Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor fabrication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Open Circuit Resonant Sensors for Composite Damage Detection and Diagnosis

Under the Integrated Vehicle Health Management (IVHM) program work was begun to investigate the feasibility of sensor systems for detecting and diagnosing damage to aircraft composite structures and materials. Specific interest for this study was in damage initiated by environmental storm hazards and the direct effect of lightning strikes on the material structures of a composite aircraft in flight. A series of open circuit resonant sensors was designed, fabricated, characterized, and determined to be a potentially viable means for damage detection and diagnosis of composite materials. The results of this research and development effort are documented in this report.

Mielnik, John J., Jr.↗

Nanowire sensor, sensor array, and method for making the same

The present invention relates to a nanowire sensor and method for forming the same. More specifically, the nanowire sensor comprises at least one nanowire formed on a substrate, with a sensor receptor disposed on a surface of the nanowire, thereby forming a receptor-coated nanowire. The nanowire sensor can be arranged as a sensor sub-unit comprising a plurality of homogeneously receptor-coated nanowires. A plurality of sensor subunits can be formed to collectively comprise a nanowire sensor array. Each sensor subunit in the nanowire sensor array can be formed to sense a different stimulus, allowing a user to sense a plurality of stimuli. Additionally, each sensor subunit can be formed to sense the same stimuli through different aspects of the stimulus. The sensor array is fabricated through a variety of techniques, such as by creating nanopores on a substrate and electrodepositing nanowires within the nanopores.

Yun, Minhee↗

Proposed Triple-Wall, Voltage-Isolating Electrodes for Multiple-Bias-Voltage 3D Sensors

Dividing 3D active-edge silicon sensors into separate sections with a triple-wall sandwich of two trench electrodes separated by an insulating layer, will allow two or more bias voltages to be used simultaneously. Such sensors could be fabricated with only a single group of lowtemperature additional steps and may be necessary to prevent a new form of radiation-damage failure in non-uniform radiation fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced ceramic components with embedded sapphire optical fiber sensors for high temperature applications

Here this paper describes an extrusion-based additive manufacturing process that has been developed to enable embedment of sapphire optical fiber sensors in ceramic components during the part fabrication. In this process, an aqueous paste of ceramic particles is extruded through a moving nozzle to build the part layer-by-layer. In the case of sensor embedment, the fabrication process is halted after a certain number of layers have been deposited; the sensors are placed in their predetermined locations, and the remaining layers are deposited until the part fabrication is completed. Because the sensors are embedded during the fabrication process, they are fully integrated with the part and the problems of traditional sensor embedment can be eliminated. Scanning electron microscopy was used to observe the embedded sensors and to detect any possible flaws in the part or embedded sensor. Attenuation of the sensors was measured in near-infrared region (1500–1600 nm wavelength). Standard test methods were employed to examine the effect of embedded fibers on the strength and hardness of the parts. The results indicated that the sapphire fiber sensors with diameters smaller than 250 micrometers were able to endure the freeform extrusion fabrication process and the post-processing without compromising the part properties.

36 MATERIALS SCIENCE↗

Development of High Temperature/High Sensitivity Novel Chemical Resistive Sensor

The research has been focused to design, fabricate, and develop high temperature/high sensitivity novel multifunctional chemical sensors for the selective detection of fossil energy gases used in power and fuel systems. By systematically studying the physical properties of the LnBaCo 2 O 5+d (LBCO) [Ln=Pr or La] thin-films, a new concept chemical sensor based high temperature chemical resistant change has been developed for the application for the next generation highly efficient and near zero emission power generation technologies. We also discovered that the superfast chemical dynamic behavior and an ultrafast surface exchange kinetics in the highly epitaxial LBCO thin films. Furthermore, our research indicates that hydrogen can superfast diffuse in the ordered oxygen vacancy structures in the highly epitaxial LBCO thin films, which suggest that the LBCO thin film not only can be an excellent candidate for the fabrication of high temperature ultra sensitive chemical sensors and control systems for power and fuel monitoring systems, but also can be an excellent candidate for the low temperature solid oxide fuel cell anode and cathode materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Room temperature detection of NO{sub 2} using InSb nanowire

