selection for denoising computed tomography data

Synchrotron-based x-ray tomographic imaging enables the examination of the internal structure of materials at high spatial and temporal resolution. Experimental constraints can impose dose and time limits on the measurements, introducing a higher level of noise and artifacts in the reconstructed images. Deep learning has emerged as a powerful tool to remove noise from reconstructed images. Recently, the Noise2Inverse method was designed specifically for denoising reconstructed images without requiring paired noisy and clean images. This method creates multiple statistically independent reconstructions used to pair the data in which training involves transforming one reconstruction into the other, and vice versa. Originally designed to be used after a fixed number of epochs, we see in practice that this approach may not produce the optimal model and may unnecessarily waste computational resources. Therefore, we propose an alternative method of identifying the best model during training that aligns with the Noise2Inverse method. During validation, we compare the model output of the multiple reconstructions among each other. We hypothesize that the best model is the one that produces images with the highest similarity, implying a convergence in the predicted material properties and absorption values. To compare model outputs, we consider the absolute error, square error, structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), and cosine similarity. We evaluate our method on two simulated tomography datasets and two, real-world, low-contrast, high-energy x-ray tomography datasets. We show our approach is more effective at determining the best model, up to an increase of 12.50% and 12.53% in SSIM and PSNR, respectively, while only requiring a fifth of the training time compared to the original approach.

CT↗

Breaking the Crowther limit: Combining depth-sectioning and tilt tomography for high-resolution, wide-field 3D reconstructions

To date, high-resolution (<1 nm) imaging of extended objects in three-dimensions (3D) has not been possible. A restriction known as the Crowther criterion forces a tradeoff between object size and resolution for 3D reconstructions by tomography. Further, the sub-Angstrom resolution of aberration-corrected electron microscopes is accompanied by a greatly diminished depth of field, causing regions of larger specimens (>6 nm) to appear blurred or missing. We demonstrate a three-dimensional imaging method that overcomes both these limits by combining through-focal depth sectioning and traditional tilt-series tomography to reconstruct extended objects, with high-resolution, in all three dimensions. The large convergence angle in aberration corrected instruments now becomes a benefit and not a hindrance to higher quality reconstructions. A through-focal reconstruction over a 390 nm 3D carbon support containing over 100 dealloyed and nanoporous PtCu catalyst particles revealed with sub-nanometer detail the extensive and connected interior pore structure that is created by the dealloying instability.

3D imaging↗

Simultaneous neutron and X-ray tomography for visualization of graphite electrode degradation in fast-charged lithium-ion batteries

Advanced battery characterization using neutron and X-ray-based imaging modalities is crucial to reveal fundamental degradation modes of lithium-ion batteries (LIBs). Taking advantage of the sensitivity of neutrons to some low-Z (Li) and X-rays to high-Z materials (Cu), here we demonstrate the viability of simultaneous neutron and X-ray tomography (NeXT) as a non-destructive imaging platform for ex-situ 3D visualization of graphite electrode degradation following extreme fast charging (XFC). In addition, we underscore the benefits of the simultaneous of NeXT by combining the neutron and X-ray tomography data from the same sample location for material identification and segmentation of one pristine and two XFC-cycled graphite electrodes (9C charge for 450 cycles). Our ex-situ results and methodology development pave the way for the design of NeXT-friendly LIB geometries that will allow operando and/or in-situ 3D visualization of electrode degradation during XFC.

25 ENERGY STORAGE↗

The Future of Atom Probe Tomography

The dream of the microscopy and materials science communities is to see, identify, accurately locate, and determine the fundamental physical properties of every atom in a specimen. With this knowledge together with modern computer models and simulations, a full understanding of the properties of a material can be determined. This fundamental knowledge leads to the design and development of more advanced materials for solving the needs of society. The technique of atom probe tomography is the closest to fulfilling this dream but is still significantly short of the goal. The future of atomic probe tomography, and the prospects for achieving this ultimate goal are outlined.

