Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Multimodal Mass Spectrometry Imaging (MSI) of Archean and Jurassic Geologic Samples

Current geochemical analytical techniques such as gas chromatography-mass spectrometry (GC-MS and $G\acute{C}GC-MS$) can effectively determine the composition and structure of the organic biosignatures within a sample but cannot resolve the spatial distribution of organic biosignatures within rocks or sediments. The spatial distribution can be used to determine the character of the organic biosignatures [1], which can be indigenous (deposited with host rocks), non-indigenous (incorporated after deposition via fluid migration), or contaminant. Determining the character of organic biosignatures is critical for ancient samples [2] and will be critical if organics are observed in samples returned from Mars [3].Fs-LDPI-MS has the ability to map organic compounds across the surface of samples at 2 - 10 μm lateral resolution. Furthermore, fs-LDPI-MS can be used to carry out multiple analyses in the same location for micron-scale analysis of previously buried material [4]. We used fs-LDPI-MS to examine a ~164 million year old organic-rich mudstone from SW England (14.2 wt. % total organic carbon) [5] and determined the spatial distribution of likely indigenous components buried below potentially contaminated surface layers.We then used ToF-SIMS to re-analyze the mudstone to directly compare ToF-SIMS to fs-LDPI-MS datasets, and to analyze a series of ~2.7 billion year old geologic samples from Timmins, ON, CA [6]. Ref. [6] previously analyzed the Archean samples and observed a series of archaeal biomarkers, as well as hopanes and steranes. Using ToF-SIMS analysis, we were able to detect hopanes and steranes in the mudstone samples, but not in the Archean samples indicating that the hopanes and steranes are most likely contaminants in the Archean samples. We also did not observe the archaeal biomarkers; however, this may be from the lack of molecular ion preservation during ToF-SIMS.

Pasterski, Michael↗

Electronic device and method for compressing sampled data

An electronic device for compressing sampled data comprises a memory element and a processing element. The memory element is configured to store sampled data points and sampled times. The processing element is in electronic communication with the memory element and is configured to receive a plurality of sampled data points, a slope for each sampled data point in succession, the slope being a value of a change between the sampled data point and its successive sampled data point, and store the sampled data point in the memory element when the slope changes in value from a previous sampled data point.

Morrow, Mitchell Hedges↗

Single-Use Destructive Assay for Uranium Hexafluoride Sampling

Sampling uranium hexafluoride (UF6) for the determination of enrichments by destructive analysis (DA) is a critical component in the International Atomic Energy Agency’s layered safeguards approach for uranium processing facilities. Typically, gram-quantity UF6 samples are collected during inspections and stored under tag-and-seal until transportation to an off-site analytical laboratory. The shipping times can be long, and evolving restrictions on radioactive/corrosive materials shipments may increasingly limit the IAEA’s ability to transport UF6 samples easily. Pacific Northwest National Laboratory has developed a low-cost UF6 sampling technology called Single-Use Destructive Assay (SUDA) that addresses these challenges, as well as provides DA sample geometries that can be tailored for different analytical methods, including potential on-site analyses. The SUDA samplers, along with a unique holder, are designed for direct attachment to existing taps at uranium processing facilities, allowing gaseous UF6 to come into direct contact with a zeolite film. The SUDA technology features the ability to capture uranium in a more easily shipped and handled form as the solid, more stable, and relatively less hazardous hydrated uranyl fluoride (UO2F2•nH2O), which is formed through the controlled hydrolysis of UF6. We have recently simulated uranium collection under enrichment plant sampling conditions to further improve our understanding of SUDA sampling. Presented here is our recent work on measuring the relationship between sampling conditions and uranium collection, which includes control of the uranium-mass-to-zeolite ratio and assessing variable UF6 gas and sampling parameters that can affect collection using the SUDA sampler.

