At least 469 records · Page 26

Groundwater flowpath characteristics drive variability in per- and polyfluoroalkyl substances (PFAS) loading across a stream-wetland system

Groundwater dependent ecosystems in areas with industrial and military land use are at risk of direct exposure to a wide range of contaminants, including PFAS chemicals. Glaciated terrain often has mixed high and low permeability sediments coupled with groundwater flow-through lake features. These hydrogeologic attributes create highly complex ‘source to seep’ dynamics that make spatiotemporal contaminant transport patterns difficult to predict. We investigated one such system in detail using a suite of heat-tracing and chemical methods. Numerous (n=57) preferential groundwater discharge zones (vertical flux rates ranging 0.2 to 3.2 m/d) were identified across the upper Quashnet River stream-wetland system in Mashpee, MA, USA, adjacent to an Air Force Base with several known PFAS source areas. Surface-water and groundwater samples were collected and analyzed (n=145) for precursors and terminal PFAS compounds between March and September 2022. Samples were collected at identified seeps along the Quashnet River (n=59), from wells upgradient from the stream-wetland system (n= 44), from contributing flow-through kettle lakes (n=8), and at multiple locations along the Quashnet River (n=34). Samples from seeps and wells had measured PFAS concentrations ranging from non-detect to approximate 3,500 ng/L (mean= 1,650 ng/L), and a range of deuterium excess values (3.2 to 15.9 per mil) indicative of varying degrees of groundwater-lake interaction prior to emergence at the discharge zones. Groundwater-lake interaction along flowpaths that sourced the sampled seeps was farther supported by significant correlations (p < 0.01) between deuterium excess and %PFAS precursors, and between %PFAS precursors and multiple terminal PFAS compounds (e.g., PFPeS, PFBS, PFHxS). However, some sampled seeps contributing groundwater to the stream-wetland system had much higher total PFAS concentrations (>1000 ng/L) than the upgradient kettle lakes, despite showing lake (evaporative) isotopic signatures, indicating the potential for groundwater flowpath convergence at wetland discharge zones and the influence of lakebed PFAS precursor reactions. PFAS compounds and water isotopic composition at sampled multilevel groundwater wells, rivers, lakes, and seeps suggest that a complex mixture of source groundwater and flowpath characteristics are responsible for diverse observed PFAS mixtures at preferential discharge zones across the stream-wetland system. Further, total PFAS loading patterns to the Quashnet River via groundwater discharge remained remarkably similar from winter to summer to fall conditions, despite a regional dry period in late summer 2022 with the upper river channel completely drying. This work addresses gaps in the existing PFAS literature by demonstrating the importance of subsurface fate and transport on PFAS compound concentrations in controlling contaminant mass loading in preferential groundwater discharge zones and presents a transferrable field toolkit for efficient characterization of spatially preferential PFAS transport dynamics.

Contaminant transport↗

Utilization of Ultrasonication as a Method of Reducing Organic and Inorganic Contamination in Post‐Consumer Plastic Film Waste

Post-consumer plastic film waste often carries organic and inorganic contaminants that challenge recycling processes and affect the quality of recycled products. An effective contaminant removal procedure through washing such single-used plastic films (SUPFs) can address environmental and waste management concerns. This study compares the efficiency of different washing techniques in reducing SUPF contamination. To evaluate the efficacy of each washing technique, film samples collected from material recovery facilities are individually exposed to friction, ultrasonic-assisted, and a combination of both washes. Thermal analysis indicates that the polymers' melting temperature, crystallization temperature, and crystallinity remain unaffected by the washing methods, demonstrating method aptness. Confocal laser scanning microscope images show that washing results in a cleaner sample surface. 91% ash reduction during the combined wash treatment indicates a high method efficiency compared to the individual friction and ultrasonic wash procedures. This is further validated by reducing characteristic contaminant IR bands (3600–3000, 1750–1600, and 1100–1000 cm −1 ). Elements of concern such as Cd, Cr, Hg, and Pb in SUPFs after each washing technique applied conform with regulations (<100 ppm) for packaging products. This research shows the novel ultrasonic washing reduces more contamination than friction with shorter wash times and no surfactants.

