Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

High-Temperature Probe Station Developed to Characterize Microwave Devices Through 500 C

A photograph and a block diagram of the high-temperature probe station are shown. The system consists of the ceramic heater mounted on a NASA shuttle tile insulator, a direct current power supply, a personal-computer-based data acquisition and temperature controller, microwave probes, a microscope, and a network analyzer. The ability to perform microwave tests at high temperatures is becoming necessary. There is now a need for sensors and communication circuits that can operate at 500 C and above for aircraft engine development and monitoring during flight. To address this need, researchers have fabricated devices using wide bandgap semiconductors such as SiC with targeted operating temperatures of 500 to 600 C. However, the microwave properties of these devices often change drastically with temperature, so any designs that are intended to be used in such an environment must be characterized at high temperatures. For some reliability, lifetime, and direct-current testing, the device under test can be packaged and characterized in an oven. However, for RF and microwave measurements, it is usually not possible to establish a calibrated reference plane at the device terminals within a package. In addition, the characteristics of the package would vary over a 500 C temperature range, and this would have to be accounted for when the data were analyzed. A high temperature probe station allows circuits and devices to be characterized through on wafer measurements across a broad temperature range with known reference plane. The conventional, commercially available thermal wafer-probe stations that are used to evaluate microwave devices across a controlled temperature range have a typical upper limit of 200 C. Standalone thermal heating chucks are available with an extended upper temperature range of 300 to 400 C. To effectively characterize devices at temperatures up to and surpassing 500 C, Glenn researchers developed a custom probe station. In the past, custom probe stations have been developed to test devices under other extreme environments, such as cryogenic temperatures as low as 37 K. Similarly, this custom probe station was specifically modified for high-temperature use. It allows devices to be measured quickly and flexibly, without the use of wire bonds and test fixtures. The probe station is shown making scattering parameter measurements from 1 to 50 GHz with a Hewlett-Packard 8510C Network Analyzer. There is a half-wafer of silicon directly on top of the heater to provide a uniform heated platform for our sample. A quarter wafer of silicon carbide forms the substrate for our test circuit of several transmission lines.

Downey, Alan N.↗

Ultrastable environment control for the NEID spectrometer: design and performance demonstration

Two key areas of emphasis in contemporary experimental exoplanet science are the detailed characterization of transiting terrestrial planets and the search for Earth analog planets to be targeted by future imaging missions. Both of these pursuits are dependent on an order-of-magnitude improvement in the measurement of stellar radial velocities (RV), setting a requirement on single-measurement instrumental uncertainty of order 10 cm∕s. Achieving such extraordinary precision on a high-resolution spectrometer requires thermomechanically stabilizing the instrument to unprecedented levels. We describe the environment control system (ECS) of the NEID spectrometer, which will be commissioned on the 3.5-m WIYN Telescope at Kitt Peak National Observatory in 2019, and has a performance specification of on-sky RV precision <50 cm/s. Because NEID’s optical table and mounts are made from aluminum, which has a high coefficient of thermal expansion, sub-milliKelvin temperature control is especially critical. NEID inherits its ECS from that of the Habitable-Zone Planet Finder (HPF), but with modifications for improved performance and operation near room temperature. Our full-system stability test shows the NEID system exceeds the already impressive performance of HPF, maintaining vacuum pressures below 10(exp −6) Torr and a root mean square (RMS) temperature stability better than 0.4 mK over 30 days. Our ECS design is fully open-source; the design of our temperature-controlled vacuum chamber has already been made public, and here we release the electrical schematics for our custom temperature monitoring and control system.

Paul Robertson↗

Dryness controls temperature-optimized gross primary productivity across vegetation types

