Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sim”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Novel principal component analysis tool based on python for analysis of complex spectra of time-of-flight secondary ion mass spectrometry

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful surface analysis tool, which can simultaneously provide elemental, isotopic, and molecular information with part per million (ppm) sensitivity. However, each spectrum may be composed of hundreds of ion signals, which makes the spectra data complex. Principal component analysis (PCA) is a multivariate analysis technique that has been widely used to figure out the variances among samples in ToF-SIMS spectra data analysis and is showing great success in the explanation of complex ToF-SIMS spectra. So far, several software tools have been developed for PCA of ToF-SIMS spectra; however, none of them are freely available. Such a situation leads to some difficulties in extending applications of PCA to various research fields. More importantly, it has long been challenging for common researchers to understand PCA plots and extract chemical differences among samples. In this work, we developed a new and flexible software tool (named “advanced spectra pca toolbox”) based on python for PCA of complex ToF-SIMS spectra along with an easy-to-read manual. It can generate data analysis reports automatically to explain chemical differences among samples, allowing less experienced researchers to easily understand tricky PCA results. Moreover, it is expandable and compatible with artificial intelligence/machine learning functions. Pure goethite and different lignin adsorbed goethite samples were used as a model system to demonstrate our new software tool, proving that our software tool can be readily used in complex spectra data processing. Our new software tool is open-source, convenient, flexible, and expandable. We expect this open-source tool will benefit the ToF-SIMS community.

47 OTHER INSTRUMENTATION↗

Search for new phenomena using the invariant mass distribution of same-flavour opposite-sign dilepton pairs in events with missing transverse momentum in $\sqrt{s}=13$ TeV pp collisions with the ATLAS detector

A search for new phenomena in final states containing an e + e - or μ + μ - pair, jets, and large missing transverse momentum is presented. This analysis makes use of proton–proton collision data with an integrated luminosity of 36.1 fb -1 , collected during 2015 and 2016 at a centre-of-mass energy s√=13 TeV with the ATLAS detector at the Large Hadron Collider. The search targets the pair production of supersymmetric coloured particles (squarks or gluinos) and their decays into final states containing an e + e - or μ + μ - pair and the lightest neutralino ($\sim\atop{χ}$ $0\atop{1}$) via one of two next-to-lightest neutralino ($\sim\atop{χ}$ $0\atop{2}$) decay mechanisms: $\sim\atop{χ}$ $0\atop{2}$→Z$\sim\atop{χ}$ $0\atop{1}$, where the Z boson decays leptonically leading to a peak in the dilepton invariant mass distribution around the Z boson mass; and $\sim\atop{χ}$ $0\atop{2}$→ℓ + ℓ - $\sim\atop{χ}$ $0\atop{1}$ with no intermediate ℓ + ℓ - resonance, yielding a kinematic endpoint in the dilepton invariant mass spectrum. The data are found to be consistent with the Standard Model expectation. Finally, results are interpreted using simplified models, and exclude gluinos and squarks with masses as large as 1.85 and 1.3 TeV at 95% confidence level, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k $\times$ 1k, 15 $\mu$m pixel, fully-depleted, $p$-channel devices that have been thinned to $\sim$250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., a single-sample readout noise $< 4.3$\,e$^-$\,rms/pixel, the ability to achieve multi-sample readout noise $\ll 1\,$e$^-$\,rms/pix, full-well capacities $\sim$40,000--65,000 e$^-$, low dark current and charge transfer inefficiency ($\sim 2$ $\times$ $10^{-4}$ e$^-$/pixel/s and 3.44 $\times$ $10^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim 80\%$ between 450\,nm and 980\,nm ($\gtrsim 90\%$ between 600\,nm and 900\,nm). We optimize the readout sequence timing to achieve sub-electron noise ($\sim 0.5$\,e$^-$\,rms/pix) and photon-counting ($\sim 0.22$\,e$^-$\,rms/pix) readout noise over an area of 2k $\times$ 4k and 110 $\times$ 4k pixels, respectively in a readout time of $\lesssim 17$min. We observed two Lyman-$\alpha$ emitting quasars (HB89\,1159$+$123 and QSO\,J1621$–$0042) at redshift $z \sim 3.5$, two moderate redshift galaxy clusters (CL\,J1001$+$0220 and SPT-CL\,J2040$-$4451), an emission line galaxy at $z = 0.3239$, a candidate member star of the Bo\"{o}tes~II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observation of the quasar HB89\,1159$+$123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvement for SIFS for observations in the low-background, readout-noise-dominated regime. We outline preliminary scientific studies that will leverage the SIFS-Skipper CCD data to derive new cosmological measurements in the context of dark matter and galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

