Robotic Cleaning of the Total Dissolved Solids Tanks at the Palo Verde Nuclear Generating Station - 18337

Westinghouse is executing a contract from Arizona Public Services to provide a system capable of removing highly radioactive sediment from eight Total Dissolved Solids (TDS) Tanks located at the Palo Verde Nuclear Generating Station. The scope of work covers the design, procurement, fabrication, and eventual operation of the system at the Palo Verde Site. It also includes the factory acceptance testing of the system, prior to operation at the site. Previous attempts to clean the tanks involved working inside and around the tanks for extended periods of time in a high radiation field. Spray hoses were used to wash down the sediment, and hand tools were used to scrape out the remaining sludge at the bottom. This methodology also required the lower manway to be removed. As a result, the worker radiation exposure limit was exceeded on the first of the nine tanks. As a solution to the high radiation environment of the TDS tanks, Westinghouse will provide and operate a pneumatically powered robotic crawler. This crawler traverses the bottom of the tank with a 4,000 psi high-pressure spray head affixed to the front of the crawler to blast sediment from the walls and floor of the TDS tanks. This paper will present the conceptual design of the TDS Tank cleaning system, noting the key benefits of specific components in the overall technology basis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring Waste Tanks Using Guided Wave Technology - 18576

There are many challenges associated with the inspections of double-shell storage tanks containing radioactive waste, including limited space for accessibility and maneuverability, environments with high radiation, temperature and toxicity, and unknown physical conditions. Contents of the tank and limited space may prevent access of scanning devices that employ conventional NDE techniques such as ultrasonics, eddy current, or magnetic based methods. Resolving these challenges will become more urgent as the nuclear industry is forced to address the complications of the aging nuclear infrastructure - specifically at tank storage locations on laboratory sites across the DOE complex. A powerful, new approach to inspecting and monitoring the structural integrity of large structures, such as double-shelled tanks, is being developed using ultrasonic guided waves. Acoustic waves that propagate in a plate or other structure where the wavelength is larger than the thickness of the structure are known as ultrasonic guided waves. Ultrasonic guided waves can potentially propagate distances of tens to hundreds of feet in plate-like structures, such as those that comprise the walls and bottom of a storage tank. Guided waves enable the examination of relatively large inspection volumes from the outside surface of the structure. In double-shell tanks, the technology offers promise for examining the floor of the structure or the walls by placing guided wave sensors at accessible locations in the annulus. This guided wave technology has the capability to detect and localize areas of damage or degradation. While guided wave has recently been used in the nuclear and oil and gas industries for inspecting one-dimensional piping systems, current research is developing methods to apply this technology to the two-dimensional surfaces of double-shell storage tanks. Permanently installed sensors are being developed which would remotely collect data that would be analyzed to monitor the structural condition of the tank. Initial tests have been conducted on single plate structures to study guided wave interaction with various shapes and sizes of pertinent simulated damage mechanisms, and the experimental results were compared with hybrid finite-element numerical models. Dispersion curves were calculated to study guided wave modes and their properties in carbon steel plates and to evaluate behaviors at joints between plates. The next steps in the research process include applying the transmitters and sensors to full scale mockups, developing more mature data interpretation, and then demonstrations at an actual site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Tc-99 Speciation and Chemical Composition of 241-AN-102 Tank Waste Supernatant - 19201