42 ENGINEERING↗

Evaluating Exposures of Bay Mussels (Mytilus trossulus) to Contaminants of Emerging Concern through Environmental Sampling and Hydrodynamic Modeling.

Bay mussels (Mytilus trossulus) were transplanted to 18 locations representing a range of potential exposures throughout Puget Sound, WA. Tissues were analyzed for over 200 organic contaminants. Results indicated the widespread exposure of marine organisms to trace levels of organic contaminants including the synthetic opioid oxycodone, present at three urban sites, and the chemotherapy drug melphalan, present at nine locations, at levels that may be of biological concern. Land-use and wastewater outfalls were evaluated as potential sources of CECs to the nearshore. Exposure to alkylphenol ethoxylates was associated with increased impervious surfaces in upland watersheds. A hydrodynamic simulation was performed using the Salish Sea Model to integrate inputs from 99 wastewater sources to Puget Sound. Predictions were consistent with concentrations of several wastewater-associated contaminants and d15N enrichment. These results support the notion that Puget Sound nearshore biota suffer chronic exposures to a suite of contaminants from multiple sources and provide critical to focus future monitoring and management.

toxic contamination, Salish Sea, Sish Sea Model, m↗

Model Package Report: Geoframework Model of the Hanford Site 100 Area

The purpose of the 100 Area Geoframework Model (GFM) is to provide a reasonable, consistent, and defensible three dimensional representation of the hydrostratigraphic units below the River Corridor at the Hanford Site to support contaminant fate and transport models. The GFM is a three dimensional representation of the subsurface geologic structure. From this, three dimensional geologic model-exported results, in the form of points or surfaces, are used as inputs to populate and assemble the various numerical model architectures. The objective of this report is to define the process used to produce a hydrostratigraphic model for the hydrostratigraphic units beneath the Hanford Site 100 Area. The GFM may support several other CH2M HILL Plateau Remediation Company project needs and objectives, including providing geologic information to support remedial investigations and actions and as a tool to present River Corridor geology and contaminant extents. The GFM was constructed based on information through 2019 available in the Integrated Data Management System, Hanford Environmental Information System, and the Hanford Site geologic contacts (GeoContacts) datasets. Revisions to the 100 Area GFM may occur to incorporate new data and information. Each version will be maintained in configuration control using date stamps for identifying supporting databases, figures, and interpretations. Supporting data include the final three dimensional geoframework surfaces, two dimensional structure and isopach maps, and all the geologic contact inputs and interpreted geologic log data. These final products provide a supporting set of geologic information that together allow the creation of the GFM. This information is managed, updated, and maintained via CH2M HILL Plateau Remediation Company under the Environmental Model Management Archive.

58 GEOSCIENCES↗

Plasma Facing Component Characterization and Correlation With Plasma Conditions in Lithium Tokamak Experiment-β

Lithium coatings in the Lithium Tokamak eXperiment (LTX) led to flat temperature profiles. The flat temperature profiles were observed along with a hot, low density edge, implying a broad, collisionless scrape-off layer (SOL). Additionally, in vacuo X-ray photoelectron spectroscopy (XPS) measurements established that lithium coatings evaporatively deposited onto high-Z plasma facing components (PFCs) became oxidized while retaining the ability to achieve good plasma performance long after lithium was applied to the PFCs. Longstanding theory predicted flat temperature profiles with low recycling walls, which was presumed to be due to hydrogen binding with elemental lithium to form lithium hydride. The presence of oxidized lithium, however, raised questions regarding the exact mechanism of hydrogen retention in LTX. To investigate these questions, the upgraded facility LTX- β includes a new sample exposure probe (SEP) for more detailed in vacuo analysis of PFC samples. The SEP is equipped with a vacuum suitcase capable of transporting samples representative of the LTX- β outer midplane PFCs to a stand-alone XPS system while maintaining pressures lower than the LTX- β base vacuum to limit the contamination between sample exposure and analysis. The low-energy resolution XPS system used in past experiments could only enable the determination of elemental percentages on the PFC sample surfaces. Because the new XPS system has higher energy resolution, it is more direct to assign chemical compounds to the measured binding energies. This capability has been confirmed by comparing XPS data from PFC test samples with measurements using a commercial high-resolution XPS system. Quartz crystal microbalances (QCMs) were used to quantify the thickness of the deposited lithium on the LTX- β PFCs. This article describes the application of the SEP to characterize the PFC surfaces using XPS and their relationship to plasma conditions.

