Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Measurement of the Antineutrino Spectrum from U 235 Fission at HFIR with PROSPECT

This Letter reports the first measurement of the 235 U ν¯ e energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW th highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678 ± 304 (stat.) ν¯ e -induced inverse beta decays (IBD), the largest sample from HEU fission to date, 99% of which are attributed to 235 U. Despite broad agreement, comparison of the Huber 235 U model to the measured spectrum produces a χ 2 /ndf = 51.4/31, driven primarily by deviations in two localized energy regions. As a result, the measured 235 U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the ν¯ e energy region of 5-7MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct Measurement of the Nickel Spectrum in Cosmic Rays in the Energy Range from 8.8 GeV/$\mathcal{n}$ to 240 GeV/$\mathcal{n}$ with CALET on the International Space Station

The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other transiron elements; therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than ~ 3 GeV/n are available at present in the literature, and they are affected by strong limitations in both energy reach and statistics. In this Letter, we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n , carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z = 40 ). The particle’s energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This Letter follows our previous measurement of the iron spectrum [O. Adriani et al. (CALET Collaboration), Phys. Rev. Lett. 126, 241101 (2021).], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV/n our present data are compatible within the errors with a single power law with spectral index -2.51 ± 0.07 .

79 ASTRONOMY AND ASTROPHYSICS↗

Scheduled Sequential Compressed Spectrum Sensing for Wideband Cognitive Radios

The support for high data rate applications with the cognitive radio technology necessitates wideband spectrum sensing. However, it is costly to apply long-term wideband sensing and is especially difficult in the presence of uncertainty, such as high noise, interference, outliers, and channel fading. In this paper, we propose scheduling of sequential compressed spectrum sensing which jointly exploits compressed sensing (CS) and sequential periodic detection techniques to achieve more accurate and timely wideband sensing. Instead of invoking CS to reconstruct the signal in each period, our proposed scheme performs backward grouped-compressed-data sequential probability ratio test (backward GCD-SPRT) using compressed data samples in sequential detection, while CS recovery is only pursued when needed. This method on one hand significantly reduces the CS recovery overhead, and on the other takes advantage of sequential detection to improve the sensing quality. Furthermore, we propose (a) an in-depth sensing scheme to accelerate sensing decision-making when a change in channel status is suspected, (b) a block-sparse CS reconstruction algorithm to exploit the block sparsity properties of wide spectrum, and (c) a set of schemes to fuse results from the recovered spectrum signals to further improve the overall sensing accuracy. Finally, extensive performance evaluation results show that our proposed schemes can significantly outperform peer schemes under sufficiently low SNR settings.

42 ENGINEERING↗

Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

Purpose: Differential phase contrast CT (DPC-CT) is emerging as a new technology to improve the contrast sensitivity of conventional attenuation-based CT. The noise equivalent quanta as a function over spatial frequency, i.e., the spectrum of noise equivalent quanta NEQ(k), is a decisive indicator of the signal and noise transfer properties of an imaging system. In this work, we derive the functional form of NEQ(k) in DPC-CT. Via system modeling, analysis, and computer simulation, we evaluate and verify the derived NEQ(k) and compare it with that of the conventional attenuation-based CT. Methods: The DPC-CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated through Fresnel and Fourier analysis. A monochromatic x-ray source (30 keV) is assumed to exclude any system imperfection and interference caused by scatter and beam hardening, while a 360 Degree-Sign full scan is carried out in data acquisition to avoid any weighting scheme that may disrupt noise randomness. Adequate upsampling is implemented to simulate the x-ray beam's propagation through the gratings G{sub 1} and G{sub 2} with periods 8 and 4 {mu}m, respectively, while the intergrating distance is 193.6 mm (1/16 of the Talbot distance). The dimensions of the detector cell for data acquisition are 32 Multiplication-Sign 32, 64 Multiplication-Sign 64, 96 Multiplication-Sign 96, and 128 Multiplication-Sign 128 {mu}m{sup 2}, respectively, corresponding to a 40.96 Multiplication-Sign 40.96 mm{sup 2} field of view in data acquisition. An air phantom is employed to obtain the noise power spectrum NPS(k), spectrum of noise equivalent quanta NEQ(k), and detective quantum efficiency DQE(k). A cylindrical water phantom at 5.1 mm diameter and complex refraction coefficient n= 1 -{delta}+i{beta}= 1 -2.5604 Multiplication-Sign 10{sup -7}+i1.2353 Multiplication-Sign 10{sup -10} is placed in air to measure the edge transfer function, line spread function and then modulation transfer function MTF(k), of both DPC-CT and the conventional attenuation-based CT. The x-ray flux is set at 5 Multiplication-Sign 10{sup 6} photon/cm{sup 2} per projection and observes the Poisson distribution, which is consistent with that of a micro-CT for preclinical applications. Approximately 360 regions, each at 128 Multiplication-Sign 128 matrix, are used to calculate the NPS(k) via 2D Fourier transform, in which adequate zero padding is carried out to avoid aliasing in noise. Results: The preliminary data show that the DPC-CT possesses a signal transfer property [MTF(k)] comparable to that of the conventional attenuation-based CT. Meanwhile, though there exists a radical difference in their noise power spectrum NPS(k) (trait 1/|k| in DPC-CT but |k| in the conventional attenuation-based CT) the NEQ(k) and DQE(k) of DPC-CT and the conventional attenuation-based CT are in principle identical. Conclusions: Under the framework of ideal observer study, the joint signal and noise transfer property NEQ(k) and detective quantum efficiency DQE(k) of DPC-CT are essentially the same as those of the conventional attenuation-based CT. The findings reported in this paper may provide insightful guidelines on the research, development, and performance optimization of DPC-CT for extensive preclinical and clinical applications in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-19A-07: The Effect of Particle Tracking Step Size Limit On Monte Carlo- Computed LET Spectrum of Therapeutic Proton Beams

