Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectral control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A Common Calibration Source Framework for Fully-Polarimetric and Interferometric Radiometers

Two types of microwave radiometry--synthetic thinned array radiometry (STAR) and fully-polarimetric (FP) radiometry--have received increasing attention during the last several years. STAR radiometers offer a technological solution to achieving high spatial resolution imaging from orbit without requiring a filled aperture or a moving antenna, and FP radiometers measure extra polarization state information upon which entirely new or more robust geophysical retrieval algorithms can be based. Radiometer configurations used for both STAR and FP instruments share one fundamental feature that distinguishes them from more 'standard' radiometers, namely, they measure correlations between pairs of microwave signals. The calibration requirements for correlation radiometers are broader than those for standard radiometers. Quantities of interest include total powers, complex correlation coefficients, various offsets, and possible nonlinearities. A candidate for an ideal calibration source would be one that injects test signals with precisely controllable correlation coefficients and absolute powers simultaneously into a pair of receivers, permitting all of these calibration quantities to be measured. The complex nature of correlation radiometer calibration, coupled with certain inherent similarities between STAR and FP instruments, suggests significant leverage in addressing both problems together. Recognizing this, a project was recently begun at NASA Goddard Space Flight Center to develop a compact low-power subsystem for spaceflight STAR or FP receiver calibration. We present a common theoretical framework for the design of signals for a controlled correlation calibration source. A statistical model is described, along with temporal and spectral constraints on such signals. Finally, a method for realizing these signals is demonstrated using a Matlab-based implementation.

Kim, Edward J.↗

Depth Cue Integration in an Active Control Paradigm

Numerous models of depth cue integration have been proposed. Of particular interest is how the visual system processes discrepent cues, as might arise when viewing synthetic displays. A powerful paradigm for examining this integration process can be adapted from manual control research. This methodology introduces independent disturbances in the candidate cues, then performs spectral analysis of subjects' resulting motoric responses (e.g., depth matching). We will describe this technique and present initial findings.

Kaiser, Mary K.↗

Spectral (Finite) Volume Method for One Dimensional Euler Equations

Consider a mesh of unstructured triangular cells. Each cell is called a Spectral Volume (SV), denoted by Si, which is further partitioned into subcells named Control Volumes (CVs), indicated by C(sub i,j). To represent the solution as a polynomial of degree m in two dimensions (2D) we need N = (m+1)(m+2)/2 pieces of independent information, or degrees of freedom (DOFs). The DOFs in a SV method are the volume-averaged mean variables at the N CVs. For example, to build a quadratic reconstruction in 2D, we need at least (2+1)(3+1)/2 = 6 DOFs. There are numerous ways of partitioning a SV, and not every partition is admissible in the sense that the partition may not be capable of producing a degree m polynomial. Once N mean solutions in the CVs of a SV are given, a unique polynomial reconstruction can be obtained.

Wang, Z. J.↗

Active Control of F/A-18 Vertical Tail Buffeting using Piezoelectric Actuators

Vertical tail buffeting is a serious multidisciplinary problem that limits the performance of twin-tail fighter aircraft. The buffet problem occurs at high angles of attack when the vortical flow breaks down ahead of the vertical tails resulting in unsteady and unbalanced pressure loads on the vertical tails. This paper describes a multidisciplinary computational investigation for buffet load alleviation of full F/A-18 aircraft using distributed piezoelectric actuators. The inboard and outboard surfaces of the vertical tail are equipped with piezoelectric actuators to control the buffet responses in the first bending and torsion modes. The electrodynamics of the smart structure are expressed with a three-dimensional finite element model. A single-input-single-output controller is designed to drive the active piezoelectric actuators. High-fidelity multidisciplinary analysis modules for the fluid dynamics, structure dynamics, electrodynamics of the piezoelectric actuators, fluid-structure interfacing, and grid motion are integrated into a multidisciplinary computing environment that controls the temporal synchronization of the analysis modules. Peak values of the power spectral density of tail tip acceleration are reduced by as much as 22% in the first bending mode and by as much as 82% in the first torsion mode. RMS values of tip acceleration are reduced by as much as 12%.