Pope, Timothy R.↗

Data Report on Post-Irradiation Dimensional Change of AGC-1 Samples

This report documents the measured post irradiation dimensional change in the AGC-1 samples. The AGC-1 capsule is the first in six planned irradiation capsules comprising the Advanced Graphite Creep (AGC) test series. AGC-1 irradiation began September 5, 2009 in the Advanced Test Reactor (ATR) and was completed on January 8, 2011. The capsule was cooled for 3 months in the ATR Canal, and then shipped to MFC in April 2011 for disassembly and sample extraction. After extraction the samples were shipped to the INL Research Center (IRC) for initial post-irradiation examination (PIE) and storage in the irradiated graphite vault. The AGC-1 capsule design contained “matched pair” samples to ascertain the irradiation-induced dimensional changes and levels of creep experienced in different graphite types. The irradiation-induced dimensional changes and creep levels are determined by comparing the total dimensional change for stressed and unstressed samples of the same type of graphite exposed to the same dose levels and at similar temperatures. Under irradiation creep (i.e. permanent strain due to irradiation, stress, and temperature) the stressed samples should demonstrate more dimensional change than the unstressed samples. This additional dimensional change in the stressed samples is designated as “irradiation-induced creep” in graphite. The data are further presented using the parameters influencing dimensional change in graphite; levels of induced stress, temperature, graphite type, and dose. However, the AGC-1 post-irradiation examination is a significant endeavor and this data report serves to provide irradiation-induced dimensional change data for AGC capsule design refinement as well as a status on the progress of the PIE activities. The dimensional changes of both the samples and graphite body are very important to the design of the future AGC capsules (AGC-3 through AGC-6) and are provided as soon as the data are available in order to determine whether design changes to the next capsule are required. A complete evaluation of the irradiation-induced dimensional change data will be performed for a final AGC-1 PIE report that will include full analysis of pre- and post-irradiation data, with verified AGC-1 irradiation conditions of temperature and dose.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Per-instruction energy debugging using instruction sampling hardware

A processor utilizes instruction based sampling to generate sampling data sampled on a per instruction basis during execution of an instruction. The sampling data indicates what processor hardware was used due to the execution of the instruction. Software receives the sampling data and generates an estimate of energy used by the instruction based on the sampling data. The sampling data may include microarchitectural events and the energy estimate utilizes a base energy amount corresponding to the instruction executed along with energy amounts corresponding to the microarchitectural events in the sampling data. The sampling data may include switching events associated with hardware blocks that switched due to execution of the instruction and the energy estimate for the instruction is based on the switching events and capacitance estimates associated with the hardware blocks.

Wei, Shijia↗

WHOLESCALE Catalog of Rock Samples at San Emidio Nevada collected in January 2021

This submission contains information on thirty-six rock samples collected from San Emidio, Nevada during January, 2021 for Subtask 2.3 of the WHOLESCALE project. The following resources include a .zip of rock sample photos taken in the field, a .zip of rock sample photos taken in the laboratory at UW-Madison, and an excel catalog of rock samples with information on sample name, rock type, coordinates of sample location, structural measurements, field notes, observations for plug preparation (e.g., weathering, ability to be cut and cored), and rock descriptions. It should be noted that not every sample was photographed in the field. Names and descriptions of rock formation units are taken from Rhodes et al. (2011). The README.txt file is a description of this submission.

15 GEOTHERMAL ENERGY↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Rotary Percussive Sample Acquisition Tool (SAT): Hardware Development and Testing

In support of a potential Mars Sample Return (MSR) mission an Integrated Mars Sample Acquisition and Handling (IMSAH) architecture has been proposed to provide a means for Rover-based end-to-end sample capture and caching. A key enabling feature of the architecture is the use of a low mass sample Acquisition Tool (SAT) that is capable of drilling and capturing rock cores directly within a sample tube in order to maintain sample integrity and prevent contamination across the sample chain. As such, this paper will describe the development and testing of a low mass rotary percussive SAT that has been shown to provide a means for core generation, fracture, and capture.

Integrated Mars Sample Acquisition and Handling (I↗

How to avoid multiple scattering in strongly scattering SANS and USANS samples

Small Angle Neutron Scattering (SANS) and Ultra Small Angle Neutron Scattering (USANS) are the only available experimental techniques to provide seamless non-destructive measurements of the geometry of the accessible and inaccessible pore structure of rocks from sub-nanopore size to the scale of macropores. They have therefore become the measurement of choice for tight reservoir rocks such as organic rich shales. A simplifying assumption in the analysis is, however, that during the path of neutrons through the sample each neutron is only scattered once. Shales are samples with a high scattering power and Multiple Scattering (MS) may occur which requires special modelling for deconvolution of the results. The approach to avoid MS is to simply reduce the sample thickness to <0.15–0.5 mm. Here, in this work, we present a systematic method on wavelength selection and preparation of samples to optimise extraction of microstructural data and minimise parasitic errors. Experimentally measured SAS transmission (TSAS) values are used as a practical criterion for estimation of the extent of MS. Generous beamtime allocations allowed robust testing revealing that sample thicknesses can be twice as thick as predicted using the standard protocol. Analysing thicker samples is particularly beneficial for statistically relevant characterisation of heterogeneous samples making the new protocol the method of choice for such samples.

