Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE PREPARATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Electron Tomography of Cryo-Immobilized Plant Tissue: A Novel Approach to Studying 3D Macromolecular Architecture of Mature Plant Cell Walls In Situ

Cost-effective production of lignocellulosic biofuel requires efficient breakdown of cell walls present in plant biomass to retrieve the wall polysaccharides for fermentation. In-depth knowledge of plant cell wall composition is therefore essential for improving the fuel production process. The precise spatial three-dimensional (3D) organization of cellulose, hemicellulose, pectin and lignin within plant cell walls remains unclear to date since the microscopy techniques used so far have been limited to two-dimensional, topographic or low-resolution imaging, or required isolation or chemical extraction of the cell walls. In this paper we demonstrate that by cryo-immobilizing fresh tissue, then either cryo-sectioning or freeze-substituting and resin embedding, followed by cryo- or room temperature (RT) electron tomography, respectively, we can visualize previously unseen details of plant cell wall architecture in 3D, at macromolecular resolution (~2 nm), and in near-native state. Qualitative and quantitative analyses showed that wall organization of cryo-immobilized samples were preserved remarkably better than conventionally prepared samples that suffer substantial extraction. Lignin-less primary cell walls were well preserved in both self-pressurized rapidly frozen (SPRF), cryo-sectioned samples as well as high-pressure frozen, freeze-substituted and resin embedded (HPF-FS-resin) samples. Lignin-rich secondary cell walls appeared featureless in HPF-FS-resin sections presumably due to poor stain penetration, but their macromolecular features could be visualized in unprecedented details in our cryo-sections. While cryo-tomography of vitreous tissue sections is currently proving to be instrumental in developing 3D models of lignin-rich secondary cell walls, here we confirm that the technically easier method of RT-tomography of HPF-FS-resin sections could be used immediately for routine study of low-lignin cell walls. As a proof of principle, we characterized the primary cell walls of a mutant (cob-6) and wild type Arabidopsis hypocotyl parenchyma cells by RT-tomography of HPF-FS-resin sections, and detected a small but significant difference in spatial organization of cellulose microfibrils in the mutant walls.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of Tank 15H Sample in Support of Preliminary Cease Waste Removal and Closure Mode Determination

The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and analysis of Tank 15H characterization samples. These samples follow an interest in exploring avenues to condense the extensive sampling of the Tank Closure process. One such pathway would be to collect a sample during an earlier waste removal campaign for analysis to determine comparability to the later residual tank inventory determined through Residual Material sampling and characterization prior to grouting. Six Tank 15H samples (HTF-15-24-9, HTF- HTF-15-24-10, HTF-15-24-11, HTF-15-24-12, HTF15-24-13, and HTF-15-24-14) were delivered to SRNL in May of 2024. These six Tank 15H samples were taken as close as possible to the solids layer of the Tank 15H. These six Tank 15H samples were combined to form one composite sample for characterization due to the lack of sufficient solids fraction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aqueous nitrite ion determination by selective reduction and gas phase nitric oxide chemiluminescence

An improved method of flow injection analysis for aqueous nitrite ion exploits the sensitivity and selectivity of the nitric oxide (NO) chemilluminescence detector. Trace analysis of nitrite ion in a small sample (5-160 microL) is accomplished by conversion of nitrite ion to NO by aqueous iodide in acid. The resulting NO is transported to the gas phase through a semipermeable membrane and subsequently detected by monitoring the photoemission of the reaction between NO and ozone (O3). Chemiluminescence detection is selective for measurement of NO, and, since the detection occurs in the gas-phase, neither sample coloration nor turbidity interfere. The detection limit for a 100-microL sample is 0.04 ppb of nitrite ion. The precision at the 10 ppb level is 2% relative standard deviation, and 60-180 samples can be analyzed per hour. Samples of human saliva and food extracts were analyzed; the results from a standard colorimetric measurement are compared with those from the new chemiluminescence method in order to further validate the latter method. A high degree of selectivity is obtained due to the three discriminating steps in the process: (1) the nitrite ion to NO conversion conditions are virtually specific for nitrite ion, (2) only volatile products of the conversion will be swept to the gas phase (avoiding turbidity or color in spectrophotometric methods), and (3) the NO chemiluminescence detector selectively detects the emission from the NO + O3 reaction. The method is free of interferences, offers detection limits of low parts per billion of nitrite ion, and allows the analysis of up to 180 microL-sized samples per hour, with little sample preparation and no chromatographic separation. Much smaller samples can be analyzed by this method than in previously reported batch analysis methods, which typically require 5 mL or more of sample and often need chromatographic separations as well.

