Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Breakdown in Tantalum Capacitors

Failures in tantalum capacitors can be considered as a time-dependent-breakdown and reliability of all types of capacitors, including wet, MnO2 and polymer cathode parts, depends on the efficiency of self-healing that can mend parts after breakdown. A mechanism of self-healing in MnO2 capacitors is associated with oxygen reduction in the cathode layer and isolation of the breakdown site with high-resistive Mn2O3/Mn3O4 compositions. Although this mechanism is commonly accepted, details of self-healing have not been analyzed sufficiently yet, and the effects of scintillations on behavior of the parts has not been fully understood. There is a lack of data on the self-healing efficiency in different lots of capacitors. Even less is known about self-healing in polymer tantalum capacitors. In this work, different types of polymer and MnO2 capacitors have been tested for scintillation breakdown using a constant current stress (CCS) technique modified to allow detection of the amplitudes and durations of current spikes during breakdown. Characteristics of the parts and in particular leakage currents were measured to assess the efficiency of self-healing and improve screening processes for tantalum capacitors. Damaged sites were localized using infrared camera and their appearance analyzed after deprocessing and crosssectioning. Thermal effects during scintillations have been modeled, self-healing processes in polymer and MnO2 cathode capacitors discussed, and mechanisms of breakdown based on the growth of conductive filaments in the dielectric suggested.

tantalum polymer capacitors↗

Ka-band and X-band observations of the solar corona acquired during the Cassini 2001 superior conjunction

Simultaneous dual-frequency Ka-band (32 GHz) and X-band (8.4 GHz) carrier signal data have been acquired during the superior conjunction of the Cassini spacecraft June 2001, using the NASA Deep Space Network's facilities located in Goldstone, California. The solar elongation angle of the observations varied from -4.1 degrees (-16 solar radii) to -0.6 degrees (-2.3 solar radii). The observed coronal and solar effects on the signals include spectral broadening, amplitude scintillation, phase scintillation, and increased noise. The measurements were generally consistent with existing solar models, except during solar transient events when the signatures of the measurements were observed to increase significantly above the quiet background levels. This is the second solar conjunction of Cassini for which simultaneous X/Ka data were acquired. Both solar conjunctions, conducted in May 2000 and June 2001, occurred near the peak of the current 11 year solar cycle.

propagation scintillation spectral broadening↗

The Fluorescent Decay of CsI(T1) Excited by Charged Particles

The fluorescence from a CsI(0.08% T1) scintillator excited by charged particles which come to a stop within the scintillator has been measured for alpha particles, deuterons, and protons. In the region 0.1 to 0.6 microseconds after its initial rise, the fluorescent decay can be accurately described by a simple exponential. The characteristic time for this exponential decay has been measured at several energies up to 28.7 MeV for a particles and 7.2 MeV for protons. We have found a linear relationship between this decay time and the logarithm of the particle energy, τ = k ln E + τo, where k and τo are constants which are characteristic of the type of stopping particle.

Womack, E. A.↗

Measurement of the nuclear electromagnetic cascade development in glass at energies above 200 GeV

The longitudinal development of nuclear-electromagnetic cascades with energies greater than 200 GeV was measured in a low-Z (glass) absorber. This was done in the course of operating an ionization spectrometer at mountain altitude in an experiment to study the properties of gamma rays emitted from individual interactions at energies around 10,000 GeV. The ionization produced by a cascade is sampled by 20 sheets of plastic scintillator spaced uniformly in depth every 2.2 radiation lengths. Adjacent pairs of scintillators are viewed by photomultipliers which measure the mean ionization produced by an individual cascade in 10 layers each 1.1 interaction length (4.4 radiation lengths) thick. The longitudinal development of the cascades was measured for about 250 cascades having energies ranging from 200 GeV to 2500 GeV. The observations are compared with the predictions of calculations made for this specific spectrometer using a three-dimensional Monte Carlo model of the nuclear-electromagnetic cascade.