(U)SANS↗

Adversarial sampling of unknown and high-dimensional conditional distributions

Many engineering problems require the prediction of realization-to-realization variability or a refined description of modeled quantities. In that case, it is necessary to sample elements from unknown high-dimensional spaces with possibly millions of degrees of freedom. While there exist methods able to sample elements from probability density functions (PDF) with known shapes, several approximations need to be made when the distribution is unknown. In this paper the sampling method, as well as the inference of the underlying distribution, are both handled with a data-driven method known as generative adversarial networks (GAN), which trains two competing neural networks to produce a network that can effectively generate samples from the training set distribution. In practice, it is often necessary to draw samples from conditional distributions. When the conditional variables are continuous, only one (if any) data point corresponding to a particular value of a conditioning variable may be available, which is not sufficient to estimate the conditional distribution. This work handles this problem using an a priori estimation of the conditional moments of a PDF. Herein, two approaches, stochastic estimation, and an external neural network are compared for computing these moments; however, any preferred method can be used. The algorithm is demonstrated in the case of the deconvolution of a filtered turbulent flow field. It is shown that all the versions of the proposed algorithm effectively sample the target conditional distribution with minimal impact on the quality of the samples compared to state-of-the-art methods. Additionally, the procedure can be used as a metric for the diversity of samples generated by a conditional GAN (cGAN) conditioned with continuous variables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of sampling frequency and estimation method on phosphorus load uncertainty in the Western Lake Erie Basin, Ohio, USA

Accurate estimates of nutrient loads are necessary to identify critical source areas and quantify the impact of management practices on pollutant export. Previous studies have investigated nutrient load estimate uncertainty, but they often focus on nutrient loads estimated using an interpolation method for large-scale watersheds with short-term datasets. The study objective was to quantify uncertainty in soluble reactive phosphorus (SRP), total phosphorus (TP), and suspended solids (SS) load estimates from two small (<10 3 km 2 ) agricultural watersheds in the western Lake Erie Basin resulting from different sampling frequencies. Each watershed had high temporal resolution datasets of discharge (15 min) and nutrient concentration (1 to 3 samples per day) collected over a 30-year period (1990–2020). Firstly, SRP, TP, and SS loads were calculated using the high temporal resolution datasets, which was assumed as “true loads”. Secondly, the high temporal concentration data were decomposed to semiweekly, weekly, biweekly, and monthly sampling and annual loads were estimated using four common load estimation methods to assess the effect of sampling frequency and load estimation method on load estimate error. Across the four different methods, the composite method had the lowest relative root mean square and absolute bias, but the rectangular interpolation method was the most precise. Furthermore, even with semiweekly sampling, the composite method resulted in an unacceptable level of precision (average imprecision = 39 %), while the interpolation method resulted in an unacceptable bias (average absolute bias = 16 %). Because neither method could provide acceptable accuracy and precision at the lowest decrease in sampling (e.t. semiweekly sampling), continued daily sampling is recommended in these watersheds.

54 ENVIRONMENTAL SCIENCES↗

Adjoint Klein-Nishina Sampling Methods: Efficiency, Speed and Applications

Three new rejection sampling methods for generating samples from the adjoint Klein-Nishina cross section are discussed: the two-branch rejection sampling procedure, the three-branch linear rejection sampling procedure and the three-branch inverse rejection sampling procedure. These methods have all been implemented in the Framework for REsearch in Nuclear ScIence and Engineering (FRENSIE). The efficiency and sample generation rate of each of these methods are evaluated to characterize the methods and to make recommendations regarding their use. The use of these methods in realistic transport simulations is also evaluated by incorporating a scattering function into the sampling process. Furthermore, the results of an infinite medium problem are presented to verify that the sampling procedure can be used in an adjoint Monte Carlo simulation to generate results that are in agreement with an equivalent forward simulation.

