Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Slipstream Testing of Amine-Based Solvents at a Low-Rank Coal-Fired Power Plant

Conference presentation for 38th Annual International Pittsburgh Coal Conference, Virtual, September 20–23, 2021. To better assess mitigation strategies for aerosol reduction to extend solvent life, the University of North Dakota Energy & Environmental Research Center (EERC) installed a pilot-scale CO 2 absorption system at a lignite-fired plant in central North Dakota. The pilot-scale system was operated using both commercial KS-1™ solvent and advanced KS-21™ solvent provided by Mitsubishi Heavy Industries (MHI). MHI’s proprietary amine emission reduction unit (AERU™) technology was installed downstream of the absorber columns to reduce solvent losses by recovering amines at the system outlet. Fine particulate loading was measured throughout the capture system with and without a WESP operating and using both solvents. Captured particulate was brought back to the EERC to be analyzed for chemical composition and to be examined by scanning electron microscopy for particulate structure. These variables were then correlated to performance of particulate control devices in reducing aerosol formation and solvent losses.

01 COAL, LIGNITE, AND PEAT↗

Optical and electrical properties of Cu-based all oxide semi-transparent photodetector

Zero-bias operating Cu oxide-based photodetector was achieved by using large-scale available sputtering method. Cu oxide (Cu{sub 2}O or CuO) was used as p-type transparent layer to form a heterojunction by contacting n-type ZnO layer. All metal-oxide materials were employed to realize transparent device at room temperature and showed a high transparency (>75% at 600 nm) with excellent photoresponses. The structural, morphological, optical, and electrical properties of Cu oxides of CuO and Cu{sub 2}O are evaluated in depth by UV-visible spectrometer, X-ray diffraction, scanning electron microscopy, atomic force microscopy, Kelvin probe force microscopy, and Hall measurements. We may suggest a route of high-functional Cu oxide-based photoelectric devices for the applications in flexible and transparent electronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Importance of Nonequilibrium to Equilibrium Transition Pathways for the Efficiency and Stability of Organic Solar Cells

Controlled morphology of solution-processed thin films have realized impressive achievements for non-fullerene acceptor (NFA)–based organic solar cells (OSCs). Given the large set of donor–acceptor pairs, employing various processing conditions to realize optimal morphology for high efficiency and stable OSCs is a strenuous task. Therefore, comprehensive correlations between processing conditions and morphology evolution pathways have to be developed for efficient performance and stability of devices. Within the framework of the blend system, crystallization transitions of NFA molecules are tracked utilizing the first heating scan of differential scanning calorimeter (DSC) measurement correlating with respective morphology evolution of blend films. Real-time dynamics measurements and morphology characterizations are combined to provide optimal morphology transition pathways as NFA molecules are shown to be released from the mixed phase to form balanced ordered packing with variant processing conditions. Polymer:NFA films are fabricated using blade coating incorporating solvent additive or thermal annealing as processing conditions as a correlation is formulated between performance and stability of solar cells with morphology transition pathways. In conclusion, this work demonstrates the significance of processing condition-controlled transition pathways for the realization of optimal morphology leading to superior OSC devices.

14 SOLAR ENERGY↗

New leak assembly based on fluidic nanochannels

Fluidic nanochannels with a characteristic dimension of ∼280 nm were fabricated and designed as a leak assembly, where the nanochannels were formed on silicon wafers and enclosed with Pyrex{sup ®} glass. The geometric dimensions were characterized by scanning electron microscopy, and the gas flow conductance of He and other heavy gases (N{sub 2}, O{sub 2}, and Ar) was measured, and its uncertainty estimated, by the difference method. The results indicated that the measured flow conductance values were 45% less than the calculated flow conductance values. For helium, molecular flow was shown to occur at pressures ranging from vacuum to atmospheric pressure. As a consequence of the well-defined geometry, the prediction of flow conductance could be achieved for various gas species.