Maan, Anurag↗

Alpha Spectrometry Results for Groundwater Samples Collected in Northern Iraq and a Summary of the Environmental Setting of the Adaya Burial Site

The Radiation Protection Center (RPC) of the Iraqi Ministry of Environment continues to evaluate the potential health impacts associated with the Adaya Burial Site, which is located 33 kilometers (20.5 miles) southwest of Mosul. This report documents the radiological analyses of 16 groundwater samples collected from wells located in the vicinity of the Adaya Burial Site and at other sites in northern Iraq. The Adaya Burial Site is a high-risk dump site because a large volume of radioactive material and contaminated soil is located on an unsecure hillside above the village of Tall ar Ragrag. The uranium activities for the 16 water samples in northern Iraq are considered to be naturally occurring and do not indicate artificial (man-made) contamination. With one exception, the alpha spectrometry results for the 16 wells that were sampled in 2019 indicate that the water quality concerning the three uranium isotopes (Uranium-233/234, Uranium-235/236, and Uranium-238) was acceptable for potable purposes (drinking and cooking). However, Well 7 in Mosul had a Uranium-233/234 activity concentration that slightly exceeded the World Health Organization guidance level. Eight of the 16 wells are located in the villages of Tall ar Ragrag and Adaya and had naturally occurring uranium concentrations. Wells in the villages of Tall ar Ragrag and Adaya are located near the Adaya Burial Site and should be sampled on an annual schedule. The list of groundwater analytes should include metals, total uranium, isotopic uranium, gross alpha/beta, gamma spectroscopy, organic compounds, and standard water quality parameters. Our current understanding of the hydrogeologic setting in the vicinity of the Adaya Burial Site is solely based on villager's domestic wells, topographic maps, and satellite imagery. To better understand the hydrogeologic setting, a Groundwater Monitoring Program needs to be developed and should include the installation of twelve groundwater monitoring wells in the vicinity of Tall ar Ragrag and the Adaya Burial Site. Characterization of the limestone aquifer and overlying alluvium is needed. RPC should continue to support health assessments for the villagers in Tall ar Ragrag and Adaya. Collecting samples for surface water (storm water), airborne dust, vegetation, and washway sediment should be conducted on a routine basis. Human access to the Adaya Burial Site needs to be strictly limited. Livestock access on or near the burial site needs to be eliminated. The surface-water exposure pathway is likely a greater threat than the groundwater exposure pathway. Installation of a surface-water diversion or collection system is recommended in order to reduce the potential for humans and livestock to come in contact with contaminated water and sediment. To reduce exposure to villagers, groundwater treatment should be considered if elevated uranium or other contaminants are detected in drinking water. Installing water-treatment systems would likely be quicker to accomplish than remediation and excavation of the Adaya Burial Site. The known potential for human exposure to uranium and metals (such as arsenic, chromium, selenium, and strontium) at the Adaya Burial Site is serious. Additional characterization , mitigation, and remediation efforts should be given a high priority.

54 ENVIRONMENTAL SCIENCES↗

Optimized purification methods for metallic contaminant removal from directly recycled Li-ion battery cathodes