Technetium (Tc) in its isotopic form {sup 99}Tc is generated in high yields from the fission of {sup 235}U and {sup 239}Pu. A significant inventory of {sup 99}Tc remains at the U.S. Department of Energy's Hanford Site, and it is one of the most difficult contaminants to address. In the strongly alkaline solutions that are typical of Hanford tank waste, Tc exists as both pertechnetate (TcO{sub 4}{sup -} in oxidation state VII) and in reduced forms (oxidation state <VII) collectively known as non-pertechnetate species. Pertechnetate is a well-characterized anionic Tc species that can be removed from low-activity waste by anion exchange or other methods. There is no definitive information on the origin or a comprehensive description of the non-pertechnetate species in Hanford tanks. Designing strategies for effective management of Tc, including separation and immobilization, requires an understanding of the molecular structure of the non-pertechnetate species and their identification in actual tank waste samples. Developing this advanced understanding would facilitate development of new technologies for treating dissimilar Tc species. Toward this objective, a spectroscopic library of the Tc(I) [fac-Tc(CO){sub 3}]{sup +} and Tc(IV, VI, VII) compounds was generated using a range of techniques and applied to the characterization of actual 241-AN-102 tank waste supernatant. A sample of the 241-AN-102 tank waste (collected in 2013) was processed to remove {sup 137}Cs by spherical resorcinol-formaldehyde (sRF) ion exchange resin after the sodium concentration was adjusted to 5.6 M. The Cs-loaded sRF column was eluted with 0.45 M HNO{sub 3}. As-received AN-102, Cs-depleted AN-102 effluent, and sRF eluate fractions were comprehensively characterized for chemical composition and speciation of Tc using {sup 99}Tc nuclear magnetic resonance (NMR) spectroscopy and X-ray absorption spectroscopy. The results of these analyses demonstrated for the first time that non-pertechnetate Tc present in the 241-AN-102 tank waste is composed of several low-valent Tc species, including the Tc(I) [fac-Tc(CO){sub 3}L{sub 3}]{sup +}, Tc(IV), and possibly Tc(VI) compounds. This is the second experimental observation of the [fac-Tc(CO){sub 3}L{sub 3}]{sup +} species in the Hanford tank waste that highlights their importance for waste processing. In addition, the chemical composition of the 241-AN-102 tank waste was characterized with the focus on small chelators. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress on Advancing Robotic Ultrasonic Volumetric Inspection Technology for Hanford Under-tank Inspection - 19474

The Hanford River Protection Project is reliant on safe interim storage of high-level waste at the Hanford site and will continue to depend on it until the waste has been treated and vitrified by the Hanford Waste Treatment and Immobilization Plant (WTP). The Hanford double-shell tanks (DSTs) have provided interim storage since the DSTs were put into service (1971 - 1986) and the RPP will continue to rely on their service until least 2050, at which time the 27 in-service DSTs will be 14-54 years beyond their original design lives. As the DSTs continue to age and be operated beyond design life, reliable leak integrity assessments of primary tanks and secondary liners will become increasingly important in order to provide situational awareness to tank operations personnel and to support risk-informed decisions on the selection of DSTs as waste feed staging tanks and the order and timing of future DST refurbishment or, alternatively, DST retrieval sequence. This paper summarizes progress made in fiscal year (FY) 2018 on the engineering of a robotic air-slot volumetric inspection system (RAVIS) that is designed to perform ultrasonic (volumetric) leak integrity inspections of physically inaccessible primary tank bottom plates and welds. Leak integrity inspections performed with the RAVIS will supplement today's primary tank leak integrity inspections, which are currently limited to physically accessible sidewall plates and welds. The RAVIS will be deployed into air slots of the insulating concrete (refractory) pad beneath the primary tanks and use its ultrasonic guided wave phased-array (GWPA) sensor to electronically steer an ultrasonic beam 360-degrees around the sensor to volumetrically examine adjacent carbon steel plates and welds covered by refractory pad material. Deployments of RAVIS down multiple air-slots will be performed to determine which regions of a tank bottom have sound leak integrity or which regions are in need of future wall thickness restoration or weld repair due to pitting corrosion, general corrosion, or heat/stress-induced cracks. The initial RAVIS design and the flaw detection test results for the first air-slot GWPA sensor that was designed to fit inside the air-slots will be presented in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DOE Hanford Tank Side Cesium Removal System (TSCR) Update: Fabrication and Factory Acceptance Testing - 20300