Purpose: To investigate the effect of charged particle tracking step size limit in the determination of the LET spectrum of therapeutic proton beams using Monte Carlo simulations. Methods: The LET spectra at different depths in a water phantom from a 79.7 MeV spot-scanning proton beam were calculated using Geant4. Five different tracking step limits 0.5 mm, 0.1 mm, 0.05 mm, 0.01 mm and 1 μm were adopted. The field size was set to 10×10 cm{sup 2} on the isocenter plane. A 40×40×6 cm{sup 3} water phantom was modelled as the irradiation target. The voxel size was set to 1×1×0.5 mm{sup 3} to obtain high resolution results. The LET spectra were scored ranging from 0.01 keV/μm to 10{sup 4}keV/μm in the logarithm scale. In addition, the proton energy spectra at different depths were also scored. Results: The LET spectra calculated using different step size limits were compared at four depths along the Bragg curve. At any depths, the spread of the LET spectra increases with the decrease of step size limit. In the dose buildup region (z = 1.9 cm) and in the region proximal to the Bragg peak (z = 3.95 cm), the frequency mean LET does not vary with decreasing step size limit. At Bragg peak (z = 4.75 cm) and in the distal edge (z = 4.85 cm), frequency mean LET decreases with decreasing step size limit. The energy spectrum at any specified depths does not vary with the step size limit. Conclusion: The calculated LET has a spectral distribution rather than a single value at any depths along the Bragg curve and the spread of the computed spectrum depends on the tracking step limit. Incorporating the LET spectrum distribution into the robust IMPT optimization plan may provide more accurate biological dose distribution than using the dose- or fluence-averaged LET. NIH Program Project Grant P01CA021239.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-557: Monte Carlo Modeling of Philips RT-250 Orthovoltage Unit for Beam Spectrum Modulation

Purpose: To develop and validate a Monte Carlo (MC) model of a Phillips RT-250 orthovoltage unit to test various beam spectrum modulation strategies for in vitro/vivo studies. A model of this type would enable the production of unconventional beams from a typical orthovoltage unit for novel therapeutic applications such as gold nanoparticle-aided radiotherapy. Methods: The MCNP5 code system was used to create a MC model of the head of RT-250 and a 30 × 30 × 30 cm{sup 3} water phantom. For the x-ray machine head, the current model includes the vacuum region, beryllium window, collimators, inherent filters and exterior steel housing. For increased computational efficiency, the primary x-ray spectrum from the target was calculated from a well-validated analytical software package. Calculated percentage-depth-dose (PDD) values and photon spectra were validated against experimental data from film and Compton-scatter spectrum measurements. Results: The model was validated for three common settings of the machine namely, 250 kVp (0.25 mm Cu), 125 kVp (2 mm Al), and 75 kVp (2 mm Al). The MC results for the PDD curves were compared with film measurements and showed good agreement for all depths with a maximum difference of 4 % around dmax and under 2.5 % for all other depths. The primary photon spectra were also measured and compared with the MC results showing reasonable agreement between the two, validating the input spectra and the final spectra as predicted by the current MC model. Conclusion: The current MC model accurately predicted the dosimetric and spectral characteristics of each beam from the RT-250 orthovoltage unit, demonstrating its applicability and reliability for beam spectrum modulation tasks. It accomplished this without the need to model the bremsstrahlung xray production from the target, while significantly improved on computational efficiency by at least two orders of magnitude. Supported by DOD/PCRP grant W81XWH-12-1-0198.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise power spectrum of the fixed pattern noise in digital radiography detectors

