Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reusability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Reusable TPS Materials Development Activities at NASA Ames

Recent developments in low-cost access to low-earth orbit (LEO) and hypersonic flight are driving renewed demand in reusable thermal protection systems (RTPS) that have not had broad application since the Space Shuttle era. Modern systems will need to consider full cycle cost (lower cost raw materials, manufacturing, integration, and refurbishment) in addition to improved performance to enable this new generation of space flight. NASA Ames Research Center (ARC) has a long history of RTPS development including modern state-of-the-art materials like Alumina Enhanced Thermal Barrier (AETB), and multi-component systems like Toughened Uni-piece Fibrous Reinforced Oxidation-resistant Composite (TUFROC). Now, ARC is supporting the growing commercial space field through internal research and development efforts for high-risk low TRL materials and collaboration with commercial partners including technology transfer. This talk will discuss the current development efforts at ARC that span updating legacy insulating systems with modern raw materials and processes to totally novel designs for heat pipes with various low-TRL activities in between. It will also discuss Ames’ recent re-investment in experimental capabilities to enable characterization and material testing.

Adam Caldwell↗

Governing Data Findability, Accessibility, Interoperability and Reusability (FAIR) Compliance

The most recent data strategy documents at both the federal and NASA levels stipulate that systems should strive for the data they manage to be Findable, Accessible, Interoperable, and Reusable (FAIR). The NASA Life Sciences Portal (NLSP) has already begun leading efforts in this area for HRP, initiating efforts to comply with the FAIR principles. The broad interpretation of the FAIR principles has led to a plethora of tools that use a splay of metrics specifically but variably developed to judge how compliant data and systems are with the principles. A recent review [3] identified and studied 1,180 metrics across 20 publicly available tools for checking FAIR compliance of data and systems. Because of their very recent development, many organizations and data systems managers and developers have not yet had adequate time or resources to understand these FAIR compliance tools and metrics, their variations in design, accuracy or ease of application to their specific data sets and systems. Thus, it would be best for larger organizations like NASA to approach formulating a strategy for governance of FAIR compliance that can be flexibly applied and is adaptable to an evolving awareness knowledge of FAIR compliance methods and tools. In September 2024, the NASA Science Mission Directorate(SMD) organized a workshop on NASA science data repositories, including the topics of implementing FAIR and governing FAIR compliance across SMD. The initial part of these FAIR discussions focused on developing consensus around required science metadata fields. This is challenging given the diverse nature of NASA’s scientific data portfolio, the variety of metadata models and vocabularies used, and variable level of resources available to curate these data. Later discussion focused on three possible approaches to governing FAIR compliance: distributed, in which various programs, projects or systems define their own methods for assessing FAIR compliance, reporting results up appropriate management lines; centralized, in which higher-level organization(s) specify compliance tools or methods for the various data systems; and multi-level, in which a group comprised of individuals with expertise from multiple levels with organizations is formed to provide guidance and/or specifications for governing FAIR compliance. We report on the recommendations this session yielded, and how these might be shaped specifically to help implement and govern the compliance with FAIR of Human Research Program data and systems.

governance↗

Uranium In Situ Electrolytic Deposition with a Reusable Functional Graphene-Foam Electrode

Nuclear fission produces 400 GWe which represents 11% of the global electricity output. Uranium is the essential element as both fission fuel and radioactive waste. Therefore, the recovery of uranium is of great importance. In this study, an in situ electrolytic deposition method to extract uranium from aqueous solution is reported. A functionalized reduced graphene oxide foam (3D-FrGOF) is used as the working electrode, which acts as both a hydrogen evolution reaction catalyst and a uranium deposition substrate. The specific electrolytic deposition capacity for U(VI) ions with the 3D-FrGOF is 4560 mg g –1 without reaching saturation, and the Coulombic efficiency can reach 54%. Moreover, reduction of the uranium concentration in spiked seawater from 3 ppm to 19.9 ppb is achieved, which is lower than the US Environmental Protection Agency uranium limits for drinking water (30 ppb). Furthermore, the collection electrode can be efficiently regenerated and recycled at least nine times without much efficiency fading, by ejecting into 2000 ppm concentrated uranium solution in a second bath with reverse voltage bias. All these findings open new opportunities in using free-standing 3D-FrGOF electrode as an advanced separation technique for water treatment.