97 MATHEMATICS AND COMPUTING↗

Mars Sample Return Using Commercial Capabilities: Mission Architecture Overview

Mars Sample Return (MSR) is the highest priority science mission for the next decade as recommended by the recent Decadal Survey of Planetary Science. This paper presents an overview of a feasibility study for an MSR mission. The objective of the study was to determine whether emerging commercial capabilities can be used to reduce the number of mission systems and launches required to return the samples, with the goal of reducing mission cost. We report the feasibility of a complete and closed MSR mission design using the following scenario that covers three synodic launch opportunities, beginning with the 2022 opportunity: A Falcon Heavy injects a SpaceX Red Dragon capsule and trunk onto a Trans Mars Injection (TMI) trajectory. The capsule is modified to carry all the hardware needed to return samples collected on Mars including a Mars Ascent Vehicle (MAV), an Earth Return Vehicle (ERV), and hardware to transfer a sample collected in a previously landed rover mission to the ERV. The Red Dragon descends to land on the surface of Mars using Super Sonic Retro Propulsion (SSRP). After previously collected samples are transferred to the ERV, the single-stage MAV launches the ERV from the surface of Mars. The MAV uses a storable liquid bi-propellant propulsion system to deliver the ERV to a Mars phasing orbit. After a brief phasing period, the ERV, which also uses a storable bi-propellant system, performs a Trans Earth Injection (TEI) burn. Upon arrival at Earth, the ERV performs Earth and lunar swing-bys and is placed into a lunar trailing circular orbit - an Earth orbit, at lunar distance. A later mission, using Dragon and launched by a Falcon Heavy, performs a rendezvous with the ERV in the lunar trailing orbit, retrieves the sample container and breaks the chain of contact with Mars by transferring the sample into a sterile and secure container. With the sample contained, the retrieving spacecraft makes a controlled Earth re-entry preventing any unintended release of pristine martian materials into the Earth's biosphere. The analysis methods employed standard and specialized aerospace engineering tools. Mission system elements were analyzed with either direct techniques or by using parametric mass estimating relationships (MERs). The architecture was iterated until overall mission convergence was achieved on at least one path. Subsystems analyzed in this study include support structures, power system, nose fairing, thermal insulation, actuation devices, MAV exhaust venting, and GN&C. Best practice application of loads, mass growth contingencies, and resource margins were used. For Falcon Heavy capabilities and Dragon subsystems we utilized publically available data from SpaceX, published analyses from other sources, as well as our own engineering and aerodynamic estimates. Earth Launch mass is under 11 mt, which is within the estimated capability of a Falcon Heavy, with margin. Total entry masses between 7 and 10 mt were considered with closure occurring between 9 and 10 mt. Propellant mass fractions for each major phase of the EDL - Entry, Terminal Descent, and Hazard Avoidance - have been derived. An assessment of the effect of the entry conditions on the thermal protection system (TPS), currently in use for Dragon missions, shows no significant stressors. A useful payload mass of 2.0 mt is provided and includes mass growth allowances for the MAV, the ERV, and mission unique equipment. We also report options for the MAV and ERV, including propulsion systems, crewed versus robotic retrieval mission, as well as direct Earth entry. International planetary protection policies as well as verifiable means of compliance will have a large impact on any MSR mission design. We identify areas within our architecture where such impacts occur. We also describe preliminary compliance measures that will be the subject of future work. This work shows that emerging commercial capabilities as well as new methodologies can be used to efficiently support an important planetary science objective. The work also has applications for human exploration missions that use propulsive EDL techniques