A Very Large (θ{sub E} ≳ 40″) Strong Gravitational Lens Selected with the Sunyaev–Zel’dovich Effect: PLCK G287.0+32.9 (z = 0.38)

Since galaxy clusters sit at the high end of the mass function, the number of galaxy clusters both massive and concentrated enough to yield particularly large Einstein radii poses useful constraints on cosmological and structure formation models. To date, less than a handful of clusters are known to have Einstein radii exceeding ∼40{sup ′′} (for a source at z{sub s}≃2, nominally). Here, we report an addition to that list of the Sunyaev–Zel’dovich (SZ) selected cluster, PLCK G287.0+32.9 (z = 0.38), the second-highest SZ-mass (M {sub 500}) cluster from the Planck catalog. We present the first strong-lensing analysis of the cluster, identifying 20 sets of multiply imaged galaxies and candidates in new Hubble Space Telescope (HST) data, including a long, l∼22{sup ′′} giant arc, as well as a quadruply imaged, apparently bright (magnified to J{sub F110W}=25.3 AB), likely high-redshift dropout galaxy at z{sub phot}=6.90 [6.13–8.43] (95% C.I.). Our analysis reveals a very large critical area (1.55 arcmin{sup 2}, z{sub s}≃2), corresponding to an effective Einstein radius of θ{sub E}∼42{sup ′′}. The model suggests the critical area will expand to 2.58 arcmin{sup 2} (θ{sub E}∼54{sup ′′}) for sources at z{sub s}∼10. Our work adds to recent efforts to model very massive clusters toward the launch of the James Webb Space Telescope, in order to identify the most useful cosmic lenses for studying the early universe. Spectroscopic redshifts for the multiply imaged galaxies and additional HST data will be necessary for refining the lens model and verifying the nature of the z∼7 dropout.

79 ASTRONOMY AND ASTROPHYSICS↗

The Shuttle imaging microwave system experiment

The purpose of the Shuttle microwave system experiment (SIMS) is to utilize the capabilities of the Space Shuttle to perform passive microwave measurements of thermal emission from the earth's atmosphere and surface, which can be interpreted in terms of meaningful atmospheric and geophysical parameters. The paper is a status report of an ongoing definition phase study of SIMS. The wavelengths and observable parameters for the SIMS channels are identified. The SIMS instrument is discussed with particular reference to the antenna system. A system consisting of a parabolic torus reflector offset fed by a number of feeds and radiometers on a rotating wheel is determined to be the best antenna configuration for SIMS. A tentative data flow diagram for SIMS is also provided.

Waters, J. W.↗

Observations of the Jovian System with the Chandra X-Ray Observatory

The {\sl Chandra X-ray Observatory) observed the Jovian system on 25-26 Nov 1999 with the Advanced CCD Imaging Spectrometer (ACIS), in support of the Galileo flyby of Io, and on 18 Dec 2000 with the imaging array of the High Resolution Camera (HRC-I), in support of the Cassini flyby of Jupiter. These sensitive, very high spatial-resolution X-ray observations have revealed that Jupiter's northern x-ray aurora originates at a spot fixed in a coordinate system rotating with the planet at latitude (60--70 deg north) and longitude (160--180 deg System III). Contrary to previous expectations, this location is poleward of the main FUV auroral oval and the foot of the Io Flux Tube, and is apparently connected magnetically to a region of the outer magnetosphere beyond $\sim$30 Jupiter radii. The northern auroral x-ray emission varies with a period $\sim$45 minute and has a an average power of $\sim$1 GW. The earlier view that Jupiter's x-ray aurora resulted from the precipitation of heavy ions from the outer edge of the lo Plasma Torus is now in doubt. Jupiter's disk also emits x-rays with a power of $\sim$2 GW, perhaps resulting from reprocessing of solar x-rays in its atmosphere. These observations reveal for the first time x-ray emission from the Io Plasma Torus, with a power of $\sim$0.1 Gw. The origin of this emission is not currently understood, although bremmstrahlung from non-thermal electrons may play a significant role. Finally, we report the discovery of very faint ($\sim$1--2 MW) soft x-ray emission from the Galilean satellites Io, Europa, and probably Ganymede, most likely as a result of bombardment of their surfaces by energetic ($ greater than $10 keV) H, O, and S ions from the region of the Io Plasma Torus.

