Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Determination of water equivalent content in fuel rods

In water-cooled reactors, hydriding failure of zircaloy cladding tubes can be easily caused by high content of total water in fuel rods. WEC, which is the water equivalent content within the cold space of a fuel rod, directly reflects the total water content of the fuel rod. A device measuring WEC has been designed, manufactured and tested. This extraction device is a hermetically sealed system consisting of six parts: the break-off part, the heating unit, the reduction unit, the sample storage part, the collecting unit and the gas flow system. Each part is connected to another one using a special connection, and the device's end part is connected to a gas chromatograph. The determination procedure can be briefly summarized as follows: first, a test fuel rod should be put into the sealed device after lathing two circular grooves on both ends, so that it can be easily broken at these points in the break-off part. Driven by carrier gas, water and hydrogen both contained in helium gas and absorbed on the rod in-wall pass over the hot uranium filament where water is converted into hydrogen. After being concentrated by the collecting unit, hydrogen flows into the gas chromatograph for measurement and data are calculated as total water content A. UO{sub 2} pellets in the test rod should be taken out from the sample storage part and the total hydrogen content of these pellets is determined according to ASTM C1457 standard, followed by its conversion into total water content B. Finally, the sum of A and B being divided by the free volume of the cold space within the test rod, gives the value of WEC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In situ monitoring of hydrogen loss during pyrolysis of wood by neutron imaging

Hydrogen is an element of fundamental importance for energy but hard to quantify in bulk materials. Neutron radiography was used to map in situ loss of elemental hydrogen from beech tree wood samples during pyrolysis. The samples consisted of three wood cylinders (finished dowel or cut branch) of approximately 1 cm in length. The samples were pyrolyzed under vacuum in a furnace vessel that was placed inside a cold neutron imaging beamline using a temperature ramp of 5 °C/min from ambient up to 400 °C. Neutron radiographs with exposures of 30 s were sequentially recorded with a charge-coupled device over the course of the experiment. Relative absorbance/scattering of the neutron beam by each sample was based on intensity (or brightness) values as a function of pixel position. The much larger neutron cross section for hydrogen compared to carbon and oxygen enables almost direct conversion of neutron attenuation into sample hydrogen content for each time step during the pyrolysis experiment. Target and vessel temperatures were recorded concurrently with collection of the radiographs so that changes could be directly correlated to different states of pyrolysis. The most visible change appeared at the initial phase of the 400 °C plateau as evidenced by strong hydrogen loss and primarily diametric shrinking of the samples. In conclusion, the loss of elemental hydrogen between initial and final states of pyrolysis was estimated to be about 70%.

08 HYDROGEN↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

Characterizing sample degradation from synchrotron based X-ray measurements of ultra-thin exfoliated flakes

It is undeniable that novel 2D devices and heterostructures will have a lasting impact on the advancement of future technologies. However, the inherent instability of many exfoliated van der Waals (vdW) materials is a well-known hurdle yet to be overcome. Thus, the sustained interest in exfoliated vdW materials underscores the importance of understanding the mechanisms of sample degradation to establish proactive protective measures. Here, the impact of prolonged synchrotron-based X-ray beam exposure on exfoliated flakes of two contemporary vdW materials, NiPS 3 and α-RuCl 3 , is explored using resonant inelastic X-ray scattering (RIXS) and total fluorescence yield X-ray absorption spectroscopy (XAS). In NiPS 3 , the resulting RIXS and XAS spectra show a suppression, then vanishing, of NiS 6 multiplet excitations coupled with an upward shift of the peak energy of the XAS as a function of X-ray dose. In α-RuCl 3 , the signs of beam damage from the RIXS spectra are less evident. However, the post-experiment characterization of both materials using Raman spectroscopy exhibits signals of an amorphous and disordered system compared to pristine flakes; in addition, energy-dispersive X-ray spectroscopy of NiPS 3 shows evidence of ligand vacancies. As synchrotron radiation is fast becoming a required probe to study 2D vdW materials, these findings lay the groundwork for the development of future protective measures for synchrotron-based prolonged X-ray beam exposure, as well as for X-ray free electron laser.