NASA Discipline Environmental Health↗

NM-Scale Anatomy of an Entire Stardust Carrot Track

Comet Wild-2 samples collected by NASA s Stardust mission are extremely complex, heterogeneous, and have experienced wide ranges of alteration during the capture process. There are two major types of track morphologies: "carrot" and "bulbous," that reflect different structural/compositional properties of the impactors. Carrot type tracks are typically produced by compact or single mineral grains which survive essentially intact as a single large terminal particle. Bulbous tracks are likely produced by fine-grained or organic-rich impactors [1]. Owing to their challenging nature and especially high value of Stardust samples, we have invested considerable effort in developing both sample preparation and analytical techniques tailored for Stardust sample analyses. Our report focuses on our systematic disassembly and coordinated analysis of Stardust carrot track #112 from the mm to nm-scale.

Nakamura-Messenger, K.↗

Plasma-Based Elemental Analyzer for Crewed Transit and Planetary Habitation

As NASA continues to perform research on the ISS and move towards the Moon and Mars, it is important for astronauts to have a technology capable of determining the composition of solid, liquid, and gas samples. Currently, samples are transported back to Earth for analysis, which may impact results due to the time delay of samples waiting to be returned to Earth as well as potential sample contamination from re-entry, change in environment, and various personnel handling. Therefore, researchers at the Applied Chemistry Lab at KSC have developed a proof-of-concept “Plasma-Based Elemental Analyzer,” which has the capability of testing solid, liquid, and gas samples for identification. Currently, the analysis is only qualitative, with quantitative identification left for future work. This technology is similar to ICP-OES, but differs in instrument size and sample preparation. Both technologies use plasma to ionize samples for light emission. The plasma elemental analyzer aims to be portable and lightweight, require only electrical power, and analyze solid, liquid, and gas samples. It does not use acid digestion or a nebulizer, requires less power than ICP-OES, and is able to operate with minimal to no usage of argon gas. Furthermore, the plasma elemental analyzer operates within low power constraints, which makes it feasible for usage on future missions with higher power constraints. The technology was tested at atmospheric pressure using mostly room air as the carrier gas for plasma production in the proof-of-concept study. The results showed the peak signals of the elements with an associated arbitrary signal intensity that allowed for qualitative identification. Solid samples that were tested included inedible biomass from the Golden Heirloom Cherry Tomato plant and Lunar Highlands Simulants (LHS-1). The liquid samples included elements of interest for the space crop production community. This work showed that a system smaller than the traditional ICP-OES equipment is able to be designed and implemented in future use cases, although it requires further development.

Kenneth Engeling↗

High temperature flow-through device for rapid solubilization and analysis

Devices and methods for thermally lysing of biological material, for example vegetative bacterial cells and bacterial spores, are provided. Hot solution methods for solubilizing bacterial spores are described. Systems for direct analysis are disclosed including thermal lysers coupled to sample preparation stations. Integrated systems capable of performing sample lysis, labeling and protein fingerprint analysis of biological material, for example, vegetative bacterial cells, bacterial spores and viruses are provided.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation and Interpretation of Properties for Saltstone Cores Extracted from an SDU - 17344

