Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Calibration of Sensors Used for the Quantification of Nuclear Energy Rate Deposition

This present work deals with a collaborative program called GAMMA-MAJOR 'Development and qualification of a deterministic scheme for the evaluation of GAMMA heating in MTR reactors with exploitation as example MARIA reactor and Jules Horowitz Reactor' between the National Centre for Nuclear Research of Poland, the French Atomic Energy and Alternative Energies Commission and Aix Marseille University. One of main objectives of this program is to optimize the nuclear heating quantification thanks to calculation validated from experimental measurements of radiation energy deposition carried out in irradiation reactors. The quantification of the nuclear heating is a key data especially for the thermal, mechanical design and sizing of irradiation experimental devices in specific irradiated conditions and locations. The determination of this data is usually performed by differential calorimeters and gamma thermometers such as used in the experimental multi-sensors device called CARMEN 'Calorimetric en Reacteur et Mesures des Emissions Nucleaires'. In the framework of the GAMMA-MAJOR program a new calorimeter was designed for the nuclear energy deposition quantification. It corresponds to a single-cell calorimeter and it is called KAROLINA. This calorimeter was recently tested during an irradiation campaign inside MARIA reactor in Poland. This new single-cell calorimeter differs from previous CALMOS or CARMEN type differential calorimeters according to three main points: its geometry, its preliminary out-of-pile calibration, and its in-pile measurement method. The differential calorimeter, which is made of two identical cells containing heaters, has a calibration method based on the use of steady thermal states reached by simulating the nuclear energy deposition into the calorimeter sample by Joule effect; whereas the single-cell calorimeter, which has no heater, is calibrated by using the transient thermal response of the sensor (heating and cooling steps). The paper will concern these two kinds of calorimetric sensors. It will focus in particular on studies on their out-of-pile calibrations. Firstly, the characteristics of the sensor designs will be detailed (such as geometry, dimension, material sample, assembly, instrumentation). Then the out-of-pile calibration methods will be described. Furthermore numerical results obtained thanks to 2D axisymmetrical thermal simulations (Finite Element Method, CAST3M) and experimental results will be presented for each sensor. A comparison of the two different thermal sensor behaviours will be realized. To conclude a discussion of the advantages and the drawbacks of each sensor will be performed especially regarding measurement methods. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimization of Thermal Neutron Converter in SiC Sensors for Spectral Radiation Measurements

Optimization of the neutron converter in SiC sensors is presented. The sensors are used for spectral radiation measurements of thermal and fast neutrons and optionally gamma ray at elevated temperature in harsh radiation environment. The neutron converter, which is based on 10B, allows to detect thermal neutrons by means of neutron capture reaction. Two construction of the sensors were used to measure radiation in experiments. Sensor responses collected in experiments have been reproduced by the computer tool created by authors, it allows to validate the tool. The tool creates the response matrix function describing the characteristic of the sensors and it was used for detailed analyses of the sensor responses. Obtained results help to optimize the neutron converter in order to increase thermal neutron detection. Several enhanced construction of the sensors, which includes the neutron converter based on {sup 10}B or {sup 6}Li, were proposed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of sensor technologies for advanced reactors - 250

This paper provides an assessment of sensor technologies and a determination of measurement needs for advanced reactors (AdvRx). It is a summary of a study performed to provide the technical basis for identifying and prioritizing research targets within the instrumentation and control (I and C) Technology Area under the Department of Energy's (DoE's) Advanced Reactor Technology (ART) program. The study covered two broad reactor technology categories: High Temperature Reactors and Fast Reactors. The scope of 'High temperature reactors' included Gen IV reactors whose coolant exit temperatures exceed about {approx}650 deg. C and are moderated (as opposed to fast reactors). To bound the scope for fast reactors, this report reviewed relevant operating experience from US-operated Sodium Fast Reactor (SFR) and relevant test experience from the Fast Flux Test Facility (FFTF). For high temperature reactors the study showed that in many cases instrumentation have performed reasonably well in research and demonstration reactors. However, even in cases where the technology is 'mature' (such as thermocouples), HTGRs can benefit from improved technologies. Current HTGR instrumentation is generally based on decades-old technology and adapting newer technologies could provide significant advantages. For sodium fast reactors, the study found that several key research needs arise around (1) radiation-tolerant sensor design for in-vessel or in-core applications, where possible non-invasive sensing approaches for key parameters that minimize the need to deploy sensors in-vessel, (2) approaches to exfiltrating data from in-vessel sensors while minimizing penetrations, (3) calibration of sensors in-situ, and (4) optimizing sensor placements to maximize the information content while minimizing the number of sensors needed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The NREL Sensor Laboratory: Hydrogen Leak Detection for Large Scale Deployments: Preprint

