Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SYSTEM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Developments to the Distributed Holdup Monitoring System in Fiscal Year 2025

Permanently installed holdup monitoring would provide a myriad of benefits to nuclear facilities, ranging among decreased facility burden, increased safety bases, and increased accuracy of relevant material controls and accountancy metrics. However, the cost per detection system must be affordable to provide reliable coverage. For this project, the target unit price per system has been $\$$1,000. Recent work has focused on pushing costs lower through developing a plastic scintillator and silicon photomultiplier (SiPM)–based front end, which are components that are not commercially available in conjunction with each other. Other work has included further system development and use of a low-cost SiPM. Finally, a limited deployment at a processing facility was achieved. Results from this deployment and the development process are discussed in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and evaluation of a helicopter-borne water-quality monitoring system

A small, helicopter-borne water-quality monitoring package is being developed by the NASA/EPA using a combination of basic in situ water quality sensors and physical sample collector technology. The package is a lightweight system which can be carried and operated by one person as a passenger in a small helicopter typically available by rental at commercial airports. Real-time measurements are made by suspending the water quality monitoring package with a cable from the hovering helicopter. Designed primarily for use in rapidly assessing hazardous material spills in inland and coastal zone water bodies, the system can survey as many as 20 data stations up to 1.5 kilometers apart in 1 hour. The system provides several channels of sensor data and allows for the addition of future sensors. The system will also collect samples from selected sites with sample collection on command. An EPA Spill Response Team member can easily transport, deploy, and operate the water quality monitoring package to determine the distribution, movement, and concentration of the spilled material in the water body.

Wallace, J. W.↗

Automatic vehicle monitoring systems study. Report of phase O. Volume 1: Executive summary

A set of planning guidelines is presented to help law enforcement agencies and vehicle fleet operators decide which automatic vehicle monitoring (AVM) system could best meet their performance requirements. Improvements in emergency response times and resultant cost benefits obtainable with various operational and planned AVM systems may be synthesized and simulated by means of special computer programs for model city parameters applicable to small, medium, and large urban areas. Design characteristics of various AVM systems and the implementation requirements are illustrated and cost estimated for the vehicles, the fixed sites, and the base equipments. Vehicle location accuracies for different RF links and polling intervals are analyzed.

Source record↗

A MODIS-Based Automated Flood Monitoring System for Southeast Asia

Flood disasters in Southeast Asia result in significant loss of life and economic damage. Remote sensing information systems designed to spatially and temporally monitor floods can help governments and international agencies formulate effective disaster response strategies during a flood and ultimately alleviate impacts to population, infrastructure, and agriculture. Recent destructive flood events in the Lower Mekong River Basin occurred in 2000, 2011, 16 2013, and 2016 (http://ffw.mrcmekong.org/historical_rec.htm, April 24, 2017). The large spatial distribution of flooded areas and lack of proper gauge data in the region makes accurate monitoring and assessment of impacts of floods difficult. Here, we discuss the utility of applying satellite-based Earth observations for improving flood inundation monitoring over the flood-prone Lower Mekong River Basin. We present a methodology for determining near real-time surface water extent associated with current and historic flood events by training surface water classifiers from 8-day, 250-meter Moderate-resolution Imaging Spectroradiometer (MODIS) data spanning the length of the MODIS satellite record. The Normalized Difference Vegetation Index (NDVI) signature of permanent water bodies (MOD44W; Carroll et al., 2009) is used to train surface water classifiers which are applied to a time period of interest. From this, an operational nowcast flood detection component is produced using twice daily imagery acquired at 3-hour latency which performs image compositing routines to minimize cloud cover. Case studies and accuracy assessments against radar-based observations for historic flood events are presented. The customizable system has been transferred to regional organizations and near real-time derived surface water products are made available through a web interface platform. Results highlight the potential of near real-time observation and impact assessment systems to serve as effective decision support tools for governments, international agencies, and disaster responders.

Mekong River↗

Development of a Structural Health Monitoring System for the Life Assessment of Critical Transportation Infrastructure

