Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stock Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Creep and Fatigue Characterization of High Strength Alloy Thin Sections in Advanced CO2 Heat Exchangers

The objective of this work was to characterize and model elevated temperature creep and fatigue behavior for thin sheet and foil forms of gamma-prime strengthened alloys in wrought form and as-processed folded and brazed constructions. This work was motivated by the demanding temperature and pressure service conditions of the GEN3 Concentrated Solar Power (CSP) and supercritical CO2 (sCO2) power cycle working fluid. More specifically, the possibility of leveraging the superior creep strength of gamma-prime alloys in folded-fin and brazed-plate heat exchanger constructions. Gamma-prime alloys represent a step-change in raw-material strength over solid-solution strengthened alloys. And the folded-fin and brazed-plate heat exchanger architecture is lightweight and leverages cost-effective material stock forms. The investigation contained two parallel paths. (1) The first is referred to as a fundamental investigation where Oak Ridge National Laboratory conducts uniaxial creep testing on thin sheet and foil in wrought form. This effort aimed to serve as a benchmark against a relatively sparse existing database and a baseline comparison for path number 2. (2) The second path is referred to as the practical investigation where Brayton Energy manufactures plate-fin heat exchangers and performs pressurized creep and fatigue testing. This effort aimed to de-risk heat exchanger manufacturing process for service under sCO2 CSP conditions. A total of 14 uniaxial creep tests were completed using Haynes 282 thin sheet and foil. A variety of heat treatments were specified to coincide with path number 2. Baseline metallography of test samples and creep strength performance are contained. Benchmarks relatively to existing thick-form Haynes 282 are made, as well as to other thin-form Nickel-based superalloys. Description of a wrought-form modeling approach for thin gamma-prime alloys is also discussed. A total of 11 pressurized creep and fatigue tests were completed successfully with Haynes 282 heat exchanger prototypes. Manufacturing processing details, testing details, testing results, and failure analysis are discussed. Additionally, creep modeling techniques to predict failure are discussed, and modeling to support technological-to-market. In conclusion, Haynes 282 foils were demonstrated to yield rupture two-to-three orders of magnitude higher than Haynes 230 foils under similar conditions. And the manufactured heat exchanger prototypes demonstrated strength similar to the wrought constituents. Both of which contribute to elevated performance potential or cost savings in practice. Discussion is included.

14 SOLAR ENERGY↗

Quantifications of growth rate and particle size of magnesium silicate hydrate cement using small‐angle X‐ray scattering

The focus of recent research on cement binders has shifted to alternatives such as magnesium silicate hydrate (M-S-H) to mitigate the environmental impact of conventional concrete production. However, a detailed understanding of the morphology and growth rate of M-S-H, which informs its applicability as a cementing agent, is lacking. These properties are important as they influence cement hydration and consequently the development of macroscopic properties. Here, in this study, the particle size distribution and growth rate of M-S-H synthesized by mixing aqueous stock solutions were analyzed using synchrotron-based small-angle X-ray scattering. The reaction solutions contained dissolved magnesium and silicon with concentrations ranging from 2 to 500 mM, corresponding to saturation indices with respect to M-S-H endmembers, M 0.75 -S-H and M 1.50 -S-H, between 5.8 and 10.3. The precipitation rates of M-S-H align with affinity-based kinetic models and can be described by the following equations: For M 0.75 -S-H: 𝑟 M 0.75 −S−H =10 −9.54±0.70 ⁢(Ω$^{0.59±0.08}_{M_{0.75}⁢\textrm{SH}}$−1), and for M 1.50 -S-H: 𝑟 M 1.50 −S−H =10 −7.56±0.37 ⁢(Ω$^{0.34±0.04}_{M_{1.50}⁢\textrm{SH}}$−1), where 𝑟 is the rate in mol/L/s, and Ω represents the saturation ratio with respect to M-S-H. Moreover, we observed that changing the [Mg]/[Si] ratio affects particle size, a trend that cannot be fully explained by changes in the saturation index alone. These insights are critical for improving the predictability and control of cementation in concrete that utilizes M-S-H-based binders.