The NREL Hydrogen Sensor Laboratory was commissioned in 2010 as a resource for sensor developers, end-users, and regulatory agencies within the national and international hydrogen community. The Laboratory continues to provide as its core capability the unbiased verification of hydrogen sensor performance to assure sensor availability and their proper use. However, the mission and strategy of the NREL Sensor Laboratory has evolved to meet the needs of the growing hydrogen market. The Sensor Laboratory program has expanded to support research in conventional and alternative detection methods as hydrogen use expands to large-scale markets as envisioned by the DOE National Clean Hydrogen Strategy and Roadmap. Current research encompasses advanced methods of hydrogen leak detection including stand-off and wide area monitoring approaches for large scale and distributed applications. In addition to safety applications, low-level detection strategies to support the potential environmental impacts of hydrogen and hydrogen product losses along the value chain are being explored. Many of these applications utilize detection strategies that supplement and may supplant the use of traditional point sensors. The latest results of the hydrogen detection strategy research at NREL will be presented.

detection↗

Sensor Qualification for the Development of Advanced Reactors

A temperature sensor qualification device is undergoing development and testing in order to qualify temperature sensors for advanced reactor metrology applications. This device will provide National Institute of Standards and Technology (NIST) traceable performance testing of temperature sensors while under the high radiation environments experienced while in-core. This is completed by utilizing retractable sensors which transfer the measurements from ex-core to in-core sensors. A detailed discussion of the uncertainty propagation associated with this comparative process is provided. Experimental testing of the temperature distribution occurring in the device has begun and is reported on. It is pertinent to minimize this temperature distribution to prevent variation in sensor measurements. This variation will be indistinguishable from sensor drift for in-pile applications and would result in unnecessarily conservative uncertainty bounds.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

An Impedance Humidity Sensor Based on CVD Grown WSe 2 2D Films

2D materials-based planar devices have been sought after for gas and humidity sensor applications owing to their high sensitivity due to their ultrathin nature and increased surface area. Herein, 2D WSe 2 films-based planner devices were fabricated to evaluate their performance for potential application in humidity sensors. The structure and morphology of the WSe 2 sensing films were studied by Raman spectroscopy, photoluminescence, optical microscopy, and scanning electron microscopy (SEM) techniques. The relative humidity-dependent sensing performances of the 2D WSe 2 films were evaluated using current–voltage (I–V), relative impedance, and complex total impedance (electrochemical impedance spectroscopy, EIS) techniques. This sensor showed a very stable and repeatable performance investigated over the period of 18 months. The response and recovery times of the WSe 2 -based impedance sensors were found to be 40 and 30 s, respectively. The WSe 2 sensor exhibits a 2 ± 1% minimum hysteresis at a lower humidity level (50% RH) and around 8 ± 2% maximum hysteresis at relative humidity level (70% RH). This value of hysteresis is in the acceptable range during the initial investigation of any material to explore its potential for application in humidity sensors. The density functional theory (DFT) analysis was performed with the interaction from water molecules of the WSe 2 sample for a better understanding of the sensing mechanism of devices.

2D- WSe2↗

Cybersecurity Attacks in Vehicular Sensors

Today's modern vehicles contain anywhere from sixty to one-hundred sensors and exhibit the characteristics of Cyber-Physical-Systems (CPS). There is a high degree of coupling, cohesiveness, and interactions among vehicle's CPS components (e.g., sensors, devices, systems, systems-of-systems) across sensing, communication, and control layers. Cyber-attacks in the sensing or communication layers can compromise the security of the control layer. This paper provides a detailed review of potential cyber threats related to the sensing layer. Notably, the focus is mainly towards two categories of sensors: vehicle dynamics sensors (e.g., Tire Pressure Monitoring Systems (TPMS), magnetic encoders, and inertial sensors) and environment sensors (e.g., Light Detection and Ranging (LiDAR), ultrasonic, camera, Radio Detection and Ranging (Radar) systems, and Global Positioning System (GPS) units). Furthermore, the paper also offers perspectives through existing countermeasures from literature and stresses the need for data-driven cybersecurity solutions.

