Advancements of On-Line Monitoring and Real-Time Characterization of Actual Low-Level Hanford Tank-Waste Samples

Waste and process stream characterization is essential to the safe, efficient, and cost-effective processing of Hanford Site materials. The demand for materials characterization including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward Hanford waste treatment and immobilization. Our past work has applied Raman on-line monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105 and has demonstrated the quantitative measurement of nine analytes within this waste. To demonstrate broader applicability, this method has now been expanded to waste from two additional Hanford tanks, AW-102 and AP-107, and the offgas condensate from lab-scale melter runs of actual-tank waste feeds. To enhance the performance of the Raman method, instruments with various excitation wavelengths were compared, since it is known that the Raman response is enhanced by shorter wavelength excitation. The laser excitations for the three systems tested were 404 nm, 532 nm, and 671 nm. In addition to laser wavelength selection, the laser power, measurement integration times, and signal averaging techniques were also investigated to determine their effect on detection limits for oxy-anion analytes within tank wastes. These advancements in Raman capability are compared with past standards and will be presented.

Bryan, Samuel A.↗

Results for the January 2023 Semiannual Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the January 2023 Semiannual sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Mission Completion (SRMC) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) LIMITS and TARGETS that were established at the time the Tank 50 sample was obtained.1 The chemical and radionuclide contaminant results from the characterization of the January 2023 semiannual sampling of Tank 50 were requested by SRMC personnel via a Task Technical Request (TTR)2 and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP).3 This Technical Report is part of Deliverable 2 relating to Task 1 from the SRMC request.2 Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals per Task 2 from the SRMC request will be obtained semiannually for the January 2023 and July 2023 Tank 50 samples.

Crawford, Charles L.↗

Inspection Tools for Hanford Tanks and Waste Transport Systems - 20444

Recent integrity issues in the double-shell tanks (DST) at Hanford have motivated the need for developing innovative tools that can provide information regarding the health of the tanks. These issues include the primary linear failure of AY-102 and recent concerns of thinning in the DST secondary liners. Other concerns include erosion or corrosion on transfer lines and processing pipes. In recent years, Florida International University (FIU) has supported DOE-EM by developing tools that can assist in understanding the health of tanks and waste transport system at Hanford. More specifically, FIU has developed a miniature rover that can be deployed through small risers and gain access to refractory slots in the Hanford DSTs. It traverses through the slots on the primary liner upside down via magnets to avoid debris in the slots. Recent modifications include a spring loaded magnetic arm that allows the unit to traverse over large weld seams but does not reduce the overall functionality of the system. The system has also incorporated a control capsule that will sit within the annulus of the tank and improves on issues related to signal and voltage loss over long tether lines. Lastly, the unit is also being augmented with a second module that will include a means to prep the tank surface and obtain a thickness measurement using a dual element ultrasonic sensor. FIU has also developed a 6-inch peristaltic pipe crawler that operates similar to the previous pipe crawlers developed at FIU. This crawler is a marsupial type crawler that will navigate through the 6-inch drain lines, and deploy a small rover at the entrance of the drain slots. This rover will also traverse upside down on the secondary liner and provide information regarding the health of the liner. An initial prototype for the crawler unit has been developed, assembled and tested. The system is pneumatic and consists of three modules - two grippers and one extender. The validation tests are conducted in a mockup of the drain lines and demonstrate the system's ability to navigate through long pipe lengths and elbows. In this paper, a general overview of each of the aforementioned systems is presented along with results from testing and demonstrations that shows the applicability of each system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 14H Preliminary Cease Waste Removal Sample Analyses

Savannah River Mission Completion Waste Removal and Tank Closure requested that Savannah River National Laboratory perform characterization analyses of Tank 14H in support of closure activities, specifically preliminary cease waste removal. This report provides important characterization of the prepared filtrate and air-dried solids in the January 2026 Tank 14H sample, HTF-14-26-1,2,3,4,5,6, for I-129, Tc-99, Cs-137, and Sr-90. The results reported here were utilized by SRMC to declare preliminary cease waste removal for Tank 14H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced prediction of Cs removal by CST from Hanford tank waste with K accountability