The Tank Side Cesium Removal (TSCR) System is a modular, quickly-deployable, and passively safe system for efficiently removing solids and cesium from alkaline liquid waste raffinate created by fuel processing on the Hanford site. This paper provides an overview of the project with particular emphasis on completion of fabrication and factory acceptance testing (FAT). All TSCR System components are inside three enclosures known as the Process Enclosure, Ancillary Enclosure, and Control Enclosure. The Process Enclosure is seismic design category II (SDC-II) and built to withstand the rigors of transportation and lifting, high winds, volcanic ash fall, and heavy precipitation (snow) over a temperature range of -25 to 115 deg. F. The Process Enclosure and Control Enclosure were fabricated in AVANTech's Columbia, SC facility, while the Ancillary Enclosure was fabricated in AVANTech's Richland, WA facility. The design and preliminary documented safety analysis were completed in December 2019, with all work being performed in accordance with ASME NQA-1 quality assurance requirements. The Process Enclosure, Ion Exchange Columns (IXCs), and several other TSCR components have a nuclear safety function and are designated as safety significant structures, systems, and components (SS-SSCs). The NQA-1 Commercial Grade Dedication (CGD) process was used to identify critical characteristics in order to accept materials and items used for fabrication of several safety significant TSCR components. This paper also addresses unique aspects and challenges of implementing CGD in DOE facilities and systems. After fabrication and preliminary testing, the Process and Control Enclosures were shipped to AVANTech's Richland facility where the complete TSCR System was setup and connected in a represented layout and configuration that will be used on the Hanford site. Test tanks and pumps were put in place and connected to the TSCR Process Enclosure in a manner that mimicked interfacing Double Shell Tanks in the 241-AP Tank Farm. The TSCR System was then tested/operated under conditions equivalent to those planned for onsite operation. Testing was separated into five separate phases as defined below: - Phase 1: Confirmation of TSCR System readiness for the FAT; - Phase 2: Verification of TSCR System operation under standard conditions; - Phase 3: Demonstration of TSCR System operation under non-standard conditions; - Phase 4: Demonstration of ion exchange media removal from an IXC; and - Phase 5: Completion of TSCR System lift plans and site mobilization. The Hanford Tank Operations Contractor, Washington River Protection Solutions (WRPS), participated in all phases of testing. Testing at AVANTech's Richland Facility allowed WRPS personnel to familiarize themselves with TSCR operations in a radiologically clean facility prior to onsite mobilization. Engineering and operations personnel gained valuable experience that allowed them to better refine onsite operational protocols and procedures - including handling and movement of IXCs with a forklift. This paper describes the technologies used by the TSCR System as well as how these technologies are deployed and operated to advance the Hanford mission of safely, efficiently, and effectively treating tank waste. It also provides detailed information on fabrication and FAT, including operational data from simulated tank waste runs. A project schedule for WRPS' planned construction acceptance testing, operational acceptance testing, and actual tank waste treatment is provided. This presentation should be of great interest to parties responsible for the design, testing, and mobilization of modular NQA-1 technologies for the treatment of raffinate and similar liquid wastes containing high concentrations of radioactive cesium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DOUBLE SHELL TANK (DST) INTEGRITY PROJECT HIGH LEVEL WASTE CHEMISTRY OPTIMIZATION

The U.S. Department of Energy's Office (DOE) of River Protection (ORP) has a continuing program for chemical optimization to better characterize corrosion behavior of High-Level Waste (HLW). The DOE controls the chemistry in its HLW to minimize the propensity of localized corrosion, such as pitting, and stress corrosion cracking (SCC) in nitrate-containing solutions. By improving the control of localized corrosion and SCC, the ORP can increase the life of the Double-Shell Tank (DST) carbon steel structural components and reduce overall mission costs. The carbon steel tanks at the Hanford Site are critical to the mission of safely managing stored HLW until it can be treated for disposal. The DOE has historically used additions of sodium hydroxide to retard corrosion processes in HLW tanks. This also increases the amount of waste to be treated. The reactions with carbon dioxide from the air and solid chemical species in the tank continually deplete the hydroxide ion concentration, which then requires continued additions. The DOE can reduce overall costs for caustic addition and treatment of waste, and more effectively utilize waste storage capacity by minimizing these chemical additions. Hydroxide addition is a means to control localized and stress corrosion cracking in carbon steel by providing a passive environment. The exact mechanism that causes nitrate to drive the corrosion process is not yet clear. The SCC is less of a concern in the newer stress relieved double shell tanks due to reduced residual stress. The optimization of waste chemistry will further reduce the propensity for SCC. The corrosion testing performed to optimize waste chemistry included cyclic potentiodynamic volarization studies. slow strain rate tests. and stress intensity factor/crack growth rate determinations. Laboratory experimental evidence suggests that nitrite is a highly effective:inhibitor for pitting and SCC in alkaline nitrate environments. Revision of the corrosion control strategies to a nitrite-based control, where there is no constant depletion mechanism as with hydroxide, should greatly enhance tank lifetime, tank space availability, and reduce downstream reprocessing costs by reducing chemical addition to the tanks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FITNESS-FOR-SERVICE ASSESSMENT FOR A RADIOACTIVE WASTE TANK THAT CONTAINS STRESS CORROSION CRACKS