Sheta, Essam F.↗

Animal model of neuropathic tachycardia syndrome

Clinically relevant autonomic dysfunction can result from either complete or partial loss of sympathetic outflow to effector organs. Reported animal models of autonomic neuropathy have aimed to achieve complete lesions of sympathetic nerves, but incomplete lesions might be more relevant to certain clinical entities. We hypothesized that loss of sympathetic innervation would result in a predicted decrease in arterial pressure and a compensatory increase in heart rate. Increased heart rate due to loss of sympathetic innervation is seemingly paradoxical, but it provides a mechanistic explanation for clinical autonomic syndromes such as neuropathic postural tachycardia syndrome. Partially dysautonomic animals were generated by selectively lesioning postganglionic sympathetic neurons with 150 mg/kg 6-hydroxydopamine hydrobromide in male Sprague-Dawley rats. Blood pressure and heart rate were monitored using radiotelemetry. Systolic blood pressure decreased within hours postlesion (Delta>20 mm Hg). Within 4 days postlesion, heart rate rose and remained elevated above control levels. The severity of the lesion was determined functionally and pharmacologically by spectral analysis and responsiveness to tyramine. Low-frequency spectral power of systolic blood pressure was reduced postlesion and correlated with the diminished tyramine responsiveness (r=0.9572, P=0.0053). The tachycardia was abolished by treatment with the beta-antagonist propranolol, demonstrating that it was mediated by catecholamines acting on cardiac beta-receptors. Partial lesions of the autonomic nervous system have been hypothesized to underlie many disorders, including neuropathic postural tachycardia syndrome. This animal model may help us better understand the pathophysiology of autonomic dysfunction and lead to development of therapeutic interventions.

NASA Discipline Regulatory Physiology↗

Early Oscillation Detection for Hybrid DC/DC Converter Fault Diagnosis

This paper describes a novel fault detection technique for hybrid DC/DC converter oscillation diagnosis. The technique is based on principles of feedback control loop oscillation and RF signal modulations, and Is realized by using signal spectral analysis. Real-circuit simulation and analytical study reveal critical factors of the oscillation and indicate significant correlations between the spectral analysis method and the gain/phase margin method. A stability diagnosis index (SDI) is developed as a quantitative measure to accurately assign a degree of stability to the DC/DC converter. This technique Is capable of detecting oscillation at an early stage without interfering with DC/DC converter's normal operation and without limitations of probing to the converter.

Wang, Bright L.↗

Optimizing Retrieval Spaces of Bio-Optical Models for Remote Sensing of Ocean Color

We investigated the optimal number of independent parameters required to accurately represent spectral remote sensing reflectances (𝑅 rs ) by performing principal component analysis on quality controlled in situ and synthetic 𝑅 rs data. We found that retrieval algorithms should be able to retrieve no more than four free parameters from 𝑅 rs spectra for most ocean waters. In addition, we evaluated the performance of five different bio-optical models with different numbers of free parameters for the direct inversion of in-water inherent optical properties (IOPs) from in situ and synthetic 𝑅 rs data. The multi-parameter models showed similar performances regardless of the number of parameters. Considering the computational cost associated with larger parameter spaces, we recommend bio-optical models with three free parameters for the use of IOP or joint retrieval algorithms.

Ocean Color↗

Enhanced extreme ultraviolet high-harmonic generation from chromium-doped magnesium oxide

High-order harmonic generation (HHG) from crystals is emerging as a new ultrashort source of coherent extreme ultraviolet (XUV) light. Doping the crystal structure can offer a new way to control the source properties. Here, we present a study of HHG enhancement in the XUV spectral region from an ionic crystal, using dopant-induced vacancy defects, driven by a laser centered at a wavelength of 1.55 μm. Our numerical simulations based on solutions of the semiconductor Bloch equations and density-functional theory are supported by our experimental observations and demonstrate an increase in the XUV high harmonic yield from doped bulk magnesium oxide (MgO) compared to undoped MgO, even at a low defect concentration. The anisotropy of the harmonic emission as a function of the laser polarization shows that the pristine crystal's symmetry is preserved. Our study paves the way toward the control of HHG in solids with complex defects caused by transition-metal doping.