Purpose: The fixed pattern noise in radiography image detectors is caused by various sources. Multiple readout circuits with gate drivers and charge amplifiers are used to efficiently acquire the pixel voltage signals. However, the multiple circuits are not identical and thus yield nonuniform system gains. Nonuniform sensitivities are also produced from local variations in the charge collection elements. Furthermore, in phosphor-based detectors, the optical scattering at the top surface of the columnar CsI growth, the grain boundaries, and the disorder structure causes spatial sensitivity variations. These nonuniform gains or sensitivities cause fixed pattern noise and degrade the detector performance, even though the noise problem can be partially alleviated by using gain correction techniques. Hence, in order to develop good detectors, comparative analysis of the energy spectrum of the fixed pattern noise is important. Methods: In order to observe the energy spectrum of the fixed pattern noise, a normalized noise power spectrum (NNPS) of the fixed pattern noise is considered in this paper. Since the fixed pattern noise is mainly caused by the nonuniform gains, we call the spectrum the gain NNPS. We first asymptotically observe the gain NNPS and then formulate two relationships to calculate the gain NNPS based on a nonuniform-gain model. Since the gain NNPS values are quite low compared to the usual NNPS, measuring such a low NNPS value is difficult. By using the average of the uniform exposure images, a robust measuring method for the gain NNPS is proposed in this paper. Results: By using the proposed measuring method, the gain NNPS curves of several prototypes of general radiography and mammography detectors were measured to analyze their fixed pattern noise properties. We notice that a direct detector, which is based on the a-Se photoconductor, showed lower gain NNPS than the indirect-detector case, which is based on the CsI scintillator. By comparing the gain NNPS curves of the indirect detectors, we could analyze the scintillator properties depending on the techniques for the scintillator surface processing. Conclusions: A robust measuring method for the NNPS of the fixed pattern noise of a radiography detector is proposed in this paper. The method can measure a stable gain NNPS curve, even though the fixed pattern noise level is quite low. From the measured gain NNPS curves, we can compare and analyze the detector properties in terms of producing the fixed pattern noise.

60 APPLIED LIFE SCIENCES↗

Contribution from cosmological scalar perturbations to the angular velocity spectrum of extragalactic sources

The possibility of the influence of adiabatic scalar perturbations on the angular velocity spectrum of extragalactic sources is considered. The multipole expansion coefficients of the angular velocity field in terms of vector spherical harmonics are calculated. We show that there is no contribution from adiabatic perturbations to the angular spectrum for a spatially flat Universe at the dusty stage, while there is a contribution only to the electric multiple coefficients at the stage of {Lambda}-term domination. The cases of long-wavelength and short-wavelength perturbations are considered separately. The relationship between the multipole angular velocity spectrum and the primordial scalar perturbation spectrum is discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Calculation of the spectrum of quasiparticle electron excitations in organic molecular semiconductors

A quasiparticle electronic spectrum belongs to the characteristics of nanoobjects that are most important for applications. The following methods of calculating the electronic spectrum are analyzed: the Kohn-Sham equations of the density functional theory (DFT), the hybrid functional method, the GW approximation, and the Lehmann approximation used in the spectral representation of one-electron Green’s function. The results of these approaches are compared with the data of photoemission measurements of benzene, PTCDA, and phthalocyanine (CuPc, H{sub 2}Pc, FePc, PtPc) molecules, which are typical representatives of organic molecular semiconductors (OMS). This comparison demonstrates that the Kohn-Sham equations of DFT incorrectly reproduce the electronic spectrum of OMS. The hybrid functional method correctly describes the spectrum of the valence and conduction bands; however, the HOMO-LUMO gap width is significantly underestimated. The correct gap width is obtained in both the GW approximation and the Lehmann approach, and the total energy in this approach can be calculated in the local density approximation of DFT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Peculiarities of FeSi phonon spectrum induced by a change of atomic volume