Radioactive wastes are confined in 49 underground storage tanks at the Savannah River Site. The tanks are examined by ultrasonic (UT) methods for thinning, pitting, and stress corrosion cracking in order to assess fitness-for-service. During an inspection in 2002, ten cracks were identified on one of the tanks. Given the location of the cracks (i.e., adjacent to welds, weld attachments, and weld repairs), fabrication details (e.g., this tank was not stress-relieved), and the service history the degradation mechanism was stress corrosion cracking. Crack instability calculations utilizing API-579 guidance were performed to show that the combination of expected future service condition hydrostatic and weld residual stresses do not drive any of the identified cracks to instability. The cracks were re-inspected in 2007 to determine if crack growth had occurred. During this re-examination, one indication that was initially reported as a 'possible perpendicular crack <25% through wall' in 2002, was clearly shown not to be a crack. Additionally, examination of a new area immediately adjacent to other cracks along a vertical weld revealed three new cracks. It is not known when these new cracks formed as they could very well have been present in 2002 as well. Therefore, a total of twelve cracks were evaluated during the re-examination. Comparison of the crack lengths measured in 2002 and 2007 revealed that crack growth had occurred in four of the nine previously measured cracks. The crack length extension ranged from 0.25 to 1.8 inches. However, in all cases the cracks still remained within the residual stress zone (i.e., within two to three inches of the weld). The impact of the cracks that grew on the future service of Tank 15 was re-assessed. API-579 crack instability calculations were again performed, based on expected future service conditions and trended crack growth rates for the future tank service cycle. The analysis showed that the combined hydrostatic and weld residual stresses do not drive the identified cracks to instability. This tank expected to be decommissioned in the near future. However, if these plans are delayed, it was recommended that a third examination of selected cracks in the tank be performed in 2014.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Relationship Between Flowability And Tank Closure Grout Quality

After completion of waste removal and chemical cleaning operations, Tanks 5-F and 6-F await final closure. The project will proceed with completing operational closure by stabilizing the tanks with grout. Savannah River Remediation's (SRR) experience with grouting Tanks 18-F and 19-F showed that slump-flow values were correlated with flow/spread inside these tanks. Less mounding was observed when using grouts with higher slump-flow. Therefore, SRNL was requested to evaluate the relationship between flowability and cured properties to determine whether the slump-flow maximum spread of Mix LP#8-16 could be increased from 28 inches to 30 inches without impacting the grout quality. A request was also made to evaluate increasing the drop height from 5 feet to 10 feet with the objective of enhancing the flow inside the tank by imparting more kinetic energy to the placement. Based on a review of the grout property data for Mix LP#8-16 collected from Tank 18-F and 19-F quality control samples, the upper limit for slump-flow measured per ASTM C 1611 can be increased from 28 to 30 inches without affecting grout quality. However, testing should be performed prior to increasing the drop height from 5 to 10 feet or observations should be made during initial filling operations to determine whether segregation occurs as a function of drop heights between 5 and 10 feet. Segregation will negatively impact grout quality. Additionally, increasing the delivery rate of grout into Tanks 5-F and 6-F by using a higher capacity concrete/grout pump will result in better grout spread/flow inside the tanks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ACTUAL WASTE TESTING OF GYCOLATE IMPACTS ON THE SRS TANK FARM