Abstract The treatment of Hanford tank waste is one of the most challenging environmental cleanup activities to date. To expedite the processing of liquid waste stored in underground tanks in Washington State it is necessary to remove the significant dose contributor, 137 Cs. Crystalline silicotitanate ion exchanger is currently used to remove 137 Cs from the aqueous phase of Hanford tank wastes in preparation for vitrification at the Waste Treatment and Immobilization Plant (WTP). Improving the understanding of potassium impacts on ion exchange behavior of Cs will help in the operation of a critical component of one of the most complex treatment processes in the world today. Optimization of this process can result in significant cost savings and less waste production. Toward this effort, a series of batch contact tests varied in potassium concentration were conducted to look at the impact of potassium concentration on Cs distribution. Experimental distribution ratios ( K d ) were compared to the distribution ratios predicted using the ZAM model. A significant underprediction of Cs capacity in the presence of potassium was seen with the existing model. A revision of the equilibrium constants was determined and provided a statistically better fit for determining the Cs K d values in tank waste matrices.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of dilution-induced precipitates on the filtration of Hanford liquid tank wastes

To facilitate its vitrification, a portion of the radioactive wastes currently stored at the Hanford Site will be staged and treated using tank-side operations to render their chemistry compliant with the requirements of Hanford’s low-activity waste vitrification facility. Initial sampling of staged feeds indicates that process-water dilution, used to reduce waste feed sodium content to levels acceptable for vitrification (5–6 M Na), may cause precipitation of fine, difficult to settle solids that could affect downstream tank-side filtration and ion-exchange. However, dilution-induced precipitation has not been demonstrated under controlled, rigorous laboratory conditions. This paper presents a set of qualitative and quantitative assessments of dilution-induced precipitation using a nonradioactive, Hanford Tank AP-105 simulated waste. Further, these studies found that dilution of AP-farm waste simulants induced precipitation of up to 150 ppm solids, regardless of whether dilution was done with process water (which contains, among other analytes, naturally occurring Ca and Mg) or deionized water. Naturally occurring process-water analytes appeared to accelerate the rate (and possibly extent) of precipitation. Filtration of diluted waste simulants also found that the precipitated solids challenged prototypic tank-side filter operations; however, the impact to filtration performance was readily managed through waste staging settle/decant operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methods for Estimating Hydrogen Fuel Tank Characteristics

The pressure vessels needed to store hydrogen for next-generation hydrogen fuel cell vehicles are expected to be a substantial portion of the total system mass, volume, and cost. Gravimetric capacity, volumetric capacity, and cost per kilogram of usable hydrogen are key performance metrics that the U.S. Department of Energy (DOE) uses to determine the viability of hydrogen fuel cell systems. Research and development related to hydrogen storage systems covers a wide range of potential operating conditions, from cryogenic temperatures to high temperatures (above ambient) and low pressure to high pressure. Researchers at PNNL have developed methods for estimating these key pressure vessel characteristics to support on-board hydrogen storage system design and performance evaluation and to support decision-making about DOE hydrogen storage system research investments. This article describes the pressure tank estimation methodology that has been used as a stand-alone calculation and has been incorporated into larger system evaluation tools. The methodology estimates the geometry, mass, and material cost of type I, type III, and type IV pressure vessels based on operating pressure and material strength at the system's operating temperature, using classical thin-wall and thick-wall pressure vessel stress calculations. The geometry, mass, and material cost requirements of the pressure vessel have significant impacts on the total system performance. For example, hydrogen storage materials that can separately achieve a very high hydrogen density can be deemed impractical for use in fuel cell vehicle hydrogen storage systems because the pressure tank containing them is too large, heavy, or expensive. This article describes the design philosophy and analytical process of the tank characteristic estimation methodology, which has been implemented in spreadsheet calculation tools and system-level analysis tools used by DOE researchers. Each of the three tank types (type I, type III, and type IV) uses a different analysis methodology with some common elements. This article also provides examples of implementing the methodology to perform parametric studies of all three pressure vessel types. The goal of this article is to present the methodology in sufficient detail so it can be implemented in other hydrogen fuel cell vehicle design and analysis tools.

