Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEST METHODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r)

Purpose: The authors designed data, methods, and metrics that can serve as a standard, independent of any software package, to evaluate dose-volume histogram (DVH) calculation accuracy and detect limitations. The authors use simple geometrical objects at different orientations combined with dose grids of varying spatial resolution with linear 1D dose gradients; when combined, ground truth DVH curves can be calculated analytically in closed form to serve as the absolute standards. Methods: DICOM RT structure sets containing a small sphere, cylinder, and cone were created programmatically with axial plane spacing varying from 0.2 to 3 mm. Cylinders and cones were modeled in two different orientations with respect to the IEC 1217 Y axis. The contours were designed to stringently but methodically test voxelation methods required for DVH. Synthetic RT dose files were generated with 1D linear dose gradient and with grid resolution varying from 0.4 to 3 mm. Two commercial DVH algorithms—PINNACLE (Philips Radiation Oncology Systems) and PlanIQ (Sun Nuclear Corp.)—were tested against analytical values using custom, noncommercial analysis software. In Test 1, axial contour spacing was constant at 0.2 mm while dose grid resolution varied. In Tests 2 and 3, the dose grid resolution was matched to varying subsampled axial contours with spacing of 1, 2, and 3 mm, and difference analysis and metrics were employed: (1) histograms of the accuracy of various DVH parameters (total volume, D{sub max}, D{sub min}, and doses to % volume: D99, D95, D5, D1, D0.03 cm{sup 3}) and (2) volume errors extracted along the DVH curves were generated and summarized in tabular and graphical forms. Results: In Test 1, PINNACLE produced 52 deviations (15%) while PlanIQ produced 5 (1.5%). In Test 2, PINNACLE and PlanIQ differed from analytical by >3% in 93 (36%) and 18 (7%) times, respectively. Excluding D{sub min} and D{sub max} as least clinically relevant would result in 32 (15%) vs 5 (2%) scored deviations for PINNACLE vs PlanIQ in Test 1, while Test 2 would yield 53 (25%) vs 17 (8%). In Test 3, statistical analyses of volume errors extracted continuously along the curves show PINNACLE to have more errors and higher variability (relative to PlanIQ), primarily due to PINNACLE’s lack of sufficient 3D grid supersampling. Another major driver for PINNACLE errors is an inconsistency in implementation of the “end-capping”; the additional volume resulting from expanding superior and inferior contours halfway to the next slice is included in the total volume calculation, but dose voxels in this expanded volume are excluded from the DVH. PlanIQ had fewer deviations, and most were associated with a rotated cylinder modeled by rectangular axial contours; for coarser axial spacing, the limited number of cross-sectional rectangles hinders the ability to render the true structure volume. Conclusions: The method is applicable to any DVH-calculating software capable of importing DICOM RT structure set and dose objects (the authors’ examples are available for download). It includes a collection of tests that probe the design of the DVH algorithm, measure its accuracy, and identify failure modes. Merits and applicability of each test are discussed.

60 APPLIED LIFE SCIENCES↗

Radiation thermometer size-of-source effect testing using aperture

Size-of-source effect is an important attribute of any radiation thermometer. The effects of this attribute may be quantified in a number of different ways to include field-of-view, distance ratio, or size-of-source effect. These parameters provide needed information for the user of a radiation thermometer, as they aid in determining whether the measured object is large enough for adequate radiation thermometry measurement. Just as important, these parameters provide needed information for calibration. This information helps to determine calibration geometry, and it is needed for calibration uncertainty determination. For determination of size-of-source effect, there are a limited number of test methods furnished by the standards available today. The test methods available may be cumbersome to perform due to the cost of the required equipment and the time needed to set-up and perform the test. Other methods have been proposed. This paper discusses one such method. This method uses a circular aperture such as that used in radiation thermometer calibration. It describes the method both theoretically and mechanically. It then discusses testing done to verify this method comparing the results to those obtained while performing steps in current standards. Finally, based on this testing, the basis for a new standard test method is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Out-of-plane properties