Glycolic acid is being studied as a replacement for formic acid in the Defense Waste Processing Facility (DWPF) feed preparation process. After implementation, the recycle stream from DWPF back to the high-level waste Tank Farm will contain soluble sodium glycolate. Most of the potential impacts of glycolate in the Tank Farm were addressed via a literature review and simulant testing, but several outstanding issues remained. This report documents the actual-waste tests to determine the impacts of glycolate on storage and evaporation of Savannah River Site high-level waste. The objectives of this study are to address the following: Determine the extent to which sludge constituents (Pu, U, Fe, etc.) dissolve (the solubility of sludge constituents) in the glycolate-containing 2H-evaporator feed. Determine the impact of glycolate on the sorption of fissile (Pu, U, etc.) components onto sodium aluminosilicate solids. The first objective was accomplished through actual-waste testing using Tank 43H and 38H supernatant and Tank 51H sludge at Tank Farm storage conditions. The second objective was accomplished by contacting actual 2H-evaporator scale with the products from the testing for the first objective. There is no anticipated impact of up to 10 g/L of glycolate in DWPF recycle to the Tank Farm on tank waste component solubilities as investigated in this test. Most components were not influenced by glycolate during solubility tests, including major components such as aluminum, sodium, and most salt anions. There was potentially a slight increase in soluble iron with added glycolate, but the soluble iron concentration remained so low (on the order of 10 mg/L) as to not impact the iron to fissile ratio in sludge. Uranium and plutonium appear to have been supersaturated in 2H-evaporator feed solution mixture used for this testing. As a result, there was a reduction of soluble uranium and plutonium as a function of time. The change in soluble uranium concentration was independent of added glycolate concentration. The change in soluble plutonium content was dependent on the added glycolate concentration, with higher levels of glycolate (5 g/L and 10 g/L) appearing to suppress the plutonium solubility. The inclusion of glycolate did not change the dissolution of or sorption onto actual-waste 2H-evaporator pot scale to an extent that will impact Tank Farm storage and concentration. The effects that were noted involved dissolution of components from evaporator scale and precipitation of components onto evaporator scale that were independent of the level of added glycolate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Settler Tank Thermal Stability during Solidification and Disposition to ERDF

Ten 16-foot-long and 20-inch diameter horizontal tanks currently reside in a stacked 2×5 (high) array in the ~20,000-gallon water-filled Weasel Pit of the 105-KW Fuel Storage Basin on the US-DOE Hanford Site. These ten tanks are part of the Integrated Water Treatment System used to manage water quality in the KW Basin and are called “settler” tanks because of their application in removing particles from the KW Basin waters. Based on process knowledge, the settler tanks are estimated to contain about 124 kilograms of finely divided uranium metal, 22 kg of uranium dioxide, and another 55 kg of other radioactive sludge. The Sludge Treatment Project (STP), managed by CH2MHill Plateau Remediation Company (CHPRC) is charged with managing the settler tanks and arranging for their ultimate disposal by burial in ERDF. The presence of finely divided uranium metal in the sludge is of concern because of the potential for thermal runaway reaction of the uranium metal with water and the formation of flammable hydrogen gas as a product of the uranium-water reaction. Thermal runaway can be instigated by external heating. The STP commissioned a formal Decision Support Board (DSB) to consider options and provide recommendations to manage and dispose of the settler tanks and their contents. Decision criteria included consideration of the project schedule and longer-term deactivation, decontamination, decommissioning, and demolition (D4) of the KW Basin. The DSB compared the alternatives and recommended in-situ grouting, size-reduction, and ERDF disposal as the best of six candidate options for settler tank treatment and disposal. It is important to note that most grouts contain a complement of Portland cement as the binding agent and that Portland cement curing reactions generate heat. Therefore, concern is raised that the grouting of the settler tank contents may produce heating sufficient to instigate thermal runaway reactions in the contained uranium metal sludge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of Hanford Tank Waste 241-AP-105 in a Continuous Laboratory-Scale Melter