Metallic contaminants pose a significant challenge to the viability of directly recycling Li-ion batteries. To date, few strategies exist to selectively remove metallic impurities from mixtures of shredded end-of-life material (black mass; BM) without concurrently damaging the structure and electrochemical performance of the target active material. We herein present tailored methods to selectively ionize two major contaminants—Al and Cu—while retaining a representative cathode (LiNi 0.33 Mn 0.33 Co 0.33 O 2 ; NMC-111) intact. This BM purification process is conducted at moderate temperatures in a KOH-based solution matrix. We rationally evaluate approaches to increase both the kinetic corrosion rate and the thermodynamic solubility of Al 0 and Cu 0 , and evaluate the impact of these treatment conditions on the structure, chemistry, and electrochemical performance of NMC. Specifically, we explore the impacts of chloride-based salts, a strong chelating agent, elevated temperature, and sonication on the rate and extent of contaminant corrosion, while concurrently evaluating the effects on NMC. The reported BM purification process is then demonstrated on samples of “simulated BM” containing a practically relevant 1 wt% concentration of Al or Cu. Increasing the kinetic energy of the purifying solution matrix through elevated temperature and sonication accelerates the corrosion of metallic Al and Cu, such that ∼100% corrosion of 75 μm Al and Cu particles is achieved within 2.5 hr. Further, we determine that effective mass transport of ionized species critically impacts the efficacy of Cu corrosion, and that saturated Cl – hinders rather than accelerates Cu corrosion by increasing solution viscosity and introducing competitive pathways for Cu surface passivation. The purification conditions do not induce bulk structural damage to NMC, and electrochemical capacity is maintained in half-cell format. Testing in full cells suggests that a limited quantity of residual surface species are present after treatment, which initially disrupt electrochemical behavior at the graphite anode but are subsequently consumed. Process demonstration on simulated BM suggests that contaminated samples—which prior to treatment show catastrophic electrochemical performance—can be recovered to pristine electrochemical capacity. The reported BM purification method offers a compelling and commercially viable solution to address contamination, particularly in the “fine” fraction of BM where contaminant sizes are on the same order of magnitude as NMC and where traditional separation approaches are unfeasible. Thus, this optimized BM purification technique offers a pathway towards viable direct recycling of BM feedstocks that would otherwise be unusable.

25 ENERGY STORAGE↗

The effect of gas injection location on a lithium vapor box divertor in NSTX-U

Abstract The lithium vapor box divertor is a proposed divertor design that will minimize contamination of the upstream plasma in a fusion device, while also ensuring protection of the target. In this design lithium is evaporated near the target by high temperature lithium surfaces, dissipating the plasma heat flux. The lithium vapor box has been predicted via the fluid-kinetic code scrape off layer plasma simulator (SOLPS-ITER) to achieve low ( n L i / n e ∼ 0.05) upstream concentrations of lithium and low target heat fluxes. Here we compare two choices of deuterium gas puff location using SOLPS-ITER, the private flux region (PFR) and the common flux region (CFR), and find significant differences in the contamination level required to reach an acceptable target heat flux (defined here as q tar max ⩽ 10 MW m −2 ). Deuterium gas puffing from the PFR is seen to better reduce upstream lithium contamination. The difference in puffing location is seen to cause changes in the upstream flow of lithium ions. The PFR puff, having better access to the separatrix, can better reduce the upstream-directed flow of lithium near the separatrix which is the primary source of contamination due to a large thermal force in this region. Puffing from the CFR, partially due to inefficacy at reducing separatrix lithium flow, has higher lithium concentration within the plasma. Solutions that reduce the heat flux to below 10 MW m −2 have a range of lithium concentrations between n L i / n e ∼ 0.01–0.12 depending on puff intensity, location, evaporator temperature and recycling at the various plasma facing components. The efficacy of the puffs is tested for sensitivity to deuterium recycling coefficient at the target, evaporators, and main chamber walls. A CFR located puff is found to be more dependent on the recycling coefficients used than a PFR located puff. regardless of the set of recycling coefficients chosen, PFR puffing achieves lower lithium contamination than CFR puffing for a given heat flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Analysis Insight Note: Observations relating to photoemission peak shapes, oxidation state, and chemistry of titanium oxide films