Temperature response of gross primary productivity (GPP) is a well-known property of ecosystem, but GPP at the optimum temperature (GPP_T opt ) has not been fully discussed. Our understanding of how GPP_T opt responds to warming and water availability is highly limited. Here, in this study, we analyzed data at 326 globally distributed eddy covariance sites (79°N-37°S), to identify controlling factors of GPP_T opt . Although GPP_T opt was significantly influenced by soil moisture, global solar radiation, mean annual temperature, and vapor pressure deficit in a non-linear pattern (R 2 = 0.47), the direction and magnitude of these climate variables’ effects on GPP_T opt depend on the dryness index (DI), a ratio of potential evapotranspiration to precipitation. The spatial pattern showed that soil moisture did not affect GPP_T opt across energy-limited sites with DI < 1 while dominated GPP_T opt across water-limited sites with DI >1. The temporal pattern showed that GPP_T opt was lowered by warming or low precipitation in water-limited sites while energy-limited sites tended to maintain a stable GPP_T opt regardless of changes in air temperature. Vegetation types in humid climates tended to have higher GPP_T opt and were more likely to benefit from a warmer climate since it was not restricted by water conditions. This study highlights that the response of GPP_T opt to global warming depends on the dryness conditions, which explains the nonlinear control of water and temperature over GPP_T opt . Our finding is essential to realistic prediction of terrestrial carbon uptake under future climate and vegetation conditions.

54 ENVIRONMENTAL SCIENCES↗

COVID 19 vaccine distribution solution to the last mile challenge: Experimental and simulation studies of ultra-low temperature refrigeration system

Most COVID-19 vaccines require ambient temperature control for transportation and storage. Both Pfizer and Moderna vaccines are based on mRNA and lipid nanoparticles requiring low temperature storage. The Pfizer vaccine requires ultra-low temperature storage (between -80 °C and -60 °C), while the Moderna vaccine requires -30 °C storage. Pfizer has designed a reusable package for transportation and storage that can keep the vaccine at the target temperature for 10 days. However, the last stage of distribution is quite challenging, especially for rural or suburban areas, where local towns, pharmacy chains and hospitals may not have the infrastructure required to store the vaccine. Also, the need for a large amount of ultra-low temperature refrigeration equipment in a short time period creates tremendous pressure on the equipment suppliers. In addition, there is limited data available to address ancillary challenges of the distribution framework for both transportation and storage stages. As such, there is a need for a quick, effective, secure, and safe solution to mitigate the challenges faced by vaccine distribution logistics. The study proposes an effective, secure, and safe ultra-low temperature refrigeration solution to resolve the vaccine distribution last mile challenge. Furthermore, the approach is to utilize commercially available products, such as refrigeration container units, and retrofit them to meet the vaccine storage temperature requirement. Both experimental and simulation studies are conducted to evaluate the technical merits of this solution with the ability to control temperature at -30 °C or -70 °C as part of the last mile supply chain for vaccine candidates.

60 APPLIED LIFE SCIENCES↗

Multitarget control models for building thermal comfort and indoor air quality - A critical review

The control techniques in buildings contribute significantly to thermal comfort and indoor air quality (IAQ). However, the gaps are existing for multitarget controls considering both thermal comfort and IAQ. They are: (1) both experimental and modeling control studies were conducted for thermal comfort, focusing on temperature and humidity. (2) All three (physical, grey-box, black-box) modeling approaches were investigated for temperature control. (3) Physical and grey-box modeling approach were adopted for humidity control. (4) physical models were developed for VOCs and CO2 control. (5) grey-box and black-box models were lacking for VOCs and CO2. (6) Multi-target controls were lacking for temperature, humidity and CO2s. (7) Limited studies are available for multi-target controls for temperature, humidity, and VOCs. (8) Multi-target controls are not available yet for temperature, humidity, VOCs, and CO2.

42 ENGINEERING↗

Performance of a continuously rotating half-wave plate on the POLARBEAR telescope

A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes parameters, I, Q and U, thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector pairs. We focus on the implementation of CRHWPs in large aperture telescopes (i.e. the primary mirror is larger than the current maximum half-wave plate diameter of ~0.5 m), where the CRHWP can be placed between the primary mirror and focal plane. In this configuration, one needs to address the intensity to polarization (I→P) leakage of the optics, which becomes a source of 1/f noise and also causes differential gain systematics that arise from CMB temperature fluctuations. In this paper, we present the performance of a CRHWP installed in the {\scshape Polarbear} experiment, which employs a Gregorian telescope with a 2.5 m primary illumination pattern. The CRHWP is placed near the prime focus between the primary and secondary mirrors. We find that the I→P leakage is larger than the expectation from the physical properties of our primary mirror, resulting in a 1/f knee of 100 mHz. The excess leakage could be due to imperfections in the detector system, i.e. detector non-linearity in the responsivity and time-constant. We demonstrate, however, that by subtracting the leakage correlated with the intensity signal, the 1/f noise knee frequency is reduced to 32 mHz (ℓ ~ 39 for our scan strategy), which is very promising to probe the primordial B-mode signal. We also discuss methods for further noise subtraction in future projects where the precise temperature control of instrumental components and the leakage reduction will play a key role.