Gillespie, C. R.↗

A large area detector for neutrons between 2 and 100 MeV

A neutron detector sensitive from 2 to 100 MeV is described. The detector is designed for high altitude balloon flight to measure the flux, energy and direction of albedo neutrons from the earth and to search for solar neutrons. A neutron scatter from a proton is required in each of two liquid scintillator tanks spaced 1 meter apart. The energy of the recoil proton in the first tank is obtained from pulse height analysis of the scintillator output. The energy of the recoil neutron is obtained from its time of flight between the tanks. The detector has been calibrated with 15.3 MeV neutrons and mu mesons. The minimum detectable flux is 10(-4) neutron/sq cm/sec at a counting rate of one per minute; the energy resolution is 12% at 15 MeV and 30% at 100 MeV. The angle between the incoming neutron and the recoil neutron is measured to + or - 10 deg.

Grannan, R. T.↗

Modification of codes NUALGAM and BREMRAD, Volume 1

The NUGAM2 code predicts forward and backward angular energy differential and integrated distributions for gamma photons and fluorescent radiation emerging from finite laminar transport media. It determines buildup and albedo data for scientific research and engineering purposes; it also predicts the emission characteristics of finite radioisotope sources. The results are shown to be in very good agreement with available published data. The code predicts data for many situations in which no published data is available in the energy range up to 5 MeV. The NUGAM3 code predicts the pulse height response of inorganic (NaI and CsI) scintillation detectors to gamma photons. Because it allows the scintillator to be clad and mounted on a photomultiplier as in the experimental or industrial application, it is a more practical and thus useful code than others previously reported. Results are in excellent agreement with published Monte Carlo and experimental data in the energy range up to 4.5 MeV.

Steyn, J. J.↗

Results of the Balloon Atmospheric Propagation Experiment flights of 1970 (BAPE 1)

Two laser beams, one argon (5145 A) and one CO2 (10.6 microns), were propagated over vertical path from the ground to receivers located above the atmosphere, and the scintillation of the beams was measured. Simulataneous measurement of the state of turbulence along the path permitted the comparison of scintillation statistics with theory. The effects of atmospheric turbulence over a vertical or near-vertical path are discussed.

Minott, P. O.↗

Electron showers of high primary energy in lead.

The development of electron cascade showers in a lead-scintillator sandwich of 8 plastic scintillators in about 20 radiation lengths of lead has been investigated. This detector, which was used for cosmic-ray studies, has been calibrated with electrons with energies from 2 to 15 GeV at SLAC. Measured shower profiles are presented, and expressions are given which allow an extrapolation of the measured data up to energies around 1000 GeV. The results are compared with analytical shower theories and Monte Carlo calculations.

Mueller, D.↗

Search for 1/3e and 2/3e charged quarks in the cosmic radiation at 2750-m altitude.

A scintillation counter telescope consisting of eight liquid scintillation counters and four wide-gap spark chambers was used to search for particles with electric charge 1/3e and 2/3e in cosmic rays at 2750 m above sea level. No such particles were detected during the 1500-hr experimental run. Upper limits on the vertical fluxes are established, and estimates of the corresponding sea-level fluxes are made for comparison with previous results.

Cox, A. J.↗

Amplitude fading of simultaneous transionospheric L-band and VHF signals received at the geomagnetic equator

At Ancon, Peru, simultaneous observations of 1550-MHz and 136-MHz signals from the ATS 5 and Intelsat-1 spacecraft showed ionospheric fading as great as 27 db at 136 MHz and 6 db at 1550 MHZ. The observations were made on 48 days during the 1970 autumnal and 1971 vernal equinox periods. Comparison of the two frequencies, in respect to rates and depths of fades, is made. Statistical distributions of the received signal levels during ionospheric scintillation occurrences are presented which may be of use to communications system engineers with operational requirements in the equatorial regions. The distributions show that during expected periods of scintillation, the L band signal typically falls 1.1 db below the median for 1.0 percent of the time, and the VHF signal falls 11.5 db below the median for 1.0 percent of the time.