Elsner, R. F.↗

Degradation of Victoria Crater, Mars

The $\sim$750 m diameter and $\sim$75 m deep Victoria crater in Meridiani Planum, Mars, presents evidence for significant degradation including a low, serrated, raised rim characterized by alternating alcoves and promontories, a surrounding low relief annulus, and a floor partially covered by dunes. The amount and processes of degradation responsible for the modified appearance of Victoria crater were evaluated using images obtained in situ by the Mars Exploration Rover Opportunity in concert with a digital elevation model created using orbital HiRISE images. Opportunity traversed along the north and northwest rim and annulus, but sufficiently characterized features visible in the DEM to enable detailed measurements of rim relief, ejecta thickness, and wall slopes around the entire degraded, primary impact structure. Victoria retains a 5 m raised rim consisting of 1-2 m of uplifted rocks overlain by 3 m of ejecta at the rim crest. The rim is $\sim$120 to 220 m wide and is surrounded by a dark annulus reaching an average of 590 m beyond the raised rim. Comparison between observed morphology and that expected for pristine craters 500 to 750 m across indicate the original, pristine crater was close to 600 m in diameter. Hence, the crater has been erosionally widened by approximately 150 m and infilled by about 50 m of sediments. Eolian processes are responsible for modification at Victoria, but lesser contributions from mass wasting or other processes cannot be ruled out. Erosion by prevailing winds is most significant along the exposed rim and upper walls and accounts for $\sim$50 m widening across a WNW-ESE diameter. The volume of material eroded from the crater walls and rim is $\sim$20% less than the volume of sediments partially filling the crater, indicating eolian infilling from sources outside the crater over time. The annulus formed when $\sim$1 m deflation of the ejecta created a lag of more resistant hematite spherules that trapped darker, regional basaltic sands.

Wilson, Sharon A.↗

Stroboscopic Image Modulation to Reduce the Visual Blur of an Object Being Viewed by an Observer Experiencing Vibration

A method and apparatus for reducing the visual blur of an object being viewed by an observer experiencing vibration. In various embodiments of the present invention, the visual blur is reduced through stroboscopic image modulation (SIM). A SIM device is operated in an alternating "on/off" temporal pattern according to a SIM drive signal (SDS) derived from the vibration being experienced by the observer. A SIM device (controlled by a SIM control system) operates according to the SDS serves to reduce visual blur by "freezing" (or reducing an image's motion to a slow drift) the visual image of the viewed object. In various embodiments, the SIM device is selected from the group consisting of illuminator(s), shutter(s), display control system(s), and combinations of the foregoing (including the use of multiple illuminators, shutters, and display control systems).

Kaiser, Mary K.↗

Developing a soil inversion model framework for regional permafrost monitoring

Currently, the community lacks capabilities to assess and monitor landscape scale permafrost active layer dynamics over large extents. To address this need, we developed a concept of a remote sensing based Soil Inversion Model for regional Permafrost (SIM-P) monitoring. The current SIM-P framework includes a satellite-based soil process model and a soil dielectric model. We are also working on incorporating a radar scattering model for Arctic tundra into the SIM-P framework. A unified soil parameterization scheme was developed to harmonize key soil thermal, hydraulic and dielectric parameters in the soil process and radar models that can be used in the joint soil-radar inversion framework. The soil parameter retrievals of the SIM-P framework include soil organic content (SOC) and active layer thickness (ALT). Initial tests of SIM-P using in-situ soil permittivity observations showed reasonable accuracy in predicting site-level SOC and soil temperature profiles at an Alaska tundra site and ALT in Arctic Alaska. SIM-P will be further tested using airborne P- and L-band radar data collected during NASA’s Arctic Boreal Vulnerability Experiment (ABoVE) to evaluate the sensitivity of longwave radar to active layer properties.

Miller, Charles E.↗

Testing and Expertise for Marine Energy (TEAMER) Program Support - Numerical Modeling Assistance for iProTech's "PIP" WEC Device: Cooperative Research and Development Final Report, CRADA Number CRD-20-17303

Develop a time-domain, 3 degree of freedom numerical model of IProTech's PIP device, including power take-off (PTO), that can be used to develop control algorithms and establish a baseline technology performance level (TPL). This is important to IProTech because having a good numerical model allows IProTech to optimize design and control algorithms on an ongoing basis. A baseline TPL enables the PIP technology to be benchmarked against other wave energy converter (WEC) concepts, providing (i) justification (or not) for investment in wave tank model testing, (ii) identifying optimum design parameters and control algorithms for the test model, (iii) specifying test conditions and (iv) interpreting wave tank test results. An accredited WEC-Sim model of the PIP device is an essential tool for further development of the technology. 1) The development of numerical models of the PIP concept will enable iProTech to evaluate the potential performance of this concept, and to investigate how sensitive the device is to different variables within the system (e.g. hydraulic components, geometry dimensions, etc.) 2) The numerical models were developed with WEC-Sim and PTO-Sim -- the de-facto industry standard WEC numerical modeling tools. A detailed model of the system's hydraulic circuit was developed with PTO-Sim. However, WEC-Sim is based on linear hydrodynamics and has several limitations; validation against high fidelity models/physical scale models would help to build confidence in the results.