79 ASTRONOMY AND ASTROPHYSICS↗

A study of elevated temperature testing techniques for the fatigue behavior of PMCS: Application to T650-35/AMB21

An experimental study was conducted to investigate the mechanical behavior of a T650-35/AMB21 eight-harness satin weave polymer composite system. Emphasis was placed on the development and refinement of techniques used in elevated temperature uniaxial PMC testing. Issues such as specimen design, gripping, strain measurement, and temperature control and measurement were addressed. Quasi-static tensile and fatigue properties (R(sub sigma) = 0.1) were examined at room and elevated temperatures. Stiffness degradation and strain accumulation during fatigue cycling were recorded to monitor damage progression and provide insight for future analytical modeling efforts. Accomplishments included an untabbed dog-bone specimen design which consistently failed in the gage section, accurate temperature control and assessment, and continuous in-situ strain measurement capability during fatigue loading at elevated temperatures. Finally, strain accumulation and stiffness degradation during fatigue cycling appeared to be good indicators of damage progression.

Gyekenyesi, Andrew L.↗

Laboratory Astrophysics using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

When we last reported, our new microcalorimeter system was being prepared for delivery and permanent installation at the NIST EBIT. This occurred in June 2003 and check-out with the internal calibration source and EBIT plasma x-rays took place over the next several months during which time we modified several component parts to improve the performance. These changes included: 1) A redesign of the x-ray calibration source from a direct electron impact source to one that irradiates the microcalorimeter with fluorescent x-rays. The resulting calibration lines are free of bremsstrahlung background; 2) The microcalorimeter electronic circuit has been significantly improved to ensure long-term stability for the lengthy upcoming runs of the EBIT. Both the preamplifier feedback resistors were changed and the first stage of the preamplifier redesigned. Several photos of the new system are shown in slides 3 and 4. This microcalorimeter spectrometer only requires helium refills every three days (as opposed to every 24 hours in our earlier system) and it will hold a temperature of 65 mK for up to 48 hours (as opposed to 8 hours). Consequently, the efficiency of data acquisition will improve dramatically. The first x-ray spectra of the new calibration source made with the 4-element detector array is shown. An example of the temperature control capabilities of the ADR for a 23 hour interval is shown. The horizontal line shows the temperature stability (about +/- 3 micro kelvin). There are a few short-lived heating excursions caused by technical staff working on the EBIT machine simultaneously. During actual experimental runs these are absent. This temporal profile was interrupted to test additional components of the system; otherwise, the temperature controlling would have continued for another 24 hours.

Silver, Eric↗

A system to control CO2 in O2 concentrations in aqueous media (Year 2 Report)

Per the Statement of Work, the following tasks were outlined for completion in Year 2: 1). Testing, modification, and optimization of the system. 2). Addition of oxygen manipulation and monitoring. 3). Expansion of CO2 bubbling/pH reduction system to include oxygen addition/removal and temperature control. 4). Investigate alkalinity modification by the microbial cultures and its impact on the carbonate chemistry control of the system. 5).Deliverable: Seawater chemistry and temperature control and monitoring system for microbial culture studies under present and future ocean conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrostatic levitation facility optimized for neutron diffraction studies of high temperature liquids at a spallation neutron source

Neutron diffraction studies of metallic liquids provide valuable information about inherent topological and chemical ordering on multiple length scales as well as insight into dynamical processes at the level of a few atoms. However, there exist very few facilities in the world that allow such studies to be made of reactive metallic liquids in a containerless environment, and these are designed for use at reactor-based neutron sources. We present an electrostatic levitation facility, NESL (for Neutron ElectroStatic Levitator), which takes advantage of the enhanced capabilities and increased neutron flux available at spallation neutron sources (SNSs). NESL enables high quality elastic and inelastic neutron scattering experiments to be made of reactive metallic and other liquids in the equilibrium and supercooled temperature regime. The apparatus is comprised of a high vacuum chamber, external and internal neutron collimation optics, and a sample exchange mechanism that allows up to 30 samples to be processed between chamber openings. Two heating lasers allow excellent sample temperature homogeneity, even for samples approaching 500 mg, and an automated temperature control system allows isothermal measurements to be conducted for times approaching 2 h in the liquid state, with variations in the average sample temperature of less than 0.5%. To demonstrate the capabilities of the facility for elastic scattering studies of liquids, a high quality total structure factor for Zr{sub 64}Ni{sub 36} measured slightly above the liquidus temperature is presented from experiments conducted on the nanoscale-ordered materials diffractometer (NOMAD) beam line at the SNS after only 30 min of acquisition time for a small sample (∼100 mg)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Terra and Aqua MODIS Thermal Emissive Bands On-Orbit Calibration and Performance

