Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Clinical Utility of 4D FDG-PET/CT Scans in Radiation Treatment Planning

Purpose: The potential role of four-dimensional (4D) positron emission tomography (PET)/computed tomography (CT) in radiation treatment planning, relative to standard three-dimensional (3D) PET/CT, was examined. Methods and Materials: Ten patients with non-small-cell lung cancer had sequential 3D and 4D [{sup 18}F]fluorodeoxyglucose PET/CT scans in the treatment position prior to radiation therapy. The gross tumor volume and involved lymph nodes were contoured on the PET scan by use of three different techniques: manual contouring by an experienced radiation oncologist using a predetermined protocol; a technique with a constant threshold of standardized uptake value (SUV) greater than 2.5; and an automatic segmentation technique. For each technique, the tumor volume was defined on the 3D scan (VOL3D) and on the 4D scan (VOL4D) by combining the volume defined on each of the five breathing phases individually. The range of tumor motion and the location of each lesion were also recorded, and their influence on the differences observed between VOL3D and VOL4D was investigated. Results: We identified and analyzed 22 distinct lesions, including 9 primary tumors and 13 mediastinal lymph nodes. Mean VOL4D was larger than mean VOL3D with all three techniques, and the difference was statistically significant (p < 0.01). The range of tumor motion and the location of the tumor affected the magnitude of the difference. For one case, all three tumor definition techniques identified volume of moderate uptake of approximately 1 mL in the hilar region on the 4D scan (SUV maximum, 3.3) but not on the 3D scan (SUV maximum, 2.3). Conclusions: In comparison to 3D PET, 4D PET may better define the full physiologic extent of moving tumors and improve radiation treatment planning for lung tumors. In addition, reduction of blurring from free-breathing images may reveal additional information regarding regional disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Texture in Serial Thoracic Computed Tomography Scans: Correlation of Radiomics-based Features With Radiation Therapy Dose and Radiation Pneumonitis Development

Purpose: To assess the relationship between radiation dose and change in a set of mathematical intensity- and texture-based features and to determine the ability of texture analysis to identify patients who develop radiation pneumonitis (RP). Methods and Materials: A total of 106 patients who received radiation therapy (RT) for esophageal cancer were retrospectively identified under institutional review board approval. For each patient, diagnostic computed tomography (CT) scans were acquired before (0-168 days) and after (5-120 days) RT, and a treatment planning CT scan with an associated dose map was obtained. 32- × 32-pixel regions of interest (ROIs) were randomly identified in the lungs of each pre-RT scan. ROIs were subsequently mapped to the post-RT scan and the planning scan dose map by using deformable image registration. The changes in 20 feature values (ΔFV) between pre- and post-RT scan ROIs were calculated. Regression modeling and analysis of variance were used to test the relationships between ΔFV, mean ROI dose, and development of grade ≥2 RP. Area under the receiver operating characteristic curve (AUC) was calculated to determine each feature's ability to distinguish between patients with and those without RP. A classifier was constructed to determine whether 2- or 3-feature combinations could improve RP distinction. Results: For all 20 features, a significant ΔFV was observed with increasing radiation dose. Twelve features changed significantly for patients with RP. Individual texture features could discriminate between patients with and those without RP with moderate performance (AUCs from 0.49 to 0.78). Using multiple features in a classifier, AUC increased significantly (0.59-0.84). Conclusions: A relationship between dose and change in a set of image-based features was observed. For 12 features, ΔFV was significantly related to RP development. This study demonstrated the ability of radiomics to provide a quantitative, individualized measurement of patient lung tissue reaction to RT and assess RP development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of laser scanning speed on the microstructure, phase transformation and mechanical property of NiTi alloys fabricated by $\mathrm{LPBF}$

This study investigated the effects of laser scanning speed on the microstructure, phase transformation and properties of NiTi alloys fabricated by laser powder bed fusion (LPBF). In this study, the contributions of metallurgical factors under different scanning speeds, such as Ni evaporation, Ni4Ti3 precipitation, dislocations and internal stress, to the transformation temperature and transformation latent heat were clarified through specially designed experiments. Ni evaporation is found to have the most profound effect, followed by precipitation. Increasing scanning speed is found to reduce Ni loss, thus cause less increase in the transformation temperature and transformation heat of the LPBF-NiTi alloys. Increasing scanning speed also increases the microstructure non-uniformity and thus widens the transformation temperature interval. The orientations of residual stress exhibit strong crystallographic stiffness dependence. The LPBF-NiTi alloys with different scanning speeds all exhibited high strains (>13.4%) and excellent shape memory effect. A LPBF-NiTi honeycomb structure exhibited 96% shape recovery rate after a 60% pre-compressive deformation. Besides, there is an optimum scanning speed for minimum porosity and smallest average pore size. However, the pore structure is found to have weak influence on the tensile behaviour of the LPBF-NiTi alloys, possibly due to the high defect tolerance of the martensitic transformation.