M-S-H↗

Building Performance Standards and Energy Code Alignment: Technical Brief

Building energy codes focus on building design, construction and renovation and have significantly increased building efficiency since the first national energy code was published in 1975. Most jurisdictions have energy codes based on ANSI/ASHRAE/IES Standard 90.1 (hereto referred to as Standard 90.1) and the International Energy Conservation Code (IECC). Compliance options available in these model energy codes include a prescriptive path, whole building performance paths – including IECC Total Building Performance (TBP), Standard 90.1 Energy Cost Budget (ECB) method and Performance Rating Method (PRM) – and system performance paths for envelope and heating, ventilation, and air-conditioning systems. Building performance standard (BPS) policies are an emerging policy tool used by jurisdictions to reduce the operational energy use or greenhouse gas (GHG) emissions of the existing commercial building stock. BPS policies vary widely between jurisdictions and are tailored to each location’s climate and energy goals. Intuitively, projects that met a recent edition of the energy code should comply with the BPS targets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Performance Standards and Energy Code Alignment - Technical Brief

Building energy codes focus on building design, construction and renovation and have significantly increased building efficiency since the first national energy code was published in 1975. Most jurisdictions have energy codes based on ANSI/ASHRAE/IES Standard 90.1 (hereto referred to as Standard 90.1) and the International Energy Conservation Code (IECC). Compliance options available in these model energy codes include a prescriptive path, whole building performance paths – including IECC Total Building Performance (TBP), Standard 90.1 Energy Cost Budget (ECB) method and Performance Rating Method (PRM) – and system performance paths for envelope and heating, ventilation, and air-conditioning systems. Building performance standard (BPS) policies are an emerging policy tool used by jurisdictions to reduce the operational energy use or greenhouse gas (GHG) emissions of the existing commercial building stock. BPS policies vary widely between jurisdictions and are tailored to each location’s climate and energy goals. Intuitively, projects that met a recent edition of the energy code should comply with the BPS targets. However, some new buildings may struggle with meeting the BPS for the following reasons: 1. Energy codes focus on the design of the building and its projected ability to perform efficiently, while BPS compliance is dependent on the actual ongoing performance of the building, considering variables like occupancy, operation, and maintenance. 2. There are significant differences in the methodologies used to determine BPS compliance versus code compliance, including how each handles compliance metrics, handling of building amenities, and renewable energy generation. 3. The prescriptive compliance path in the energy code is based on performance of individual building components, as opposed to the performance compliance path which accounts for holistic building design strategies and interdependent building systems. This can result in a significant variability in post-occupancy performance for buildings built using the prescriptive path. Designs on the lower end of the permitted efficiency range may struggle with meeting the BPS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modelled land use and land cover change emissions – a spatio-temporal comparison of different approaches

Abstract. Quantifying the net carbon flux from land use and land cover changes (fLULCC) is critical for understanding the global carbon cycle and, hence, to support climate change mitigation. However, large-scale fLULCC is not directly measurable and has to be inferred from models instead, such as semi-empirical bookkeeping models and process-based dynamic global vegetation models (DGVMs). By definition, fLULCC estimates are not directly comparable between these two different model types. As an important example, DGVM-based fLULCC in the annual global carbon budgets is estimated under transient environmental forcing and includes the so-called loss of additional sink capacity (LASC). The LASC results from the impact of environmental changes on land carbon storage potential of managed land compared to potential vegetation and accumulates over time, which is not captured in bookkeeping models. The fLULCC from transient DGVM simulations, thus, strongly depends on the timing of land use and land cover changes mainly because LASC accumulation is cut off at the end of the simulated period. To estimate the LASC, the fLULCC from pre-industrial DGVM simulations, which is independent of changing environmental conditions, can be used. Additionally, DGVMs using constant present-day environmental forcing enable an approximation of bookkeeping estimates. Here, we analyse these three DGVM-derived fLULCC estimations (under transient, pre-industrial, and present-day forcing) for 12 models within 18 regions and quantify their differences as well as climate- and CO2-induced components and compare them to bookkeeping estimates. Averaged across the models, we find a global fLULCC (under transient conditions) of 2.0±0.6 PgC yr−1 for 2009–2018, of which ∼40 % are attributable to the LASC (0.8±0.3 PgC yr−1). From 1850 onward, the fLULCC accumulated to 189±56 PgC with 40±15 PgC from the LASC. Around 1960, the accumulating nature of the LASC causes global transient fLULCC estimates to exceed estimates under present-day conditions, despite generally increased carbon stocks in the latter. Regional hotspots of high cumulative and annual LASC values are found in the USA, China, Brazil, equatorial Africa, and Southeast Asia, mainly due to deforestation for cropland. Distinct negative LASC estimates in Europe (early reforestation) and from 2000 onward in the Ukraine (recultivation of post-Soviet abandoned agricultural land), indicate that fLULCC estimates in these regions are lower in transient DGVM compared to bookkeeping approaches. Our study unravels the strong dependence of fLULCC estimates on the time a certain land use and land cover change event happened to occur and on the chosen time period for the forcing of environmental conditions in the underlying simulations. We argue for an approach that provides an accounting of the fLULCC that is more robust against these choices, for example by estimating a mean DGVM ensemble fLULCC and LASC for a defined reference period and homogeneous environmental changes (CO2 only).