Since launch, the Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on the Terra and Aqua spacecraft have operated successfully for more than 14 and 12 years, respectively. A key instrument for National Aeronautics and Space Administration Earth Observing System missions, MODIS was designed to make continuous observations for studies of Earth's land, ocean, and atmospheric properties and to extend existing data records from heritage Earth observing sensors. The 16 thermal emissive bands (TEBs) (3.75-14.24 micrometers) are calibrated on orbit using a temperature controlled blackbody (BB). Both Terra and Aqua MODIS BBs have displayed minimal drift over the mission lifetime, and the seasonal variations of the BB temperature are extremely small in Aqua MODIS. The long-term gain and noise equivalent difference in temperature performance of the 160 TEB detectors on both MODIS instruments have been well behaved and generally very stable. Small but noticeable variations of Aqua MODIS bands 33-36 (13.34-14.24 micrometer) response in recent years are primarily due to loss of temperature control margin of its passive cryoradiative cooler. As a result, fixed calibration coefficients, previously used by bands when the BB temperature is above their saturation temperatures, are replaced by the focal-plane-temperature-dependent calibration coefficients. This paper presents an overview of the MODIS TEB calibration, the on-orbit performance, and the challenging issues likely to impact the instruments as they continue operating well past their designed lifetime of six years.

TEBs↗

Anomalous structural recovery in the near glass transition range in a polymer glass: Data revisited in light of temperature variability in vacuum oven‐based experiments*

Abstract There is considerable interest in data reported by Cangialosi et al. [Cangialosi, D., Boucher, V. M., Alegría, A., & Colmenero, J. (2013). Physical Review Letters , 111 (9), 095701] that purportedly showed unusual irregular responses in the isothermal structural recovery behavior of glasses because the observation challenges the general view of the dynamics being smooth functions of time as observed in extensive dilatometric experiments by Kovacs [Kovacs, A. J. (1964). In Fortschritte der Hochpolymeren‐Forschung , 3 , 394–507. Springer, Berlin, Heidelberg.] in the 1960s. The reported data show an apparent two mechanism structural (enthalpy) recovery at aging temperatures ranging from 6 to 17 K below which is also controversial as it could not be reproduced in work from Koh and Simon [Koh, Y. P., & Simon, S. L. (2013). Macromolecules , 46(14), 5815–5821.] where a second plateau observed in the enthalpy loss curve was not reproduced in nearly 1‐year‐long experiments at 15 K below . Therefore, it is important to determine what might be possible reasons for the apparent non‐smooth relaxations. Here, we examine the possibility that the poor temperature control of a typical vacuum oven could explain the anomalous results. We used the Tool–Narayanaswamy–Moynihan (TNM) model of structural recovery to calculate the effect of typical vacuum oven temperature variation on the structural recovery of polystyrene and find that we can reproduce the reported experimental results. The issue of temperature control using a vacuum oven is discussed, and data from thermocouple measurements of temperature at various locations inside a vacuum oven are shown.