Room temperature detection of NO{sub 2} down to one part-per-million (ppm) using single crystalline n-type InSb nanowires (NWs) chemiresistive gas sensor is presented. These sensors were synthesized and fabricated by the combination of chemical vapor deposition and dielectrophoresis alignment techniques. The sensor devices showed an increase in resistance upon exposure to successive increments of NO{sub 2} concentration up to 10 ppm. The reduction in conductance of n-type InSb NWs when exposed to NO{sub 2} is made possible due to the charge transfer from the InSb NW surface to the adsorbed electron acceptor NO{sub 2} molecules. The demonstrated results suggest InSb NW as a promising candidate in sensing applications as well as being environmental friendly over existing arsenic and/or phosphorous-based III-V NW sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous Thermal Stability and Ultrahigh Sensitivity of Heterojunction SERS Substrates

This paper reports the design of Ag-Al 2 O 3 -Ag heterojunctions based on Ag nanorods (AgNRs) and their applications as thermally stable and ultrasensitive substrates of surface-enhanced Raman scattering (SERS). Specifically, an ultrathin Al 2 O 3 capping layer of 10 nm on top of AgNRs serves to slow down the surface diffusion of Ag at high temperatures. Then, an additional Ag layer on top of the capping layer creates AgNRs-Al 2 O 3 -Ag heterojunctions, which lead to giant enhancement of electromagnetic fields within the Al 2 O 3 gap regions that could boost the SERS enhancement. As a result of this design, the SERS substrates are thermally stable up to 200 °C, which has been increased by more than 100 °C compared with bare AgNRs, and their sensitivity is about 400% that of pure AgNRs. This easy yet effective capping approach offers a pathway to fabricate ultrasensitive, thermally stable and easily prepared SERS sensors, and to extend SERS applications for high-temperature detections, such as monitoring in situ the molecule reorientation process upon annealing. Such simultaneous achievement of thermal stability and SERS sensitivity represents a great advance in the design of SERS sensors and will inspire the fabrication of novel hetero-nanostructures.

36 MATERIALS SCIENCE↗

Fabrication and Characterization of Non-Equilibrium Plasma-Treated PVDF Nanofiber Membrane-Based Sensors

The effect of a self-pulsing non-equilibrium plasma discharge on piezoelectric PVDF nanofiber membrane was investigated. The plasma discharge was generated in air with a DC power source, with a discharge current of 0.012 mA, a nominal interelectrode separation of 1 mm, and discharge voltage of ~970 V. In a continuous fabrication process, the electrospinning method was used to generate thin nanofiber membrane with a flow rate of 0.7–1 mL h -1 and 25–27 kV voltage to obtain the nanofiber with high sensitivity and a higher degree of alignment and uniformity over a larger area. Plasma treatment was applied on both single layer and multi-layer (three layers) nanomembranes. In addition, simultaneously, the nanofiber membranes were heat-treated at a glass transition temperature (80–120 °C) and then underwent plasma treatment. Fourier-transform infrared (FTIR) spectroscopy showed that the area under the curve at 840 and 1272 cm -1 (β phase) increased due to the application of plasma and differential scanning calorimeter (DSC) indicated an increase in the degree of crystallinity. Finally, PVDF sensors were fabricated from the nanofibers and their piezoelectric properties were characterized. The results suggested that compared to the pristine samples the piezoelectric properties in the plasma and plasma-heat-treated sensors were enhanced by 70% and 85% respectively.

42 ENGINEERING↗

Stereolithographic Fabrication of a Flow Cell For Improved Neurochemical Sensor Testing

The human brain remains a mystery to researchers. Scientists at Lawrence Livermore National Laboratory (LLNL) have developed highly sensitive and flexible multimodal multielectrode arrays (MEAs) with the potential to be both powerful diagnostic and therapeutic tools when dealing with neurological ailments such as Alzheimers, Parkinson’s, Post Traumatic Stress Disorder, and Traumatic Brain Injuries. These MEAs include biosensors in addition to electrodes for electrical stimulation and recording. The transition from the traditional rigid neural probes to the flexible MEAs has led LLNL researchers on the search for alternative testing and characterization methods for flexible devices in vitro. The rigid devices have been shown to be more abrasive and damaging to the brain when implanted, but due to their rigidity – are more robust and resilient to noise artifacts in in vitro testing. The flexible MEAs, similar in size and flexibility to a human hair, cause much less damage in the brain but have had a difficult time maintaining their integrity and collecting data without high-levels of noise due to the formation of inertial eddies (due to increased turbulent flow) moving the flexible MEA during in vitro testing. The goal of this project was to design a fluidic cell to allow for a more constant electrochemical testing & characterization of biosensors on these flexible MEAs. Design and fabrication of the fluidic cell was through the use of CAD software and a stereolithography printer using clear photopolymer resin (appropriate for biomedical use and quality resolution). Flow cells facilitate analyte delivery to biosensor surfaces in a more constant and controlled fashion, allowing for –in this case –a better electrodeposition of thin-film Platinum-Iridium (Pt-Ir) on MEAs of 16 Platinum disc electrodes 50µm in diameter. Platinum-Iridium alloy electrodes have been widely used in biomedical and industrial applications. Iridium adds mechanical stiffness to platinum. PtIr is a FDA approved electrode material for human implantable devices.