54 ENVIRONMENTAL SCIENCES↗

The evolution of AGN's at x ray wavelengths

The cosmological evolution and the Luminosity Function (LF) of x-ray selected Active Galactic Nuclei (AGN) are discussed. The sample used is extracted from the Einstein Observatory Extended Medium Sensitivity Survey (EMSS) and consists of more than 420 objects. Preliminary results from the Rosat all sky survey data confirm the correctness of the optical identification of the EMSS sources, thus giving confidence to the results obtained from the analysis of the AGN sample. The XLF observed at different redshifts gives direct evidence of cosmological evolution. Data were analyzed within the framework of luminosity evolution models and the two most common evolutionary forms were considered. Luminosity dependent evolution is required if the evolution function has the exponential form, whereas the simpler pure luminosity evolution model is still acceptable if the evolution function has the power law form. Using the whole sample of objects the number counts and the devolved XLF were derived. A comparison of the EMSS Data with preliminary Rosat results indicates an overall agreement.

Maccacaro, Tommaso↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New York Ecological Conservation: Evaluating Agricultural Conservation Easement Impact Using Earth Observations to Examine Avoided Soil Carbon Loss to Development

Farmland provides ecosystems and communities with services ranging from habitat conservation to food security. As total U.S. farmland continues to decline, agricultural lands near urban areas are especially vulnerable. Our project partners—Finger Lakes Land Trust, Genesee Land Trust, and Saratoga Preserving Land and Nature (PLAN)—can use study results to better profile farmland vulnerability, issuing conservation easements to protect maximum acreage in Saratoga County and the Finger Lakes Region of New York. Multiple existing studies effectively use remote sensing imagery to analyze historical land cover and forecast future change. This study examined soil carbon stocks and land cover change to estimate avoided soil carbon loss. We also predicted farmland vulnerability. We completed these analyses using European Space Agency (ESA) and NASA Earth observations that include Landsat 5 Thematic Mapper (TM), Landsat 8 Operational Land Imager (OLI), Landsat 9 OLI-2, Sentinel-2 Multispectral Instrument (MSI), and Suomi National Polar-Orbiting Partnership (NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) for nighttime lights data that aided in the land change model analysis. We determined that the conversion of agriculture to development from 1990 to 2022 occurred at rates of 0.91% (Finger Lakes) and 7% (Saratoga). Urban development is predicted to increase surrounding urban centers through 2030 and 2050. We also estimate that between 26.5 and 348,101 kilotons (Finger Lakes) and 3.7 and 58,006 kilotons (Saratoga) of soil carbon losses have been avoided through agricultural easements. Findings from this study will support our partners in determining agricultural conservation easement benefits and prioritizing the acquisition of future easement sites.