36 MATERIALS SCIENCE↗

Understanding Fragmentation of Organic Small Molecules in Atom Probe Tomography

In atom probe tomography of molecular organic materials, field ionization of either entire molecules or molecular fragments can occur, but the mechanism governing this behavior was not previously understood. This work explains when a doubly ionized small molecule organic material is expected to undergo fragmentation. Here, we find that multiple detection events arising from post-ionization fragmentation of a parent molecular dication into two daughter ions is well explained by the free energy and geometries of the molecules computed using density functional theory. Of the systems studied, exergonic free energies for formation of the daughter ions, smaller activation energies for dissociation, and increases in bond length are all found to be quantitative predictors for ion fragmentation. This work expands the applicability of atom probe tomography to organic materials by increasing the fundamental understanding of processes occurring during this analysis technique.

36 MATERIALS SCIENCE↗

A Bismuth Metal–Organic Framework as a Contrast Agent for X-ray Computed Tomography

A new bismuth metal–organic framework (MOF), bismuth-NU901 (Bi-NU-901), featuring the scu topology and a pore with a diameter of ~11 Å, was solvothermally synthesized, and its use as an X-ray computed tomography (CT) contrast agent was tested. X-ray CT is a common diagnostic method used in the medical field. Inside the body, contrast media enhance the distinction between tissues and organs of similar density. Bi-NU-901 consists of eight connected Bi 6 nodes and tetratopic 1,3,5,8-( p -benzoate)pyrene linkers (TBAPy). Numerous material characterization studies including powder X-ray diffraction (PXRD), scanning transmission electron microscopy (STEM), and DFT pore size distribution support the scu structure. Additionally, given the framework’s high density of nontoxic heavy atoms, Bi-NU-901 was evaluated as an X-ray computed tomography (CT) agent. Importantly, in vitro studies revealed this new bismuth MOF demonstrates p7 times better contrast intensity compared to a zirconium MOF featuring the same topology and ~14 times better contrast than a commercially available CT contrast agent. Furthermore these results suggest bismuth MOFs may be promising CT contrast agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Thermal Plumbing System of Stromboli Volcano, Aeolian Islands (Italy) Inferred From Electrical Conductivity and Induced Polarization Tomography

Abstract We performed the first 3D island‐scale tomography of the electrical conductivity of Stromboli volcano (Aeolian Islands, Italy) using 2D acquisition lines (37.2 km) and a total of 18,880 measurements and 2,402 unique electrode locations. This 3D data set was inverted using a Gauss‐Newton algorithm, parallel‐processing on an unstructured tetrahedral mesh containing 678,420 finite‐element nodes and 3,580,145 elements to account for the topography of the volcanic island. The tomogram exhibits a conductive body (10 −2 –1.0 S m −1 ) consistent with the location of CO 2 and temperature anomalies observed at the ground surface. It corresponds to the hydrothermal system with high electrical conductivity associated with alteration. In order to confirm this interpretation, a 2.5D large‐scale induced polarization tomography was performed crossing the volcano. The joint interpretation of the conductivity and normalized chargeability is done with a petrophysical model previously tested and verified at both shield‐ and strato‐volcanoes. This model implies that alteration (through the effect of the cation exchange capacity associated with clay minerals and zeolites) plays a strong role in both controlling the electrical conductivity and normalized chargeability at Stromboli volcano. A temperature tomogram, derived from the geoelectrical measurements, is consistent with surface temperature anomalies and the Very Long Period (VLP) seismicity related to the mild‐explosive activity. This survey displays at 600 m a.s.l. a lateral shift in the highest temperature location, also corresponding to the source of VLP seismicity. Structural boundaries have a major role in the hottest hydrothermal fluids rising below the active crater terrace of Stromboli volcano.

58 GEOSCIENCES↗

Crystallographic Texture, Structure, and Stress Transmission in Nugget Sandstone Examined With X‐Ray Tomography and Diffraction Microscopy