16 TIDAL AND WAVE POWER↗

Reducing the matrix effect in mass spectral imaging of biofilms using flow-cell culture

The interactions between soil microorganisms and soil minerals play a crucial role in the formation and evolution of minerals and the stability of soil aggregates. Due to the heterogeneity and diversity of the soil environment, the under-standing of the functions of bacterial biofilms in soil minerals at the microscale is limited. A soil mineral-bacterial biofilm system was used as a model in this study, and it was analyzed by time-of-flight secondary ion mass spectrometry (ToF-SIMS) to acquire molecular level information. Static culture in multi-wells and dynamic flow-cell culture in microfluidics of biofilms were investigated. Our results show that more characteristic molecules of biofilms can be observed in SIMS spectra of the flow-cell culture. In contrast, biofilm signature peaks are buried under the mineral components in SIMS spectra in the static culture case. Spectral overlay was used in peak selection prior to performing Principal component analysis (PCA). Comparisons of the PCA results between the static and flow-cell culture show more pronounced molecular features and higher loadings of organic peaks of the dynamic cultured specimens. For example, fatty acids secreted from bacterial biofilm extracellular polymeric substance are likely to be responsible for biofilm dispersal due to mineral treatment up to 48 h. Such findings suggest that the use of microfluidic cells to dynamically culture biofilms be a more suitable method for reducing the matrix effect arisen from the growth medium and minerals as a perturbation fac-tor for improved spectral and multivariate analysis of complex mass spectral data in ToF-SIMS. These results show that the interaction mechanism between biofilms and soil minerals at the molecular level can be better studied using the flow-cell culture and advanced mass spectral imaging techniques like ToF-SIMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular detection of per- and polyfluoroalkyl substances in water using time-of-flight secondary ion mass spectrometry

Detection of per- and polyfluoroalkyl substances (PFASs) is crucial in environmental mitigation and remediation of these persistent pollutants. We demonstrate that time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a viable technique to analyze and identify these substances at parts per trillion (ppt) level in real field samples without complicated sample preparation due to its superior surface sensitivity. Several representative PFAS compounds, such as perfluorooctanesulfonic acid (PFOS), perfluorobutanoic acid (PFBA), perfluoropentanoic acid (PFPeA), perfluoheptanoic acid (PFHpA), and perfluorononanoic acid (PFNA), and real-world groundwater samples collected from monitoring wells installed around at a municipal wastewater treatment plant located in Southern California were analyzed in this work. ToF-SIMS spectral comparison depicts sensitive identification of pseudo-molecular ions, characteristic of reference PFASs. Additionally, principal component analysis (PCA) shows clear discrimination among real samples and reference compounds. Our results show that characteristic molecular ion and fragments peaks can be used to identify PFASs. Furthermore, SIMS two-dimensional (2D) images directly exhibit the distribution of perfluorocarboxylic acid (PFCA) and PFOS in simulated mixtures and real wastewater samples. Such findings indicate that ToF-SIMS is useable to determine PFAS compounds in complex environmental water samples. In conclusion, ToF-SIMS provides simple sample preparation and high sensitivity in mass spectral imaging, offering an alternative solution for environmental forensic analysis of PFASs in wastewater in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.

59 BASIC BIOLOGICAL SCIENCES↗

Observational Model for Precision Astrometry with the Space Interferometry Mission

The Space Interferometry Mission (SIM) is a space-based 10-m baseline Michelson optical interferometer operating in the visible waveband that is designed to achieve astrometric accuracy in the single digits of the microarcsecond domain. Over a narrow field of view SIM is expected to achieve a mission accuracy of 1 microarcsecond. In this mode SIM will search for planetary companions to nearby stars by detecting the astrometric "wobble" relative to a nearby reference star. In its wide-angle mode, SIM will provide 4 microarcsecond precision absolute position measurements of stars, with parallaxes to comparable accuracy, at the end of its 5-year mission. The expected proper motion accuracy is around 3 microarcsecond/year, corresponding to a transverse velocity of 10 m/ s at a distance of 1 kpc. The basic astrometric observable of the SIM instrument is the pathlength delay. This measurement is made by a combination of internal metrology measurements that determine the distance the starlight travels through the two arms of the interferometer, and a measurement of the white light stellar fringe to find the point of equal pathlength. Because this operation requires a non-negligible integration time, the interferometer baseline vector is not stationary over this time period, as its absolute length and orientation are time varying. This paper addresses how the time varying baseline can be "regularized" so that it may act as a single baseline vector for multiple stars, as required for the solution of the astrometric equations.

