Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Dielectric and ferroelectric properties of Pb{sub 0.88}La{sub 0.12}(Ti{sub 1−x}Mn{sub x}){sub 0.97}O{sub 3} nanoceramics

Graphical abstract: - Highlights: • The nanoceramics of La/Mn modified PbTiO{sub 3} are synthesized by mechano-thermal route. • Materials have been characterized using various experimental methods. • Drastic change in dielectric and electrical properties of PbTiO{sub 3} has been observed. • The high dielectric constant makes the material very promising candidate for DRAM. • The Mn substitution also makes the material useful for piezoelectric devices. - Abstract: The polycrystalline samples of Pb{sub 0.88}La{sub 0.12}(Ti{sub 1−x}Mn{sub x}){sub 0.97}O{sub 3} (x = 0.0, 0.04, 0.07, 0.10) (PLMT) were prepared using a mechano-thermal method. Preliminary structural analysis of the above samples, carried out using X-ray diffraction data, shows tetragonal structure. This study also shows that the basic compound PLT (Pb{sub 0.88}La{sub 0.12}TiO{sub 3}) retains its tetragonal structure even up to 10% of Mn substitution at the Ti-site. The transmission electron micrographs (TEM) of PLMT samples exhibit that materials prepared by the above method are found to be of nano-size. The temperature–frequency dependence of dielectric studies exhibits increase in relative permittivity with rise in Mn-concentration in PLMT, and hence it can make the materials useful for device applications. The temperature dependence of ac conductivity shows presence of different types of charge species. It is also observed that oxygen vacancies play a significant role in the high-temperature conduction-mechanism and dynamics of polarization of the system. Piezoelectric charge coefficient (d{sub 33}) increases with increase in the Mn content in PLMT.

36 MATERIALS SCIENCE↗

A power compensated differential scanning calorimeter for protein stability characterization

This study presented a power compensated MEMS differential scanning calorimeter (DSC) for protein stability characterization. In this microfabricated sensor, PDMS (Polydimethylsiloxane) and polyimide were used to construct the adiabatic chamber (1 μL) and temperature sensitive vanadium oxide was used as the thermistor material. A power compensation system was implemented to maintain the sample and reference at the same temperature. The resolution study and step response characterization indicated the high sensitivity (6 V/W) and low noise level (60 μk) of the device. The test with IgG1 antibody (mAb1) samples showed clear phase transitions and the data was confirmed to be reasonable by comparing it with the results of commercial DSC’s test. Finally, this device used ~1uL sample amount and could complete the scanning process in 4 min, significantly increasing the throughput of the bimolecular thermodynamics study like drug formulation process.

36 MATERIALS SCIENCE↗

Random Dopant Induced Threshold Voltage Lowering and Fluctuations in Sub 50 nm MOSFETs: a Statistical 3D 'Atomistic' Simulation Study

A 3D 'atomistic' simulation study of random dopant induced threshold voltage fluctuations and lowering in sub 50 nm MOSFETs is presented. The attention is focused mainly on devices with 30 nm effective channel length which represent the expected level of scaling at the end of the Silicon Roadmap. An efficient algorithm, based on a single 3D ap solution of the Poisson equation and a simplified current continuity equation, is used in the simulations. Large samples of microscopically different devices (typically 200) arc used in order to obtain statistically reliable results. The influence of different aspects of the conventional MOSFET design on the threshold voltage fluctuations and lowering are investigated. Results for fluctuation resistant device architectures based on low-doped epitaxial channel MOSFETs are also presented.

Asenov, Asen↗

Low temperature tunneling magnetoresistance on (La,Sr)MnO{sub 3}/Co junctions with organic spacer layers

This paper concerns with giant magnetoresistance (MR) effects in organic spin valves, which are realized as layered (La,Sr)MnO{sub 3} (LSMO)-based junctions with tris-(8, hydroxyquinoline) aluminum (Alq{sub 3})-spacer and ferromagnetic top layers. The experimental work was focused on the understanding of the transport behavior in this type of magnetic switching elements. The device preparation was carried out in an ultrahigh vacuum chamber equipped with a mask changer by evaporation and sputtering on SrTiO{sub 3} substrates with LSMO stripes deposited by pulsed laser technique. The field and temperature dependences of the MR of the prepared elements are studied. Spin-valve effects at 4.2 K have been observed in a broad resistance interval from 50 {omega} to M{omega} range, however, without systematic dependence on spacer layer thickness and device area. In some samples, the MR changes sign as a function of the bias voltage. The observed similarity in the bias voltages dependences of the MR in comparison with conventional magnetic tunnel junctions with oxide barriers suggests a description of the found effects within the classical tunneling concept. This assumption is also confirmed by a similar switching behavior observed on ferromagnetically contacted carbon nanotube devices. The proposed model implies the realization of the transport via local Co chains embedded in the Alq{sub 3} layer and spin dependent tunneling over barriers at the interface Co grains/Alq{sub 3}/LSMO. The existence of conducting Co chains within the organics is supported by transmission electron microscopic/electron energy loss spectroscopic studies on cross-sectional samples from analogous layer stacks.