97 MATHEMATICS AND COMPUTING↗

Rational Design of Capacitive Pressure Sensors Based on Pyramidal Microstructures for Specialized Monitoring of Biosignals

Abstract There is an increasing demand for specialized pressure sensors in various applications. Previously, capacitive pressure sensors have been shown to have wide versatility in use, with a high degree of potential tuning possible through manipulating the geometry or material selection of the dielectric layer. However, in order to make sensors that are tunable and predictable, the design and fabrication method first needs to be developed. Presented here is an improved fabrication method to achieve tunable, consistent, and reproducible pressure sensors by using a pyramid microstructured dielectric layer along with a lamination layer. The as‐produced sensor performance is able to match predicted trends. Further, a simple model based on this system is developed and its efficacy is experimentally confirmed. Then, the model to predict a wide range of material and microstructure geometric properties prior to device fabrication is used to provide trends on sensor performance. Finally, it is demonstrated that the new method can be used to targetedly design a pressure sensor for a specific application—in vitro pulse sensing.

Ruth, Sara Rachel Arussy↗

Laboratory evaluation of distributed coaxial cable temperature sensors for application in CO 2 sequestration well characterization: Original Research Article: Laboratory evaluation of distributed coaxial cable temperature

Downhole monitoring plays a crucial part in a geological carbon dioxide (CO 2 ) sequestration project, especially in providing early warnings of failure. However, most downhole monitoring technologies are often low in spatial resolution and time-consuming, or expensive and have system longevity issues. To address this issue, a robust and cost-effective distributed coaxial cable Fabry-Perot interferometer-based temperature sensor is proposed for real-time downhole monitoring. The coaxial cable sensor (CCS) was made in house and tested using a high pressure high temperature (HPHT) testing apparatus to study the sensor accuracy, sensitivity, stability, and crosstalk effect in simulated downhole conditions. The laboratory test results indicate that the sensor can work under simulated downhole conditions of pressures up to 1000 psia and temperatures up to 110°C. At 1 ATM, the sensor has an accuracy of about 1%. At 1000 psia, the hysteresis phenomenon is observed, but it is reduced and tends to stabilize after repeated heating and cooling treatments. The pressure crosstalk effect was observed on the flexible cable sensor and minimized on the rigid cable sensor. The temperature and pressure range of the distributed CCS allows long-term in situ monitoring for a well depth up to 2500 feet, which would prove of great value in detecting temperature change associated with wellbore leakage that may lead to groundwater contamination.

54 ENVIRONMENTAL SCIENCES↗

A Novel RFID-Based Strain Sensor for Wireless Structural Health Monitoring

Conventional tools for deformation measurement are widely used for structural health monitoring—i.e. strain gauges and fiber optic sensors—due to their relative low cost and efficiency. However, these techniques still present some drawbacks particularly in limited access locations, since their usage requires some sort of cabling or battery-driven electronics. Thus, in a few situations there may be room for new technologies for deformation monitoring of structures. One of the options are passive radio frequency identification (RFID)-based sensors. In synthesis, like conventional methods, these sensors are attached to the surface a test-piece, but are then remotely interrogated and powered by a transmitter. The solidarity of the sensor to the underlying material means that the detected signal is modified in a way that can be correlated to sample strain in a given direction. This paper encompasses the project of a wireless deformation sensor based on an inverted-F antenna focusing on its miniaturization and performance optimization. For this purpose, such an antenna was designed with the help of finite element modelling tools for operation on a 2.0 mm-thick aluminium sheet, and then experimentally validated through static loading tests. Finally, even though sensors of this kind are still in early developments, results show that RFID sensors represents a promising method for remote deformation assessment in components.