Low-activity waste (LAW) stored in underground tanks on the Hanford site in Washington State is planned to be filtered for solids removal and processed through ion exchange columns for cesium removal at the Low-Activity Waste Pretreatment System facility. These pretreatment steps will allow the waste to be transferred to the Hanford Tank Waste Treatment and Immobilization Plant LAW facility for immobilization into glass. The liquid waste will be combined with glass-forming chemicals (GFCs) to form a waste feed slurry that can be fed to electric melters for vitrification. The process of continuously converting the aqueous feed slurry into a melt is dynamic and includes multiple reactions, degassing, and dissolution processes that depend on heat from the melt below. In this conversion process, waste components are partitioned into one of two streams: glass and off-gas. Processing information and chemical information associated with these waste product streams has been requested by Washington River Protection Solutions for actual tank waste from tank 241-AP-105 (referred to as AP-105). To acquire this type of information, a small-scale melter system was desired that would not require high volumes of input waste or the large resource commitment of a full-scale melter system, while also providing dynamic information that would be difficult to determine from batch reactions in a crucible system. A continuous laboratory-scale melter (CLSM), has been designed to operate with a continuous feeding process, while periodically pouring glass product and collecting off-gas. The CLSM vessel has been sized to collect the relevant process and chemical information from obtainable volumes of AP-105 waste samples. Two CLSMs were constructed: one in a non-radioactive environment for processing waste simulants and another in a fume hood capable of handling radioactive material for processing actual Hanford tank waste. This dual-system setup allowed for comparison between simulated and real tank waste with essentially identical test equipment. AP-105 waste simulant was first tested in the non-radioactive CLSM to determine the processability and desired operating window for the actual tank waste. Rhenium (Re) was added to the simulant to act as a surrogate for technetium-99 ( 99 Tc), a key waste component found in the actual tank waste. The partitioning of Re into the glass and off-gas products during the continuous feeding of simulant was determined, which allowed the Re retention, the mass flow rate of Re out of the CLSM via the glass product with respect to the mass flow rate of Re into the CLSM via the feed slurry, to be calculated. Key processing results and the average Re retention, from the CLSM test run with AP-105 simulant feed slurry are shown in Table ES.1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 23H (HTF-23-19-23, -24, -25) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 23H to support ECP and CCP. The results of the analysis indicate the concentrations of species in Tank 23H increase with depth in the tank. The sample obtained from the lowest level of 60” from the bottom of the tank shows the highest concentrations for most species analyzed. The surface sample and the 140” sub-surface sample show similar compositions with the sub-surface sample being slightly more concentrated, and both are more dilute than the lowest 60” sub-surface sample for most species analyzed. The total uranium concentration in the three Tank 23H samples show a slight increase from the surface sample to the next lower sub-surface sample, but then a slight decrease in the uranium concentration in the lowest sub-surface sample. The U-235 weight fraction ranges from 0.94-1.2% in the Tank 23H samples. The sum of the major cations versus the sum of the major anions shows a difference of ~5% or less for all three of the Tank 23H samples indicating good data quality for the non-radioactive analytes in the table. Small %RSD values for the replicate analyses with the exception of species close to the detection limit (e.g., Fe) provide another indication of good data quality for the non-radioactive species. The silicon concentrations measured in the Tank 23H samples were all below detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

End-of-Life Evaluation of Compressed Natural Gas Vehicle Fuel Tanks

This study evaluated the structural integrity of Type III and Type IV CNG fuel tanks from the Los Angeles (LA) County Metropolitan Transportation Authority to characterize the fuel tank conditions after experiencing a full service life of 15 years in transit bus application. The data produced provide insight about the condition of the CNG fuel tanks at the conclusion of their defined EOL and potential risks of continued operation of the CNG vehicle without replacement of the expired fuel tanks. In addition to physical testing performed on the fuel tanks, a nondestructive evaluation of modal acoustic emission (MAE) was utilized to assess the structural integrity of the tanks. The CNG fuel tanks were evaluated in their received condition and after experiencing artificial damage. The MAE results were then compared to visual inspection results of the procedures defined in the Compressed Gas Association’s (CGA’s) C-6.2 and C-6.4 standards (Compressed Gas Association 2013; 2012) to better understand the effectiveness of the visual inspection and potential safety risks of continued use of the tanks.