42 ENGINEERING↗

Elevated Electron Temperature Coincident with Observed Fusion Reactions in a Sheared-Flow-Stabilized Z Pinch

The sheared-flow-stabilized Z pinch concept has been studied extensively and is able to produce fusion-relevant plasma parameters along with neutron production over several microseconds. In this work, we present elevated electron temperature results spatially and temporally coincident with the plasma neutron source. An optical Thomson scattering apparatus designed for the FuZE device measures temperatures in the range of 1–3 keV on the axis of the device, 20 cm downstream of the nose cone. The 17-fiber system measures the radial profiles of the electron temperature. Scanning the laser time with respect to the neutron pulse time over a series of discharges allows the reconstruction of the T e temporal response, confirming that the electron temperature peaks simultaneously with the neutron output, as well as the pinch current and inductive voltage generated within the plasma. Comparison to spectroscopic ion temperature measurements suggests a plasma in thermal equilibrium. The elevated T e confirms the presence of a plasma assembled on axis, and indicates limited radiative losses, demonstrating a basis for scaling this device toward net gain fusion conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Templated fabrication and characterization of SiO{sub 2} nanotube covered Fe nanowires

In this study, Fe nanowires coated with SiO{sub 2} nanotubes have been synthesized by electrodeposition method using anodic alumina oxide template. Before growing Fe nanowires, 6–8 nm thick SiO{sub 2} nanotubes are grown inside the template using a “surface sol-gel” technique. The nanotube structures were characterized by field emission scanning electron microscopy and energy dispersive x-ray spectroscopy. Magnetic properties of the SiO{sub 2} insulated Fe nanowires inside the membrane are characterized by superconducting quantum interference device. Coercivities of around 120 Oe with field parallel to the nanowire axis and 240 Oe with field perpendicular the nanowire axis are observed at room temperature. These values are comparable to Fe nanowires without insulating layer in membrane. The magnetic hysteresis loop suggests that the SiO{sub 2} insulated nanowires have uniaxial magnetic anisotropy with the easy axis magnetization direction along the nanowire arrays due to their large shape anisotropy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-G-TeP4-04: An Automated Monte Carlo Based QA Framework for Pencil Beam Scanning Treatments

Purpose: Prior to treating new PBS field, multiple (three) patient-field-specific QA measurements are performed: two 2D dose distributions at shallow depth (M1) and at the tumor depth (M2) with treatment hardware at zero gantry angle; one 2D dose distribution at iso-center (M3) without patient specific devices at the planned gantry angle. This patient-specific QA could be simplified by the use of MC model. The results of MC model commissioning for a spot-scanning system and the fully automated TOPAS/MC-based QA framework will be presented. Methods: We have developed in-house MC interface to access a TPS (Astroid) database from a computer cluster remotely. Once a plan is identified, the interface downloads information for the MC simulations, such as patient images, apertures points, and fluence maps and initiates calculations in both the patient and QA geometries. The resulting calculations are further analyzed to evaluate the TPS dose accuracy and the PBS delivery. Results: The Monte Carlo model of our system was validated within 2.0 % accuracy over the whole range of the dose distribution (proximal/shallow part, as well as target dose part) due to the location of the measurements. The averaged range difference after commissioning was 0.25 mm over entire treatment ranges, e.g., 6.5 cm to 31.6 cm. Conclusion: As M1 depths range typically from 1 cm to 4 cm from the phantom surface, The Monte Carlo model of our system was validated within +− 2.0 % in absolute dose level over a whole treatment range. The averaged range difference after commissioning was 0.25 mm over entire treatment ranges, e.g., 6.5 cm to 31.6 cm. This work was supported by NIH/NCI under CA U19 21239.

60 APPLIED LIFE SCIENCES↗

MEMS-tunable dielectric metasurface lens

Varifocal lenses, conventionally implemented by changing the axial distance between multiple optical elements, have a wide range of applications in imaging and optical beam scanning. The use of conventional bulky refractive elements makes these varifocal lenses large, slow, and limits their tunability. Metasurfaces, a new category of lithographically defined diffractive devices, enable thin and lightweight optical elements with precisely engineered phase profiles. Here we demonstrate tunable metasurface doublets, based on microelectromechanical systems (MEMS), with more than 60 diopters (about 4%) change in the optical power upon a 1-μm movement of one metasurface, and a scanning frequency that can potentially reach a few kHz. They can also be integrated with a third metasurface to make compact microscopes (~1 mm thick) with a large corrected field of view (~500 μm or 40 degrees) and fast axial scanning for 3D imaging. This paves the way towards MEMS-integrated metasurfaces as a platform for tunable and reconfigurable optics.