We analyze in detail the results of experimental investigations of the evolution of the thermal vibration spectra for iron atoms in iron monosilicide FeSi depending on two external parameters, viz., temperature T (in the range 46–297 K at pressure P = 0.1 MPa) and pressure P (in the range 0.1 MPa–43 GPa at temperature T = 297 K), obtained by nuclear inelastic scattering of synchrotron radiation. The decrease of the atomic volume is accompanied by a rearrangement of the phonon spectrum, which is manifested, in particular, in the splitting of the low-energy peak in the spectrum and in an increase of the energy for all phonons. The changes of the average energy of the iron atom vibrational spectrum and of the Debye energy with decreasing atomic volume are analyzed. Different versions of FeSi electron spectrum variation, which can be used to explain the observed phonon anomalies, are considered.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of the QCD spectrum and chiral symmetry breaking with varying quark masses

The meson spectrum of QCD is studied in the framework of nonperturbative QCD as a function of varying quark masses m{sub q}. It is shown that the total spectrum consists of two branches: 1) the standard one, which may be called the flux-tube spectrum, depending approximately linearly on m{sub q}, and 2) the chiral symmetry breaking (CSB) spectrum for pseudoscalar (PS) flavor nonsinglet mesons with mass dependence {radical}m{sub q}. The formalism for PS mesons is derived from the QCD Lagrangian with m{sub q} corrections, and a unified form of the PS propagator was derived. It is shown that the CSB branch of PS mesons joins to the flux-tube branch at around m{sub q} = 200 MeV. All these results are in close correspondence with recent numerical data on large lattices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of the mass spectrum of the bound state in the framework of the relativistic hamiltonian approach

We propose one a variant of calculation of the energy spectrum of bound state systems with relativistic corrections. In the framework of quantum field theory, an expression that takes into account relativistic corrections to the mass of the bound state with a known nonrelativistic pair interaction potential is proposed on the basis of calculating the asymptotic behavior of correlation functions of the corresponding field currents with the necessary quantum numbers. Excluding the time variables allows one to determine nonperturbative corrections to the interaction potential. The following results have been obtained in the framework of this approach. The nonperturbative corrections arising due to the relativistic nature of a system to the interaction Hamiltonian are determined. The dependence of the constituent mass of bound-state forming particles on the free state mass and on the orbital and radial quantum numbers is analytically derived. The energy level shift of muonic hydrogen taking into account relativistic corrections is calculated. The energy spectrum of a wide class of potentials that describe the Coulomb bound state is analytically derived with relativistic corrections. The mass spectrum of the glueballs and the constituent masses of the gluons are analytically calculated taking into account spin-orbit, spin—spin, and tensor interactions. Our numerical results have shown very good agreement with the lattice data. Taking into account nonperturbative and nonlocality characters of interactions, the mass spectrum of the mesons consisting of light-light and light-heavy quarks with orbital and radial excitations is determined. Our results show that good agreement with the experimental data for the slope and the intercept of the Regge trajectory can be obtained only taking into account the nonperturbative and the nonlocal characters of interactions. The dependences of the constituent masses of constituent particles on the masses of a free state are certain. When quarks are light, then the difference between current and valent masses of quarks is greater than valent masses of quarks, and when quarks are heavy, then the difference between these masses is insignificant. One of the alternative variants of taking nonlocality into account has been suggested for the definition of properties of hadrons at large distances. The dependence of the constituent masses of constituent particles on the radius of confinement is determined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamics of the ion energy spectrum in EUV-induced hydrogen plasma

The dynamics of the ion energy spectrum in low-pressure (10–100 Pa) hydrogen plasma induced by extreme ultraviolet (EUV) pulses in the wavelength range of 10–20 nm was studied experimentally. The plasma was generated under cathode irradiation due to both direct gas ionization by EUV photons and impact ionization by high-energy secondary electrons. The dynamics of the spectra of ions incident on the cathode was measured using a time-resolved retarding field energy analyzer. It is shown that the ion spectrum dynamics is completely determined by the time evolution of the cathode sheath. At low gas pressures (<20 Pa), the ion spectrum at early moments after the EUV pulse has a peaked shape, typical of a collisionless plasma sheath, and is mainly determined by the cathode voltage. As the pressure increases, the peak broadens and low energy ions appear in the spectrum due to ion collisions in the cathode sheath. An increase in the role of collisions with decreasing plasma density is also observed in the time evolution of ion spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of inhomogeneous broadening and deliberately introduced disorder on the width of the lasing spectrum of a quantum dot laser

Analytical expressions for the shape and width of the lasing spectra of a quantum-dot (QD) laser in the case of a small (in comparison with the spectrum width) homogeneous broadening of the QD energy levels have been obtained. It is shown that the dependence of the lasing spectrum width on the output power at room temperature is determined by two dimensionless parameters: the width of QD distribution over the optical-transition energy, normalized to temperature, and the ratio of the optical loss to the maximum gain. The optimal dimensions of the laser active region have been found to obtain a specified width of the emission spectrum at a minimum pump current. The possibility of using multilayer structures with QDs to increase the lasing spectrum's width has been analyzed. It is shown that the use of several arrays of QDs with deliberately variable optical-transition energies leads to broadening of the lasing spectra; some numerical estimates are presented.