36 MATERIALS SCIENCE↗

Development of subminiature multi-sensor hot-wire probes

Limitations on the spatial resolution of multisensor hot wire probes have precluded accurate measurements of Reynolds stresses very near solid surfaces in wind tunnels and in many practical aerodynamic flows. The fabrication, calibration and qualification testing of very small single horizontal and X-array hot-wire probes which are intended to be used near solid boundaries in turbulent flows where length scales are particularly small, is described. Details of the sensor fabrication procedure are reported, along with information needed to successfully operate the probes. As compared with conventional probes, manufacture of the subminiature probes is more complex, requiring special equipment and careful handling. The subminiature probes tested were more fragile and shorter lived than conventional probes; they obeyed the same calibration laws but with slightly larger experimental uncertainty. In spite of these disadvantages, measurements of mean statistical quantities and spectra demonstrate the ability of the subminiature sensors to provide the measurements in the near wall region of turbulent boundary layers that are more accurate than conventional sized probes.

Westphal, Russell V.↗

Ultrasensitive and selective non-enzymatic electrochemical glucose sensor based on hybrid material of graphene nanosheets/graphene nanoribbons/nickel nanoparticle

Highlights: • Nickel nanoparticles incorporated graphene nanosheets/graphene nanoribbons (GS/GNR/Ni) composite was synthesized by in-situ chemical reduction route and the as prepared GS/GNR/Ni modified glassy carbon electrode (GCE) was applied to detect glucose. • The fabricated GS/GNR/Ni/GCE modified electrode exhibits outstanding performance for non-enzymatic glucose sensing with sensitivity (2.3 mA/mM cm{sup 2}), linear range (5 nM - 5 mM) and detection limit (2.5 nM). • GS/GNR/Ni/GCE modified electrode exhibited a high selectivity towards glucose against the interferents, such as ascorbic acid (AA), uric acid (UA), dopamine and sucrose. - Abstract: A fast, highly sensitive and selective non-enzymatic electrochemical glucose sensor based on graphene sheet/graphene nanoribbon/nickel nanoparticles (GS/GNR/Ni) hybrid material modified electrode was fabricated. The hybrid material was synthesized via facile in-situ chemical reduction and characterized by X-ray diffraction, transmission electron microscopy, Raman spectroscopy, cyclic voltammetry and electrochemical impedance spectroscopy. The GS/GNR/Ni/GCE showed high electrochemical activity towards the oxidation of glucose in a 0.1 M NaOH solution. At an applied potential of +0.5 V, it displayed wide linear amperometric response towards glucose from the range of 5 nM–5 mM, with a detection limit of 2.5 nM and sensitivity of 2.3 mA/mM cm{sup 2}. Moreover, the modified electrode was relatively insensitive to commonly interfering species such as dopamine, ascorbic acid, sucrose, uric acid and Cl{sup −} ions. The fabricated sensor with better reproducibility, good long term stability, makes it a promising electrode for the development of effective glucose sensor.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Differential capacitance sensor as position detector for a magnetic suspension densimeter

In the present work, which consists of adapting a magnetic suspension densimeter for use at pressures up to 350 bars, a differential capacitance sensor is developed for use in the servosystem of a magnetic suspension densimeter for detecting the position of a magnetic buoy. This type of sensor has not been used previously in magnetic suspension densimeters. Its design, performance, and advantages are outlined. A cutaway drawing and a schematic diagram of the capacitance sensor and magnetic buoy are presented and described. The concentric-disk design of the sensor capacitor plates and the high degree of symmetry which results from the printed circuit fabrication approach minimize the sensor sensitivity to lateral displacement of the buoy and to the dielectric constant of the surrounding medium. A high-power microscope is necessary to monitor the position of the buoy relative to the support coil.