42 ENGINEERING↗

Structural and electronic switching of a single crystal 2D metal-organic framework prepared by chemical vapor deposition

The incorporation of metal-organic frameworks into advanced devices remains a desirable goal, but progress is hindered by difficulties in preparing large crystalline metal-organic framework films with suitable electronic performance. We demonstrate the direct growth of large-area, high quality, and phase pure single metal-organic framework crystals through chemical vapor deposition of a dimolybdenum paddlewheel precursor, Mo 2 (INA) 4 . These exceptionally uniform, high quality crystals cover areas up to 8600 µm 2 and can be grown down to thicknesses of 30 nm. Moreover, scanning tunneling microscopy indicates that the Mo 2 (INA) 4 clusters assemble into a two-dimensional, single-layer framework. Devices are readily fabricated from single vapor-phase grown crystals and exhibit reversible 8-fold changes in conductivity upon illumination at modest powers. Moreover, we identify vapor-induced single crystal transitions that are reversible and responsible for 30-fold changes in conductivity of the metal-organic framework as monitored by in situ device measurements. Gas-phase methods, including chemical vapor deposition, show broader promise for the preparation of high-quality molecular frameworks, and may enable their integration into devices, including detectors and actuators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selected Area Manipulation of MoS 2 via Focused Electron Beam-Induced Etching for Nanoscale Device Editing

Here we demonstrate direct-write patterning of single and multilayer MoS 2 via a focused electron beam-induced etching (FEBIE) process mediated with the XeF 2 precursor. MoS 2 etching is performed at various currents, areal doses, on different substrates, and characterized using scanning electron and atomic force microscopies as well as Raman and photoluminescence spectroscopies. Scanning transmission electron microscopy reveals a sub-40 nm etching resolution and the progression of point defects and lateral etching of the consequent unsaturated bonds. The results confirm that the electron beam-induced etching process is minimally invasive to the underlying material in comparison to ion beam techniques, which damage the subsurface material. Single-layer MoS 2 field-effect transistors are fabricated, and device characteristics are compared for channels that are edited via the selected area etching process. The source–drain current at constant gate and source–drain voltage scale linearly with the edited channel width. Moreover, the mobility of the narrowest channel width decreases, suggesting that backscattered and secondary electrons collaterally affect the periphery of the removed area. Focused electron beam doses on single-layer transistors below the etching threshold were also explored as a means to modify/thin the channel layer. The FEBIE exposures showed demonstrative effects via the transistor transfer characteristics, photoluminescence spectroscopy, and Raman spectroscopy. While strategies to minimize backscattered and secondary electron interactions outside of the scanned regions require further investigation, here, we show that FEBIE is a viable approach for selective nanoscale editing of MoS 2 devices.

36 MATERIALS SCIENCE↗

Studies on magnetic properties of chemically synthesized crystalline calcium ferrite nanoparticles

Spinel-type ferrites have taken a very important role for modern electronic industry. Most of these ferrites exhibit low-loss dielectric properties, high resistivity, low eddy current and also high temperature ferromagnetism. Calcium ferrite is one such important metal oxide which is environmentally safe, chemically stable, low cost and greatly abundant. This outstanding material of calcium ferrite is synthesized by a simple chemical precipitation method using NaOH as the precipitating agent. Ferric chloride anhydrous (FeCl{sub 3}) and Calcium chloride dihydrate (CaCl{sub 2}.2H{sub 2}O) were used as iron and calcium sources respectively. The samples were heated at 200°C for 8h to obtain homogeneous powder of Calcium ferrite. The powders were characterized by using X-ray diffraction (XRD), field emission scanning electron microscope (FESEM), Transmission electrical microscopy (TEM), and Fourier transform infrared spectroscopic (FTIR) measurements. The polycrystalline nature of the sample was confirmed by X-ray diffraction study. The magnetic properties of the sample were investigated by vibrating sample magnetometer (VSM) measurements. Magnetization curve of the prepared sample depicts that as synthesized calcium ferrite nanoparticles have saturation magnetic moment of 1.74 emu/g and the coercivity of 35.08 Oe with superparamagnetic behavior. The synthesized calcium ferrite nanoparticles with such magnetic properties will be a candidate material for different applications in electronics and exploring its functionality in the field of recently developing semiconductor device physics and spintronics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Phase identification and control of thin films deposited by co-evaporation of elemental Cu, Zn, Sn, and Se

Kesterite thin films [(i.e., Cu{sub 2}ZnSn(S,Se){sub 4} and related alloys] have been the subject of recent interest for use as an absorber layer for thin film photovoltaics due to their high absorption coefficient (>10{sup 4} cm{sup -1}), their similarity to successful chalcopyrites (like CuInxGa{sub 1-x}Se{sub 2}) in structure, and their earth-abundance. The process window for growing a single-phase kesterite film is narrow. In this work, we have documented, for our 9.15%-efficient kesterite co-evaporation process, (1) how appearance of certain undesirable phases are controlled via choice of processing conditions, (2) several techniques for identification of phases in these films with resolution adequate to discern changes that are important to device performance, and (3) reference measurements for those performing such phase identification. Data from x-ray diffraction, x-ray fluorescence, Raman scattering, scanning electron microscopy, energy dispersive spectroscopy, and current-voltage characterization are presented.