36 MATERIALS SCIENCE↗

NASA Lessons Learned on Reusable and Expendable Launch Vehicle Operations and Their Application Towards DARPA's Experimental Spaceplane (XS-1) Program

Outline: Selected Historic Shuttle Operations Data; Shuttle Lessons Learned Recommendations for Lower Cost, Operationally Efficient Launch Vehicle Systems; Selected Expendable launch vehicle experiences; Past NASA Launch Vehicle Development Programs, Studies (1985 to present); Discussion: Suggested applications of NASA Lessons Learned to already-baselined contractor XS-1 Phase I concepts.

Reusable launch vehicle↗

Cost and Time Effective Lithography of Reusable Millimeter Size Bone Tissue Replicas With Sub‐15 nm Feature Size on A Biocompatible Polymer

Abstract The ability to replicate the microenvironment of biological tissues creates unique biomedical possibilities for stem cell applications. Current fabrication methods are limited by either the control on feature size and shape, or by the throughput and size of the replicas. Here, a novel platform is reported that combines thermal scanning probe lithography (tSPL) with innovative methodologies for the low‐cost and high‐throughput nanofabrication of large area quasi‐3D bone tissue replicas with high fidelity, sub‐15 nm lateral precision, and sub‐2 nm vertical resolution. This bio‐tSPL platform features a biocompatible polymer resist that withstands multiple cell culture cycles, allowing the reuse of the replicas, further decreasing costs and fabrication times. The as‐fabricated replicas support the culture and proliferation of human induced mesenchymal stem cells, which display broad therapeutic and biomedical potential. Furthermore, it is demonstrated that bio‐tSPL can be used to nanopattern the bone tissue replicas with amine groups, for subsequent tissue‐mimetic biofunctionalization. The achieved level of time and cost‐effectiveness, as well as the cell compatibility of the replicas, make bio‐tSPL a promising platform for the production of tissue‐mimetic replicas to study stem cell‐tissue microenvironment interactions, test drugs, and ultimately harness the regenerative capacity of stem cells and tissues for biomedical applications.

Liu, Xiangyu↗

A reusable neural network pipeline for unidirectional fiber segmentation

Abstract Fiber-reinforced ceramic-matrix composites are advanced, temperature resistant materials with applications in aerospace engineering. Their analysis involves the detection and separation of fibers, embedded in a fiber bed, from an imaged sample. Currently, this is mostly done using semi-supervised techniques. Here, we present an open, automated computational pipeline to detect fibers from a tomographically reconstructed X-ray volume. We apply our pipeline to a non-trivial dataset by Larson et al . To separate the fibers in these samples, we tested four different architectures of convolutional neural networks. When comparing our neural network approach to a semi-supervised one, we obtained Dice and Matthews coefficients reaching up to 98%, showing that these automated approaches can match human-supervised methods, in some cases separating fibers that human-curated algorithms could not find. The software written for this project is open source, released under a permissive license, and can be freely adapted and re-used in other domains.

79 ASTRONOMY AND ASTROPHYSICS↗

A portable and reusable sensor system based on graphene for real-time and sensitive detection of lead ions in water

Long-term exposure to Pb 2+ can cause irreversible damage to the nervous, cardiovascular, and reproductive systems. Therefore, developing a fast and sensitive detection system capable of monitoring minuscule concentrations of Pb 2+ is essential. In this study, we demonstrated a fully portable sensor system enabling rapid, sensitive, and real-time monitoring of Pb 2+ . The sensor system adopted the remote-gate field-effect transistor (RGFET) detection scheme and was easy to operate, even for non-experts. The sensor system comprised two printed circuit boards (PCBs): a sensor PCB with a remote-gate electrode and an analyzer PCB with a metal-oxide-semiconductor field-effect transistor (MOSFET) transducer and peripheral electronics to manage sensor signals. To achieve a high sensitivity for Pb 2+ , we utilized graphene ink drop-casted on the sensor PCB as a sensing membrane. The graphene film was easy to deposit and remove, enabling the sensor PCB to be reused multiple times. The sensor system was further linked to a smartphone application that instantly monitors the sensor response, allowing for rapid point-of-use detection. The sensor exhibited a high sensitivity of 21.7% when the limit of detection (LOD) value of 1 nM (∼0.2 ppb) was detected, and the typical detection time for each sample was approximately 60 seconds. This portable sensor system advances sensing technologies and could potentially supplement expensive, laborious conventional sensing equipment.

54 ENVIRONMENTAL SCIENCES↗