2D magnetism↗

Modification of defects and potential fluctuations in slow-cooled and quenched Cu 2 ZnSnSe 4 single crystals

Recent literature reports have shown the ability to manipulate Cu-Zn cation ordering for Cu 2 ZnSnSe 4 (CZTSe) via low temperature treatments. Theoretical arguments suggest that one of the major roadblocks to higher V OC —significant band tailing—could be improved with increased cation order; however, few direct measurements have been reported and significant device improvements have not yet been realized. This paper investigates electrical properties, defects, and devices from quenched and slow-cooled single crystals of CZTSe. The extent of disorder was characterized by Raman spectroscopy as well as x-ray diffraction, where the change in Cu-Zn order can be detected by a changing c/a ratio. Quenched samples show higher acceptor concentrations, lower hole mobilities, and a lower-energy photoluminescence (PL) peak than crystals cooled at slower rates, consistent with a reduction in the bandgap. In addition, samples quenched at the highest temperatures showed lower PL yield consistent with higher quantities of deep defects. Devices fabricated using slow-cooled CZTSe single crystals showed improved efficiencies, most notably with increased V OC ; however, low temperature intensity-dependent photoluminescence measurements continue to indicate the existence of potential fluctuations. We discuss the possibility that potential fluctuations in slow-cooled samples may be related to the inability to achieve a long range order of the Cu-Zn sub-lattice resulting in local regions of high and low levels of cation order, and consequent local variations in the bandgap. Finally, the presence of significant potential fluctuations, even after the slow-cooling step, suggests the difficulty in eliminating band-tailing in this system, and thus, additional approaches may be needed for significant reduction of the V OC deficit.

36 MATERIALS SCIENCE↗

Apparatus and procedure to characterize the surface quality of conductors by measuring the rate of cathode emission as a function of surface electric field strength

A device and method for characterizing quality of a conducting surface. The device including a gaseous ionizing chamber having centrally located inside the chamber a conducting sample to be tested to which a negative potential is applied, a plurality of anode or "sense" wires spaced regularly about the central test wire, a plurality of "field wires" at a negative potential are spaced regularly around the sense, and a plurality of "guard wires" at a positive potential are spaced regularly around the field wires in the chamber. The method utilizing the device to measure emission currents from the conductor.

25 ENERGY STORAGE↗

Design and optimization of arrays of neodymium iron boron-based magnets for magnetic tweezers applications

We present the design methodology for arrays of neodymium iron boron (NdFeB)-based magnets for use in magnetic tweezers devices. Using finite element analysis (FEA), we optimized the geometry of the NdFeB magnet as well as the geometry of iron yokes designed to focus the magnetic fields toward the sample plane. Together, the magnets and yokes form a magnetic array which is the basis of the magnetic tweezers device. By systematically varying 15 distinct shape parameters, we determined those features that maximize the magnitude of the magnetic field gradient as well as the length scale over which the magnetic force operates. Additionally, we demonstrated that magnetic saturation of the yoke material leads to intrinsic limitations in any geometric design. Using this approach, we generated a compact and light-weight magnetic tweezers device that produces a high field gradient at the image plane in order to apply large forces to magnetic beads. We then fabricated the optimized yoke and validated the FEA by experimentally mapping the magnetic field of the device. The optimization data and iterative FEA approach outlined here will enable the streamlined design and construction of specialized instrumentation for force-sensitive microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ temperature-controllable shear flow device for neutron scattering measurement—An example of aligned bicellar mixtures