Extraction and subsequent analysis of emplaced saltstone samples from a Savannah River Site (SRS) Saltstone Disposal Unit (SDU) were performed in order to realize the following key objectives: (1) to support the use of historical and future laboratory-derived sample data to predict the behavior of field-emplaced samples, and (2) to substantiate the saltstone properties currently assumed in Saltstone Disposal Facility (SDF) transport modeling, i.e., Performance Assessment (PA) and Special Analyses (SA) models. Multiple cores were extracted via a wet core drilling process in April-May 2015 approximately 20 months after the saltstone of interest was processed in the Saltstone Production Facility (SPF) and subsequently emplaced in SDU Cell 2A (SDU2A). The retrieved samples were stored in an inert N{sub 2} environment prior to, and during, the property testing that took place between October 2015 and March 2016. Sample analyses comprised evaluation of physical properties (density, porosity, and moisture content), saturated hydraulic conductivity (K{sub sat}), and determination of distribution coefficients and solubilities for key radionuclides. In general the SDU2A samples indicated comparative properties to laboratory-prepared samples and additionally verified many of the inputs currently assumed in the SDF PA. The principal exception was related to the leaching characteristics of I-129, which demonstrated a lower than anticipated affinity for retention within the saltstone matrix. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Co{sub 2}FeAl based magnetic tunnel junctions with BaO and MgO/BaO barriers

We succeed to integrate BaO as a tunneling barrier into Co{sub 2}FeAl based magnetic tunnel junctions (MTJs). By means of Auger electron spectroscopy it could be proven that the applied annealing temperatures during BaO deposition and afterwards do not cause any diffusion of Ba neither into the lower Heusler compound lead nor into the upper Fe counter electrode. Nevertheless, a negative tunnel magnetoresistance (TMR) ratio of -10% is found for Co{sub 2}FeAl (24 nm) / BaO (5 nm) / Fe (7 nm) MTJs, which can be attributed to the preparation procedure and can be explained by the formation of Co- and Fe-oxides at the interfaces between the Heusler and the crystalline BaO barrier by comparing with theory. Although an amorphous structure of the BaO barrier seems to be confirmed by high-resolution transmission electron microscopy (TEM), it cannot entirely be ruled out that this is an artifact of TEM sample preparation due to the sensitivity of BaO to moisture. By replacing the BaO tunneling barrier with an MgO/BaO double layer barrier, the electric stability could effectively be increased by a factor of five. The resulting TMR effect is found to be about +20% at room temperature, although a fully antiparallel state has not been realized.

36 MATERIALS SCIENCE↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics FY2022 Project Report

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques. In this first year of the project, all uranium oxide samples were synthesized and characterized using conventional analyses by the analytical chemistry laboratory. Conventional analysis methods included powder x-ray diffraction, scanning electron microscopy, impurity analysis via inductively coupled plasma mass spectrometry, and infrared spectroscopy. Impurity analysis shows a drop in boron content from UO 3 to the lowest U 3 O 8 calcination temperature, but otherwise no appreciable difference in any sample. Analysis of diffraction data shows a flip of peaks from UO 3 dominated for the 600 °C calcined sample to U 3 O 8 dominated at 700 °C and 800 °C. Analysis of scanning electron microscopy images shows that with increased calcination temperature the size distribution of particles seems to increase and broaden. Both of these last findings are in line with previously published data, though this work used significantly fewer particles to simply show similar trends instead of getting truly quantitative particle analysis. Infrared analysis similarly shows ingrowth of U 3 O 8 as calcination temperature is increased, along with depression of peaks associated with UO 3 and water. Samples were prepared for analysis at the Advanced Photon Source at beamline 1-ID. It is anticipated that analysis will occur in November of 2022. AI/ML techniques to de-noise data coming out of 1-ID during the analyses was also developed during this time using previously gathered data. Preliminary results using a self-supervision technique called Noise2Selfshow good de-noising of data. Once the uranium oxide samples are analyzed, real data will be used to test the de-noising and other AI/ML techniques that may be developed in the second year of the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Yttrium Oxide Concentration Effect on Helium Porosity Formation in Oxide-Dispersion-Hardened Ferrite-Martensite Steel

Studies are presented of helium porosity in EP-450 oxide-dispersion-hardened yttrium steel, obtained by electopulse sintering, as a function of the Y{sub 2}O{sub 3} content in comparison with EP-450 matrix steel and dispersion-hardened steel fabricated by hot extrusion. It is found that multiple zones with different types of helium porosity and different zone distribution develop in steel with 1 wt.% Y{sub 2}O{sub 3}; in steel with 0.3 wt.% Y{sub 2}O{sub 3}, there are fewer such zones than in matrix steel and steel obtained by hot extrusion. It is proposed that the extremely nonuniform distribution of porosity over volume and size in steel fabricated by electropulse sintering is associated with the initially strongly defective structure, including residual porosity, as well as with the chromium redistribution between ferrite grains and tempered-martensite grains during the sample preparation process.