36 MATERIALS SCIENCE↗

SU-E-I-48: The Behavior of AEC in Scan Regions Outside the Localizer Radiograph FOV: An In Phantom Study of CT Systems From Four Vendors

Purpose: This review of scanners from 4 major manufacturers examines the clinical impact of performing CT scans that extend into areas of the body that were not acquired in the CT localizer radiograph. Methods: Anthropomorphic chest and abdomen phantoms were positioned together on the tables of CT scanners from 4 different vendors. All of the scanners offered an Automatic Exposure Control (AEC) option with both lateral and axial tube current modulation. A localizer radiograph was taken covering the entire extent of both phantoms and then the scanner's Chest-Abdomen-Pelvis (CAP) study was performed with the clinical AEC settings employed and the scan and reconstruction range extending from the superior portion of the chest phantom through the inferior portion of the abdomen phantom. A new study was then initiated with a localizer radiograph extending the length of the chest phantom (not covering the abdomen phantom). The same CAP protocol and AEC settings were then used to scan and reconstruct the entire length of both phantoms. Scan parameters at specific locations in the abdomen phantom from both studies were investigated using the information contained in the DICOM metadata of the reconstructed images. Results: The AEC systems on all scanners utilized different tube current settings in the abdomen phantom for the scan completed without the full localizer radiograph. The AEC system behavior was also scanner dependent with the default manual tube current, the maximum tube current and the tube current at the last known position observed as outcomes. Conclusion: The behavior of the AEC systems of CT scanners in regions not covered by the localizer radiograph is vendor dependent. To ensure optimal image quality and radiation exposure it is important to include the entire planned scan region in the localizer radiograph.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-56: Scan Angle Reduction for a Limited-Angle Intrafraction Verification (LIVE) System

Purpose: To develop a novel adaptive reconstruction strategy to further reduce the scanning angle required by the limited-angle intrafraction verification (LIVE) system for intrafraction verification. Methods: LIVE acquires limited angle MV projections from the exit fluence of the arc treatment beam or during gantry rotation between static beams. Orthogonal limited-angle kV projections are also acquired simultaneously to provide additional information. LIVE considers the on-board 4D-CBCT images as a deformation of the prior 4D-CT images, and solves the deformation field based on deformation models and data fidelity constraint. LIVE reaches a checkpoint after a limited-angle scan, and reconstructs 4D-CBCT for intrafraction verification at the checkpoint. In adaptive reconstruction strategy, a larger scanning angle of 30° is used for the first checkpoint, and smaller scanning angles of 15° are used for subsequent checkpoints. The onboard images reconstructed at the previous adjacent checkpoint are used as the prior images for reconstruction at the current checkpoint. As the algorithm only needs to reconstruct the small deformation occurred between adjacent checkpoints, projections from a smaller scan angle provide enough information for the reconstruction. XCAT was used to simulate tumor motion baseline drift of 2mm along sup-inf direction at every subsequent checkpoint, which are 15° apart. Adaptive reconstruction strategy was used to reconstruct the images at each checkpoint using orthogonal 15° kV and MV projections. Results: Results showed that LIVE reconstructed the tumor volumes accurately using orthogonal 15° kV-MV projections. Volume percentage differences (VPDs) were within 5% and center of mass shifts (COMS) were within 1mm for reconstruction at all checkpoints. Conclusion: It's feasible to use an adaptive reconstruction strategy to further reduce the scan angle needed by LIVE to allow faster and more frequent intrafraction verification to minimize the treatment errors in lung cancer treatments. Grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