36 MATERIALS SCIENCE↗

ARGon{sup 3}: ''3D appearance robot-based gonioreflectometer'' at PTB

At the Physikalisch-Technische Bundesanstalt, the National Metrology Institute of Germany, a new facility for measuring visual appearance-related quantities has been built up. The acronym ARGon{sup 3} stands for ''3D appearance robot-based gonioreflectometer''. Compared to standard gonioreflectometers, there are two main new features within this setup. First, a photometric luminance camera with a spatial resolution of 28 {mu}m on the device under test (DUT) enables spatially high-resolved measurements of luminance and color coordinates. Second, a line-scan CCD-camera mounted to a spectrometer provides measurements of the radiance factor, respectively the bidirectional reflectance distribution function, in full V({lambda})-range (360 nm-830 nm) with arbitrary angles of irradiation and detection relative to the surface normal, on a time scale of about 2 min. First goniometric measurements of diffuse reflection within 3D-space above the DUT with subsequent colorimetric representation of the obtained data of special effect pigments based on the interference effect are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impacts of Ion Segregation on Local Optical Properties in Mixed Halide Perovskite Films

Despite the recent astronomical success of organic–inorganic perovskite solar cells (PSCs), the impact of microscale film inhomogeneities on device performance remains poorly understood. In this work, we study CH 3 NH 3 PbI 3 perovskite films using cathodoluminescence in scanning transmission electron microscopy and show that localized regions with increased cathodoluminescence intensity correspond to iodide-enriched regions. These observations constitute direct evidence that nanoscale stoichiometric variations produce corresponding inhomogeneities in film cathodoluminescence intensity. Furthermore, we observe the emergence of high-energy transitions attributed to beam induced iodide segregation, which may mirror the effects of ion migration during PSC operation. Our results demonstrate that such ion segregation can fundamentally change the local optical and microstructural properties of organic–inorganic perovskite films in the course of normal device operation and thus address the observed complex and unpredictable behavior in PSC devices.

36 MATERIALS SCIENCE↗

Mitigating Structural Defects in Droop-Minimizing InGaN/GaN Quantum Well Heterostructures

Modern commercial InGaN/GaN blue LEDs continue to suffer from efficiency droop, a reduction in efficiency with increasing drive current. External quantum efficiency (EQE) typically peaks at low drive currents (< 10 A cm 2 ) and drops monotonically at higher current densities, falling to <85% of the peak EQE at a drive current of 100 A cm 2 . Mitigating droop-related losses will yield tremendous gains in both luminous efficacy (lumens/W) and cost (lumens/$). Such improvements are critical for continued large-scale market penetration of LED technologies, particularly in high-power and high flux per unit area applications. However, device structures that reduce droop typically require higher indium content and are accompanied by a corresponding degradation in material quality which negates the droop improvement via enhanced Shockley-Read-Hall (SRH) recombination. In this work, we use advanced characterization techniques to identify and classify structural defects in InGaN/GaN quantum well (QW) heterostructures that share features with low-droop designs. Using aberration-corrected scanning transmission electron microscopy (C s -STEM), we find the presence of severe well width fluctuations (WWFs) in a number of low droop device architectures. However, the presence of WWFs does not correlate strongly with external quantum efficiency nor defect densities measured via deep level optical spectroscopy (DLOS). Hence, performance losses in the heterostructures of interest are likely dominated by nanoscale point or interfacial defects rather than large-scale extended defects.

36 MATERIALS SCIENCE↗

Validation of a 4D-PET Maximum Intensity Projection for Delineation of an Internal Target Volume