We have designed and constructed a temperature-controllable shear flow cell for in-situ study on flow alignable systems. The device has been tested in the neutron diffraction and has the potential to be applied in the small angle neutron scattering configuration to characterize the nanostructures of the materials under flow. The required sample amount is as small as 1 ml. The shear rate on the sample is controlled by the flow rate produced by an external pump and can potentially vary from 0.11 to 3.8 × 10{sup 5} s{sup −1}. Both unidirectional and oscillational flows are achievable by the setting of the pump. The instrument is validated by using a lipid bicellar mixture, which yields non-alignable nanodisc-like bicelles at low T and shear-alignable membranes at high T. Using the shear cell, the bicellar membranes can be aligned at 31 °C under the flow with a shear rate of 11.11 s{sup −1}. Multiple high-order Bragg peaks are observed and the full width at half maximum of the “rocking curve” around the Bragg’s condition is found to be 3.5°–4.1°. It is noteworthy that a portion of the membranes remains aligned even after the flow stops. Detailed and comprehensive intensity correction for the rocking curve has been derived based on the finite rectangular sample geometry and the absorption of the neutrons as a function of sample angle [See supplementary material at http://dx.doi.org/10.1063/1.4908165 for the detailed derivation of the absorption correction]. The device offers a new capability to study the conformational or orientational anisotropy of the solvated macromolecules or aggregates induced by the hydrodynamic interaction in a flow field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contactless excitation of acoustic resonance in insulating wafers

Contactless excitation and detection of high harmonic acoustic overtones in a thin insulator single crystal are described using radio frequency spectroscopy techniques. Single crystal [001] silicon wafer samples were investigated, one side covered with a Nb thin film, the common starting point for the fabrication of quantum devices. Additionally, the coupling between electromagnetic signals and mechanical oscillation is achieved from the Lorentz force generated by an external magnetic field. This method is suitable for any sample with a metallic surface or covered with a thin metal film. High resolution measurements of the temperature dependence of the sound velocity and elastic constants of silicon are reported and compared with known results.

47 OTHER INSTRUMENTATION↗

Experimental realization of classical Z 2 spin liquids in a programmable quantum device

We build and probe a Z 2 spin liquid in a programmable quantum device, the D-Wave DW-2000Q. Specifically, we observe the classical eight-vertex and six-vertex (spin ice) states and transitions between them. To realize this state of matter, we design a Hamiltonian with combinatorial gauge symmetry using only pairwise-qubit interactions and a transverse field, i.e., interactions which are accessible in this quantum device. The combinatorial gauge symmetry remains exact along the full quantum annealing path, landing the system onto the classical eight-vertex model at the endpoint of the path. The output configurations from the device allow us to directly observe the loop structure of the classical model. Moreover, we deform the Hamiltonian so as to vary the weights of the eight vertices and show that we can selectively attain the classical six-vertex (ice) model, or drive the system into a ferromagnetic state. Additionally, we present studies of the classical phase diagram of the system as a function of the eight-vertex deformations and effective temperature, which we control by varying the relative strengths of the programmable couplings, and we show that the experimental results are consistent with theoretical analysis. Finally, we identify additional capabilities that, if added to these devices, would allow us to realize Z 2 quantum spin liquids on which to build topological qubits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ analysis of texture development from sinusoidal stress at high pressure and temperature

Here, we present a new experimental protocol to investigate the relationship between texture, plastic strain, and the mechanisms of plastic deformation at high pressure and temperature. The method utilizes synchrotron X-ray radiation as the probing tool, coupled with a large-volume high pressure deformation device (D-DIA). The intensity of X-ray diffraction peaks within the spectrum of the sample is used for sampling texture development in situ. The unique feature of this study is given by the sinusoidal variation of the intensity when a sinusoidal strain is applied to the sample. For a sample of magnesium oxide at elevated pressure and temperature, we demonstrate observations that are consistent with elasto-plastic models for texture development and for diffraction-peak measurements of apparent stress. The sinusoidal strain magnitude was 3%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D Printing of Functional Hydrogel Devices for Screenings of Membrane Permeability and Selectivity