Subsurface processes in sandstones are controlled by porosity, permeability, and deformation mechanisms, all of which are controlled by a complex interplay of crystallographic rock texture, structure, and micromechanics. Texture, structure, and micromechanics have historically been studied using optical and electron microscopy of thin-sections. Here, we employed a new combination of in situ X-ray tomography and ray diffraction microscopy to study crystallographic texture, structure, and grain stresses in 3D. We examined these features in a sample of Nugget sandstone, a sandstone constituting hydrocarbon reservoirs across the American West. Our aims are threefold. First, we demonstrate the utility of X-ray diffraction microscopy probes for revealing texture, structure, and stress transmission in 3D. Second, we apply these techniques to Nugget sandstone and discuss findings in the context of prior work. Third, we study grain stress tensor evolution during mechanical compression to examine whether their heterogeneity and orientation evolution reflect that of inter-particle forces in granular materials. Our results show: (a) larger grains featured higher intra-granular misorientations, possibly from an increased prevalence of cements; (b) pores closed parallel to the loading direction and opened normal to loading; (c) grain stresses featured heterogeneity and orientations similar to inter-particle forces in non-cohesive granular materials; (d) grains featured compressive stresses in the loading direction and tensile stresses orthogonal to the loading direction, the latter resisting sample dilation and grain separation. Our work demonstrates the first known application of multi-modal X-ray tomography and diffraction microscopy to sandstone, providing new 3D insight into the nature of quartz cement and stress evolution.

high energy diffraction microscopy↗

4D imaging of lithium-batteries using correlative neutron and X-ray tomography with a virtual unrolling technique

The temporally and spatially resolved tracking of lithium intercalation and electrode degradation processes are crucial for detecting and understanding performance losses during the operation of lithium-batteries. Here, high-throughput X-ray computed tomography has enabled the identification of mechanical degradation processes in a commercial Li/MnO 2 primary battery and the indirect tracking of lithium diffusion; furthermore, complementary neutron computed tomography has identified the direct lithium diffusion process and the electrode wetting by the electrolyte. Virtual electrode unrolling techniques provide a deeper view inside the electrode layers and are used to detect minor fluctuations which are difficult to observe using conventional three dimensional rendering tools. Moreover, the 'unrolling' provides a platform for correlating multi-modal image data which is expected to find wider application in battery science and engineering to study diverse effects e.g. electrode degradation or lithium diffusion blocking during battery cycling.

25 ENERGY STORAGE↗

Extracellular filaments revealed by affinity capture cryogenic-electron tomography

Cryogenic-electron tomography (cryo-ET) has provided an unprecedented glimpse into the nanoscale architecture of cells by combining cryogenic preservation of biological structures with electron tomography. Micropatterning of extracellular matrix proteins is increasingly used as a method to prepare adherent cell types for cryo-ET as it promotes optimal positioning of cells and subcellular regions of interest for vitrification, cryo-focused ion beam (cryo-FIB) milling, and data acquisition. Here we demonstrate a micropatterning workflow for capturing minimally adherent cell types, human T cells and Jurkat cells, for cryo-FIB and cryo-ET. Our affinity capture system facilitated the nanoscale imaging of Jurkat cells, revealing extracellular filamentous structures. It improved workflow efficiency by consistently producing grids with a sufficient number of well-positioned cells for an entire cryo-FIB session. Affinity capture can be extended to facilitate high-resolution imaging of other adherent and non-adherent cell types with cryo-ET.

Biochemistry↗

Momentum informed muon scattering tomography for monitoring spent nuclear fuels in dry storage cask

Development of an effective monitoring method for spent nuclear fuel (SNF) in a dry storage cask (DSC) is important to meet the increasing demand for dry storage investigations. The DSC investigation should provide information about the quantity of stored SNF, and quality assurance of materials should be possible without opening the cask. However, traditional nondestructive examination (NDE) methods such as x-rays are difficult to deploy for DSC investigation because a typical DSC is intentionally designed to shield against radiation. To address this challenge, cosmic ray muons (CRMs) are used as an alternative NDE radiation probe because they can easily penetrate an entire DSC system; however, a wide application of muons is often hindered due to the naturally low CRM flux (~10 4 muons/m 2 /min). This paper introduces a newly proposed imaging algorithm, momentum-informed muon scattering tomography (MMST) , and presents how a limitation of the current muon scattering tomography technique has been addressed by measuring muon momentum. To demonstrate its functionality, a commercial DSC with 24 pressurized light water reactor fuel assemblies (FAs) and the MMST system were designed in GEANT4. Three noticeable improvements were observed for MMST system as a DSC investigation tool: (1) a signal stabilization, (2) an enhanced capability to differentiate various materials, and (3) statistically increased precision to identify and locate missing FAs. The results show that MMST improves the investigation accuracy from 79 to 98% when one FA is missing and 51% to 88% when one-half FA is missing. The advancement of the NDE technique using CRM for DSC verification is expected to resolve long-standing problems in increasing demand for DSC inspections and nuclear security.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model-based iterative reconstruction with adaptive regularization for artifact reduction in electron tomography