03 NATURAL GAS↗

New Tank Mapping Method Improves Waste Removal Process

Waste Tank Mapping Overview • Camera inspections are performed within available tank top risers and used to create waste tank maps – Several camera inspections are performed during waste removal transfers to verify the elevation of the visible salt/sludge mounds against the known elevation of the liquid surface • Tank mappings are used to evaluate the volume and distribution of saltcake or sludge that is present within the waste tank – Allows for refined operating strategies and process safety controls • New tank mapping process creates a standardized approach for accurately defining waste distribution within a waste tank while minimizing the required camera inspection footage – First utilized during the 2023 Tank 22 Sludge Removal Campaign

Mini, Melany [Savannah River Mission Completion (S↗

TANK 40 FINAL SB4 CHEMICAL CHARACTERIZATION RESULTS

A sample of Sludge Batch 4 (SB4) was pulled from Tank 40 in order to obtain radionuclide inventory analyses necessary for compliance with the Waste Acceptance Product Specifications (WAPS). This sample was also analyzed for elemental and chemical composition including noble metals. These analyses along with the WAPS analyses will help define the composition of the sludge currently in Tank 40 which is currently being fed to DWPF and will become part of Sludge Batch 5 (SB5). At SRNL the 3-L Tank 40 SB4 sample was transferred from the shipping container into a 4-L vessel and solids allowed to settle overnight. Supernate was then siphoned off and circulated through the shipping container to complete the transfer of the sample. Following thorough mixing of the 3-L sample, a 280 g sub-sample was removed. This sub-sample was then utilized for all subsequent analytical samples. Eight separate aliquots of the slurry were digested, four with HNO{sub 3}/HCl in sealed Teflon{reg_sign} vessels and four in Na{sub 2}O{sub 2} using Zr crucibles. Due to the use of Zr crucibles and Na in the peroxide fusions, Na and Zr cannot be determined from this preparation. Three glass standards were digested along with a blank for each preparation. Each aqua regia digestion and blank was diluted and submitted to Analytical Development (AD) for inductively coupled plasma-atomic emission spectroscopy (ICP-AES) analysis, inductively coupled plasma-mass spectrometry (ICP-MS) analysis, and cold vapor atomic absorption (CV-AA) analysis. Equivalent dilutions of the peroxide fusion digestions and blank were submitted to AD for ICP-AES analysis. Tank 40 SB4 supernate was collected from a mixed slurry sample in the SRNL Shielded Cells and submitted to AD for ICP-AES and ICP-MS. Weighted dilutions of slurry were submitted for ion chromatography (IC), total inorganic carbon/total organic carbon (TIC/TOC), and total base analyses. A sample of Tank 40 SB4 decant was collected by carefully removing the supernate phase from a settled sample. This decant was not filtered prior to performing a warm nitric acid digestion of the material in order to measure the Si content by ICP-AES. Three Si standards, a blank, and a matrix standard were prepared and submitted along with the Tank 40 samples. The following conclusions were drawn from the analytical results reported here: (1) The elemental composition of this sample and the analyses conducted here are reasonable and consistent with DWPF batch data measurements; (2) There was no measurable Si in samples of Tank 40 decant; and (3) Ag and the Ru, Rh, and Pd noble metal concentrations agree well with the estimate used for the SB4 70/30 blend of SB3 and Tank 51 performed in the SRNL Shielded Cells.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