It is common practice to describe the coordination of metal atoms in a binding configuration with their nearest neighbors in terms of oxidation state, a measure by which the number of electrons redistributed between atoms forming chemical bonds. In XPS terms, change to an oxidation state is commonly inferred by correlating photoemission signal with binding energy. The assumption, when classifying photoemission signals into distinct spectral shapes, is that a distribution of intensities shifted to lower binding energy is evidence of a reduction in oxidation state. In this Insight note, we raise the prospect that changes in photoemission peak shape may occur without obvious changes, determined by XPS in stoichiometry for a material. It is well known that TiO 2 measured by XPS yields reproducible Ti 2p photoemission peaks. However, on exposing TiO 2 to ion beams, Ti 2p photoemission evolves to complex distributions in intensity, which are particularly difficult to analyze by traditional fitting of bell-shaped curves to these data. For these reasons, in this Insight note, a thin film of TiO 2 deposited on a silicon substrate is chosen for analysis by XPS and linear algebraic techniques. Alterations in spectral shapes created from modified TiO 2 , which might be interpreted as the change in oxidation state, are assessed in terms of relative proportions of titanium to oxygen. It is found through detailed analysis of spectra that quantification by XPS, using procedures routinely used in practice, is not in accord with the typical interpretations of photoemission shapes. The data processing methods used and results presented in this work are of particular relevance to elucidating fundamental phenomena governing the surface evolution of materials-enabled energy processes where cyclic/non-steady usage changes the nature of bonding, especially in the presence of contaminants.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Materials for Energy-Water Systems: The Central Role of Water/Solid Interfaces in Adsorption, Reactivity, and Transport

The structure, chemistry, and charge of interfaces between materials and aqueous fluids play a central role in determining properties and performance of numerous water systems. Sensors, membranes, sorbents, and heterogeneous catalysts almost uniformly rely on specific interactions between their surfaces and components dissolved or suspended in the water-and often the water molecules themselves-to detect and mitigate contaminants. Deleterious processes in these systems such as fouling, scaling (inorganic deposits), and corrosion are also governed by interfacial phenomena. Despite the importance of these interfaces, much remains to be learned about their multiscale interactions. Developing a deeper understanding of the molecular- and mesoscale phenomena at water/solid interfaces will be essential to driving innovation to address grand challenges in supplying sufficient fit-for-purpose water in the future. In this Review, we examine the current state of knowledge surrounding adsorption, reactivity, and transport in several key classes of water/solid interfaces, drawing on a synergistic combination of theory, simulation, and experiments, and finally, provide an outlook for prioritizing strategic research directions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Attenuation of Uranium in the Subsurface

Over time, the focus for the Hanford Site has moved from production to decommissioning and site remediation. Several hundred metric tons of near-surface vadose zone sediment have been excavated from the 300 Area in an effort to remove the source of the uranium contamination (DOE/RL, 2011). Despite remediation efforts, uranium continues to be problematic with concentrations greater than the maximum contaminant level (MCL, which is 30 µg/L) for drinking water. Due to the close proximity of the Columbia River, the uranium continues to be a focus of investigation and remediation. After finding that the uranium concentrations were not decreasing as quickly as expected (based on the 1996 ROD) the Tri-Parties set new milestones, including an update of the conceptual model for the 300 Area uranium plume (Williams et al., 2007). In order to more accurately complete a feasibility study and identify how to remediate the uranium in the groundwater, the DOE authorized a remedial investigation/feasibility study (RI/FS). RI/FSs are designed to screen technologies to determine effectiveness, implementability, and cost (see Chapter 2b). These studies are designed to be conducted concurrently as part of the CERCLA process, so the data collected during site characterization (part of the RI) can inform the treatability studies and field tests conducted under the FS (EPA 1988). For the 300 Area, this study included laboratory, field, and modeling components as well as additional sediment and groundwater characterization to determine a suitable remediation strategy to reduce the uranium concentration in the groundwater plume within the expected time frame and cost.

300 area, uranium, polyphosphate, Hanford book pro↗

Microscale Electrochemical Corrosion of Uranium Oxide Particles

Understanding the corrosion of spent nuclear fuel is important for the development of long-term storage solutions. However, the risk of radiation contamination presents challenges for experimental analysis. Adapted from the system for analysis at the liquid–vacuum interface (SALVI), we developed a miniaturized uranium oxide (UO 2 )-attached working electrode (WE) to reduce contamination risk. To protect UO 2 particles in a miniatured electrochemical cell, a thin layer of Nafion was formed on the surface. Atomic force microscopy (AFM) shows a dense layer of UO 2 particles and indicates their participation in electrochemical reactions. Particles remain intact on the electrode surface with slight redistribution. X-ray photoelectron spectroscopy (XPS) reveals a difference in the distribution of U(IV), U(V), and U(VI) between pristine and corroded UO 2 electrodes. The presence of U(V)/U(VI) on the corroded electrode surface demonstrates that electrochemically driven UO 2 oxidation can be studied using these cells. Our observations of U(V) in the micro-electrode due to the selective semi-permeability of Nafion suggest that interfacial water plays a key role, potentially simulating a water-lean scenario in fuel storage conditions. This novel approach offers analytical reproducibility, design flexibility, a small footprint, and a low irradiation dose, while separating the α-effect. This approach provides a valuable microscale electrochemical platform for spent fuel corrosion studies with minimal radiological materials and the potential for diverse configurations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL Radiological Response Training Range