36 MATERIALS SCIENCE↗

Design of dynamic hohlraum opacity samples to increase measured sample density on Z.

We are attempting to measure the transmission of iron on Z at plasma temperatures and densities relevant to the solar radiation and convection zone boundary. The opacity data published by us to date has been taken at an electron density about a factor of 10 below the 9 x 10{sup 22}/cm{sup 3} electron density of this boundary. We present results of two-dimensional (2D) simulations of the heating and expansion of an opacity sample driven by the dynamic Hohlraum radiation source on Z. The aim of the simulations is to design foil samples that provide opacity data at increased density. The inputs or source terms for the simulations are spatially and temporally varying radiation temperatures with a Lambertian angular distribution. These temperature profiles were inferred on Z with on-axis time-resolved pinhole cameras, x-ray diodes, and bolometers. A typical sample is 0.3{micro}m of magnesium and 0.078{micro}m of iron sandwiched between 10{micro}m layers of plastic. The 2D LASNEX simulations indicate that to increase the density of the sample one should increase the thickness of the plastic backing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatially resolved imaging of opto-electrical property variations

Systems and methods for opto electric properties are provided. A light source illuminates a sample. A reference detector senses light from the light source. A sample detector receives light from the sample. A positioning fixture allows for relative positioning of the sample or the light source with respect to each other. An electrical signal device measures the electrical properties of the sample. The reference detector, sample detector and electrical signal device provide information that may be processed to determine opto-electric properties of the same.

47 OTHER INSTRUMENTATION↗

A Hyphenated Preconcentrator-Infrared-Hollow-Waveguide Sensor System for N 2 O Sensing

Following the Kyoto protocol, all signatory countries must provide an annual inventory of greenhouse-gas emission including N 2 O. This fact associated with the wide variety of sources for N 2 O emissions requires appropriate sensor technologies facilitating in-situ monitoring, compact dimensions, ease of operation, and sufficient sensitivity for addressing such emission scenarios. In this contribution, we therefore describe an innovative portable mid-infrared chemical sensor system for quantifying gaseous N 2 O via coupling a substrate-integrated hollow waveguide (iHWG) simultaneously serving as highly miniaturized mid-infrared photon conduit and gas cell to a custom-made preconcentrator. N 2 O was collected onto a solid sorbent material packed into the preconcentrator unit, and then released via thermal desorption into the iHWG-MIR sensor utilizing a compact Fourier transform infrared (FTIR) spectrometer for molecularly selective spectroscopic detection with a limit of detection (LOD) at 5 ppbv. Highlighting the device flexibility in terms of sampling time, flow-rate, and iHWG design facilitates tailoring the developed preconcentrator-iHWG device towards a wide variety of application scenarios ranging from soil and aquatic emission monitoring and drone- or unmanned aerial vehicle (UAV)-mounted monitoring systems to clinical/medical analysis scenarios.

Science & Technology - Other Topics↗

Exploration of the Habitability of Mars with the SAM Suite Investigation on the 2009 Mars Science Laboratory

The 2009 Mars Science Laboratory (MSL) with a substantially larger payload capability that any other Mars rover, to date, is designed to quantitatively assess a local region on Mars as a potential habitat for present or past life. Its goals are (1) to assess past or present biological potential of a target environment, (2) to characterize geology and geochemistry at the MSL landing site, and (3) to investigate planetary processes that influence habitability. The Sample Analysis at Mars (SAM) Suite, in its final stages of integration and test, enables a sensitive search for organic molecules and chemical and isotopic analysis of martian volatiles. MSL contact and remote surface and subsurface survey Instruments establish context for these measurements and facilitate sample identification and selection. The SAM instruments are a gas chromatograph (GC), a mass spectrometer (MS), and a tunable laser spectrometer (TLS). These together with supporting sample manipulation and gas processing devices are designed to analyze either the atmospheric composition or gases extracted from solid phase samples such as rocks and fines. For example, one of the core SAM experiment sequences heats a small powdered sample of a Mars rock or soil from ambient to -1300 K in a controlled manner while continuously monitoring evolved gases. This is followed by GCMS analysis of released organics. The general chemical survey is complemented by a specific search for molecular classes that may be relevant to life including atmospheric methane and its carbon isotope with the TLS and biomarkers with the GCMS.