Agriculture↗

Deeply Rooted: Evaluating Plant Rooting Depth as a Means for Enhanced Soil Carbon Sequestration (Full Technical Report)

Soils store three times as much carbon (C) as the atmosphere, but are not at capacity, and enhanced soil C storage is considered an essential strategy to mitigate rising atmospheric CO 2 levels. Agricultural soils have experienced substantial C loss in the past century due to poor agricultural practices and erosion. A shift towards deep-rooting crops and low-impact soil management could potentially increase long-term sequestration of C fixed by plants and stored in their root tissues, particularly for crops that have naturally deep root systems (>1 meter). A substantial amount of the CO 2 taken up by plants is allocated to their root systems, and because C deposited in deep soil layers has a longer residence time (up to millennia, in contrast to C deposited in topsoils), C increases at depth may have better long-term C sequestration potential than topsoils. However, the accrual, turnover, and stabilization of C in subsoils is a critical knowledge gap. We investigated a deeply rooted plant, switchgrass (Panicum virgatum), as a means of increasing carbon stocks in marginal and agricultural soils. We hypothesized that deep (>30 cm) SOC stocks would be greater under bioenergy crops relative to stocks under shallow-rooted conventional crop cover. To test this hypothesis, we compared soil depth profiles beneath deeply rooted switchgrass (cultivated for 4-30 years) and paired shallowrooted annual controls. We studied 12 field sites, 3 that were collected in 2018 before the start of the project as part a Department of Energy (DOE) Sustainable Biofuels study, and 9 that we collected in 2019 on a national field sampling campaign across the eastern US. In our publication from the 2018 study, which was written in collaboration with the LLNL Soil Microbiome Scientific Focus Area (SFA), we found that C stocks increased under switchgrass, but that the increases were dependent on soil texture. In the 2019 study, we found that carbon accrual tended to occur most consistently in low C soil in the southern US, which could indicate that perennial grasses may be a viable strategy to increase SOC in marginals soils in this region. We have published two studies from the 2019 sampling campaign thus far, we measured microbial growth parameters that will aid in modeling subsoil carbon cycling, and we found that switchgrass appears to move water upward in the soil profile and could promote drought tolerance, which a phenomenon commonly performed by trees known as ‘hydraulic redistribution;’ our study is the first to show this can occur in deep-rooted grasses. Finally, we published a modeling paper in collaboration with the LLNL Soil Microbiome SFA, where we found that poorly crystalline minerals are abundant and strongly correlated with organic C in geographically limited zones with enhanced weathering rates. Our results will inform technological development in the agricultural carbon sequestration sector as well as future negative emissions policies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Feasibility Study of a Lunar Analog Bed Rest Model

The purpose of this study was to determine the feasibility of using a 9.5deg head-up tilt bed rest model to simulate the effects of the 1/6 g load to the human body that exists on the lunar surface. The lunar analog bed rest model utilized a modified hospital bed. The modifications included mounting the mattress on a sled that rolled on bearings to provide freedom of movement. The weight of the sled was off-loaded using a counterweight system to insure that 1/6 body weight was applied along the long axis (z-axis) of the body. Force was verified through use of a force plate mounted at the foot of the bed. A seating assembly was added to the bed to permit periods of sitting. Subjects alternated between standing and sitting positions throughout the day. A total of 35% of the day was spent in the standing position and 65% was spent sitting. In an effort to achieve physiologic fluid shifts expected for a 1/6 G environment, subjects wore compression stockings and performed unloaded foot and ankle exercises. Eight subjects (3 females and 5 males) participated in this study. Subjects spent 13 days in the pre-bed rest phase, 6 days in bed rest and 3 days post bed rest. Subjects consumed a standardized diet throughout the study. To determine feasibility, measures of subject comfort, force and plasma volume were collected. Subject comfort was assessed using a Likert scale. Subjects were asked to assess level of comfort (0-100) for 11 body regions and provide an overall rating. Results indicated minimal to no discomfort as most subjects reported scores of zero. Force measures were performed for each standing position and were validated against subject s calculated 1/6 body weight (r(sup 2) = 0.993). The carbon monoxide rebreathing technique was used to assess plasma volume during pre-bed rest and on the last day of bed rest. Plasma volume results indicated a significant decrease (p = 0.001) from pre to post bed rest values. Subjects lost on average 8.3% (sd = 6.1%) during the bed rest phase. Findings from this feasibility study indicated that 1) the lunar analog bed rest model was well tolerated by subjects; 2) a 1/6 load was accurately applied to the z-axis of the body; and 3) plasma volume losses could be achieved in a head-up tilt bed rest model. Future work to refine this model should include extending the duration of bed rest to mimic longer mission durations and a comprehensive assessment of the physiological responses to this bed rest analog.