This assessment uses screening-level models to calculate potential environmental impacts from proposed tests at the Idaho National Laboratory (INL) Radiological Response Training Range (RRTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K2O, LaBr3, KBr, Cu, Zr, F, Ga, Ga2O3, NaNO2, Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program mixing-cell model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated assuming 12 tests are conducted annually using all 11 material types for a period of 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer-code input, output, executable files, batch files, scripts, and spreadsheet files are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS). It is highly unlikely the test scenarios evaluated in this ECAR will adversely impact human health based on comparisons of calculated dose and concentration against regulatory standards and risk-based screening levels. Conservative estimates of dose to workers and the public from atmospheric transport of possible radionuclide releases are far below federal radiation protection standards. Conservative estimates of potential contaminant concentrations in groundwater are less than federal drinking water standards or screening levels. Predicted radionuclide concentrations in surface soils are below risk-based screening levels, except for Ge-68 (material Ga-68) for the worker. The Ge-68 soil concentration can be made less than the worker PRG, if the number of annual tests using Ga-68 is reduced from 12 to 6. However, the sum of ratios still exceeds one because of the high K-40 ratio. If the EF of the worker (number of days the worker is in the contaminated testing area) is reduced from 225 days/yr (default value for full time worker) to 112 days/yr, the Ge-68 ratio is less than one and the sum of ratios is less than one. Actual radiation doses and groundwater and surface-soil concentrations are likely to be much less than those calculated because of the conservative assumptions and parameters employed in the modeling. For example, atmospheric-transport calculations assume the entire inventory of each material type is readily released to the atmosphere and no plume deposition, depletion, or radioactive decay occurs during transport. The calculations also assume the same meteorological conditions (e.g., wind velocity, wind direction, stability class) that produce the maximum 95th percentile concentration (i.e., concentration representing the 95th percentile of a distribution of concentrations derived from 3 years of hourly meteorological data) at each receptor location are the same for all 12 tests during the year, and each receptor is assumed to be present during all 12 tests. The surface-soil assessment assumes the entire inventory of each test is deposited in the top 5 cm of soil. No atmospheric dispersal is assumed, and the radionuclides are subject only to leaching and radioactive decay. The groundwater-pathway modeling is conservative in that it is one-dimensional in the unsaturated zone (no lateral spreading/dilution) and assumes the entire inventory of contaminants infiltrates into the ground at the same location for every test. This is especially conservative for particulate radionuclides because they would have to dissolve or corrode first and some would be dispersed into the atmosphere. The groundwater receptor is also assumed to consume water directly from a hypothetical well positioned in the location of maximum concentration. In addition, conservative degradation rates were used, and volatilization was not considered for the nonradioactive chemical