SPRUCE Terrestrial Laser Scanning of Experimental Plots, Beginning in 2015

This data set comprises terrestrial laser scanning (TLS) point clouds from the SPRUCE experimental plots located in the S1-Bog of the Marcell Experimental Forest (MEF) near Grand Rapids, Minnesota. In 2015 and 2020 the 12 experimental SPRUCE plots were scanned near peak foliage ("summer”). In 2016-2019 and 2021-2023 the 12 plots were scanned prior to green up ("spring”) and once near peak foliage (Table 1). Additional data will be added through summer 2025. A RIEGL VZ-1000 unit was used to collect all scans. Four TLS scans in each plot were registered to produce a single point cloud per plot using RiSCAN PRO v2.3 software. Up to six additional scans were registered to account for data occlusion when necessary. Point clouds are saved in LAS (*.las) 1.2 format. Point clouds were geo-registered to surveyed plot locations. There are 192 *.las files provided with this dataset.

54 ENVIRONMENTAL SCIENCES↗

Assessment of virtual towers performed with scanning wind lidars and Ka-band radars during the XPIA experiment

During the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA) campaign, which was carried out at the Boulder Atmospheric Observatory (BAO) in spring 2015, multiple-Doppler scanning strategies were carried out with scanning wind lidars and Ka-band radars. Specifically, step–stare measurements were collected simultaneously with three scanning Doppler lidars, while two scanning Ka-band radars carried out simultaneous range height indicator (RHI) scans. The XPIA experiment provided the unique opportunity to compare directly virtual-tower measurements performed simultaneously with Ka-band radars and Doppler wind lidars. Furthermore, multiple-Doppler measurements were assessed against sonic anemometer data acquired from the meteorological tower (met-tower) present at the BAO site and a lidar wind profiler. This survey shows that – despite the different technologies, measurement volumes and sampling periods used for the lidar and radar measurements – a very good accuracy is achieved for both remote-sensing techniques for probing horizontal wind speed and wind direction with the virtual-tower scanning technique.

17 WIND ENERGY↗

Characterization of Artifacts Introduced by the Empirical Volcano-Scan Atmospheric Correction Commonly Applied to CRISM and OMEGA Near-Infrared Spectra

The empirical volcano-scan atmospheric correction is widely applied to Martian near infrared CRISM and OMEGA spectra between 1000 and 2600 nanometers to remove prominent atmospheric gas absorptions with minimal computational investment. This correction method employs division by a scaled empirically-derived atmospheric transmission spectrum that is generated from observations of the Martian surface in which different path lengths through the atmosphere were measured and transmission calculated using the Beer-Lambert Law. Identifying and characterizing both artifacts and residual atmospheric features left by the volcano-scan correction is important for robust interpretation of CRISM and OMEGA volcano scan corrected spectra. In order to identify and determine the cause of spectral artifacts introduced by the volcano-scan correction, we simulated this correction using a multiple scattering radiative transfer algorithm (DISORT). Simulated transmission spectra that are similar to actual CRISM- and OMEGA-derived transmission spectra were generated from modeled Olympus Mons base and summit spectra. Results from the simulations were used to investigate the validity of assumptions inherent in the volcano-scan correction and to identify artifacts introduced by this method of atmospheric correction. We found that the most prominent artifact, a bowl-shaped feature centered near 2000 nanometers, is caused by the inaccurate assumption that absorption coefficients of CO2 in the Martian atmosphere are independent of column density. In addition, spectral albedo and slope are modified by atmospheric aerosols. Residual atmospheric contributions that are caused by variable amounts of dust aerosols, ice aerosols, and water vapor are characterized by the analysis of CRISM volcano-scan corrected spectra from the same location acquired at different times under variable atmospheric conditions.

OMEGA Near Infrared↗

High-speed wide-angle interleaved scanning technique for a 3D imaging lidar

In this paper, we describe a novel interleaved scanner for an eye-safe 3D scanning lidar system to measure aerodynamic phenomena in a wind tunnel using elastic backscatter from seeding particles. The scanner assembly consists of a rotating polygon scanner for line scanning along the fast axis, a galvanometer (galvo) scanner for scanning along the slow axis, angular position sensors and motor controllers. The polygon scanner sweeps the lidar beam at up to 10,000 lines/s across a 27 deg angular field-of-regard in the fast axis, while the galvo scanner covers an angular range of 20 deg in the slow axis. Using this scanner, the lidar can perform non-intrusive flow visualization, velocimetry, and hard target mapping at mmscale spatial resolution to a standoff range of 5 m at an update rate of 50 Hz for the full field-of-regard. An interleaved scanning methodology for the acquisition of two snapshots of 3D lidar intensity data with a 100 μs time offset is discussed. The design of the control and data acquisition electronics is described. The effects of rapid scanning on the response of a narrow field-of-view lidar are addressed. The design of the scanner is scalable and can be tailored to meet the requirements of other applications by increasing or decreasing the standoff range, angular field-of-regard and scan rate.