36 MATERIALS SCIENCE↗

Fast Decomposition of Three-Component Spectra of Fluorescence Quenching by White and Grey Methods of Data Modeling

‘White’ and ‘grey’ methods of data modeling have been employed to resolve the heterogeneous fluorescence from a fluorophore mixture of 9-cyanoanthracene (CNA), 10-chloro-9-cyanoanthracene (ClCNA) and 9,10-dicyanoanthracene (DCNA) into component individual fluorescence spectra. The three-component spectra of fluorescence quenching in methanol were recorded for increasing amounts of lithium bromide used as a quencher. The associated intensity decay profiles of differentially quenched fluorescence of single components were modeled on the basis of a linear Stern-Volmer plot. These profiles are necessary to initiate the fitting procedure in both ‘white’ and ‘grey’ modeling of the original data matrices. ‘White’ methods of data modeling, called also ‘hard’ methods, are based on chemical/physical laws expressed in terms of some well-known or generally accepted mathematical equations. The parameters of these models are not known and they are estimated by least squares curve fitting. ‘Grey’ approaches to data modeling, also known as hard-soft modeling techniques, make use of both hard-model and soft-model parts. In practice, the difference between ‘white’ and ‘grey’ methods lies in the way in which the ‘crude’ fluorescence intensity decays of the mixture components are estimated. In the former case they are given in a functional form while in the latter as digitized curves which, in general, can only be obtained by using dedicated techniques of factor analysis. In the paper, the initial values of the Stern-Volmer constants of pure components were evaluated by both ‘point-by-point’ and ‘matrix’ versions of the method making use of the concept of wavelength dependent intensity fractions as well as by the rank annihilation factor analysis applied to the data matrices of the difference fluorescence spectra constructed in two ways: from the spectra recorded for a few excitation lines at the same concentration of a fluorescence quencher or classically from a series of the spectra measured for one selected excitation line but for increasing concentration of the quencher. The results of multiple curve resolution obtained by all types of the applied methods have been scrutinized and compared. In addition, the effect of inadequacy of sample preparation and increasing instrumental noise on the shape of the resolved spectral profiles has been studied on several datasets mimicking the measured data matrices. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Atmospheric Solid Analysis Probe Coupled to Ion Mobility Spectrometry-Mass Spectrometry, a Fast and Simple Method for Polyalphaolefin Characterization

Polyalphaolefins (PAOs) are polymers produced from linear alpha olefins through catalytic oligomerization processes. The PAOs are known as synthetic high-performance base stock fluids used to improve the efficiency of many other synthetic products. In this study, we report the direct characterization of PAOs using atmospheric solid analysis probe (ASAP) coupled with ion mobility spectrometry-mass spectrometry (IMS-MS). We studied different PAOs grades exhibiting low- and high-viscosity index. Specific adjustments of the ASAP source parameters permitted the monitoring of ionization processes as three mechanisms could occur for these compounds: hydride abstraction, nitrogen addition, and/or the formation of [M−2H]{sup +•} ions. Several series of fragment ions were obtained, which allowed the identification of the alpha olefin used to synthesize the PAO. The use of the ion mobility separation dimension provides information on isomeric species. In addition, the drift time versus m/z plots permitted rapid comparison between PAO samples and to evidence their complexity. These 2D plots appear as fingerprints of PAO samples. To conclude, the resort to ASAP-IMS-MS provides a rapid characterization of the PAO samples in a direct analysis approach, without any sample preparation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural analysis of bioceramic materials for denture application