42 ENGINEERING↗

Methylmercury Retention Evaluation to Support Tank 50 and Saltstone Waste Acceptance Criteria: Parts 2 and 3

The objective of this work was to provide a technical basis for the organic mercury waste acceptance criterion (WAC) for Tank 50 salt solution. The current mercury WAC for Tank 50 solution is 325 mg/L as Hg regardless of the form of mercury, which is about three times higher than any total Hg concentrations measured to date in Tank 50 solution. To date, the highest total Hg and MeHg + concentrations in the Tank 50 solution were 105 and 62 mg/L, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Defense Waste Processing Facility Sample: Recycle Collection Tank Sample Batch 4945

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (now Savannah River Mission Completion (SRMC)), through a Technical Task Request, to characterization the “as-received” Recycle Collection Tank (RCT) Sample identified as sample batch 4945 [Sludge Receipt and Adjustment Tank (SRAT) batch 796)], which was delivered to SRNL Shielded Cells on January 28, 2021. The RCT characterization data will be used as input to the Defense Waste Processing Facility (DWPF) Recycle Diversion Project. This RCT report is the first of three sample characterization reports that will be used for this DWPF Project. The other DWPF reports will involve the characterization of the Off-Gas Condensate Tank (OGCT) and the Slurry Mix Evaporator Condensate Tank (SMECT) samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the September Bimonthly Calendar Year 2021 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the 2021 September bimonthly sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) Limits and Targets that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the 2021 September bimonthly sampling of Tank 50 were requested by SRR personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is the TTR deliverable relating Salt Solution Analysis from the SRR request.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Results from November 2021 Qualification Samples for Tank Closure Cesium Removal 1A (TCCR 1A)

Savannah River Remediation (SRR) is currently operating the Tank Closure Cesium Removal 1A (TCCR 1A) process to remove 137 Cs from tank waste supernate using an ion exchange process. As part of that process, Savannah River National Laboratory (SRNL) receives and analyzes samples in support of the qualification of each batch to be processed. SRNL recently received supernate samples retrieved from Tank 10H as well as in-tank batch contact samples for characterization in support of qualifying Batch 1 for processing through the TCCR 1A unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Results from Batch 1 Qualification Samples for Tank Closure Cesium Removal 1A (TCCR 1A)

Savannah River Remediation (SRR) is currently operating the Tank Closure Cesium Removal 1A (TCCR 1A) process to remove 137 Cs from tank waste supernate using an ion exchange process. As part of that process, Savannah River National Laboratory (SRNL) receives and analyzes samples in support of the qualification of each waste supernate batch to be processed. SRNL recently received supernate samples retrieved from Tank 10H as well as in-tank batch contact samples for characterization in support of qualifying Batch 1 for processing through the TCCR 1A unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Defense Waste Processing Facility Sample: Recycle Collection Tank Sample Batch 4945

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (now Savannah River Mission Completion (SRMC)), through a Technical Task Request, to characterization the “as-received” Recycle Collection Tank (RCT) Sample identified as sample batch 4945 [Sludge Receipt and Adjustment Tank (SRAT) batch 796)], which was delivered to SRNL Shielded Cells on January 28, 2021. The RCT characterization data will be used as input to the Defense Waste Processing Facility (DWPF) Recycle Diversion Project. This RCT report is the first of three sample characterization reports that will be used for this DWPF Project. The other DWPF reports will involve the characterization of the Off-Gas Condensate Tank (OGCT) and the Slurry Mix Evaporator Condensate Tank (SMECT) samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the March Bimonthly Calendar Year 2022 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the 2022 March bimonthly sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Mission Completion (SRMC) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) LIMITS and TARGETS that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the 2022 March bimonthly sampling of Tank 50 were requested by SRMC personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is the TTR deliverable relating Salt Solution Analysis from the SRMC request.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Blend Pump Mixing in Tank 27 Evaluation