Mahaffy, P. R.↗

Sampling and Control Circuit Board for an Inertial Measurement Unit

A circuit board that serves as a control and sampling interface to an inertial measurement unit ("IMU") is provided. The circuit board is also configured to interface with a local oscillator and an external trigger pulse. The circuit board is further configured to receive the external trigger pulse from an external source that time aligns the local oscillator and initiates sampling of the inertial measurement device for data at precise time intervals based on pulses from the local oscillator. The sampled data may be synchronized by the circuit board with other sensors of a navigation system via the trigger pulse.

Chelmins, David T↗

Transmission electron microscopy characterization of electrically stressed AlGaN/GaN high electron mobility transistor devices

A set of AlGaN/GaN high electron mobility transistor devices has been investigated using step-stress testing, and representative samples of undegraded, source-side-degraded, and drain-side-degraded devices were examined using electron microscopy and microanalysis. An unstressed reference sample was also examined. All tested devices and their corresponding transmission electron microscopy samples originated from the same wafer and thus received nominally identical processing. Step-stressing was performed on each device and the corresponding current voltage characteristics were generated. Degradation in electrical performance, specifically greatly increased gate leakage current, was shown to be correlated with the presence of crystal defects near the gate edges. However, the drain-side-degraded device showed a surface pit on the source side, and another region of the same device showed no evidence of damage. Moreover, significant metal diffusion into the barrier layer from the gate contacts was also observed, as well as thin amorphous oxide layers below the gate metal contacts, even in the unstressed sample. Overall, these observations emphasize that gate-edge defects provide only a partial explanation for device failure.

Johnson, Michael↗

Locating the electrical junctions in Cu(In,Ga)Se 2 and Cu 2 ZnSnSe 4 solar cells by scanning capacitance spectroscopy

Here, we determined the electrical junction (EJ) locations in Cu(In,Ga)Se 2 (CIGS) and Cu 2 ZnSnSe 4 (CZTS) solar cells with ~20-nm accuracy by developing scanning capacitance spectroscopy (SCS) applicable to the thin-film devices. Cross-sectional sample preparation for the SCS measurement was developed by high-energy ion milling at room temperature for polishing the cross section to make it flat, followed by low-energy ion milling at liquid nitrogen temperature for removing the damaged layer and subsequent annealing for growing a native oxide layer. The SCS shows distinct p-type, transitional, and n-type spectra across the devices, and the spectral features change rapidly with location in the depletion region, which results in determining the EJ with ~20-nm resolution. We found an n-type CIGS in the region next to the CIGS/CdS interface; thus, the cell is a homojunction. The EJ is ~40 nm from the interface on the CIGS side. In contrast, such an n-type CZTS was not found in the CZTS/CdS cells. The EJ is ~20 nm from the CZTS/CdS interface, which is consistent with asymmetrical carrier concentrations of the p-CZTS and n-CdS in a heterojunction cell. Our results of unambiguously determination of the junction locations contribute significantly to understanding the large open-circuit voltage difference between CIGS and CZTS.

14 SOLAR ENERGY↗

Crystallographic and magnetic identification of secondary phase in orientated Bi{sub 5}Fe{sub 0.5}Co{sub 0.5}Ti{sub 3}O{sub 15} ceramics

The fabrication of highly-oriented polycrystalline ceramics of Bi{sub 5}Fe{sub 0.5}Co{sub 0.5}Ti{sub 3}O{sub 15}, prepared via molten salt synthesis and uniaxial pressing of high aspect ratio platelets is reported. Electron backscatter images show a secondary phase within the ceramic which is rich in cobalt and iron. The concentration of the secondary phase obtained from scanning electron microscopy is estimated at less than 2% by volume, below the detection limit of x-ray diffraction (XRD). The samples were characterized by x-ray diffraction, polarization-electric field measurements, superconducting quantum interference device as a function of sample orientation and vibrating sample magnetometry as a function of temperature. It is inferred from the data that the observed ferromagnetic response is dominated by the secondary phase. This work highlights the importance of rigorous materials characterisation in the study of multiferroics as small amounts of secondary phase, below the limit of XRD, can lead to false conclusions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.↗