Structural analysis has been performed on bioceramic materials for denture application by using X-ray diffraction (XRD), X-ray fluorescence (XRF), and Scanning Electron Microscopy (SEM). XRF is using for analysis chemical composition of raw materials. XRF shows the ratio 1 : 1 : 1 : 1 between feldspar, quartz, kaolin and eggshell, respectively, resulting composition CaO content of 56.78 %, which is similar with natural tooth. Sample preparation was carried out on temperature of 800 °C, 900 °C and 1000 °C. X-ray diffraction result showed that the structure is crystalline with trigonal crystal system for SiO{sub 2} (a=b=4.9134 Å and c=5.4051 Å) and CaH{sub 2}O{sub 2} (a=b=3.5925 Å and c=4.9082 Å). Based on the Scherrer’s equation showed the crystallite size of the highest peak (SiO{sub 2}) increase with increasing the temperature preparation. The highest hardness value (87 kg/mm{sup 2}) and match with the standards of dentin hardness. The surface structure was observed by using SEM also discussed.

36 MATERIALS SCIENCE↗

Investigation of magnetic nanoparticles for the rapid extraction and assay of alpha-emitting radionuclides from urine: Demonstration of a novel radiobioassay method

In the event of an accidental or intentional release of radionuclides into a populated area, three things must occur in a timely manner: food and drinking water supplies must be determined to be safe to eat / drink, civilians and/or military personnel must be surveyed to ensure that they do not have external contamination, and they must be screened to ensure that significant ingestion or inhalation of radionuclides has not occurred (this paper is concerned with the latter). In the event of such a disaster, the volume of radiobioassays to be performed would be tremendous. If the event released significant levels of β- or α-emitting radionuclides, in vivo assays would be ineffective. Therefore, highly efficient and rapid analytical methods for radionuclide detection from submitted spot urine samples (≤ 50 mL) would be required. At present, the quantitative determination of α-emitting radionuclides from urine samples is highly labor intensive, and requires significant sample preparation and analysis time. Sorbent materials that provide effective collection and enable rapid assay could significantly streamline the radioanalytical process. We have demonstrated the use of paramagnetic nanoparticles as a novel class of extracting media for four α-emitting radionuclides of concern (Po, Ra, Am, and U) from chemically unmodified and pH 2 human urine. Herein the initial experimental sorption results are presented along with a novel method that utilizes paramagnetic nanoparticles for the extraction of radionuclides from unmodified human urine followed by the magnetic field-induced collection of the particles for subsequent α-counting-source preparation. Additionally, we construct a versatile human dose model that determines the detector count times required to estimate internal human dose at specific protective action thresholds. The model provides a means to assess a method’s detection capabilities and use fundamental health physics parameters and actual experimental data as core variables. The modeling shows that with effective sorbent materials, rapid screening for internalized α-emitters is possible from a 50 mL spot urine sample volume collected within one week of exposure/intake.

59 BASIC BIOLOGICAL SCIENCES↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

Ten years in the making the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center is designed to be a cooperative analytical facility where novel techniques are developed and performed. Our team works collaboratively to operate this integrated lab suite comprising sample preparation, metal-free clean chemistry, and mass spectrometers to measure a wide variety of elements and isotopes in astromaterials. Contamination control is enacted throughout by a positive pressure cascade of HEPA filtered air, weekly surface cleaning and particle counting. Astromaterials processing is performed with application-specific mortar and pestles, heavy liquid separation, a Frantz magnetic separator, as well as hand-picking using optical microscopes in laminar flow boxes. Microsampling is also carried out using a New Wave MicroMill. Elements for isotopic analysis are isolated from acid-digested samples using ion-exchange chromatography. Cross-contamination is minimized with dedicated laminar flow boxes and labware for different purification protocols. Instrumentation includes a ThermoFisher Element XR inductively coupled plasma mass spectrometer (ICP-MS) for quantification of elemental concentrations in dissolved sample solutions. For in situ analysis, a Teledyne Photon Machines Analyte Excite+ laser ablation system is coupled to the Element XR. The ThermoFisher Triton thermal ionization mass spectrometer (TIMS) is used to measure the isotopic composition of elements such as CA, K, Cr, Rb, Sr, Sm, Nd at high precision in processed samples. For a more diverse range of isotopic analyses, CICG houses a Nu Sapphire 1700 multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), which is a large geometry instrument with a multi-pole collision cell for interference removal. An Applied Spectra Instruments J200 femto-second laser is planned for install this Fall and will be coupled to the Nu Sapphire 1700. NASA’s Internal Scientist Funding Model (ISFM)supports this facility. Advanced analytical geochemistry techniques are applied to targeted astromaterials to address important problems in planetary sciences, with a longer-term goal of preparing for samples collected and returned by space missions. CICG is open to collaborations on projects that utilize the facility’s unique capabilities and are within its research scope. We are particularly eager to support and share expertise with the next generation of planetary scientists.