36 MATERIALS SCIENCE↗

Multi-Wavelength, Multi-Beam, and Polarization-Sensitive Laser Transmitter for Surface Mapping

A multi-beam, multi-color, polarized laser transmitter has been developed for mapping applications. It uses commercial off-the-shelf components for a lowcost approach for a ruggedized laser suitable for field deployment. The laser transmitter design is capable of delivering dual wavelengths, multiple beams on each wavelength with equal (or variable) intensities per beam, and a welldefined state of polarization. This laser transmitter has been flown on several airborne campaigns for the Slope Imaging Multi-Polarization Photon Counting Lidar (SIMPL) instrument, and at the time of this reporting is at a technology readiness level of between 5 and 6. The laser is a 1,064-nm microchip high-repetition-rate laser emitting energy of about 8 microjoules per pulse. The beam was frequency-doubled to 532 nm using a KTP (KTiOPO4) nonlinear crystal [other nonlinear crystals such as LBO (LiB3O5) or periodically poled lithium niobiate can be used as well, depending on the conversion efficiency requirements], and the conversion efficiency was approximately 30 percent. The KTP was under temperature control using a thermoelectric cooler and a feedback monitoring thermistor. The dual-wavelength beams were then spectrally separated and each color went through its own optical path, which consisted of a beam-shaping lens, quarterwave plate (QWP), and a birefringent crystal (in this case, a calcite crystal, but others such as vanadate can be used). The QWP and calcite crystal set was used to convert the laser beams from a linearly polarized state to circularly polarized light, which when injected into a calcite crystal, will spatially separate the circularly polarized light into the two linear polarized components. The spatial separation of the two linearly polarized components is determined by the length of the crystal. A second set of QWP and calcite then further separated the two beams into four. Additional sets of QWP and calcite can be used to further split the beams into multiple orders of two. The spatially separated beams had alternating linearly polarization states; a half-wave plate (HWP) array was then made to rotate the alternating states of A multi-beam, multi-color, polarized laser transmitter has been developed for mapping applications. It uses commercial off-the-shelf components for a lowcost approach for a ruggedized laser suitable for field deployment. The laser transmitter design is capable of delivering dual wavelengths, multiple beams on each wavelength with equal (or variable) intensities per beam, and a welldefined state of polarization. This laser transmitter has been flown on several airborne campaigns for the Slope Imaging Multi-Polarization Photon Counting Lidar (SIMPL) instrument, and at the time of this reporting is at a technology readiness level of between 5 and 6. The laser is a 1,064-nm microchip high-repetition-rate laser emitting energy of about 8 microjoules per pulse. The beam was frequency-doubled to 532 nm using a KTP (KTiOPO4) nonlinear crystal [other nonlinear crystals such as LBO (LiB3O5) or periodically poled lithium niobiate can be used as well, depending on the conversion efficiency requirements], and the conversion efficiency was approximately 30 percent. The KTP was under temperature control using a thermoelectric cooler and a feedback monitoring thermistor. The dual-wavelength beams were then spectrally separated and each color went through its own optical path, which consisted of a beam-shaping lens, quarterwave plate (QWP), and a birefringent crystal (in this case, a calcite crystal, but others such as vanadate can be used). The QWP and calcite crystal set was used to convert the laser beams from a linearly polarized state to circularly polarized light, which when injected into a calcite crystal, will spatially separate the circularly polarized light into the two linear polarized components. The spatial separation of the two linearly polarized components is determined by the length of the crystal. A cond set of QWP and calcite then further separated the two beams into four. Additional sets of QWP and calcite can be used to further split the beams into multiple orders of two. The spatially separated beams had alternating linearly polarization states; a half-wave plate (HWP) array was then made to rotate the alternating states of