54 ENVIRONMENTAL SCIENCES↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL National Security Test Range

This assessment uses screening-level models to calculate potential environmental impacts from proposed tests at two locations at the Idaho National Laboratory (INL) National Security Test Range (NSTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K 2 O, LaBr 3 , KBr, Cu, Zr, F, Ga, Ga 2 O 3 , NaNO 2 , Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program mixing-cell model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated based on the assumption that 12 tests are conducted annually using all 11 material types for 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer-code input, output, executable files, batch files, scripts, and spreadsheet files, are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS). It is highly unlikely the test scenarios evaluated in this ECAR will adversely impact human health based on comparisons of calculated dose and concentration against regulatory standards and risk-based screening levels. Conservative estimates of dose to workers and the public from atmospheric transport of possible radionuclide releases are far below federal radiation protection standards. Conservative estimates of potential contaminant concentrations in groundwater are less than federal drinking water standards or screening levels. Predicted radionuclide concentrations in surface soils are below risk-based screening levels, except for Ge-68 (material Ga-68) for the worker. The Ge-68 soil concentration can be made less than the worker PRG, if the number of annual tests using Ga-68 is reduced from 12 to 6. However, the sum of ratios still exceeds one because of the high K-40 ratio. If the EF of the worker (number of days the worker is in the contaminated testing area) is reduced from 225 days/yr (default value for full time worker) to 112 days/yr, the Ge-68 ratio is less than one and the sum of ratios is less than one. Actual radiation doses and groundwater and surface-soil concentrations are likely to be much less than those calculated because of the conservative assumptions and parameters employed in the modeling. For example, atmospheric-transport calculations assume the entire inventory of each material type is readily released to the atmosphere and no plume deposition, depletion, or radioactive decay occurs during transport. The calculations also assume the same meteorological conditions (e.g., wind velocity, wind direction, stability class) that produce the maximum 95th percentile concentration (i.e., concentration representing the 95th percentile of a distribution of concentrations derived from 3 years of hourly meteorological data) at each receptor location are the same for all 12 tests during the year, and each receptor is assumed to be present during all 12 tests. The surface-soil assessment assumes the entire inventory of each test is deposited in the top 5 cm of soil. No atmospheric dispersal is assumed, and the radionuclides are subject only to leaching and radioactive decay. The groundwater-pathway modeling is conservative in that it is one-dimensional in the unsaturated zone (no lateral spreading/dilution) and assumes the entire inventory of contaminants infiltrates into the ground at the same location for every test. This is especially conservative for particulate radionuclides because they would have to dissolve or corrode first and some would be dispersed into the atmosphere. The groundwater receptor is also assumed to consume water directly from a hypothetical well positioned in the location of maximum concentration. In addition, conservative degradation rates were used, and volatilization was not considered for the nonradradioactive chemicals modeled. And finally, the calculations assume all 12 tests will be performed at the same place at both locations, and all 11 radioactive material types will be used for each test. This is conservative because it is anticipated that no more than two material types will be used per test.

99 GENERAL AND MISCELLANEOUS↗

Plant Growth Study: Growth of Three Plant Species in 100-OL-1 Operable Unit Soils

Soil contamination from historical application of lead arsenate pesticides persists in the 100-OL-1 Operable Unit (OU) of the U.S. Department of Energy’s Hanford Site in Benton County, Washington. A remedial investigation used a portable X-ray fluorescence analyzer to estimate and map the concentrations of metals in surface soil in the 133 decision units comprising the OU. There is variability in lead and arsenic concentrations among the non-contiguous decision units, and an incomplete understanding of the ecological and human risks from soil contamination. While general screening criteria for lead are reported in literature, limited information is available on the impacts of heavy metals on site-specific plant and animal life. To address this information gap, a study on plant growth in Hanford soils was conducted using native bluegrass (Poa secunda), invasive cheatgrass (Bromus tectorum), and buttercrunch lettuce (Lactuca sativa). The latter is included because it is a common species used in plant growth studies. Soil samples were collected from a single general location within the 100-OL-1 OU, prepared, and categorized as having low, medium, or high concentrations of lead and arsenic, with the high concentration soil having concentrations of up to 3,400 and 790 mg/kg lead and arsenic, respectively. Additionally, a synthetic soil was prepared and used as a control, in accordance with standard plant growth protocols. Fifty-four seeds of each plant species were planted in each of the four soil types following the procedure outlined by the Washington State Department of Ecology. Germination rates and biomass measurements were recorded for 20 days. Both bluegrass and lettuce germination rates appeared to be reduced at the highest lead and arsenic concentrations (Pb: 3400 mg/kg, As: 790 mg/kg), while cheatgrass germination rates were unaffected. Total biomass for all species appeared to be related to the relative concentrations of lead and arsenic in the soil. Results of this growth study agree reasonably well with previous Hanford Site plant growth studies and provide additional data for assessing ecological risk at the Hanford Site.