36 MATERIALS SCIENCE↗

Cathodoluminescence Spectrum Imaging Software [SWR-11-08]

The software developed for spectrum imaging is applied to the analysis of the spectrum series generated by our cathodoluminescence instrumentation. This software provides advanced processing capabilities s such: reconstruction of photon intensity (resolved in energy) and photon energy maps, extraction of the spectrum from selected areas, quantitative imaging mode, pixel-to-pixel correlation spectrum line scans, ASCII, output, filling routines, drift correction, etc.

Romero, ManuelJ.↗

NSVA-3 Spectrum Adjustment Code

SAND2025-03756O The NSVA-3 Spectrum Adjustment Code performs a least-square spectrum adjustment on multiple neutron fields and provides a best-estimate neutron spectrum and associated uncertainty. The code was developed to perform a least-square spectrum adjustment for neutron benchmark fields. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Griffin, Patrick↗

Uranium and plutonium prompt-fission-neutron energy spectrum (PFNS) from the analysis of NTS NUEX data

The neutron experiment (NUEX) was a common diagnostic on nuclear device tests conducted at the Nevada Test Site (NTS). In these experiments neutrons from a device pass up a collimated line of site, and in the case of a Faraday cup (FC) NUEX, the neutrons pass through a thin CH 2 foil. Some of these neutrons interact with the nuclei in the foil, generating light charged particles (predominately protons) which are collected in a Faraday cup. The time dependence of the Faraday cup current is a measure of the energy spectrum of the neutrons that leak from the device. With good device models and accurate neutron-transport codes, the leakage spectrum can be converted into a prompt fast-neutron-induced fission-neutron energy spectrum (PFNS) from ~1 to 11 MeV. This has been done for two of our events containing a plutonium primary, where the NUEX data were of a particularly high quality, and one event containing a uranium primary. The fission-neutrons in the device were produced by fission events induced by neutrons over a broad range of energies. We have listed the inferred 1.5 MeV n + 239 Pu fission-neutron spectra in Tables 1 to 4 for outgoing neutron energies from 1.5 to ~10.5 MeV, in 1-MeV steps. The uranium device contained a larger high explosive charge. This limited the extraction of the uranium PFNS spectrum to upper neutron energy 9.5 MeV. The listed values represent the fission-neutron emission probability at the quoted outgoing neutron energies and are not the integrals over 1-MeV wide bins. The quoted relative emission probabilities are all relative to the probability of emitting 1.5 MeV neutrons. The presence of the high explosive charge surrounding the fissile material made estimates of the lower energy PFNS (below 1 MeV) problematic. To obtain estimates of the absolute emission probabilities, the low-energy portion of the PFNS was assumed to be as calculated by the Los Alamos (fission) model (LAM). The three NUEX inferred PFNS are labeled Pu-NUEX-1; Pu-NUEX-2; and U-NUEX-1. Pu-NUEX-1 was from an event near the end of US nuclear testing and its data quality was higher than the data associated with the earlier events used to obtain Pu-NUEX-2 and U-NUEX-1.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER 153: Measure the Fission Neutron Spectrum Shape Using Threshold Activation Detectors - CEDT Phase-1 Preliminary Design

The critical assembly chosen to perform these irradiation experiments is the Planet assembly. The purpose of this experiment is to determine more precisely the fission neutron spectrum. According to recent measurements of neutron cross section data performed in Russia, Hungary, and some other countries, the data suggest that ENDF/B fission neutron spectra has too few neutrons emitted below 1 MeV. In addition, measurements at TA-18 Los Alamos Critical Experiment Facility (LACEF) suggest that the fission spectrum may be too low (between 10-30%) for energies above 10 MeV. These proposed deficiencies in the tails of the fission spectrum may have repercussions in our mission applications related to nuclear energy and global security and need to be resolved. To measure the fission neutron spectrum, threshold activation foils will be used in the center of a highly enriched uranium assembly that will be assembled on the Planet vertical assembly machine.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