Yu, Anthony W.↗

Coherent control and high-fidelity readout of chromium ions in commercial silicon carbide

Abstract Transition metal ions provide a rich set of optically active defect spins in wide bandgap semiconductors. Chromium (Cr 4+ ) in silicon-carbide (SiC) produces a spin-1 ground state with a narrow, spectrally isolated, spin-selective, near-telecom optical interface. However, previous studies were hindered by material quality resulting in limited coherent control. In this work, we implant Cr into commercial 4H-SiC and show optimal defect activation after annealing above 1600 °C. We measure an ensemble optical hole linewidth of 31 MHz, an order of magnitude improvement compared to as-grown samples. An in-depth exploration of optical and spin dynamics reveals efficient spin polarization, coherent control, and readout with high fidelity (79%). We report T 1 times greater than 1 s at cryogenic temperatures (15 K) with a T 2 * = 317 ns and a T 2 = 81 μs, where spin dephasing times are currently limited by spin–spin interactions within the defect ensemble. Our results demonstrate the potential of Cr 4+ in SiC as an extrinsic, optically active spin qubit.

74 ATOMIC AND MOLECULAR PHYSICS↗

Theoretical design of acoustic treatment for cabin noise control of a light aircraft

An analytical procedure has been used to design an acoustic treatment for cabin noise control of a light aircraft. Using this approach acoustic add-on treatments capable of reducing the average noise levels in the cabin by about 17 dB from the untreated condition are developed. The added weight of the noise control package is about 2 percent of the total gross take-off weight of the aircraft. The analytical model uses modal solutions wherein the structural modes of the sidewall and the acoustic modes of the receiving space are accounted for. The additional noise losses due to add-on treatments are calculated by the impedance transfer method. The input noise spectral levels are selected utilizing experimental flight data. The add-on treatments considered for cabin noise control include aluminum honeycomb panels, constrained layer damping tape, porous acoustic materials, noise barriers and limp trim panels. To reduce the noise transmitted through the double wall aircraft windows to acceptable levels, changes in the design of the aircraft window are recommended.

Vaicaitis, R.↗

Effects of high energy simulated space radiation on polymeric second-surface mirrors

A radiation effects experimental program was performed, in which second surface mirror type thermal control coatings were exposed to ultraviolet radiation, electrons, and protons simultaneously. Stability was assessed by making periodic spectral reflectance measurements in situ (and in air after testing for comparison). Solar absorption coefficients were derived by computer. Many of the exposed materials showed large amounts of degradation in reflectance absorptance, principally due to the electron exposure. A series of tests was conducted, leading to the identification of a modified second surface mirror that shows considerable improvement and promise for stability during thermal control applications in a charged particle space radiation environment.

Eogdall, L. B.↗

WFIRST Integral Field Spectrograph Design and Operations Concept

One important aspect of the WFIRST coronagraphic instrument (CGI) technology demonstration is its ability to take high contrast spectra with an integral field spectrograph (IFS). Future missions such as LUVOIR and HabEx rely on IFS technologies for the spectral characterization of any objects they discover; spectral characterization is the core science of their exoplanet imaging instruments. The CGI IFS, being designed and built and Goddard Space Flight Center, has a spectral resolution of R50 and is designed to accommodate a 20% bandpass spanning 600-970nm. The bands and spectral resolution were chosen by the science investigation teams to target key methane absorption features, with the aim of constraining abundances. For CGI as a technology demonstration, these are the minimum set of defining features to demonstrate on-orbit wavefront control with an IFS capable of producing science. The ability to close a wavefront control loop around an IFS, maintain a stable dark hole, and provide time resolved data that simultaneously spans spatial and spectral dimensions are crucial demonstrations for future observatories. We highlight the IFS requirements and how the on-orbit calibration is handled. We also provide further detail on the optomechanical design, its stability based on thermal and structural predictions, anticipated performance, and operations concept of the CGI IFS.