Developing a fundamental understanding of the effects of varying ligand chemistries on mass transport rates is key to designing membranes with solute-specific selectivity. While permeation cells offer a robust method to characterize membrane performance, they are limited to assessing a single membrane chemistry or salt solution per test. As a result, investigating the effects of varying ligand chemistries on membrane performance can be a tedious process, involving both the preparation of multiple samples and numerous, time-consuming permeation tests. This study uses digital light processing (DLP) 3D printing to fabricate a millifluidic flow-based permeation device made from a hydrogel active ester network that can be easily functionalized with ion-selective ligands. Without the need for bonding or assembly steps, ligands can be introduced and tested in the permeation device by simply injecting a small volume of a ligand solution. Various salt concentrations and molecular species can be cycled through a single device by switching the solution feeding into the salt reservoir, thereby reducing the number of samples needed for permeability and selectivity screenings. This research sets the groundwork for formulation development and postprocessing methods to 3D-print functional millifluidic devices capable of assessing solute selectivity in membranes and polymer adsorbents for aqueous separations. In this work, comparable salt permeability trends were observed with both 3D-printed devices and traditional assays. Devices were functionalized with an imidazole ligand to investigate salt permeability and selectivity of monovalent and divalent salts. Measurements showed increasing permeability for monovalent salts (NaCl) relative to divalent salts (MgCl 2 , CuCl 2 ) in functionalized membranes, with higher monovalent/divalent selectivity at increasing imidazole grafting densities. Here, the methods and findings described here represent a step toward developing higher-throughput methods with 3D-printed devices for screening the effects of ligand chemistry on mass transport rates in membrane materials.

36 MATERIALS SCIENCE↗

In situ Stripline Electrochemical NMR for Batteries

Here, there exist some long outstanding technical challenges that continue to be of hindrance to fully harnessing the unique investigative advantages of nuclear magnetic resonance (NMR) spectroscopy in the in situ investigation of rechargeable battery chemistry. For instance, the conducting materials and circuitry necessary for an operational battery always deteriorate the coil–based NMR sensitivity when placed inside the coil, and the shape mismatch between them leads to low sample filling factors and even higher detection limits. We report herein a novel and successful adaptation of stripline NMR detection that integrates seamlessly the NMR detection with construction of an electro–chemical device in general (or a battery in particular) which leads to a technique with much higher detection sensitivity, higher sample filling factors, and which is particularly suitable for mass–limited samples.

25 ENERGY STORAGE↗

HPCAT: A Static Compression Science Sector at the Advance Photon Source

Static compression is a useful tool to investigate the materials properties and phase behavior both under uniaxial stress and hydrostatic pressure. From evaluation of the equation of state (P-V-T relationship) to a discovery of near-room temperature superconductivity, the use of diamond anvil cells (DAC) and large-volume presses (LVP) as devices for static compression experiments that couple with synchrotron-based x-ray diffraction, spectroscopy, and imaging techniques achieved pioneering, paradigm defining scientific advancements in multidisciplinary fields for the past two decades. High-Pressure Collaborative Access Team (HPCAT) is a sector at the Advanced Photon Source dedicated to developing multiple synchrotron-based x-ray techniques to maximize the utility of DAC and portable-LVP techniques to advance compression science. The beamlines are optimized to adapt various sample environments under extreme P-T conditions. HPCAT is comprised of two insertion device beamlines, one for diffraction and the other for spectroscopy, and two bending magnet beamlines, one for general purpose and the other for white-beam application, respectively. As a result, each beamline’s specification and applications are introduced.

36 MATERIALS SCIENCE↗

To grind or not to grind? The influence of mechanical and thermal treatments on the $\mathrm{Cu/Zn}$ disorder in $\mathrm{Cu}$ 2 $\mathrm{ZnSn}$($\mathrm{S}$ x $\mathrm{Se}$ 1-x ) 4 monograins

We report that Kesterite-type based thin film solar cell technologies are mainly based on polycrystalline absorber layers. A promising low cost alternative technology uses Cu 2 ZnSn(S x Se 1-x ) 4 (CZTSSe) monograins (single crystals of 20–100 μm size) which are fixed in a polymer matrix to form a flexible solar cell. The Cu/Zn disorder is discussed as a possible reason for band tailing causing voltage losses limiting the efficiency of CZTSSe-based devices. The experimental determination of the order parameter Q which is a quantitative measure of Cu/Zn disorder, requires a differentiation between the isoelectronic cations Cu + and Zn 2+ . An in-depth analysis of neutron diffraction data allows the determination of type and concentration of intrinsic point defects including a distinction between Cu and Zn. Neutron diffraction requires large sample volumes, thus monograins offer the unique possibility to correlate structural disorder in CZTSSe with device performance parameters. In this study we tackle the influence of grinding the monograins on stoichiometry deviations, the Cu/Zn disorder as well as intrinsic point defects and optoelectronic properties of CZTSSe monograins. Moreover, an easy methodology based on Raman scattering spectroscopy is proposed for the assessment of Cu/Zn disorder in the CZTSSe compounds.