Cromwell, Ronita L.↗

Housing-Performance Atlas of Baltimore Row Homes: Archetype-Based Multi-Hazard Baseline of Energy, Heat, Survivability, and Durability

Baltimore’s historic row-home neighborhoods face escalating risks to energy, heat, and durability under intensifying climate stress. This study develops a Housing-Performance Atlas that quantifies multi-hazard performance for eight representative archetypes using DesignBuilder/EnergyPlus Version 7.3.1.003, under Baltimore TMY3 boundary conditions. Performance is evaluated across the following four adaptation domains: energy use intensity, passive survivability during 72 h outage events, roof overheating exposure (>150 °F exceedance hours), and material service life derived from ISO 15686 and synthesized into Lean and Full Deficit Indices for comparative resilience ranking. Results show that EUI ranged from 46.7 to 67.6 kBtu ft −2 ·yr −1 , survivability from 0 to 23 h, and roof temperatures exceeded 150 °F for 150–210 h, shortening roof service life by up to 10 years. Composite Lean and Full Deficit Indices ranged 7.8–92.4, ranking Model 5 (end-unit, flat roof, two-story with basement) as the most resilient configuration and Model 8 (end-unit, pitched roof, three-story above-grade) as the least resilient due to compounded overheating and energy losses. Heat-related domains accounted for nearly 70% of overall resilience deficits, confirming thermal safety and roof reflectivity as retrofit priorities. The Housing-Performance Atlas establishes a reproducible diagnostic framework linking simulation, service life, and resilience metrics to guide cost-effective, climate-responsive retrofits in Baltimore’s aging urban housing stock.

Housing-Performance atlas↗

Artificial Intelligence–Enabled Digital Twin for U.S. Cities

Over 50 participants—including national laboratory researchers, academic scholars, industry representatives, and stakeholders from the City of Chicago—convened in person and online to assess the readiness and potential of an Artificial Intelligence–Enabled Digital Twin (AIDT) for urban systems, with the Greater Chicago area serving as the benchmark location. The workshop underscored that the Chicago Urban Integrated Field Laboratory provides an unparalleled testbed for developing and validating urban DTs—combining dense, multiscale observations, advanced physics-based and AI modeling capabilities, and strong stakeholder and industry engagement. Discussions highlighted available datasets, AI architectures for high resolution, multipurpose urban DTs, key applications, and near- and long-term priorities for scaling this framework within Chicago and to other U.S. and global cities.

AIDT↗

OpenStudio Development, Maintenance, and Support

BEM is a key decision support tool for energy efficiency, demand flexibility, and electrification at the building and building stock levels. The OpenStudio SDK maximizes the value of BEM by enhancing the productivity, consistency, and transparency with which it is applied. OpenStudio enables BEM experts to encapsulate domain and process knowledge in such a way that makes it usable by a range of stakeholders.

BEM↗

Modeling interval trendlines: Symbolic singular spectrum analysis for interval time series

Abstract In this article we propose an extension of singular spectrum analysis for interval‐valued time series. The proposed methods can be used to decompose and forecast the dynamics governing a set‐valued stochastic process. The resulting components on which the interval time series is decomposed can be understood as interval trendlines, cycles, or noise. Forecasting can be conducted through a linear recurrent method, and we devised generalizations of the decomposition method for the multivariate setting. The performance of the proposed methods is showcased in a simulation study. We apply the proposed methods so to track the dynamics governing the Argentina Stock Market (MERVAL) in real time, in a case study over a period of turbulence that led to discussions of the government of Argentina with the International Monetary Fund.