Sessions, W. B.↗

Evidence for a continuous, power law, electron density irregularity spectrum

The spectral form of the irregularities in electron density that cause interplanetary scintillation (IPS) of small angular diameter radio sources is discussed. The intensity scintillation technique always yields an irregularity scale size, which is of the order of the first Fresnel zone for the wavelength at which the observations are taken. This includes not only the radio wavelength measurements of the structure of the interplanetary medium, but also radio wavelength measurements of the irregularity structure of the ionosphere and interstellar medium, and optical wavelength measurements of the irregularity structure of the atmosphere.

Cronyn, W. M.↗

The cosmic gamma-ray spectrum between 0.3 and 27 MeV measured on the Apollo 15

The spectrum of the total (diffuse and discrete sources) cosmic gamma-ray background over the 0.3 to 27 MeV range was measured with a 7.0 cm diameter x 7.0 cm long uncollimated NaI(Tl) scintillation counter located on a boom 7.6 m from the Apollo 15 service module. Data on cosmic gamma-rays were taken during transearth coast at various boom extensions, detector gains, and with the plastic anticoincidence scintillator enabled and disabled.

Trombka, J. I.↗

Balloon atmospheric propagation experiment measurements

High altitude balloon measurements on laser beam fading during propagation through turbulent atmosphere show that a correlation between fading strength and stellar scintillation magnitudes exists. Graphs for stellar scintillation as a function of receiver aperture are used to predict fading bit error rates for neodymium-yag laser communication system.

Minott, P. O.↗

Research at the Stanford Center for Radar Astronomy

Research is reported into the physical phenomena of space and planetary environments, and related applications of the techniques of radio science and technology. Reports presented include: studies of refraction, scintillation and retardation effects; bistatic radar; radar studies of planetary atmospheres; ionospheric scintillation; magnetospheric radio noise emission; Helmholtz waves in the boundary layer; and Bragg scatter probing of sea state. A list is included of recent publications.

Source record↗

SAO/NASA joint investigation of astronomical viewing quality at Mount Hopkins Observatory: 1969-1971

Quantitative measurements of the astronomical seeing conditions have been made with a stellar-image monitor system at the Mt. Hopkins Observatory in Arizona. The results of this joint SAO-NASA experiment indicate that for a 15-cm-diameter telescope, image motion is typically 1 arcsec or less and that intensity fluctuations due to scintillation have a coefficient of irradiance variance of less than 0.12 on the average. Correlations between seeing quality and local meteorological conditions were investigated. Local temperature fluctuations and temperature gradients were found to be indicators of image-motion conditions, while high-altitude-wind conditions were shown to be somewhat correlated with scintillation-spectrum bandwidth. The theoretical basis for the relationship of atmospheric turbulence to optical effects is discussed in some detail, along with a description of the equipment used in the experiment. General site-testing comments and applications of the seeing-test results are also included.

Pearlman, M. R.↗

A relation between cosmic-ray fluctuations, gradient, and diffusion coefficient

The motion of charged particles in a stochastic magnetic field is considered via a generalized quasi-linear expansion of Liouville's equation. The result is an equation relating cosmic-ray scintillations to particle gradients and to magnetic-field fluctuations (or diffusion coefficient). The resulting theory may be regarded as an example of a fluctuation-dissipation phenomenon, in which the diffusion coefficient plays the role of the dissipative parameter. The resonant interaction between particles and the random interplanetary magnetic field is considered explicitly, and it is shown that observed scintillations of high-energy (about 1 GeV) cosmic rays may be reasonably explained by the model.

Owens, A. J.↗

Digital receiver simulation

Digital simulation of the data link for the Saturn-Uranus spacecraft design is summarized. The data link is a 40 watt, 400 MegaHertz, 44 bit-a-second link, a power starved link, and uses convolution coding. Aspects of the link of particular interest are atmospheric scintillation and the Doppler to data rate ratio. The major characteristics of the scintillation are modeled in terms of tapped delay lines. A candidate system design and receiver design is developed. A computer flow diagram depicting a routine for the error rate and one for acquisition is presented. Various coding algorithms are analyzed since the convolution code is sensitive to the distribution of error and the actual pattern of the error.

Hinrichs, C.↗