Improved Bacterial and Viral Recoveries from 'Complex' Samples using Electrophoretically Assisted Acoustic Focusing

Automated front-end sample preparation technologies can significantly enhance the sensitivity and reliability of biodetection assays [1]. We are developing advanced sample preparation technologies for biowarfare detection and medical point-of-care diagnostics using microfluidic systems with continuous sample processing capabilities. Here we report an electrophoretically assisted acoustic focusing technique to rapidly extract and enrich viral and bacterial loads from 'complex samples', applied in this case to human nasopharyngeal samples as well as simplified surrogates. The acoustic forces capture and remove large particles (> 2 {micro}m) such as host cells, debris, dust, and pollen from the sample. We simultaneously apply an electric field transverse to the flow direction to transport small ({le} 2 {micro}m), negatively-charged analytes into a separate purified recovery fluid using a modified H-filter configuration [Micronics US Patent 5,716,852]. Hunter and O'Brien combined transverse electrophoresis and acoustic focusing to measure the surface charge on large particles, [2] but to our knowledge, our work is the first demonstration combining these two techniques in a continuous flow device. Marina et al. demonstrated superimposed dielectrophoresis (DEP) and acoustic focusing for enhanced separations [3], but these devices have limited throughput due to the rapid decay of DEP forces. Both acoustic standing waves and electric fields exert significant forces over the entire fluid volume in microchannels, thus allowing channels with larger dimensions (> 100 {micro}m) and high throughputs (10-100 {micro}L/min) necessary to process real-world volumes (1 mL). Previous work demonstrated acoustic focusing of microbeads [4] and biological species [5] in various geometries. We experimentally characterized our device by determining the biological size-cutoff where acoustic radiation pressure forces no longer transport biological particles. Figure 1 shows images of E.Coli ({approx}1 {micro}m) and yeast ({approx}4-5 {micro}m) flowing in a microchannel (200 {micro}m deep, 500 {micro}m wide) at a flow rate of 10 {micro}L/min. The E.Coli does not focus in the acoustic field while the yeast focuses at the channel centerline. This result suggests the acoustic size-cutoff for biological particles in our device lies between 2 and 3 {micro}m. Transverse electrophoresis has been explored extensively in electric field flow fractionation [6] and isoelectric focusing devices [7]. We demonstrated transverse electrophoretic transport of a wide variety of negatively-charged species, including fluorophores, beads, viruses, E.Coli, and yeast. Figure 2 shows the electromigration of a fluorescently labeled RNA virus (MS2) from the lower half of the channel to the upper half region with continuous flow. We demonstrated the effectiveness of our electrophoretically assisted acoustic focusing device by separating virus-like particles (40 nm fluorescent beads, selected to aid in visualization) from a high background concentration of yeast contaminants (see Figure 3). Our device allows for the efficient recovery of virus into a pre-selected purified buffer while background contaminants are acoustically captured and removed. We also tested the device using clinical nasopharyngeal samples, both washes and lavages, and demonstrated removal of unknown particulates (>2 ?m size) from the sample. Our future research direction includes spiking known amounts of bacteria and viruses into clinical samples and performing quantitative off-chip analysis (real-time PCR and flow cytometry).

42 ENGINEERING↗

Quality Assurance methodology for the ATLAS Inner Tracker strip sensor production

The production of the strip sensors for the ATLAS Inner Tracker (ITk) will start in 2020. Nearly 22,000 large area sensors will be produced over a period of about five years by Hamamatsu Photonics K.K. (HPK). The institutes involved in the sensor development and production are committed to deliver and maintain the highest quality sensors for the experiment. A Quality Assurance (QA) strategy has been prepared to be carried out during the whole production period. Once the process has been characterized as providing the required pre-irradiation specifications and the proper radiation hardness, the onus is on the manufacturer to rigidly stick to that qualified process. Still, sample testing with specific device-element structures and irradiation of devices should be implemented by the ITk sensor collaboration. A detailed irradiation and testing plan has been prepared by the ATLAS-ITk Collaboration, together with a newly designed test chip with specific structures to monitor different key technological and device parameters during the whole production. The tests and irradiations will be carried out on a sample basis. In order to have a practical methodology, samples from alternating batches will be sent for irradiations with protons, neutrons and gammas, and then tested in order to check that the characteristics remain within specifications. Here we present the detailed plan and the design and test methods for the structures in the test chip.