This paper summarizes three areas of research which were performed to characterize out-of-plane properties of composite materials. In the first investigation, a series of tests was run to characterize the through-the-thickness tensile strength for a variety of composites that included 2D braids, 2D and 3D weaves, and prepreg tapes. A new test method based on a curved beam was evaluated. Failures were significantly different between the 2D materials and the 3D weaves. The 2D materials delaminated between layers due to out-of-plane tensile stresses while the 3D weaves failed due to the formation of radial cracks between the surface plies caused by high circumferential stresses along the inner radius. The strength of the 2D textile composites did not increase relative to the tapes. Final failure in the 3D weaves was caused by a circumferential crack similar to the 2D materials and occurred at a lower bending moment than in other materials. The early failures in the 3D weaves were caused by radial crack formation rather than a low through-the-thickness strength. The second investigation focused on the development of a standard impact test method to measure impact damage resistance. The only impact tests that currently exist are compression after impact (CAI) tests which incorporate elements of both damage resistance and damage tolerance. A new impact test method is under development which uses a quasi-static indentation (QSI) test to directly measure damage resistance. Damage resistance is quantified in terms of the contact force to produce a unit of damage where a metric for damage may be area in C-scan, depth of residual dent , penetration, damage growth, etc. A final draft of an impact standard that uses a QSI test method will be presented to the ASTM Impact Task Group on impact. In the third investigation, the impact damage resistance behavior of a variety of textile materials was studied using the QSI test method. In this study, the force where large damage initiates was measured and the delamination size as a function of force was determined. The force to initiate large damage was significantly lower in braids and weaves. The delamination diameter - impact forace relationship was quanitfied using a damage resistance parameter, Q(*), which related delamination diameter to imapct force over a range of delamination sizes. Using this Q(*) parameter to rate the materials, the stitched uniweaves, toughened epoxy tapes, and through-the-thickness orthogonal interlock weave were the most damage resistant.

Jackson, Wade C.↗

Lessons Learned from Performance Testing of Humans in Spacesuits in Simulated Reduced Gravity

Introduction: The overarching objective of the Integrated Suit Test (IST) series is to evaluate suited human performance using reduced-gravity analogs and learn what aspects of an EVA suit system affect human performance. For this objective to be successfully achieved, the testing methodology should be valid and reproducible, and the partial-gravity simulations must be as accurate and realistic as possible. Objectives: To highlight some of the key lessons learned about partial-gravity analogs and testing methodology, and to suggest considerations for optimizing the effectiveness and quality of results of future tests. Methods: Performance testing of suited and unsuited subjects was undertaken in different reduced-gravity analogs including the Space Vehicle Mockup Facility s Partial Gravity Simulator (POGO), parabolic flight on the C-9 aircraft, underwater environments including NASA s Extreme Environment Mission Operations (NEEMO) and the Neutral Buoyancy Lab (NBL), and in field analogs including Desert Research and Technology Studies (RATS), the Haughton Mars Project (HMP), and the JSC Rock Pile. Subjects performed level walking, incline/decline walking, running, shoveling, picking up and transferring rocks, kneeling/standing, and task boards. Lessons Learned Analogs: No single analog will properly simulate all aspects of the true partial-gravity environment. The POGO is an ideal environment from the standpoint that there are no time limits or significant volumetric constraints, but it does have several limitations. It allows only 2 translational degrees of freedom (DOF) and applies true partial-gravity offload only through the subject s center of gravity (CG). Also, when a subject is doing non-stationary tasks, significant overhead inertia from the lift column seems to have a negative impact on performance. Parabolic flight allows full translational and rotational DOF and applies offload to all parts of the body, but the simulation lasts less than 30 seconds. When this is coupled with the volumetric constraints of the plane, both task selection and data collection options are significantly limited. The underwater environments also allow all 6 DOF and allow off-loading to be applied throughout the body, but the data collection capabilities are limited to little more than subjective ratings. In addition, water drag negatively affects performance of tasks requiring dynamic motion. Field analogs provide the ability to simulate lunar terrain and more realistic mission-like objectives, but all of them operate at 1-g, so suited human performance testing generally must utilize a reduced-mass or "mockup" suit, depending on study objectives. In general, the ground-based overhead-suspension partial-gravity analogs like POGO allow the most diverse data collection methods possible while still simulating partial gravity. However, as currently designed, the POGO has significant limitations. Design of the Active Response Gravity Offload System (ARGOS) has begun and is focusing on adding full x,y,z translational DOF, improved offload accuracy, increased lift capacity, and active control of the x and y axes to minimize offload system inertia. Additionally, a new gimbal is being designed to reduce mass and inertia and to be able to work with different suits, as the current gimbal only supports suited testing with the Mark III Technology Demonstrator Suit (MKIII).