42 ENGINEERING↗

Ten questions concerning low-cost indoor air quality sensors: Perspectives from research and practice

Low-cost indoor air quality (IAQ) sensors are increasingly being used in homes and commercial and public buildings, driven by growing concerns about the impact of air on health, cognitive performance, and occupant wellbeing. These sensors offer a potentially transformative opportunity to increase spatial and temporal coverage of IAQ monitoring at a fraction of the cost of conventional reference instruments. However, their widespread use raises questions around accuracy, calibration, placement, data handling and interpretation, and integration into existing standards and workflows. This paper presents ten critical questions concerning the use of low-cost IAQ sensors in buildings, drawing on the latest empirical research, field deployments, and emerging practice. It discusses potential frameworks for deployment and evaluation, examines current sensor capabilities for measuring common pollutants, identifies methodological gaps in validation and uncertainty quantification, and outlines the extent to which existing IAQ standards can accommodate sensor-based evidence. The paper also explores how monitoring needs and deployment models vary by building type, the potential of real-time IAQ data to support building operations, and the ethical and legal implications of widespread sensor use. While significant challenges remain in ensuring data quality and building stakeholder trust, new applications are emerging through open data initiatives and advances in analytics and visualization. As the technology, science, and standards co-evolve, low-cost IAQ sensors are poised to become integral to routine building operation, building science, and environmental health research.

Parkinson, Thomas↗

Entanglement-enhanced optomechanical sensor array with application to dark matter searches

Abstract Squeezed light has long been used to enhance the precision of a single optomechanical sensor. An emerging set of proposals seeks to use arrays of optomechanical sensors to detect weak distributed forces, for applications ranging from gravity-based subterranean imaging to dark matter searches; however, a detailed investigation into the quantum-enhancement of this approach remains outstanding. Here, we propose an array of entanglement-enhanced optomechanical sensors to improve the broadband sensitivity of distributed force sensing. By coherently operating the optomechanical sensor array and distributing squeezing to entangle the optical fields, the array of sensors has a scaling advantage over independent sensors (i.e., $$\sqrt{M}\to M$$ M → M , where M is the number of sensors) due to coherence as well as joint noise suppression due to multi-partite entanglement. As an illustration, we consider entanglement-enhancement of an optomechanical accelerometer array to search for dark matter, and elucidate the challenge of realizing a quantum advantage in this context.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D printed high performance strain sensors for high temperature applications

Realization of high temperature physical measurement sensors, which are needed in many of the current and emerging technologies, is challenging due to the degradation of their electrical stability by drift currents, material oxidation, thermal strain, and creep. In this paper, for the first time, we demonstrate that 3D printed sensors show a metamaterial-like behavior, resulting in superior performance such as high sensitivity, low thermal strain, and enhanced thermal stability. The sensors were fabricated using silver (Ag) nanoparticles (NPs), using an advanced Aerosol Jet based additive printing method followed by thermal sintering. The sensors were tested under cyclic strain up to a temperature of 500 °C and showed a gauge factor of 3.15 ± 0.086, which is about 57% higher than that of those available commercially. The sensor thermal strain was also an order of magnitude lower than that of commercial gages for operation up to a temperature of 500 °C. An analytical model was developed to account for the enhanced performance of such printed sensors based on enhanced lateral contraction of the NP films due to the porosity, a behavior akin to cellular metamaterials. Here, the results demonstrate the potential of 3D printing technology as a pathway to realize highly stable and high-performance sensors for high temperature applications.

47 OTHER INSTRUMENTATION↗

Evaluation of a fish-friendly self-cleaning horizontal irrigation screen using autonomous sensors

Irrigation modernisation is booming globally because of the increasing demand on water and food. However, irrigation infrastructures can injure fish or entrain them into irrigation water. Screening is an effective method to mitigate fish entrainment. In this study, two autonomous sensor devices, developed and manufactured at Pacific Northwest National Laboratory (Sensor Fish and its miniaturised version, Sensor Fish Mini) were deployed to evaluate the physical and fish passage conditions of a unique horizontal, flat-plate fish and debris screen (known as the Farmers Screen) that was installed in Oregon, USA. Only 1 of the 27 Sensor Fish Mini releases had a severe acceleration event, whereas 0 of the 37 Sensor Fish releases had severe events. The rates of severe events and amplitudes of accelerations at the Farmers Screen were significantly lower than those at other hydraulic structures, including a fish-friendly surface weir that recorded nearly 100% fish survival. Overall, the results indicated that the Farmers Screens can provide safe downstream passage for fish at irrigation diversions. This study also demonstrated that the Sensor Fish technology, including Sensor Fish Mini, is a suitable technology for evaluating irrigation structures and providing important information for the development of sustainable irrigation.