47 OTHER INSTRUMENTATION↗

Soft inertial microfluidics for high throughput separation of bacteria from human blood cells

We developed a new approach to separate bacteria from human blood cells based on soft inertial force induced migration with flow defined curved and focused sample flow inside a microfluidic device. This approach relies on a combination of an asymmetrical sheath flow and proper channel geometry to generate a soft inertial force on the sample fluid in the curved and focused sample flow segment to deflect larger particles away while the smaller ones are kept on or near the original flow streamline. The curved and focused sample flow and inertial effect were visualized and verified using a fluorescent dye primed in the device. First the particle behavior was studied in detail using 9.9 and 1.0 {micro}m particles with a polymer-based prototype. The prototype device is compact with an active size of 3 mm{sup 2}. The soft inertial effect and deflection distance were proportional to the fluid Reynolds number (Re) and particle Reynolds number (Re{sub p}), respectively. We successfully demonstrated separation of bacteria (Escherichia coli) from human red blood cells at high cell concentrations (above 10{sup 8}/mL), using a sample flow rate of up to 18 {micro}L/min. This resulted in at least a 300-fold enrichment of bacteria at a wide range of flow rates with a controlled flow spreading. The separated cells were proven to be viable. Proteins from fractions before and after cell separation were analyzed by gel electrophoresis and staining to verify the removal of red blood cell proteins from the bacterial cell fraction. This novel microfluidic process is robust, reproducible, simple to perform, and has a high throughput compared to other cell sorting systems. Microfluidic systems based on these principles could easily be manufactured for clinical laboratory and biomedical applications.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Electronic Stress-Induced Changes in Multilayer MoS 2

Transition metal dichalcogenides like molybdenum disulfide (MoS 2 ) are compelling for next-generation electronic devices. In this work, we investigate the impact of electronic stress on MoS 2 to illustrate that observational and phenomenological information on multiple devices can be useful to describe changes in the device, and caution against the rationalization of paltry results as representative or correlative to device behavior. Here, we stress MoS 2 by applying a sustained 20 V DC bias to study the material’s response. Post-stress electronic characterization revealed nonuniform shifts in current–voltage (I–V) behavior alongside microscale changes. Complementary mechanical, spectroscopic, and scanning microwave impedance measurements showed that stress-induced features locally modulate stiffness, surface potential, Raman intensity, and charge carrier density. We correlated I–V behavior with morphological features (wrinkles, tears, folds, height) and device-level geometry (MoS 2 overlap with electrodes, channel area, contact length) on 50 test structures across five chips to move beyond anecdotal conclusions. We found no universal correlations before DC stress. However, device-level geometry was correlated with I–V behavior after DC stress, suggesting that electrode contacts play a more dominant role than morphology in determining performance. Delamination and thinning induced by DC stress led to localized reductions in charge carrier density within the affected regions. Further, delamination and thinning appear to map to I–V device performance in a few samples, but the correlation is lost when a larger sample size is considered. This suggests significant sample-to-sample variability in surface electronic states of the test structures. We also discuss how environmental factors introduced during fabrication may contribute to the observed heterogeneous device response. Progress will require high-resolution, multimodal analysis across many samples constructed under controlled, clean conditions. By building data sets that capture variability, we can better identify the true drivers of performance.

36 MATERIALS SCIENCE↗

Surface Contact Model for Comets and Asteroids

A contact force model was developed for use in touch and go (TAG) surface sampling simulations on small celestial bodies such as comets and asteroids. In TAG scenarios, a spacecraft descending toward the surface of a small body comes into contact with the surface for a short duration of time, collects material samples with a sampler device, and then ascends to leave the surface. The surface contact required 6-DOF (degrees of freedom) dynamics models due to coupling of the attitude and translation dynamics during the contact. The model described here is for contact scenarios that utilize a rotating brush wheel sampler (BWS) to collect surface material. The model includes stiffness and damping of the surface material during BWS vertical motion, lateral friction from the BWS dragging across the surface, and lateral shear from the rotating BWS scooping the surface material. This model is useful for any mission to asteroids or comets that incorporates surface sampling operations.

Blackmore, Lars James C.↗