Norcross, Jason R.↗

An improved method for quantitatively measuring antifouling coating performance using a mussel single thread tensile adhesion test

Surface biofouling reduces the efficiency and lifespan of equipment across many industries. The development of high-performance antifouling surfaces, such as foul release coatings, benefits from test methods that can quickly identify superior antifouling surfaces in the laboratory during material development. Existing test methods poorly discriminate between different foul release coatings. Here is presented a method to assess the ability of surfaces to resist mussel adhesion using a quantitative, controlled single thread adhesion test (STAT) method, allowing for meaningful comparisons between low adhesion foul release surfaces. This method provides greater accuracy and finer resolution than push-based mussel shear adhesion methods without the difficulties associated with mussel size, thread attachment angle, or harming the mussels. The single thread tensile method is demonstrated on a variety of standard and high-performance coatings, and it is shown that the method detects differentiation between commercial foul release coatings that could not be resolved using other methods.

42 ENGINEERING↗

A seamless acquisition digital storage oscilloscope with three-dimensional waveform display

In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Origami-based Composite Space Structures

The main objective of my internship was working on developing a new type of deployable composite for space structures and new method of deployment via use of origami, composites, UV curing resins, and shape memory polymers. My role in the project was to collect an initial literature survey on the subject including origami, the history of deployable space structures, previous issues and problems faced in the field, previous and current research being done on the structural aspect as well as the materials aspect of the subject. I presented this information to our team, where we discussed and determined our research focus and project design specs. We have been making or will make decisions on the project’s purpose, material, origami type, manufacturing method, and testing methods. I am now in charge of the protype design as we enter the design stage of our research. I am using PTC Creo software to design the structural aspects of the first protype so that we can begin small scale testing. I will perform data analysis in order to review the results with our team, so we can make the next design decisions regarding changes or iterations of the design. We hope to renew this project in the next fiscal year in order to increase the TRL of the project so that it can eventually be used in multiple functions in space such as the construction of lunar habitats. In just my brief time with NASA, I have gained so much personally and professionally. I developed my ability to search through and narrow down information when doing research. In the weekly meetings I practiced presenting information to my peers and superiors, and, just as importantly, discussing and adapting to what we were learning. I acquired experience in using technology to my advantage including remote work, new software like PTC Creo, NASA archives, and connecting with others beyond my team to gain help. I enjoyed the immense resource of knowledge that my mentors had to offer, and that they gave me a large amount of responsibility in this research. I truly felt like I was contributing to something bigger than myself and understood how directly I was involved in NASA’s work. This internship has further cemented my love for space and desire to continue in the field. I have a better understanding of the research and development process and am now considering joining a research lab with my university next year.

Composite↗

A Preliminary Investigation of a New Method for Testing Aerofoils in Free Flight

This report is a description of a new method of testing aerofoils in free flight devised by the National Advisory Committee for Aeronautics. The method consists in lowering below a flying airplane a large inverted aerofoil on three small steel wires in such a way that the lift on the aerofoil always keeps the wires tight. The resultant force is measured by the tension in the wires, and the direction of the resultant by the amount the wing trails backwards. A test was made on an aerofoil of the N.A.C.A. #64 section, 6 ft. in span and the results are compared with a similar section tested in the wind tunnel. This investigation indicates that by the use of suitable recording apparatus aerofoils may be accurately and conveniently tested at a Reynolds number, a velocity and a degree of turbulence, comparable with that on the full-sized airplane. Satisfactory experiments were also made in trailing a sphere and a streamlined body on single wires.

Norton, F H↗

JOINT RIGIDITY ASSESSMENT WITH PIEZOELECTRIC WAFERS AND ACOUSTIC WAVES

There has been an interest in the development of rapid deployment satellites. In a modular satellite design, different panels of specific functions can be pre-manufactured. The satellite can then be assembled and tested just prior to deployment. Traditional vibration testing is time-consuming and expensive. An alternative test method to evaluate the connection between two plates will be proposed. The method investigated and described employs piezoelectric wafers to induce and sense lamb waves in two aluminum plates, which were joined by steel brackets to form an 'L-Style' joint. Lamb wave behavior and piezoelectric material properties will be discussed; the experimental setup and results will be presented. A set of 4 piezoelectric ceramic wafers were used alternately as source and sensor. The energy transmitted was shown to correlate with a mechanical assessment of the joint, demonstrating that this method of testing is a feasible and reliable way to inspect the rigidity of joints.