36 MATERIALS SCIENCE↗

Thermodynamic Measurements Using the Knudsen Cell Technique

The Knudsen cell technique has been used for over a century and is a valuable tool for measurement of vapor pressures and thermodynamic properties. It is based on a small enclosure (~1 cm long x 1 cm diameter) in which a condensed phase/vapor equilibria can be established. A small (<1 mm) orifice on the cell allows sampling of the vapor via a variety of techniques including weight loss, torsion effusion, target collection, and mass spectrometry. Many excellent measurements based on these methods have been reported. However in order to obtain reliable measurements, a variety of factors must be considered. They include proper cell material selection, accurate and uniform temperature control and measurement, and proper sampling of the vapor. Each of these factors are discussed in detail in this chapter. Typically these studies are conducted at high temperatures and it is a challenge to select an inert container material. Recommended materials are discussed and in some cases the container may be used as part of the system under study. Temperature control and measurement is perhaps the most important issue. In most systems, the furnace must be compact yet there can be no temperature gradient in the cell. Temperatures are measured with either a thermocouple or pyrometer and the relative advantages of each are discussed. Sampling method considerations depend on the particular technique. It is essential that all of the vapor or a representative portion of the vapor be sampled. The distribution of the effusate from a Knudsen cell is discussed and sampling positions discussed. Mass spectrometry is often used to study the effusing vapor and the relations between ion current and vapor pressure are discussed.

mass spectrometry↗

Fabrication of silicon-tipped fiber-optic temperature sensors using aerogel-assisted glass soldering with precise laser heating

We demonstrate the fabrication of fiber-optic Fabry–Perot interferometer (FPI) temperature sensors by bonding a small silicon diaphragm to the tip of an optical fiber using low melting point glass powders heated by a 980 nm laser on an aerogel substrate. The heating laser is delivered to the silicon FPI using an optical fiber, while the silicon temperature is being monitored using a 1550 nm white-light system, providing localized heating with precise temperature control. The use of an aerogel substrate greatly improves the heating efficiency by reducing the thermal loss of the bonding parts to the ambient environment. A desirable temperature for bonding can be achieved with relatively small heating laser power. The bonding process is carried out in an open space at room temperature for convenient optical alignment. The precise temperature control ensures minimum perturbation to the optical alignment and no induced thermal damage to the optical parts during the bonding process. For demonstration, we fabricated a low-finesse and high-finesse silicon FPI sensor and characterized their measurement resolution and temperature capability. The results show that the fabrication method has a good potential for high-precision fabrication of fiber-optic sensors.

Sheng, Qiwen↗

A pumped two-phase cooling system for spacecraft

A pumped, two-phase heat-transport system is being developed for possible use for temperature control of scientific instruments on future NASA missions. As compared to a single-phase system, this two-phase system can maintain tighter temperature control with less pumping power. A laboratory model of the system has been built and tested. The measured heat transfer coefficients were approximately the same as in heat pipes, 220 Btu/hr-sq ft-F, as compared to 25 Btu/hr-sq ft-F for single-phase liquid flow. Heat shearing between experiments has been demonstrated wherein vapor generated in the cold plate of an active experiment was condensed in a cold, unheated experiment. System stability has been observed. However, additional development is needed. The use of non-azeotropic mixtures of coolants appears especially promising as a simple way to determine exit quality and thus control the flow rates to prevent dryout.

Ollendorf, S.↗

Substrate availability and not thermal acclimation controls microbial temperature sensitivity response to long-term warming

Microbes are responsible for cycling carbon (C) through soils, and predicted changes in soil C stocks under climate change are highly sensitive to shifts in the mechanisms assumed to control the microbial physiological response to warming. Two mechanisms have been suggested to explain the long-term warming impact on microbial physiology: microbial thermal acclimation and changes in the quantity and quality of substrates available for microbial metabolism. Yet studies disentangling these two mechanisms are lacking. To resolve the drivers of changes in microbial physiology in response to long-term warming, we sampled soils from 13- and 28-year-old soil warming experiments in different seasons. We performed short-term laboratory incubations across a range of temperatures to measure the relationships between temperature sensitivity of physiology (growth, respiration, carbon use efficiency, and extracellular enzyme activity) and the chemical composition of soil organic matter. We observed apparent thermal acclimation of microbial respiration, but only in summer, when warming had exacerbated the seasonally-induced, already small dissolved organic matter pools. Irrespective of warming, greater quantity and quality of soil carbon increased the extracellular enzymatic pool and its temperature sensitivity. We propose that fresh litter input into the system seasonally cancels apparent thermal acclimation of C-cycling processes to decadal warming. Our findings reveal that long-term warming has indirectly affected microbial physiology via reduced C availability in this system, implying that earth system models including these negative feedbacks may be best suited to describe long-term warming effects on these soils.

59 BASIC BIOLOGICAL SCIENCES↗