3D Imaging Lidar↗

Microgamma Scan System for analyzing radial isotopic profiles of irradiated transmutation fuels

The U. S. Global Nuclear Energy Partnership / Advanced Fuel Cycle Initiative (GNEP/AFCI) is developing metallic transmutation alloys as a fuel form to transmute the long-lived transuranic actinide isotopes contained in spent nuclear fuel into shorter-lived fission products. The AFCI program has irradiated and examined eleven metallic alloy transmutation fuel specimens to evaluate the feasibility of actinide transmutation in advanced sodium-cooled fast reactors and thermal reactor implementation. Initial results of postirradiation examinations indicated the irradiation performance of the actinide-bearing compositions is similar to uranium-plutonium-zirconium ternary metallic alloy fuels (U-xPu-10Zr). Further studies to characterize radial burnup profile, constituent migration, and fuel cladding chemical interaction (FCCI) are in progress. A microgamma scan system is being developed to analyze the radial distribution of fission products, such as Cs-137, Cs-134, Ru-106, and Zr-95, in irradiated fuel cross-sections. The microgamma scan system consists of a set of indexed sample collimator blocks and a sample holder, which interfaces with the INL Analytical Laboratory Hot Cell (ALHC) Gamma Scan System high purity germanium detector, multichannel analyzer, and removable collimators. The microgamma scan results will be used to evaluate radial burnup profile, cesium migration to the sodium bond and constituent migration within the fuel. These data will further clarify the comparative irradiation performance of actinide-bearing metallic transmutation fuel forms and uranium-plutonium-zirconium alloys. Preliminary measurements of the microgamma scan system will be discussed. A simplified model of the microgamma scan system was developed in MCNP and used to investigate the system performance and to interpret data from the scoping studies. Recommendations for improving the MCGS analyses are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Orthopedic metallic hardware in routine abdomino-pelvic CT scans: occurrence and clinical significance

Purpose: To study the occurrence of orthopedic metallic hardware in routine abdomen/pelvic computed tomography (CT) scans and their impact on image quality (IQ) and diagnostic evaluation. Material and methods: In this retrospective single institution study, we analyzed 3500 consecutive abdomen/pelvis CT scans for occurrence of orthopedic metallic hardware. In the cohort of patients with metallic hardware detected on CT scans, subjective and objective IQ analysis was performed to estimate diagnostic acceptability (DA, 4-point scale), subjective noise (SN, 3-point scale), presence of artifacts (PA, 4-point scale) and objective noise. The clinical significance of metallic hardware was determined by evaluating the impact of artifacts on radiological diagnosis according to the clinical indication and disease type. Results: Orthopedic metallic hardware was encountered in 4.97% of abdomino-pelvic CT scans (n = 174/3500), and artifacts related to the hardware in the region of clinical interest were identified in 82% (n = 144/174) of scans. The overall mean DA was 2.66 (n = 174), and it was severely limited (score < 2) in 32% of cases particularly affecting patients with bilateral hip implants (92.6%, n = 25/27). The artifacts due to hardware significantly limited diagnostic evaluation in 58.6% of cases (PA score ≥ 3), and the image noise was unacceptable in 71% of cases (SN score > 2) in the region of clinical interest. Conclusion: Orthopedic metallic hardware is encountered in nearly 5% of abdomino-pelvic CT scans and causes significant image degradation limiting diagnostic evaluation in the region of clinical interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal Behavior During the Selective Laser Melting Process of Ti-6Al-4V Powder in the Point Exposure Scan Pattern