Recent structural failures such as the I-35W Mississippi River Bridge in Minnesota have underscored the urgent need for improved methods and procedures for evaluating our aging transportation infrastructure. This research seeks to develop a basis for a Structural Health Monitoring (SHM) system to provide quantitative information related to the structural integrity of metallic structures to make appropriate management decisions and ensuring public safety. This research employs advanced structural analysis and nondestructive testing (NDT) methods for an accurate fatigue analysis. Metal railroad bridges in New Mexico will be the focus since many of these structures are over 100 years old and classified as fracture-critical. The term fracture-critical indicates that failure of a single component may result in complete collapse of the structure such as the one experienced by the I-35W Bridge. Failure may originate from sources such as loss of section due to corrosion or cracking caused by fatigue loading. Because standard inspection practice is primarily visual, these types of defects can go undetected due to oversight, lack of access to critical areas, or, in riveted members, hidden defects that are beneath fasteners or connection angles. Another issue is that it is difficult to determine the fatigue damage that a structure has experienced and the rate at which damage is accumulating due to uncertain history and load distribution in supporting members. A SHM system has several advantages that can overcome these limitations. SHM allows critical areas of the structure to be monitored more quantitatively under actual loading. The research needed to apply SHM to metallic structures was performed and a case study was carried out to show the potential of SHM-driven fatigue evaluation to assess the condition of critical transportation infrastructure and to guide inspectors to potential problem areas. This project combines the expertise in transportation infrastructure at New Mexico State University with the expertise at Sandia National Laboratories in the emerging field of SHM.

36 MATERIALS SCIENCE↗

Performance Test of the Next Generation X-Ray Beam Position Monitor System for The APS Upgrade

The Advanced Photon Source is developing its next major upgrade (APS-U) based on the multi-bend achromat lattice. Improved beam stability is critical for the upgrade and will require keeping short-time beam angle change below 0.25 µrad and long-term angle drift below 0.6 µrad. A reliable white x-ray beam diagnostic system in the front end will be a key part of the planned beam stabilization system. This system includes an x-ray beam position monitor (XBPM) based on x-ray fluorescence (XRF) from two specially designed GlidCop A-15 absorbers, a second XBPM using XRF photons from the Exit Mask, and two white beam intensity monitors using XRF from the photon shutter and Compton-scattered photons from the front end beryllium window or a retractable diamond film in windowless front ends. We present orbit stability data for the first XBPM used in the feedback control during user operations, as well as test data from the second XBPM and the intensity monitors. They demonstrate that the XBPM system meets APS-U beam stability requirements.

Yang, B.↗

Development of a contact lens quality monitoring system

The quality of contact lens samples depends strongly on their free volume fractions. It is expected that the free volume fraction of the test samples will also impact their attenuation coefficients for soft x rays. Samples with larger free volume fractions should have lower linear attenuation coefficients. Linear attenuation coefficients for Cd-109/Ag-109 x rays have been measured in five contact lens samples. It has been shown that the difference in the linear attenuation coefficients of discs from any given sample are entirely due to the difference in their respective volume fractions. It is therefore concluded that an x ray attenuation measurement system can serve as a quality monitor for contact lens polymers.

Singh, Jag J.↗

Modeling of Global BEAM Structure for Evaluation of MMOD Impacts to Support Development of a Health Monitoring System

This report summarizes the initial modeling of the global response of the Bigelow Expandable Activity Module (BEAM) to micrometeorite and orbital debris(MMOD) impacts using a structural, nonlinear, transient dynamic, finite element code. These models complement the on-orbit deployment of the Distributed Impact Detection System (DIDS) to support structural health monitoring studies. Two global models were developed. The first focused exclusively on impacts on the soft-goods (fabric-envelop) portion of BEAM. The second incorporates the bulkhead to support understanding of bulkhead impacts. These models were exercised for random impact locations and responses monitored at the on-orbit sensor locations. The report concludes with areas for future study.

Lyle, Karen H.↗

Loss Control and Monitoring Systems for NSLS-Ii

The tunnel shielding design for the NSLS-II will provide adequate protection for beam losses up to 13nC/min or 100% of the maximum top-off injection beam current to be lost in the two periods of the ring around the injection point, while the remainder of the ring is shielded for lower losses of 1.1nC/min or ≤10% of the maximum top-off injected beam current. Additional local shielding of potential loss points in the injection region (e.g. injection septum) will be used to increase the level of loss allowed at these location during 1 Hz injection (i.e. nonTop-off injection). This shielding design will require a system to insure that beam losses don’t exceed these levels for a period of time that could potentially cause levels of radiation outside the shield walls to exceed administrative levels. This Loss Control and Monitoring (LCM) system will provide a level of loss control, loss location measurements and provide alarm indication of the level of beam power losses along the beam path from the source (e-gun, linac) thru the injection system and the storage ring. This system will consist of collimators and scrapers that will provide limits to the beam miss-steering and control the loss points of the charge, and monitors that will measure the average beam current losses along the beam path and alarm when this beam power loss exceeds the level set by the shielding specifications or administrative levels. This will require some new ideas in beam loss detection capability and collimation. The system is not intended to trip interlocks (dumping beam or terminating injection) but only to alarm that higher than normal beam power losses are observed and report where it is occurring. If the alarms conditions are not corrected within a time limit, top-off injection could be slowed down, thereby reducing the beam loss and the radiation it may be producing.