Frederick, N. V.↗

(abstract) Transmission Electron Microscopy of Al(sub x)Ga(sub 1-x)N/SiC Multilayer Structures Grown on Sapphire Substrates

The potential of wide-band-gap III-V nitrides as ultraviolet sensors and light emitters has prompted an increasing amount of work recently, including the fabrication of the first UV sensors from as-deposited single crystal GaN. We have used high resolution transmission electron microscopy (TEM) to study the microstructure of two novel developments of wide-band-gap III-V nitrides: the growth of ultra-short period GaN/AlN superlattices; and the incorporation of SiC layers into Al(sub x)Ga(sub 1-x)N structures. By varying the relative periods in a GaN/AlN superlattice, the band gap of the composite can be tailored to lie between the elemental values of 365 nm for GaN and 200 nm for AlN. The group IV semiconductor, SiC, has a wide band-gap and has a close lattice match (less than 3 %) to Al(sub x)Ga(sub 1-x)N for growth on the basal plane. Demonstration of epitaxial growth for Al(sub x)Ga(sub 1-x)N/SiC multilayers would introduce a wide band-gap analog to the already existing family of III-V and Si(sub 1-x)Ge(sub x) heteroepitaxial growth systems. Although good quality growth of GaN on SiC substrates has been demonstrated, Al(sub x)Ga(sub 1-x)N/SiC multilayer structures have never been grown and the interfacial structure is unknown.

GaN AlN GaN/AlN↗

Single-Crystal Sapphire Optical Fiber Sensor Instrumentation

This report summarizes technical progress on the program “Single-Crystal Sapphire Optical Fiber Sensor Instrumentation,” funded by the National Energy Technology Laboratory of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. This project was completed in three phases, each with a separate focus. Phase I of the program, from October 1999 to April 2002, was devoted to development of sensing schema for use in high temperature, harsh environments. Different sensing designs were proposed and tested in the laboratory. Phase II of the program, from April 2002 to April 2009, focused on bringing the sensor technologies, which had already been successfully demonstrated in the laboratory, to a level where the sensors could be deployed in harsh industrial environments and eventually become commercially viable through a series of field tests. Also, a new sensing scheme was developed and tested with numerous advantages over all previous ones in Phase II. Phase III of the program, September 2009 to December 2013, focused on development of the new sensing scheme for field testing in conjunction with materials engineering of the improved sensor packaging lifetimes. In Phase I, three different sensing principles were studied: sapphire air-gap extrinsic Fabry-Perot sensors; intensity-based polarimetric sensors; and broadband polarimetric sensors. Black body radiation tests and corrosion tests were also performed in this phase. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. At the beginning of Phase II, in June 2004, the BPDI sensor was tested at the Wabash River coal gasifier facility in Terre Haute, Indiana. Due to business conditions at industrial partner and several logistical problems, this field test was not successful. An alternative high-temperature sensing system using sapphire wafer-based extrinsic Fabry-Perot interferometry was then developed as a significant improvement over the BPDI solution. From June 2006 to June 2008, three consecutive field tests were performed with the new sapphire wafer sensors at the TECO coal gasifier in Tampa, Florida. One of the sensors survived in the industrial coal gasifier for 7 months, over which time the existing thermocouples were replaced twice. The outcome of these TECO field tests suggests that the sapphire wafer sensor has very good potential to be commercialized. However packaging and sensor protection issues need additional development. During Phase III, several major improvements in the design and fabrication process of the sensor have been achieved through experiments and theoretical analysis. Studies on the property of the key components in the sensor head, including the sapphire fiber and sapphire wafer, were also conducted, for a better understanding of the sensor behavior. A final design based on all knowledge and experience has been developed, free of any issues encountered during the entire research. Sensors with this design performed well as expected in lab long-term tests, and were deployed in the sensing probe of the final coal-gasifier field test. Sensor packaging and protection was improved through materials engineering through testing of packaging designs in two blank probe packaging tests at Eastman Chemical in Kingsport, TN. Performance analysis of the blank probe packaging resulted in improve package designs culminating in a 3rd generation probe packaging utilized for the full field test of the sapphire optical sensor and materials designed sensor packaging.

47 OTHER INSTRUMENTATION↗

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines↗

A fiber optic sensor for noncontact measurement of shaft speed, torque, and power

A fiber optic sensor which enables noncontact measurement of the speed, torque and power of a rotating shaft was fabricated and tested. The sensor provides a direct measurement of shaft rotational speed and shaft angular twist, from which torque and power can be determined. Angles of twist between 0.005 and 10 degrees were measured. Sensor resolution is limited by the sampling rate of the analog to digital converter, while accuracy is dependent on the spot size of the focused beam on the shaft. Increasing the sampling rate improves measurement resolution, and decreasing the focused spot size increases accuracy. Digital processing allows for enhancement of an electronically or optically degraded signal.

Madzsar, George C.↗