36 MATERIALS SCIENCE↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Different Approaches for Measuring Shear Fracture Appearance in Charpy Tests

In this work, different approaches for establishing shear fracture appearance (SFA) on tested Charpy specimens were assessed and compared, namely (in order of increasing expected accuracy) estimates based on characteristic forces from instrumented Charpy tests, optical measurements using image analysis software, and measurements performed with the aid of a scanning electron microscope. Comparisons between different SFA values for 129 instrumented Charpy tests currently included in the National Institute of Standards and Technology database allowed us to establish the relationships between the different available approaches and formulate recommendations for the revision of the standards ASTM E2298-18, Standard Test Method for Instrumented Impact Testing of Metallic Materials, and ISO 14556:2015, Metallic Materials — Charpy V-Notch Pendulum Impact Test — Instrumented Test Method, which currently provide four empirical correlations that can be used to estimate SFA.

36 MATERIALS SCIENCE↗

Wind Turbine Blade Test Definition of the DeWind DW90 Rotor Blade: Cooperative Research and Development Final Report, CRADA Number CRD-09-326

This CRADA was developed as a funds-in CRADA with DeWind to assess the suitability of facilities and equipment at the NWTC for performing certification blade testing on wind turbine blades made from advanced materials. DeWind produces a wind turbine blade which includes the use of high-strength and stiffness materials. NREL and DeWind had a mutual interest in defining the necessary facilities,equipment, and test methods for testing large wind turbine blades which incorporate advanced materials and adaptive structures, as the demands on test equipment and infrastructure are greater than current capabilities. Work under this CRADA would enable DeWind to verify domestic capability for certification-class static and fatigue testing, while NREL would be able to identify and developspecialized test capabilities based on the test requirements.

17 WIND ENERGY↗

Energy Efficiency and Performance Evaluation of Self-Contained, Medium Temperature, Reach-In Refrigerated Display Cases

This project was part of an effort by Commonwealth Edison Company (ComEd) to evaluate the energy and peak demand saving potential of emerging technologies in the Chicago area. This document focuses on the assessment of energy-efficient, medium-temperature, self-contained refrigerated display cases utilizing environmentally friendly refrigerants. The results of this evaluation will be considered by CLEAResult to develop a new energy efficiency rebate measure for ComEd's incentive programs. This rebate measure will become an addition to the Technical Reference Manual (TRM). In 2016, the United Nations passed the Kigali Montreal Protocol Amendment which placed restrictions on certain types of refrigerants. In compliance with this amendment, the US Environmental Protection Agency (EPA) placed a ban on the manufacture of refrigeration systems using hydrofluorocarbons including R134a starting in January 2020. Although the ban has halted manufacture, the EPA continues to allow the use of these refrigerants. Therefore, it is critical to provide incentives for replacing these refrigerants with other environmentally friendly and energy-efficient alternatives. The energy-efficient refrigerator cases evaluated here (referred to as EE Case A and B) contain environmentally-friendly refrigerants in compliance with the EPA hydrofluorocarbon ban. These consist of natural refrigerant propane (R290), and HFC drop-in hydrofluoroolefin R513a, respectively. These cases also contain other energy-efficient components including efficient lighting, more robust evaporator and condenser fans and different-sized heat exchangers. EE Case A is also built with materials that better insulate the case, which improves energy efficiency. To ascertain the energy efficiency contribution of these design components, the consumption of the evaporator and condenser fan motors, compressor, and lighting/controller were evaluated individually. The medium-temperature, self-contained reach-in refrigerated display case was selected due to its widespread use in convenience stores and small supermarkets. Self-contained refrigeration has also seen increased use in restaurants due to curbside pickup during the COVID-19 pandemic. For this study, the refrigerated display cases' performance was evaluated in a controlled environmental chamber at representative indoor dry-bulb and humidity conditions found in supermarkets within ComEd's service territory climate zone. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 method of testing. However, modifications to the ANSI/ASHRAE test methodology were implemented to better represent customer operation of the units. In addition to the indoor supermarket conditions, the cases were also evaluated at the "upper target," or environmental conditions used in ANSI/ASHRAE 72-2018. The case total power and case components were metered to obtain their daily power (kW) and energy consumption(kWh). The cases were filled with thermal filler mass to replicate thermal mass of product loading. Additionally, product simulators were used to provide product temperature information. Door actuators were mounted to each of the cases' three doors to replicate regular door openings and effects of shopper traffic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmentally Safe, Large Volume Utilization Applications for Gasification Byproducts