Currently, there are two main scan patterns, including the continuous exposure scan pattern and the point exposure scan pattern, during the selective laser melting (SLM) process. The point exposure scan pattern allows a three-dimensional (3-D) printer to build finer detail features as a static molten pool that is more stable than a dynamic one. However, there has been limited theoretical research on the thermal behavior characteristics during the process in the point exposure scan pattern. Therefore, in this study, the simulation of thermal behavior during SLM of Ti-6Al-4V powder in the point exposure scan pattern was performed. The temperature evolution behavior of different positions and the effects of exposure time on the temperature evolution behavior of different positions, temperature distributions, and dimensions of the molten pool were investigated. The results showed that the direct exposure position and unexposed position had significantly different temperature evolution behaviors under a given condition, and the changed exposure time had the greatest influence on the direct exposure position compared with unexposed position. Moreover, the thermal accumulation effect of a former exposure point on a later one decreased with increasing exposure time. In addition, with the increase of exposure time, the maximum temperature of the molten pool was enhanced and the surface morphology of the molten pool changed from an approximate ellipse to an approximate circle. Besides, the molten pool dimensions were found to increase with exposure time, which indicated that the exposure time played an important role in the stability of the molten pool and the metallurgical bonding in the process. Furthermore, the dimensions of the molten pool and metallurgical bonding in the cross-sectional view were obtained through experiments. Good agreement was obtained when comparing the simulated results with the experimental ones.

36 MATERIALS SCIENCE↗

Single Analyzer Precursor Ion Scans in a Linear Quadrupole Ion Trap Using Orthogonal Double Resonance Excitation

Reported herein is a simple method of performing single analyzer precursor ion scans in a linear quadrupole ion trap using orthogonal double resonance excitation. A first supplementary AC signal applied to the y electrodes is scanned through ion secular frequencies in order to mass-selectively excite precursor ions while, simultaneously, a second fixed-frequency AC signal is applied orthogonally on the x electrodes in order to eject product ions of selected mass-to-charge ratios towards the detector. The two AC signals are applied orthogonally so as to preclude the possibility of (1) inadvertently ejecting precursor ions into the detector, which results in artifact peaks, and (2) prevent beat frequencies on the x electrodes from ejecting ions off-resonance. Precursor ion scans are implemented while using the inverse Mathieu q scan for easier mass calibration. The orthogonal double resonance experiment results in single ion trap precursor scans with far less intense artifact peaks than when both AC signals are applied to the same electrodes, paving the way for implementation of neutral loss scanning in single ion trap mass spectrometers. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of Precursor and Neutral Loss Scans on a Miniature Ion Trap Mass Spectrometer and Performance Comparison to a Benchtop Linear Ion Trap

Implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 miniature rectilinear ion trap mass spectrometer is described, and performance is compared to that of a commercial Thermo linear trap quadropole (LTQ) linear ion trap. The ac frequency scan version of the technique at constant rf voltage is used here because it is operationally much simpler to implement. Remarkably, the Mini 12 shows up to two orders of magnitude higher sensitivity compared to that of the LTQ. Resolution on the LTQ is better than unit at scan speeds of ~ 400 Th/s, whereas peak widths on the Mini 12, on average, range from 0.5 to 2.0 Th full width at half maximum and depend heavily on the precursor ion Mathieu q parameter as well as the pump down time that precedes the mass scan. Both sensitivity and resolution are maximized under higher pressure conditions (short pump down time) on the Mini 12. The effective mass range of the product ion ejection waveform was found to be 5.8 Th on the Mini 12 in the precursor ion scan mode vs. that of 3.9 Th on the LTQ. In the neutral loss scan mode, the product ion selectivity was between 8 and 11 Th on the Mini 12 and between 7 and 8 Th on the LTQ. The effects of nonlinear resonance lines on the Mini 12 were also explored. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of Early Postradiation Magnetic Resonance Imaging Scans in Children With Diffuse Intrinsic Pontine Glioma