Justin I Simon↗

Comparison between IRMS and CRDS methods in the determination of isotopic ratios {sup 2}H/{sup 1}H and {sup 18}O/{sup 16}O in water

Traditionally, the method used for measuring the isotope ratios is the Isotope Ratio Mass Spectrometers (IRMS). A new method has been used to determine the isotopic abundances, the Cavity Ring-Down Spectroscopy (CRDS). It consists of a technique of direct absorption, of high sensitivity, which is based on measuring the absorption ratio, as a function of time, of the light confined in a high finesse optical cavity, instead of the magnitude of light beam absorption. The values of {sup 18}O/{sup 16}O and D/H ratios are determined with respect to international standards VSMOW, GISP and SLAP from the International Atomic Energy Agency (IAEA). In this work, the IRMS and CRDS techniques are compared, verifying that the CRDS technique is promising and has some advantages compared to IRMS. It uses a smaller amount of sample, the isotope measurements are made simultaneously from the steam, reducing the analysis time. It also shows good reproducibility and accuracy, and it does not require a preliminary sample preparation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EPR/PTFE dosimetry for test reactor environments

The use of Electron Paramagnetic Resonance (EPR) spectroscopy with materials such as alanine is well established as a technique for measurement of ionizing radiation absorbed dose in photon and electron fields such as Co-60, high-energy bremsstrahlung and electron-beam fields [1]. In fact, EPR/Alanine dosimetry has become a routine transfer standard for national standards bodies such as NIST and NPL. In 1992 the Radiation Metrology Laboratory (RML) at Sandia National Laboratories implemented EPR/Alanine capabilities for use in routine and calibration activities at its Co-60 and pulsed-power facilities. At that time it also investigated the usefulness of the system for measurement of absorbed dose in the mixed neutron/photon environments of reactors such as the Sandia Pulsed Reactor and the Annular Core Research Reactor used for hardness testing of electronics. The RML concluded that the neutron response of alanine was a sufficiently high fraction of the overall dosimeter response that the resulting uncertainties in the photon dose would be unacceptably large for silicon-device testing. However, it also suggested that non-hydrogenous materials such as polytetrafluoroethylene (PTFE) would exhibit smaller neutron response and might be useful in mixed environments. Preliminary research with PTFE in photon environments indicated considerable promise, but further development was not pursued at that time. Because of renewed interest in absorbed dose measurements that could better define the individual contributions of photon and neutron components to the overall dose delivered to a test object, the RML has re-initiated the development of an EPR/PTFE dosimetry system. This effort consists of three stages: 1) Identification of PTFE materials that may be suitable for dosimetry applications. It was speculated that the inconsistency of EPR signatures in the earlier samples may have been due to variability in PTFE manufacturing processes. 2) Characterization of dosimetry in photon-only environments. This is necessary to establish requirements for sample preparation, operating parameters and limitations for use in well-defined and predictable environments prior to deployment in the less well-defined mixed environments of test reactors. 3) Characterization of the EPR responses obtained with PTFE in mixed neutron/photon fields. This includes evaluation of the neutron and photon contributions to response, determination of applicable of neutron fluence and photon dose ranges. This paper presents a summary of the research, a description of the EPR/PTFE dosimetry system, and recommendations for preparation and fielding of the dosimetry in photon and mixed neutron/photon environments. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Effect of Vacuum on Force Response of an Ultrasonic Penetrator