TILE OBSERVATIONS↗

Measurement of the Non-common Vertex Error of a Double Corner Cube

The Space Interferometry Mission (SIM) requires the control of the optical path of each interferometer with picometer accuracy. Laser metrology gauges are used to measure the path lengths to the fiiducial corner cubes at the siderostats. Due to the geometry of SIM a single corner cube does not have sufficient acceptance angle to work with all the gauges. Therefore SIM employs a double corner cube. Current fabrication methods are in fact not capable of producing such a double corner cube with vertices having sufficient commonality. The plan for SIM is to measure the non-commonalty of the vertices and correct for the error in orbit. SIM requires that the non-common vertex error (NCVE) of the double corner cube to be less than 6 (mu)m. The required accuracy for the knowledge of the NCVE is less than 1 (mu)m. This paper explains a method of measuring non-common vertices of a brassboard double corner cube with sub-micron accuracy. The results of such a measurement will be presented.

Space Interferometry Mission (SIM)↗

Astrophysics with Microarcsecond Accuracy Astrometry

Space-based astrometry promises to provide a powerful new tool for astrophysics. At a precision level of a few microarcsonds, a wide range of phenomena are opened up for study. In this paper we discuss the capabilities of the SIM Lite mission, the first space-based long-baseline optical interferometer, which will deliver parallaxes to 4 microarcsec. A companion paper in this volume will cover the development and operation of this instrument. At the level that SIM Lite will reach, better than 1 microarcsec in a single measurement, planets as small as one Earth can be detected around many dozen of the nearest stars. Not only can planet masses be definitely measured, but also the full orbital parameters determined, allowing study of system stability in multiple planet systems. This capability to survey our nearby stellar neighbors for terrestrial planets will be a unique contribution to our understanding of the local universe. SIM Lite will be able to tackle a wide range of interesting problems in stellar and Galactic astrophysics. By tracing the motions of stars in dwarf spheroidal galaxies orbiting our Milky Way, SIM Lite will probe the shape of the galactic potential history of the formation of the galaxy, and the nature of dark matter. Because it is flexibly scheduled, the instrument can dwell on faint targets, maintaining its full accuracy on objects as faint as V=19. This paper is a brief survey of the diverse problems in modern astrophysics that SIM Lite will be able to address.

SIM Science Team↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

A case study on the use of carbon sticky tabs for microbeam uranium isotope measurement with an emphasis on understanding the influence of subtle variations in substrate composition

In this paper we integrate laser induced breakdown spectroscopy (LIBS), large geometry secondary ion mass spectrometry (LG-SIMS), laser ablation—multi collector—inductively coupled plasma—mass spectrometry (LA-MC-ICP-MS), and trace elemental compositions obtained by bulk digestion from a suite of commercially available carbon sticky tabs to determine if subtle variations in the tab’s composition can be tied to shifts in the observed uranium isotopic composition of the IRMM-2020 standard relative to its ‘true’ value. The results suggest that, although clear differences exist in the relative abundances of carbon and hydrogen across the various carbon sticky tabs examined, as well as differences in their trace elemental and total uranium concentrations, these differences do not appear to influence the LG-SIMS or LA-MC-ICP-MS uranium isotope ratio measurements, or the appearance of the uranium mass spectrum scans. Instead, the quality (i.e., precision and accuracy) of the LG-SIMS and LA-MC-ICP-MS results are directly proportional to the observed signal intensity at the time of analysis. For the LG-SIMS measurements, there does appear to be a direct correlation between 235U1H hydride formation rates and vacuum conditions within the instrument’s analytical chamber. Furthermore, none of the carbon sticky tabs examined by LG-SIMS displayed evidence of elevated background uranium content. While a preliminary correlation was observed between the uranium isotope background signal during LA-MC-ICP-MS and the total uranium concentrations determined by isotope dilution, none of the tabs displayed a high enough analytical background to affect the isotope ratio measurements.

Zirakparvar, Alex [ORNL] (ORCID:0000000337797730)↗