Purpose: To determine optimal timing of assessing postradiation radiographic response on magnetic resonance imaging (MRI) scans in pediatric patients with diffuse intrinsic pontine glioma (DIPG). Methods and Materials: Patients were treated on a prospective study at the National Cancer Institute (Protocol no. 06-C-0219) evaluating the effects of radiotherapy (RT). Standard RT was administered in standard fractionation over 6 weeks. Postradiation MRI scans were performed at 2 and 6-8 weeks. Results: Eleven patients with DIPG were evaluated. Median age was 6 years (range, 4-13 years). Patients were treated with external-beam RT to 55.8 Gy (n = 10) or 54 Gy (n = 1), with a gross tumor volume to planning target volume expansion of 1.8-2.0 cm. All patients received prescribed dose and underwent posttreatment MRI scans at 2 and 6-8 weeks. Pretreatment imaging revealed compression of fourth ventricle (n = 11); basilar artery encasement (n = 9); tumor extension outside the pons (n = 11); and tumor hemorrhage (n = 2). At the 2-week scan, basilar artery encasement improved in 7 of 9 patients, and extent of tumor was reduced in 5 of 11 patients. Fourth ventricle compression improved in 6 of 11 patients but worsened in 3 of 11 patients. Presumed necrosis was observed in 5 of 11 patients at 2 weeks and in 1 additional patient at 6-8 weeks. There was no significant difference in mean anteroposterior and transverse diameters of tumor between the 2- and 6-8-week time points. Six of 11 patients had increasing ventricular size, with no evidence of obstruction. Conclusions: There is no significant difference in tumor size of DIPG patients who have received standard RT when measured at 2 weeks vs. 6-8 weeks after RT. The majority of patients had the largest change in tumor size at the 2-week post-RT scan, with evolving changes documented on the 6-8-week scan. Six of 11 patients had progressive ventriculomegaly without obstruction, suggestive of communicating hydrocephalus. To the best of our knowledge, this is the first documentation of this phenomenon in this cohort of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scanning Electrochemical Microscopy: An Evolving Toolbox for Revealing the Chemistry within Electrochemical Processes

The parallel development of ultramicroelectrodes (UMEs) and groundbreaking scanning probe microscopy techniques in the late 1980s led to the development of the scanning electrochemical microscope. Scanning electrochemical microscopy (SECM) was born from the idea of using a tiny electrode to measure the local electrochemical behavior at operating electrodes. From its foundations, the technique displayed an inherent versatility in measuring sample properties beyond topography. It allowed experimenters to measure and map chemical reactions occurring at diverse interfaces, from inspecting the reversibility of redox mediators at metal electrodes, to detecting the hallmarks of cellular respiration on living plant leaves. Related but distinct electrochemical scanning probe techniques, such as electrochemical atomic force microscopy (EC-AFM), scanning ion conductance microscopy (SICM), and scanning electrochemical cell microscopy (SECCM) have developed in parallel. These techniques have demonstrated exquisite spatial resolution down to the nanoscale regime. However, it is the proposition of this review that SECM remains unmatched at revealing the chemical aspects of electrochemistry. Furthermore, it is our intention to review and demonstrate that the versatile architecture of SECM continues to evolve and address fundamental and emerging challenges in the fields of energy storage and conversion, chemical biology, materials science, and environmental chemistry, among others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of the Laser Scanning Rate on the Structure of Rotating Lattice Single Crystal Lines

Localized controlled heating of glass with a continuous wave laser has introduced the possibility of engineering the lattice of recently discovered rotating lattice single (RLS) crystals and thus obtaining novel metamaterials. On this account, we report the role of the laser scanning speed on the lattice structure of a model system: Sb 2 S 3 straight RLS crystal lines created in a 16SbI 3 -84Sb 2 S 3 glass. The electron backscatter diffraction analysis shows that above a critical laser scanning speed the lattice rotates along the direction of scanning, the rate of lattice rotation is relatively insensitive to scanning speed, and the growth front is symmetric. In contrast, for laser scanning speeds below this critical value, the rate and direction of lattice rotation are strongly affected by the speed. Further, the growth front becomes asymmetric, which promotes the formation of new grains misoriented by ≤10°. These observations are reported on in terms of the relative dominance of the temperature gradient from laser scanning vis-á-vis the intrinsic preferred crystallographic direction of crystal growth. In addition to providing guidelines for fabricating the RLS crystal of the desired rate of the lattice rotation, new insight is gained for the mechanism of plumose formation in spherulitic crystals.

36 MATERIALS SCIENCE↗

On-the-fly scans for X-ray ptychography

With the increasing importance of nanotechnology, the need for reliable real-time imaging of mesoscopic objects with nanometer resolution is rising. For X-ray ptychography, a scanning microscopy technique that provides nanometric resolution on extended fields of view, and the settling time of the scanning system is one of the bottlenecks for fast imaging. Here, we demonstrate that ptychographic on-the-fly scans, i.e., collecting diffraction patterns while the sample is scanned with constant velocity, can be modelled as a state mixture of the probing radiation and allow for reliable image recovery. Characteristics of the probe modes are discussed for various scan parameters, and the application to significantly reducing the scanning time is considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