Introduction: The Apollo astronauts encountered higher than expected resistances when interacting with the lunar soil via the Apollo Lunar Surface Drill (ALSD) and the trenching tool. Reducing the force required to move tools or other mechanical components through regolith will impact many steps of the resource extraction process. Force reduction has been achieved in soil materials by imparting vibration to tooling interfaces such as a vibratory farming cultivator, a percussive scoop, and ultrasonically resonant penetrators. Vibration-assisted tools in granular media reduce interaction forces by fluidizing a volume around the tool, allowing the tool to progress through a dynamic (fluid) medium instead of a static (solid) medium. This work seeks to quantify ultrasonic vibration’s effect on the force response of a penetrator in lunar soil simulant in vacuum sufficient to be within the molecular flow regime of any disturbed gases. Methods: A custom vacuum chamber setup, CUBEvac, was designed and built to facilitate penetration testing in a high vacuum environment, for comparison to penetration behavior in ambient terrestrial environment. A two-stage pumping system (Agilent Triscroll 600 roughing pump, Agilent VHS-6 oil diffusion pump) reached chamber pressures of about 5x10-6 Torr with regolith simulant in place. Figure 1 is a schematic of the heart of the assembly (note the penetration drive mechanisms above the chamber feedthrough and the regolith simulant sample in the bottom are not shown). The penetration actuation stack was comprised of a stepper motor driving a lead screw to move the ultra-sonic probe vertically inside the chamber. Motion was coordinated with an Arduino Uno. GRC-3 lunar simulant was used for this set of experiments. Samples were prepared in a four-liter stain-less steel, cylindrical pot with an internal diameter of approximately 15.56 cm (6.125 in) and a depth of 19.37 cm (7 5/8 in) for testing. The soil was baked out prior to compaction preparation as a measure to reduce soil moisture which interfered with pump down capacity. The soil was not baked again if it was removed from the vacuum chamber, prepped, and immediately returned to the vacuum chamber for pump down. The soil was compacted using a 60 Hz vibration table with a surcharge of 34 kg place on top of the soil in the container. Prepared soil samples weighed approximately 6.5 kg (bulk density 1.895-1.934 g/cm3). Two probe end effectors were tested: A cone penetrometer (static only) with a nominal diameter of 12.7 mm (0.5 in) and a nominal height of 28.6 mm (1.125 in); and a vibrating cylindrical probe measuring 12.7 mm in diameter and 50.8 mm in effective length from the tip (Figure 2). The cylindrical probe vibrated resonantly at 20 kHz with an amplitude 23 μm. The cone penetration tests were conducted to assess potential soil behavior differences in vacuum. The cylinder probe tests were conducted as the primary subject of this investigation to assess force response in vacuum. For each test, a regolith simulant sample was load-ed and compacted in the chamber, which was then evacuated for roughly 18 hours to reach the lowest possible pressure (approximately 5x10-6 Torr for most tests). The probe was then moved to about 10 mm above the soil surface before being pushed to a depth of 50 mm for the cylinder probe tests and to a depth of 100 mm for the cone penetrometer tests, both at a speed of 2 mm/s. The simulant samples were prepared the same for all tests. Ideally, they would respond consistently to probe penetration under ambient and vacuum conditions. This was evaluated by measuring the resistance of representative prepared simulant beds with a standard cone penetrometer in both environments. Results and Discussion: The resistance of the simulant samples in the vacuum tests was consistently lower than in the ambient tests as determined by the cone penetration tests. Thus, the ambient and vacuum results cannot be compared directly; work is underway to de-confound and better correlate the data. Still, figures 3-6 show that probe penetration forces are lower overall in the vacuum environment. In both environments, resonant vibration of the probe provides two useful effects: It reduces the probe penetration force and smooths the force-depth curve, significantly reducing local maxima. These effects have implications for various potential applications, such as astronaut hand-tools, where benefits (reducing astronaut effort) outweigh the cost of the additional energy re-quired to generate vibration. These results demonstrate that resonantly vibrating tools can meaningfully reduce the penetration force required for excavation, probing, and drilling tools in simulated lunar regolith deposits under vacuum levels approaching those that will be experience on the Moon’s surface. Lunar-gravity, ambient environment tests are scheduled soon. The effects of realistic temperatures and temperature gradients and deeper vacuum remain to be tested.

E Rezich↗