Red Dragon↗

Mars Sample Return Using Commercial Capabilities: Mission Architecture Overview

Mars Sample Return (MSR) is the highest priority science mission for the next decade as recommended by the recent Decadal Survey of Planetary Science. This paper presents an overview of a feasibility study for a MSR mission. The objective of the study was to determine whether emerging commercial capabilities can be used to reduce the number of mission systems and launches required to return the samples, with the goal of reducing mission cost. The major element required for the MSR mission are described and include an integration of the emerging commercial capabilities with small spacecraft design techniques; new utilizations of traditional aerospace technologies; and recent technological developments. We report the feasibility of a complete and closed MSR mission design using the following scenario that covers three synodic launch opportunities, beginning with the 2022 opportunity: A Falcon Heavy injects a SpaceX Red Dragon capsule and trunk onto a Trans Mars Injection (TMI) trajectory. The capsule is modified to carry all the hardware needed to return samples collected on Mars including a Mars Ascent Vehicle (MAV); an Earth Return Vehicle (ERV); and hardware to transfer a sample collected in a previously landed rover mission to the ERV. The Red Dragon descends to land on the surface of Mars using Supersonic Retro Propulsion (SRP). After previously collected samples are transferred to the ERV, the single-stage MAV launches the ERV from the surface of Mars to a Mars phasing orbit. The MAV uses a storable liquid, pump fed bi-propellant propulsion system. After a brief phasing period, the ERV, which also uses a storable bi-propellant system, performs a Trans Earth Injection (TEI) burn. Once near Earth the ERV performs Earth and lunar swing-bys and is placed into a Lunar Trailing Orbit (LTO0 - an Earth orbit, at lunar distance. A later mission, using a Dragon and launched by a Falcon Heavy, performs a rendezvous with the ERV in the lunar trailing orbit, retrieves the sample container and breaks the chain of contact with Mars by transferring the sample into a sterile and secure container. With the sample contained, the retrieving spacecraft, makes a controlled Earth re-entry preventing any unintended release of pristine Martian materials into the Earth's biosphere. Other capsule type vehicles and associated launchers may be applicable. The analysis methods employed standard and specialized aerospace engineering tools. Mission system elements were analyzed with either direct techniques or by using parametric mass estimating relationships (MERs). The architecture was iterated until overall mission convergence was achieved on at least one path. Subsystems analyzed in this study include support structures, power system, nose fairing, thermal insulation, actuation devices, MAV exhaust venting, and GN&C. Best practice application of loads, mass growth contingencies, and resource margins were used. For Falcon Heavy capabilities and Dragon subsystems we utilized publically available data from SpaceX; published analyses from other sources; as well as our own engineering and aerodynamic estimates. Earth Launch mass is under 11 mt, which is within the estimated capability of a Falcon Heavy, with margin. Total entry masses between 7 and 10 mt were considered with closure occurring between 9 and 10 mt. Propellant mass fractions for each major phase of the EDL - Entry, Terminal Descent, and Hazard Avoidance - have been derived. An assessment of the entry conditions on the thermal protection system (TPS), currently in use for Dragon missions, has been made. And shows no significant stressors. A useful mass of 2.0 mt is provided and includes mass growth allowances for the MAV, the ERV, and mission unique equipment. We also report on alternate propellant options for the MAV and options for the ERV, including propulsion systems; crewed versus robotic retrieval mission; as well as direct Earth entry. International Planetary Protection Policies as well as verifiable means of compliance will have a large impact on any MSR mission design. We identify areas within our architecture where such impacts occur. This work shows that emerging commercial capabilities can be used to effectively integrated into a mission to achieve an important planetary science objective.

Mars Sample Return↗

FE Simulation of SMA Seal for Mars Sample Return

Several NASA rovers and landers have been on Mars and performed successful in-situ exploration. Returning Martian samples to Earth for extensive analysis is of great interest to the planetary science community. Current Mars sample return architecture would require leaving the acquired samples on Mars for years before being retrieved by subsequent mission. Each sample would be sealed securely to keep its integrity. A reliable seal technique that does not affect the integrity of the samples and uses a simple low-mass tool is required. The shape memory alloy (SMA) seal technique is a promising candidate. A study of the thermal performances of several primary designs of a SMA seal for sample tubes by finite element (FE) simulation are presented in this paper. The results show sealing the sample tube by SMA plugs and controlling the sample temperature below the allowed temperature level are feasible.

seal↗

Achieving Accuracy Requirements for Forest Biomass Mapping: A Spaceborne Data Fusion Method for Estimating Forest Biomass and Lidar Sampling Error