14 SOLAR ENERGY↗

Electron Spin Polarization in Large Electric Fields

This project investigated the effects of large electric fields on electron spin polarization in semiconductors, which is of interest for spin-based electronics (“spintronics”) and quantum information processing. It has been theoretically proposed that large electric fields could potentially preserve or amplify electron spin polarization, which would make it easier to generate, transport, and detect spin polarization in spin-based devices; however, previous measurements had not measured the response of electron spin polarization at large electric fields. During this project, methods to perform measurements of electron spin polarization at large electric fields were developed and performed using ultrafast time- and spatially-resolved magneto-optical spectroscopy, high-voltage pulses, and lock-in detection. The device geometry was engineered to reduce the threshold voltage required to reach the Gunn threshold, and the effect of optical illumination on the sample conductivity and Gunn oscillations was investigated. Electron spin polarization measurements were performed at electric fields up to and beyond the Gunn threshold for the device. The measurements showed that the electron spin polarization magnitude decreased with increasing electric field in the devices measured, and a spin amplification effect was not observed. However, these effects could potentially exist in a different material or in a material with a different doping concentration or in a different device geometry.

36 MATERIALS SCIENCE↗

Advances in Spectro‐Microscopy Methods and their Applications in the Characterization of Perovskite Materials

Perovskite materials are promising contenders as the active layer in light-harvesting and light-emitting applications if their long-term stability can be sufficiently increased. Chemical and structural engineering are shown to enhance long-term stability, but the increased complexity of the material system also leads to inhomogeneous functional properties across various length scales. Thus, scanning probe and high-resolution microscopy characterization techniques are needed to reveal the role of local defects and the results promise to act as the foundation for future device improvements. Here, a look at the parameter space: technique-specific sample penetration depth versus probe size highlights a gap in current methods. High spatial resolution combined with a deep penetration depth is not yet achievable. However, multimodal measurement technique may be the key to covering this parameter space. In this perspective, current advanced spectro-microscopy methods which have been applied to perovskite materials are highlighted.

Luo, Yanqi↗

Microstructure, magnetic and microwave absorptive behavior of doped W-type hexaferrite nanoparticles prepared by co-precipitation method

Highlights: • High frequency properties of substituted W-type Sr-hexaferrite. • Saturation magnetization of samples is decreased with increasing of dopants content. • The ferrite sample covers about 6 GHz of bandwidth in K{sub u} band. • The optimum substituted samples can be used as a potential magnetic loss material. • Sample contain x = 0.4 of dopants have shown greater than 90% of reflection loss. - Abstract: Substituted W-type hexaferrite nanoparticles of SrZn{sub 2−x}Co{sub x/2}Ni{sub x/2}Fe{sub 16}O{sub 27} were synthesized by a chemical co-precipitation method. The X-ray diffraction results confirmed that W-type ferrite was identified as the main phase in whole samples in the range of x = 0–0.4. According to magnetic hysteresis loops, with increasing of substituted cations, saturation of magnetization increased and coercivity decreased due to crystalline site occupation of Zn with Ni and Co cations. The microwave reflection loss analysis results in the K{sub u} band (12–18 GHz) show that the highest value of reflection loss of samples was −29.11 dB at frequency of 14.57 GHz with an absorption bandwidth of more than 6 GHz by choosing reflection loss value of −10 dB as a reference. The results indicate that, the sample with appropriate amount of substituted cations hold great promise for microwave device applications.

36 MATERIALS SCIENCE↗