47 OTHER INSTRUMENTATION↗

Modeling active control of resistive wall mode with power saturation and sensor noise on HL-2M

The resistive wall mode (RWM) control on the HL-2M tokamak is simulated with the MARS-F code (Liu et al 2000 Phys. Plasmas 7 3681), aiming at quantifying control current and voltage requirements when more realistic issues are taken into account, i.e. the control power saturation and the sensor signal noise. The fluid model predicts a narrow stability region for the n = 1 RWM without magnetic feedback, in the 2D parameter space of the plasma pressure versus the toroidal flow speed. Magnetic feedback can fully stabilize the RWM on HL-2M. Without considering the voltage limitation and the sensor signal noise, it is found that plasma flow helps active control of the mode, by reducing the required critical feedback gain for both flux-to-current and flux-to-voltage control schemes. In the absence of the sensor signal noise, the lowest control voltage saturation level, below which the RWM control is lost, is found to roughly satisfy a linear relation to the plasma flow frequency, indicating that subsonic plasma flow is effective in relaxing the control power requirement for the RWM feedback stabilization. The presence of the sensor signal noise substantially modifies the feedback results. A statistical study finds that the sensor signal noise, with the standard deviation of 0.1 G on HL-2M, roughly doubles the required control voltage for successful mode control. The synergistic stabilization effect due to plasma flow is somewhat weakened by the presence of the sensor signal noise. At a given rotation, the tolerable voltage limit generally increases with increasing feedback gain due to the sensor signal noise.

Physics↗

Tunable polyvinyl chloride (PVC) and thermoplastic polyurethane (TPU)-based soft polymer gel sensors

Abstract Polyvinyl chloride (PVC) gels have recently been found to exhibit mechanoelectrical transduction under mechanical deformation. These mechanoelectrical properties of PVC gels are largely uncharacterized and the underlying transduction mechanisms are currently unknown. These soft electroactive polymers have tunable properties such as modulus and response voltage based on physical dimensions and the amount of plasticizer content within the material making them ideal candidates for complaint sensors. This study aims to investigate PVC gels comprised of various plasticizers to further investigate underlying mechanisms of mechanoelectrical transduction and broaden possible sensing applications. Plasticizers used in this study include dibutyl adipate, dibutyl phthalate, dioctyl phthalate, otherwise known as bis(2-ethylhexyl) phthalate, diisodecyl adipate, and the environmentally friendly biodegradable plasticizer acetyl tributyl citrate (ATBC). ATBC is often used in cosmetics and food packaging applications and is even used as a food additive which may lead to future biocompatibility for these gel sensors. These plasticizers are used to produce PVC gel sensors that are experimentally tested for mechanoelectrical transduction properties and sensing performance. In this study, a Langmuir adsorptive model is fit to the collected mechanoelectrical transduction data. These results are also nondimensionalized and compared to the characteristic dimensionless Langmuir adsorptive model. This simple model agrees very well with the experimental data. Additionally, a study on the mechanoelectrical transduction of an alternative polymer lattice structure, thermoplastic polyurethane (TPU), is discussed. This is a novel electroactive polymer investigated for mechanoelectrical transduction properties. This portion of the study aims to further knowledge of underlying mechanisms of mechanoelectrical transduction as well as show feasibility of additional lattices for soft polymer gel sensors. These TPU gel sensors show strikingly similar mechanoelectrical transduction properties to analogous PVC gels, insinuating that the polymer structure has a limited role in the underlying sensing mechanism and PVC itself is not unique to polymer gel sensing. The TPU-based soft polymer gel sensors however do display some level of mechanoelectrical hysteresis which may be attributed to viscoelastic properties and display a small amount of fatigue possibly due to exudation of liquid plasticizer. This study provides further characterization of mechanoelectrical response for varying plasticizers, provides a theoretical framework for underlying mechanisms, and displays the potential for further polymeric gel sensors.

Instruments & Instrumentation↗