Obtaining high-quality 3D reconstructions from electron tomography of crystalline particles embedded in lighter support elements is crucial for various material systems such as catalysts for fuel cell applications. However, significant challenges arise due to the limited tilt range, sparse and low signal-to-noise ratio of the measurements. In addition, small metal particles can cause strong streaking and shading artifacts in the 3D reconstructions when using conventional reconstruction algorithms due to the presence of Bragg diffraction and the large scattering cross-section difference between the materials of the particles and the background support regions. These artifacts lead to errors in the downstream characterization affecting extraction of critical features such as the size of the metal particles, their distribution and the volume of the lighter support regions. In this paper, we present a two-stage algorithm based on metal artifact reduction, utilizing model-based iterative reconstruction methods with adaptive adjustment of regularization parameters. Our approach yields high-quality 3D reconstructions compared to traditional algorithms, accurately capturing both the metal particles as well as the background support. We demonstrate the effectiveness of our algorithm through simulated and experimental bright-field electron tomography data, showing significant improvements in reconstruction quality compared to traditional methods.

97 MATHEMATICS AND COMPUTING↗

High resolution gamma ray tomography scanner for flow measurement and non-destructive testing applications

We report on the development of a high resolution gamma ray tomography scanner that is operated with a Cs-137 isotopic source at 662 keV gamma photon energy and achieves a spatial image resolution of 0.2 line pairs/mm at 10% modulation transfer function for noncollimated detectors. It is primarily intended for the scientific study of flow regimes and phase fraction distributions in fuel element assemblies, chemical reactors, pipelines, and hydrodynamic machines. Furthermore, it is applicable to nondestructive testing of larger radiologically dense objects. The radiation detector is based on advanced avalanche photodiode technology in conjunction with lutetium yttrium orthosilicate scintillation crystals. The detector arc comprises 320 single detector elements which are operated in pulse counting mode. For measurements at fixed vessels or plant components, we built a computed tomography scanner gantry that comprises rotational and translational stages, power supply via slip rings, and data communication to the measurement personal computer via wireless local area network.

36 MATERIALS SCIENCE↗

Monochromatic Neutron Tomography Using 1-D PSD Detector at Low Flux Research Reactor

This paper describes the monochromatic neutron tomography experiment using the 1-D Position Sensitive Neutron Detector (PSD) located at Nuclear Malaysia TRIGA MARK II Research reactor. Experimental work was performed using monochromatic neutron source from beryllium filter and HOPG crystal monochromator. The principal main aim of this experiment was to test the detector efficiency, image reconstruction algorithm and the usage of 0.5 nm monochromatic neutrons for the neutron tomography setup. Other objective includes gathering important parameters and features to characterize the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward Rapid Unattended X-ray Tomography of Large Planar Samples at 50-nm Resolution

X-ray tomography at sub-50 nm resolution of small areas ({approx}15 {mu}mx15 {mu}m) are routinely performed with both laboratory and synchrotron sources. Optics and detectors for laboratory systems have been optimized to approach the theoretical efficiency limit. Limited by the availability of relatively low-brightness laboratory X-ray sources, exposure times for 3-D data sets at 50 nm resolution are still many hours up to a full day. However, for bright synchrotron sources, the use of these optimized imaging systems results in extremely short exposure times, approaching live-camera speeds at the Advanced Photon Source at Argonne National Laboratory near Chicago in the US These speeds make it possible to acquire a full tomographic dataset at 50 nm resolution in less than a minute of true X-ray exposure time. However, limits in the control and positioning system lead to large overhead that results in typical exposure times of {approx}15 min currently.We present our work on the reduction and elimination of system overhead and toward complete automation of the data acquisition process. The enhancements underway are primarily to boost the scanning rate, sample positioning speed, and illumination homogeneity to performance levels necessary for unattended tomography of large areas (many mm{sup 2} in size). We present first results on this ongoing project.

77 NANOSCIENCE AND NANOTECHNOLOGY↗