VARIABILITY STUDY WITH FRIT 510 TO SUPPORT A SECOND TANK 40 DECANT

Sludge Batch 4 (SB4) is currently being processed in the Defense Waste Processing Facility (DWPF) using Frit 510. The slurry pumps in Tank 40 are experiencing in-leakage of bearing water, which is causing the sludge slurry in Tank 40 to become dilute at a rapid rate. Currently, the DWPF is removing this dilution water by performing caustic boiling during the Sludge Receipt and Adjustment Tank (SRAT) cycle. In order to alleviate prolonged SRAT cycle times, which may eventually impact canister production rates, the Liquid Waste Organization (LWO) performed a 100K gallon supernate decant of Tank 40 in April 2008. SRNL performed a supplemental glass variability study to support the April 2008 100K gallon decant incorporating the impact of coupled operations (addition of the Actinide Removal Process (ARP) stream). Recently LWO requested that SRNL assess the impact of a second decant (up to 100K gallon) to the Frit 510-SB4 system. This second decant occurred in June 2008. LWO provided nominal compositions on May 6, 2008 representing Tank 40 prior to the second decant, following the second decant, and the SB4 Heel prior to blending with Tank 51 to constitute SB5. Paper study assessments were performed for these options based on sludge-only and coupled operations processing (ARP addition), as well as possible Na{sub 2}O additions (via NaOH additions) to both flowsheets. A review of the ComProTM database relative to the compositional region defined by the projections after the second decant coupled with Frit 510 identified only a few glasses with similar glass compositions. These glasses were acceptable from a durability perspective, but did not sufficiently cover the new glass compositional region. Therefore, SRNL recommended that a supplemental variability study be performed to support the June 2008 Tank 40 decant. Glasses were selected for the variability study based on three sludge compositional projections (sludge-only, coupled and coupled + 2 wt% Na{sub 2}O) at waste loadings (WLs) of interest to DWPF (32%, 35% and 38%). These nine glasses were fabricated and characterized using chemical composition analysis, X-ray Diffraction (XRD) and the Product Consistency Test (PCT). All of the glasses that were selected for this study satisfy the Product Composition Control System (PCCS) criteria and are deemed processable and acceptable for the DWPF, except for the SB4VS2-03 (sludge-only at 38% WL) target composition. This glass fails the T{sub L} criterion and would not be considered processable based on Slurry Mix Evaporator (SME) acceptability decisions. The durabilities of all of the study glasses (both quenched and ccc) are well below that of the normalized leachate for boron (NL [B]) of the reference EA glass (16.695 g/L) and are predictable using the current PCCS models. Very little variation exists between the NL [B] of the quenched and ccc versions of the glasses. There is some evidence of a trend toward a less durable glass as WL increases for some of the sludge projections. Frit 510 is a viable option for the processing of SB4 after a second Tank 40 decant with or without the addition of products from the ARP stream as well as the 2 wt% Na{sub 2}O addition. The addition of ARP had no negative impacts on the acceptability and predictability of the variability study glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

STEADY STATE FLAMMABLE GAS RELEASE RATE CALCULATION AND LOWER FLAMMABILITY LEVEL EVALUATION FOR HANFORD TANK WASTE

This report assesses the steady state flammability level under off normal ventilation conditions in the tank headspace for 28 double-shell tanks (DST) and 149 single shell-tanks (SST) at the Hanford Site. Flammability was calculated using estimated gas release rates, Le Chatelier's rule, and lower flammability limits of fuels in an air mixture. This revision updates the hydrogen generation rate input data for al1 177 tanks using waste composition information from the Best Basis Inventory Detail Report (data effective as of August 4,2008). Assuming only barometric breathing, the shortest time to reach 25% of the lower flammability limit is 13 days for DSTs (i.e., tank 241-AZ-102) and 36 days for SSTs (i.e., tank 241-B-203). Assuming zero ventilation, the shortest time to reach 25% of the lower flammability limit is 12 days for DSTs (i.e., tank 241-AZ-102) and 34 days for SSTs (i.e., tank 241-B-203).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

STEADY STATE FLAMMABLE GAS RELEASE RATE CALCULATION AND LOWER FLAMMABILITY LEVEL EVALUATION FOR HANFORD TANK WASTE

This report assesses the steady state flammability level under off normal ventilation conditions in the tank headspace for 28 double-shell tanks (DST) and 149 single shell-tanks (SST) at the Hanford Site. Flammability was calculated using estimated gas release rates, Le Chatelier's rule, and lower flammability limits of fuels in an air mixture. This revision updates the hydrogen generation rate input data for all 177 tanks using waste composition information from the Best Basis Inventory Detail Report (data effective as of August 4,2008). Assuming only barometric breathing, the shortest time to reach 25% of the lower flammability limit is 11 days for DSTs (i.e., tank 241-AZ-10l) and 36 days for SSTs (i.e., tank 241-B-203). Assuming zero ventilation, the shortest time to reach 25% of the lower flammability limit is 10 days for DSTs (i.e., tank 241-AZ-101) and 34 days for SSTs (i.e., tank 241-B-203).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