Samples of gasification by-products produced at Polk Station and Eastman Chemical were obtained and characterized. Bulk samples were prepared for utilization studies by screening at the appropriate size fractions where char and vitreous frit distinctly partitioned. Vitreous frit was concentrated in the +20 mesh fraction while char predominated in the -20+100 mesh fraction. The vitreous frit component derived from each gasifier slag source was evaluated for use as a pozzolan and as aggregate. Pozzolan testing required grinding the frit to very fine sizes which required a minimum of 60 kwhr/ton. Grinding studies showed that the energy requirement for grinding the Polk slag were slightly higher than for the Eastman slag. Fine-ground slag from both gasifiers showed pozzoalnic activity in mortar cube testing and met the ASTM C618 strength requirements after only 3 days. Pozzolanic activity was further examined using British Standard 196-5, and results suggest that the Polk slag was more reactive than the Eastman slag. Neither aggregate showed significant potential for undergoing alkali-silica reactions when used as concrete aggregate with ASTM test method 1260. Testing was conducted to evaluate the use of the frit product as a component of cement kiln feed. The clinker produced was comprised primarily of the desirable components Ca{sub 3}SiO{sub 5} and Ca{sub 2}SiO{sub 4} after raw ingredient proportions were adjusted to reduce the amount of free lime present in the clinker. A mobile processing plant was designed to produce 100 tons of carbon from the Eastman slag to conduct evaluations for use as recycle fuel. The processing plant was mounted on a trailer and hauled to the site for use. Two product stockpiles were generated; the frit stockpile contained 5% LOI while the carbon stockpile contained 62% LOI. The products were used to conduct recycle fuel tests. A processing plant was designed to separate the slag produced at Eastman into 3 usable products. The coarse frit has been shown to be suitable for use as clinker feed for producing Portland cement. The intermediate-size product is enriched in carbon (58-62% C) and may be used as recycle fuel either in the gasifier or in a PC boiler. The fines product contains 30-40% C and may also be used as a recycle gasifier fuel, as is presently done at TECO's Polk Station, however, due to gasifier operating requirements for the production of syngas, this is not feasible at Eastman.

01 COAL, LIGNITE, AND PEAT↗

Residential Forced Air System Cabinet Leakage and Blower Performance

This project evaluated the air leakage and electric power consumption of Residential HVAC components, with a particular focus on air leakage of furnace cabinets. Laboratory testing of HVAC components indicated that air leakage can be significant and highly variable from unit to unit ? indicating the need for a standard test method and specifying maximum allowable air leakage in California State energy codes. To further this effort, this project provided technical assistance for the development of a national standard for Residential HVAC equipment air leakage. This standard is being developed by ASHRAE and is called"ASHRAE Standard 193P - Method of test for Determining the Air Leakage Rate of HVAC Equipment". The final part of this project evaluated techniques for measurement of furnace blower power consumption. A draft test procedure for power consumption was developed in collaboration with the Canadian General Standards Board: CSA 823"Performance Standard for air handlers in residential space conditioning systems".

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of viral resuspension methods for carbon-rich soils along a permafrost thaw gradient

Permafrost stores approximately 50% of global soil carbon (C) in a frozen form; it is thawing rapidly under climate change, and little is known about viral communities in these soils or their roles in C cycling. In permafrost soils, microorganisms contribute significantly to C cycling, and characterizing them has recently been shown to improve prediction of ecosystem function. In other ecosystems, viruses have broad ecosystem and community impacts ranging from host cell mortality and organic matter cycling to horizontal gene transfer and reprogramming of core microbial metabolisms. Here we developed an optimized protocol to extract viruses from three types of high organic-matter peatland soils across a permafrost thaw gradient (palsa, moss-dominated bog, and sedge-dominated fen). Three separate experiments were used to evaluate the impact of chemical buffers, physical dispersion, storage conditions, and concentration and purification methods on viral yields. The most successful protocol, amended potassium citrate buffer with bead-beating or vortexing and BSA, yielded on average as much as 2-fold more virus-like particles (VLPs) g –1 of soil than other methods tested. All method combinations yielded VLPs g –1 of soil on the 10 8 order of magnitude across all three soil types. The different storage and concentration methods did not yield significantly more VLPs g –1 of soil among the soil types. In conclusion, this research provides much-needed guidelines for resuspending viruses from soils, specifically carbon-rich soils, paving the way for incorporating viruses into soil ecology studies.

54 ENVIRONMENTAL SCIENCES↗

Electronic analog equalization for vibrational testing

Method of real time equalization involving use of an analog computer achieves effective qualification testing by realistically simulating the effects of the vibrational forces which will actually be experienced in powered flight.

Trubert, M. R. P.↗