54 ENVIRONMENTAL SCIENCES↗

Magnetic Sorbent for the Removal of Selenium(IV) from Simulated Industrial Wastewaters: Determination of Column Kinetic Parameters

A novel meso- and microporous tire-derived-carbon support with magnetic iron oxide nanoparticle adsorbents that selectively adsorbs Se(IV) ions from simulated contaminated water has been developed. In this work, the physicochemical characteristics of the composite adsorbent are characterized with respect to porosity and surface area, chemical composition, and microstructure morphology. The kinetics of this composite adsorbent in a fixed-bed setting has been determined. Several column runs were conducted and analyzed by inductively coupled plasma-optical emission spectroscopy (ICP-OES) to determine the concentration gradient vs time. These results were then fit to a pseudo-second order rate law to obtain equilibrium values. Combining calculated equilibrium values with effluent concentration data, enabled the application of the Adams–Bohart model to determine reaction constants and column coefficients. Column parameters obtained from different flow rates and fittings of the Adams–Bohart model were remarkably consistent. These findings enable the application of this sorbent to fixed-bed column systems and opens up further research into mixed pollutants tests with real wastewater and scaling of selenium pollutant removal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Propagating Uncertainties in the SALT3 Model-training Process to Cosmological Constraints

Type Ia supernovae (SNe Ia) are standardizable candles that must be modeled empirically to yield cosmological constraints. To understand the robustness of this modeling to variations in the model-training procedure, we build an end-to-end pipeline to test the recently developed SALT3 model. We explore the consequences of removing pre-2000s low-z or poorly calibrated U-band data, adjusting the amount and fidelity of SN Ia spectra, and using a model-independent framework to simulate the training data. We find that the SALT3 model surfaces are improved by having additional spectra and U-band data, and can be shifted by ~5% if host-galaxy contamination is not sufficiently removed from SN spectra. We find that resulting measurements of w are consistent to within 2.5% for all of the training variants explored in this work, with the largest shifts coming from variants that add color-dependent calibration offsets or host-galaxy contamination to the training spectra and those that remove pre-2000s low-z data. These results demonstrate that the SALT3 model-training procedure is largely robust to reasonable variations in the training data, but that additional attention must be paid to the treatment of spectroscopic data in the training process. We also find that the training procedure is sensitive to the color distributions of the input data—the resulting w measurement can be biased by ~2% if the color distribution is not sufficiently wide. Future low-z data, particularly u-band observations and high signal-to-noise ratio SN Ia spectra, will help to significantly improve SN Ia modeling in the coming years.

79 ASTRONOMY AND ASTROPHYSICS↗

Sonochemical oxidation and stabilization of liquid elemental mercury in water and soil

Over 3000 mercury (Hg)-contaminated sites worldwide contain liquid metallic Hg [Hg(0) 1 ] representing a continuous source of elemental Hg(0) in the environment through volatilization and solubilization in water. Currently, there are few effective treatment technologies available to remove or sequester Hg(0) 1 in situ. We investigated sonochemical treatments coupled with complexing agents, polysulfide and sulfide, in oxidizing Hg(0) 1 and stabilizing Hg in water, soil and quartz sand. Results indicate that sonication is highly effective in breaking up and oxidizing liquid Hg(0) 1 beads via acoustic cavitation, particularly in the presence of polysulfide. Without complexing agents, sonication caused only minor oxidation of Hg(0) 1 but increased headspace gaseous Hg(0) g and dissolved Hg(0) aq in water. However, the presence of polysulfide essentially stopped Hg(0) volatilization and solubilization. As a charged polymer, polysulfide was more effective than sulfide in oxidizing Hg(0) 1 and subsequently stabilizing the precipitated metacinnabar (β-HgS) nanocrystals. Sonochemical treatments with sulfide yielded incomplete oxidation of Hg(0) 1 , likely resulting from the formation of HgS coatings on the dispersed µm-size Hg(0) 1 bead surfaces. Sonication with polysulfide also resulted in rapid oxidation of Hg(0) 1 and precipitation of HgS in quartz sand and in the Hg(0) 1 -contaminated soil. This research indicates that sonochemical treatment with polysulfide could be an effective means in rapidly converting Hg(0) 1 to insoluble HgS precipitates in water and sediments, thereby preventing its further emission and release to the environment. We suggest that future studies are performed to confirm its technical feasibility and treatment efficacy for remediation applications.

36 MATERIALS SCIENCE↗