The synergistic use of active and passive remote sensing (i.e., data fusion) demonstrates the ability of spaceborne light detection and ranging (LiDAR), synthetic aperture radar (SAR) and multispectral imagery for achieving the accuracy requirements of a global forest biomass mapping mission (+/-20 Mg/ha or 20%, the greater of the two, for at least 80% of grid cells). A data fusion approach also provides a means to extend 3D information from discrete spaceborne LiDAR measurements of forest structure across scales much larger than that of the LiDAR footprint. For estimating biomass, these measurements mix a number of errors including those associated with LiDAR footprint sampling over regional-global extents. A general framework for mapping above ground live forest biomass density (AGB) with a data fusion approach is presented and verified using data from NASA field campaigns near Howland, ME, USA, to assess AGB and LiDAR sampling errors across a regionally representative landscape. We combined SAR and Landsat-derived optical (passive optical) image data to identify contiguous areas (>0.5 ha) that are relatively homogenous in remote sensing metrics (forest patches). We used this image-derived data with simulated spaceborne LiDAR derived from orbit and cloud cover simulations and airborne data from NASA's Laser Vegetation Imaging Sensor (LVIS) to compute AGB and estimate LiDAR sampling error for forest patches and 100 m, 250 m, 500 m, and 1 km grid cells. At both the patch and grid scales, we evaluated differences in AGB estimation and sampling error from the combined use of LiDAR with both SAR and passive optical and with either SAR or passive optical alone. First, this data fusion approach demonstrates that incorporating forest patches into the AGB mapping framework can provide sub-grid forest information for coarser grid-level AGB reporting. Second, a data fusion approach for estimating AGB using simulated spaceborne LiDAR with SAR and passive optical image combinations reduced forest AGB sampling errors 12%-38% from those where LiDAR is used with SAR or passive optical alone. In absolute terms, sampling errors were reduced from 14-40 Mg/ha to 11-28 Mg/ha across all grid scales and prediction methods, where minimum sampling errors were 11, 15, 18, and 22 Mg/ha for 1 km, 500 m, 250 m, and 100 m grid scales, respectively. Third, spaceborne global scale accuracy requirements were achieved whereby at least 80% of the grid cells at 100 m, 250 m, 500 m, and 1 km grid levels met AGB accuracy requirements using a combination of passive optical and SAR along with machine learning methods to predict vegetation structure metrics for forested areas without LiDAR samples. Finally, using either passive optical or SAR, accuracy requirements were met at the 500 m and 250 m grid level, respectively..

LiDAR↗

Active and Passive Storage Solutions for Low Temperature Lunar Sample Return

Active and passive thermal storage solutions to return lunar biological, physical science and/or geology samples to the Earth are under development. Temperature requirements for biological/physical science sample conditioning range from -100˚C to -153˚C and possibly down to -253˚C for geological samples. The lower limit for geological samples is derived from the temperature of permanently shadowed regions on the lunar surface and the sublimation temperature of specific volatiles of interest (i.e., H2O, NH3 and CH4). Individual samples for the lunar application are expected to be less than 50 kg with a 700 kg allowance for the container and refrigeration. Requiring no electrical power or heat rejection, passive approaches, comprised of high performance insulation and consumable Joule-Thompson cooling, may be preferred for shorter duration missions (< 30 days) to provide significant mass savings. Active storage approaches with cryogenic cooling may be necessary to preserve samples for longer periods of time. A notional passive storage concept with an internal vapor cooled shield is shown below. The vapor cooled shield contains the sample and is isolated from the outer container with concentric reflective rigid shields and conventional multi-layer and/or aerogel insulation on the outer layer. A special removable, insulating end cap to stow or retrieve the sample is included.

Lunar Sample Return↗

The Planetary Protection Strategy of Mars Sample Return’s Earth Return Orbiter Mission

The Mars Sample Return campaign aims to use three flight missions and one ground element to safely bring rock cores, regolith and atmospheric samples from the surface of Mars to Earth to answer key questions about the geologic and climate history of Mars, including the potential for ancient life. Since its landing in Jezero Crater in 2021, the first mission, NASA’s Mars 2020, has collected a number of samples on the crater floor and on the delta using the Perseverance rover. Subsequent missions would recover the sealed sample tubes, launch them into Mars orbit, and transport them back to Earth. The ground element would be a high-containment facility that would isolate and protect the samples during initial sample characterization, which would include sample safety assessments and time-sensitive scientific investigations. These elements are currently in the planning and design stages of development, and represent an international effort of NASA, the European Space Agency (ESA), and many industry partners. The work presented here provides an overview of the planetary protection strategy of the third flight mission, the ESA-led Earth Return Orbiter (ERO), which hosts the NASA-provided Capture, Containment, and Return System (CCRS). ERO-CCRS would capture the container with up to 30 sealed tubes previously put in Martian orbit, contain them in redundant containers to ensure that no potentially hazardous Mars particles are released, and return them to Earth through an entry vehicle. Both NASA and ESA policies comply with the United Nations’ Outer Space Treaty by planning to protect Earth’s biosphere from any potential adverse effects from material returned from solar system bodies beyond the Earth-Moon system. In the conduct of Mars Sample Return, the two agencies have agreed to apply approaches consistent with their own planetary protection standards to the campaign elements each provides.

Mars Sample Return↗