de Carvalho, Miguel↗

C2C Expert Match Technical Assistance: City of Reading, Pennsylvania [Slides]

The City of Reading, located in southeastern Pennsylvania, is the main city in the Greater Reading Area and the county seat of Berks County, with a population of approximately 95,112 as of 2020. Historically a disinvested manufacturing community, it has a poverty rate of around 40%, a housing stock averaging 90 years old, and an owner-occupied housing rate below 40%. In 2019, Reading adopted a resolution to achieve 100% renewable energy by 2050. The city aims to transition residential, small commercial, and small manufacturing sectors to renewable energy for electricity and heating, bypassing natural gas. This C2C Expert Match aimed to improve the energy efficiency and comfort of older rowhomes in Reading, which often rely on home heating oil and lack cooling systems. A representative energy model of a typical rowhome was developed to evaluate retrofit strategies focused on reducing overheating risk, as well as the potential impacts of heat pump installation. Additionally, resources such as case studies and best practices on energy efficiency, thermal resilience, and electrification retrofits were gathered to support the implementation of effective measures in the community.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy cost savings and expected payback for Re-tuning the controls of US Army buildings

The Headquarters Department of the Army (HQDA) sponsored a study to determine the national impact of deploying the Re-tuning™ methodology in 5 buildings types that account for over 40% of the Army’s conditioned building stock. Re-tuning is a systematic process that improves operational efficiency and reduces energy consumption at no- or low-cost through the building automation system (BAS) by correcting operational problems that plague buildings. The study relied on successful demonstration of the re-tuning methodology at 4 pilot US Army installations that informed a holistic effort that included simulating 12 individual re-tuning energy efficiency measures (EEMs) and 6 packages of EEMs in 5 selected Army building prototype models that represent 311 million ft2 (28.9 million m2) of the Army’s conditioned floor space. Both the baseline buildings and the packages were customized to capture the expected outcomes of re-tuning a diverse set of buildings. The study highlighted the benefit of individual re-tuning EEMs and economics of implementing packages of EEMs in applicable Army buildings across 16 climates and 2 building vintages. The average whole-building energy savings ranged from 10.8% to 40.5% by building type, with the company operations facility (COF) building having the highest value proposition from re-tuning. In addition, the study reveals that all large office (LO) buildings in the Army are economical to re-tune. The total modeled cost savings potential for re-tuning the five building types across the US Army is $204/1,000 sf ($220/100 m2), or $64M annually. This cost savings represents 5.6% of all the Army’s energy expenditures.

Fernandez, Nicholas EP↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Corn stover harvest reduces soil CO 2 fluxes but increases overall C losses

Abstract Harvesting corn ( Zea mays L.) stover for use as bioenergy feedstock may provide short‐term economic benefits and perhaps improve grain yield in continuous corn systems, but excessive stover removal may lead to long‐term depletion of soil C stocks. To better quantify the impacts of stover harvest on the soil C balance, we investigated CO 2 fluxes under three harvest treatments (none, moderate, and high) in three continuous corn systems: (a) no tillage and no biochar applications, (b) chisel plowing with biochar amendments, and (c) chisel plowing without biochar amendments were quantified. We sampled static chambers 14, 13, and 15 times in 2010, 2011, and 2012, respectively, and the measurements were used to calibrate the Agricultural Production Systems sIMulator model. Although CO 2 ‐C emissions did not differ among the three systems, both moderate (approximately 30%) and high (approximately 60%) stover removal rates reduced simulated CO 2 ‐C emissions by nearly 10% and more than 22%, respectively. Despite these reductions in CO 2 flux, the sum of CO 2 ‐C and stover C exceeded CO 2 ‐C losses in those plots without stover removal. This finding suggested soil C depletion was occurring for the soil and crop management practices used, even though depletion was not evident after 3 years. Application of biochar increased soil C levels, suggesting it may be able to offset some C losses. We conclude that for sustainable, highly productive agroecosystems that include stover harvest, all agronomic practices must be optimized to minimize C losses and maintain soil quality.

54 ENVIRONMENTAL SCIENCES↗