36 MATERIALS SCIENCE↗

LibPowerMon: A vendor-neutral system monitoring library

As power becomes an important resource to provision for modern HPC systems it becomes crucial to obtain deeper insights into application's power and thermal characteristics and to correlate application context with important system-level measurements. Existing profiling tools to monitor power and thermal measurements either operate at a granularity that is not fine enough to correlate with application-level events that describe application context or are not equipped to sample application-level events transparently. We introduce LibPowerMon, a lightweight, vendor-neutral user-level profiling framework to simultaneously sample user-specified application events and system-level metrics at up to 1 kHz sampling intervals. At the application level, LibPowerMon provides a source-level phase markup interface to capture application context. At runtime level, LibPowerMon records MPI and OpenMP events and can be extended to include other runtimes. At the system level, LibPowerMon samples power, thermal and relevant metrics, and provides an extensible interface to system's control capabilities. In this release, LibPowerMon supports monitoring and control functionalities on the Intel, IBM Power9 and Nvidia Volta architectures.

MARATHE, ANIRUDDHAP↗

Cyber‐physical system testbed for power system monitoring and wide‐area control verification

The electric power system is intrinsically a cyber‐physical system (CPS) with power flowing inthe physical system and information flowing in the cyber‐network. Testbeds arecrucial for understanding the cyber‐physical interactions and provideenvironments for prototyping novel applications. This study proposes afour‐layer architecture for CPS testbeds with emphases on communication networkemulation and networked physical components. A configurable software‐definednetwork is employed to bridge physical components with wide‐area applicationsfor closed‐loop control. In order to distribute physically coupled devices intomultiple software simulations, this study proposes a data broker setup based ona distributed messaging environment to achieve low‐latency data streaming. Thedecoupled design with data streaming allows for building testbed components asmodules and running them in a distributed manner. Case studies verify the databroker setup for low‐latency sensing and actuation, as well as the communicationemulation setup for the desired network latency. Also illustrated is a replayattack scenario using synchrophasors in the Western Electricity CoordinatingCouncil (WECC) 181‐bus system for demonstrating the closed‐loop cyber‐physicalsimulation capability of the testbed.

Cui, Hantao↗

A knowledge based expert system for propellant system monitoring at the Kennedy Space Center

The Lox Expert System (LES) is the first attempt to build a realtime expert system capable of simulating the thought processes of NASA system engineers, with regard to fluids systems analysis and troubleshooting. An overview of the hardware and software describes the techniques used, and possible applications to other process control systems. LES is now in the advanced development stage, with a full implementation planned for late 1985.

Jamieson, J. R.↗

Total Ozone from the Ozone Monitoring System (OMI) using TOMS and DOAS Methods

The Ozone Monitoring Instrument (OMI) is the Dutch-Finnish contribution to NASA's EOS-Aura satellite scheduled for launch in January 2004. OMI is an imaging spectrometer that will measure the back-scattered Solar radiance in the wavelength range of 270 to 500 nm. The instrument provides near global coverage in one day with a spatial resolution of 13x24 square kilometers. OMI is a new instrument, with a heritage from TOMS, SBW, GOME, GOMOS and SCIAMACHY. OMI'S unique capabilities for measuring important trace gases and aerosols with a small footprint and daily global coverage, in conjunction with the other Aura instruments, will make a major contribution to our understanding of stratospheric and tropospheric chemistry and climate change. OMI will provide data continuity with the 23-year ozone record of TOMS. There are three ozone products planned for OMI: total column ozone, ozone profile and tropospheric column ozone. We are developing two different algorithms for total column ozone: one similar to the algorithm currently being used to process the TOMS data, and the other an improved version of the differential optical absorption spectroscopy (DOAS) method, which has been applied to GOME and SCIAMACHY data. The main reasons for starting with two algorithms for total ozone have to do with heritage and past experience; our long-term goal is to combine the two to develop a more accurate and reliable total ozone product for OMI. We will compare the performance of these two algorithms by applying both of them to the GOME data. We will examine where and how the results differ, and use the extensive TOMS-Dobson comparison studies to assess the performance of the DOAS algorithm.

Veefkind, J. P.↗

Methods, apparatus, and systems for monitoring transmission systems

A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.

Polk, Robert E↗

Methods, apparatus, and systems for monitoring transmission systems

A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.

42 ENGINEERING↗

Methods, apparatus, and systems for monitoring transmission systems

A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.

24 POWER TRANSMISSION AND DISTRIBUTION↗