For future waste disposal operations, Savannah River Mission Completion (SRMC) plans to operate Tank 27 as a blend tank. It is desirable to avoid additional worker exposure by using the planned commercial submersible mixing pump (CSMP) installations in Risers B2 and B4 to function as the blend pumps for prolonged blend tank operations. The purpose of this task is to evaluate the impacts to mixing across a range of pump installation heights from 1 to 201 inches. Specifications include: A maximum pump diameter of 22.5 inches, dual nozzles placed tangentially opposed with nominal inside diameter of 2 inches, a total flow range (both nozzles combined) of 500 to 1950 gallons per minute (gpm) and a maximum revolutions per minute (RPM) of 1800. Tank 27 is expected to have maximum fill height of 360 inches.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the September Bimonthly Calendar Year 2022 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the 2022 September bimonthly sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Mission Completion (SRMC) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) LIMITS and TARGETS that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the 2022 September bimonthly sampling of Tank 50 were requested by SRMC personnel via a Task Technical Request (TTR). Details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is the TTR deliverable relating Salt Solution Analysis from the SRMC request. The following facts pertaining to the WAC are drawn from the analytical results, including analytical uncertainty, provided in this report. 1) WAC LIMITS and TARGETS were met for all analyzed chemical and radioactive contaminants for which the detection limits are below the WAC LIMITS and TARGETS; 2) Measured average concentrations of nitrate, nitrite and total mercury are approximately 24%, 9% and 12% of the WAC LIMITS, respectively; 3) Measured average concentrations of Tc-99 and I-129 are approximately 19% and 20% of the WAC LIMITS, respectively; 4) All other radionuclide average concentrations are at 4% or less of the WAC LIMITS and TARGETS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Thermal-Protection Systems for Space-Vehicle Cryogenic-Propellant Tanks

Analytical techniques are presented that permit the calculation of heat-transfer rates with various thermal-protection systems for liquid-cryogenic-propellant tanks subjected to on-board, solar, and planetary heat fluxes. The thermal-protection systems considered include using closely spaced reflective surfaces (foils) and widely spaced reflective surfaces (shadow shields), insulation, arrangement of vehicle components, orientation with respect to radiant heating sources, and coatings for the control of solar absorptivity. The effectiveness of these thermal-protection systems in reducing propellant heating is shown both for ideal heat-transfer models and for a simplified hydrogen-oxygen terminal stage on a Mars mission. The proper orientation of a space-vehicle cryogenic tank with respect to the Sun is one of the more beneficial methods of reducing the heating effect of solar flux. Shadow shields can be extremely effective in reducing the propellant heating due to both solar and on-board fluxes. However, low-altitude planet orbits can result in high propellant heating rates due to planetary radiation reflected from the shields. For low-altitude orbits of more than a few days, foils appear to be desirable for all cryogenic-tank surfaces. Foils are also effective in reducing the on-board heating. A choice of shadow shields or foils cannot be made until a particular vehicle and a particular mission are chosen. The thermal conductivity of insulation materials would have to be lower by about two orders of magnitude with no increase in density before insulation could compete with reflective surfaces for use in long-duration thermal protection of cryogenic tanks in space. To demonstrate the application of the methods devised, thermal-protection systems are developed for a hydrogen-oxygen terminal stage for typical Mars missions.

SPACE VEHICLE↗

Thermal Desktop Modeling of the 2016 CRYOTE-2 Tank Chill and Fill Tests

The storing and transfer of cryogenic propellants is an enabling technology for NASA as it moves to expand future missions into low Earth orbit (LEO) and beyond. The transfer of cryogenic propellants is of particular interest because it has never been successfully demonstrated in microgravity. Several ground tests have been conducted in past decades examining various tank chilldown and fill methods. Creating accurate models using these historical datasets is a vital step toward developing appropriate modeling tools to form pre-test predictions for eventual flight and ground tests of various novel injector concepts. The goal of this work was to create a working model in Thermal Desktop using data from the CRYOTE-2 experiments whose purpose was to demonstrate the chill and fill process in a spherical receiver tank parametrically examining the effect of injection method, receiver tank initial wall temperature and initial state, supply pressure, and mass flow rate on the NVF process. These tests were conducting using liquid nitrogen with different injectors with different injection patterns. The focus of the current work is on one particular spray nozzle. The pressure rise inside the tank, the fill level, and the change in the outside wall temperature were all tracked and compared with test data. The Thermal Desktop model was able to accurately predict each of these metrics for this nozzle within 11.0%, 22.0%, and 7.0%, respectively.

Cryogenic Tank Chilldown↗