Groff, Tyler↗

Ambient Light Intensity, Actigraphy, Sleep and Respiration, Circadian Temperature and Melatonin Rhythms and Daytime Performance of Crew Members During Space Flight on STS-90 and STS-95 Missions

Sleep disruption and associated waking sleepiness and fatigue are common during space flight. A survey of 58 crew members from nine space shuttle missions revealed that most suffered from sleep disruption, and reportedly slept an average of only 6.1 hours per day of flight as compared to an average of 7.9 hours per day on the ground. Nineteen percent of crewmembers on single shift missions and 50 percent of the crewmembers in dual shift operations reported sleeping pill usage (benzodiazepines) during their missions. Benzodiazepines are effective as hypnotics, however, not without adverse side effects including carryover sedation and performance impairment, anterograde amnesia, and alterations in sleep EEG. Our preliminary ground-based data suggest that pre-sleep administration of 0.3 mg of the pineal hormone melatonin may have the acute hypnotic properties needed for treating the sleep disruption of space flight without producing the adverse side effects associated with benzodiazepines. We hypothesize that pre-sleep administration of melatonin will result in decreased sleep latency, reduced nocturnal sleep disruption, improved sleep efficiency, and enhanced next-day alertness and cognitive performance both in ground-based simulations and during the space shuttle missions. Specifically, we have carried out experiments in which: (1) ambient light intensity aboard the space shuttle is assessed during flight; (2) the impact of space flight on sleep (assessed polysomnographically and actigraphically), respiration during sleep, circadian temperature and melatonin rhythms, waking neurobehavioral alertness and performance is assessed in crew members of the Neurolab and STS-95 missions; (3) the effectiveness of melatonin as a hypnotic is assessed independently of its effects on the phase of the endogenous circadian pacemaker in ground-based studies, using a powerful experimental model of the dyssomnia of space flight; (4) the effectiveness of melatonin as a hypnotic is assessed during the STS-90 (Neurolab) and STS-95 missions in a double-blind placebo-controlled trial. In both flight-based experiments, the effects of melatonin on sleep stages and spectral composition of the EEG during sleep will be determined as well as its effects on daytime alertness and performance; (5) the impact of space flight on sleep and waking neurobehavioral alertness and performance in 30-45-year-old astronauts is compared with its impact in a 77-year-old astronaut. This case study is the first to assess the effects of space flight on an older individual. Because the investigators are still blind to the treatment in this double-blind, placebo-controlled trial, preliminary results will be presented independent of the drug condition.

Czeisler, Charles A.↗

Electrically Reconfigurable Liquid Metal Nanophotonic Platform for Color Display and Imaging

Dynamically tunable optical materials and device architectures are essential for future photonic technologies, yet conventional solid metals lack the intrinsic tunability required for advanced functionalities. Gallium-based liquid metals (LMs) present an appealing alternative thanks to their distinctive mechanical and optical properties; however, their practical integration in tunable photonic elements remains largely unexplored. Here, in this study, an electrochemically controlled nanophotonic platform is demonstrated that integrates a dynamically reconfigurable LM ground plane with gold nanoantenna arrays within a microfluidic system, enabling precise and reversible modulation of optical resonances across the visible to mid-infrared spectral ranges. By employing moderate operational voltages (1.5–3.0 V), real-time tuning of high-resolution structural color patterns is achieved through nanoscale control of the interfacial gap between the LM and Au nanoantennas. This innovative platform facilitates electrically programmable, high-contrast color patterns suitable for dynamic optical displays, secure anti-counterfeiting labels, and imaging applications. Additionally, this platform enables tunable mid-infrared spectral responses, which may be utilized for chemical and biological sensing applications. This versatile integrated LM-based nanophotonic platform opens new paths toward multifunctional, actively tunable/reconfigurable photonic device and system technologies.