Purpose: The delineation of internal target volumes (ITVs) in radiation therapy of lung tumors is currently performed by use of either free-breathing (FB) {sup 18}F-fluorodeoxyglucose-positron emission tomography-computed tomography (FDG-PET/CT) or 4-dimensional (4D)-CT maximum intensity projection (MIP). In this report we validate the use of 4D-PET-MIP for the delineation of target volumes in both a phantom and in patients. Methods and Materials: A phantom with 3 hollow spheres was prepared surrounded by air then water. The spheres and water background were filled with a mixture of {sup 18}F and radiographic contrast medium. A 4D-PET/CT scan was performed of the phantom while moving in 4 different breathing patterns using a programmable motion device. Nine patients with an FDG-avid lung tumor who underwent FB and 4D-PET/CT and >5 mm of tumor motion were included for analysis. The 3 spheres and patient lesions were contoured by 2 contouring methods (40% of maximum and PET edge) on the FB-PET, FB-CT, 4D-PET, 4D-PET-MIP, and 4D-CT-MIP. The concordance between the different contoured volumes was calculated using a Dice coefficient (DC). The difference in lung tumor volumes between FB-PET and 4D-PET volumes was also measured. Results: The average DC in the phantom using 40% and PET edge, respectively, was lowest for FB-PET/CT (DCAir = 0.72/0.67, DCBackground 0.63/0.62) and highest for 4D-PET/CT-MIP (DCAir = 0.84/0.83, DCBackground = 0.78/0.73). The average DC in the 9 patients using 40% and PET edge, respectively, was also lowest for FB-PET/CT (DC = 0.45/0.44) and highest for 4D-PET/CT-MIP (DC = 0.72/0.73). In the 9 lesions, the target volumes of the FB-PET using 40% and PET edge, respectively, were on average 40% and 45% smaller than the 4D-PET-MIP. Conclusion: A 4D-PET-MIP produces volumes with the highest concordance with 4D-CT-MIP across multiple breathing patterns and lesion sizes in both a phantom and among patients. Freebreathing PET/CT consistently underestimates ITV when compared with 4D PET/CT for a lesion affected by respiration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TAKASAGO-6 apparatus for cryogenic coherent X-ray diffraction imaging of biological non-crystalline particles using X-ray free electron laser at SACLA

Coherent X-ray diffraction imaging (CXDI) is a technique for structure analyses of non-crystalline particles with dimensions ranging from micrometer to sub-micrometer. We have developed a diffraction apparatus named TAKASAGO-6 for use in single-shot CXDI experiments of frozen-hydrated non-crystalline biological particles at cryogenic temperature with X-ray free electron laser pulses provided at a repetition rate of 30 Hz from the SPring-8 Angstrom Compact free-electron LAser. Specimen particles are flash-cooled after being dispersed on thin membranes supported by specially designed disks. The apparatus is equipped with a high-speed translation stage with a cryogenic pot for raster-scanning of the disks at a speed higher than 25 μm/33 ms. In addition, we use devices assisting the easy transfer of cooled specimens from liquid-nitrogen storages to the cryogenic pot. In the current experimental procedure, more than 20 000 diffraction patterns can be collected within 1 h. Here we report the key components and performance of the diffraction apparatus. Based on the efficiency of the diffraction data collection and the structure analyses of metal particles, biological cells, and cellular organelles, we discuss the future application of this diffraction apparatus for structure analyses of biological specimens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-638: Proton Beam Delivery to a Moving Lung Tumor and Monte Carlo Simulation with TOPAS

Purpose: To estimate the dose delivered to a moving lung tumor by proton therapy beams of different modulation types, and compare with Monte Carlo predictions. Methods: A radiology support devices (RSD) phantom was irradiated with therapeutic proton radiation beams using two different types of modulation: uniform scanning (US) and double scattered (DS). The Eclipse© dose plan was designed to deliver 1.00Gy to the isocenter of a static ∼3×3×3cm (27cc) tumor in the phantom with 100% coverage. The peak to peak amplitude of tumor motion varied from 0.0 to 2.5cm. The radiation dose was measured with an ion-chamber (CC-13) located within the tumor. The time required to deliver the radiation dose varied from an average of 65s for the DS beams to an average of 95s for the US beams. Results: The amount of radiation dose varied from 100% (both US and DS) to the static tumor down to approximately 92% for the moving tumor. The ratio of US dose to DS dose ranged from approximately 1.01 for the static tumor, down to 0.99 for the 2.5cm moving tumor. A Monte Carlo simulation using TOPAS included a lung tumor with 4.0cm of peak to peak motion. In this simulation, the dose received by the tumor varied by ∼40% as the period of this motion varied from 1s to 4s. Conclusion: The radiation dose deposited to a moving tumor was less than for a static tumor, as expected. At large (2.5cm) amplitudes, the DS proton beams gave a dose closer to the desired dose than the US beams, but equal within experimental uncertainty. TOPAS Monte Carlo simulation can give insight into the moving tumor — dose relationship. This work was supported in part by the Philips corporation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