Imaging↗

Postural tachycardia syndrome: time frequency mapping

Orthostatic tachycardia is common but its specificity remains uncertain. Our preliminary work suggested that using autonomic function testing in conjunction with time-frequency mapping (TFM), it might be possible to characterize a subset of the postural tachycardia syndrome (POTS), that is due to a restricted autonomic neuropathy. We describe 20 patients (17 women and 3 men, aged 14-43 years) with florid POTS and 20 controls (14 women and 6 men, aged 20-41 years). Autonomic failure was quantified by its distribution (cardiovagal, adrenergic and sudomotor) and severity, a symptom profile was generated, and spectral indices, based on modified Wigner distribution during rest and head-up tilt (80 degrees) were evaluated. During tilt-up POTS patients differed from controls by an excessive heart rate (> 130 bpm) (P < 0.001), and higher diastolic pressure (P < 0.01). During rest, cardiovagal oscillations (at respiratory frequencies [RF]) and slow rhythms at nonrespiratory frequencies (NONRF) (from 0.01 to 0.07 Hz) in R-R intervals (RRI) (P < 0.01) were reduced. Both RF and NONRF rhythms in RRI were further blunted with tilt-up (P < 0.001). Slow adrenergic vasomotor rhythms in blood pressure (BP) (approximately 0.07 Hz) surged with tilt-up and returned to normal levels afterwards. The index of sympatho-vagal balance (NONRF-Systolic BP (SBP)/RF-RRI) was dramatically increased in POTS (P < 0.001). Distal postganglionic sudomotor failure was observed, and impairment of the BP responses to the Valsalva maneuver (phase II) suggested peripheral adrenergic dysfunction. Persistent orthostatic dizziness, tiredness, gastrointestinal symptoms and palpitations were common in POTS patients. It is possible to identify a subset of POTS patients who have a length-dependent autonomic neuropathy, affecting the peripheral adrenergic and cardiovagal fibers, with relative preservation of cardiac adrenergic fibers.

NASA Discipline Number 14-10↗

Guidance, Navigation, and Control Performance for the GOES-R Spacecraft

The Geostationary Operational Environmental Satellite-R Series (GOES-R) is the first of the next generation geostationary weather satellites. The series represents a dramatic increase in Earth observation capabilities, with 4 times the resolution, 5 times the observation rate, and 3 times the number of spectral bands. GOES-R also provides unprecedented availability, with less than 120 minutes per year of lost observation time. This paper presents the Guidance Navigation & Control (GN&C) requirements necessary to realize the ambitious pointing, knowledge, and Image Navigation and Registration (INR) objectives of GOES-R. Because the suite of instruments is sensitive to disturbances over a broad spectral range, a high fidelity simulation of the vehicle has been created with modal content over 500 Hz to assess the pointing stability requirements. Simulation results are presented showing acceleration, shock response spectra (SRS), and line of sight (LOS) responses for various disturbances from 0 Hz to 512 Hz. Simulation results demonstrate excellent performance relative to the pointing and pointing stability requirements, with LOS jitter for the isolated instrument platform of approximately 1 micro-rad. Attitude and attitude rate knowledge are provided directly to the instrument with an accuracy defined by the Integrated Rate Error (IRE) requirements. The data are used internally for motion compensation. The final piece of the INR performance is orbit knowledge, which GOES-R achieves with GPS navigation. Performance results are shown demonstrating compliance with the 50 to 75 m orbit position accuracy requirements. As presented in this paper, the GN&C performance supports the challenging mission objectives of GOES-R.

Control↗

An airborne system for collecting polarization imagery

This paper describes a recently completed electrooptical camera flying onboard the NASA ER-2 high altitude aircraft. The device includes a six-position filter wheel which can be fitted with a combination of polarizing and/or spectral filters. An alternate configuration will include a polarizing filter which can be rotated to any angle under computer control. The camera mount in the nose of the ER-2 can tilt forward or aft up to 40 degrees, both for bidirectional reflectance studies and for image motion compensation (the aircraft moves 34 meters between frame acquisitions). The ground resolution is nominally 5 meters from and altitude of 20 km. Spectral responsivity is that of the silicon imaging array (Kodak KAF-1400). Initial data sets were acquired in support of the International Satellite Cloud Climatology Program Regional Experiment of November, 1991, and will be used to study cirrus cloud properties.

Hildum, Edward A.↗