Geometrical-Based Generative Adversarial Network to Enhance Digital Rock Image Quality

X-ray microcomputed tomography (micro-CT) is a common tool for the study of porous media structures and properties. High-quality micro-CT data are required to accurately capture pore structures. Acquiring high-quality micro-CT data, however, is not always possible, owing to application limitations and experimental constraints. Therefore, we propose a geometrical-based generative adversarial network (GAN) to rapidly restore noisy micro-CT images to their clean counterparts. The training data and related ground-truth (GT) data are scanned for 7 min and 9.5 h, respectively. To evaluate the performance of the geometrical-based GAN, a 6003 voxel image that has never been used for training is reconstructed and compared with the corresponding GT image. Histogram matching and linear normalization are implemented to adjust the histogram of the reconstructed image to that of the GT image. A watershed-based segmentation method is then applied to delineate pore and solid phases. Lastly, we measure the Minkowski functionals and petrophysical properties, including absolute permeability, pore size distribution, drainage capillary pressure-saturation curve, and imbibition relative permeability, to estimate the physical accuracy of the denoised image. The results show that the proposed geometrical-based GAN can accurately restore noisy micro-CT data. By reducing the scanning time from 9.5 h to 7 min, the expenditure of collecting micro-CT can be decreased significantly. This is particularly important for applications where time-lapse images of a dynamic process are required, high-throughput imaging is necessary for real-time data analysis, or where the quantification of large sample volumes is required.

58 GEOSCIENCES↗

Muon spin rotation and relaxation in Pr 1 - x Nd x Os 4 Sb 12 : Superconductivity and magnetism in Pr-rich alloys

The Pr-rich end 0 ≤ x ≤ 0.25 of the alloy series Pr 1-x Nd x ⁢Os 4 ⁢Sb 12 has been studied using muon spin rotation and relaxation. The end compound PrOs 4 ⁢Sb 12 is an unconventional heavy-fermion superconductor, which exhibits a spontaneous magnetic field associated with broken time-reversal symmetry (TRS) in the superconducting phase. Further, no such field is observed in the Nd-doped alloys for x ≥ 0.05, indicating that TRS has been restored. The superfluid density from the vortex-lattice field distribution is insensitive to Nd concentration for x ≲ 0.2, indicating that TRS restoration does not have a strong effect on the superconducting state. No Nd 3+ static magnetism, ordered or disordered, is found down to the lowest temperatures of measurement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deblurring for nuclei: 3D characteristics of heavy-ion collisions

Observables from nuclear and high-energy experiments can be degraded by detector performance and/or methodology in extracting the observables, such as of the final-state characteristics of heavy-ion collisions in relation to a coarsely estimated reaction-plane direction. We propose the use of deblurring methods, such as in optics, to correct for observable degradation. Our main focus is the restoration of triple-differential particle distributions in heavy-ion collisions. We demonstrate that these could be extracted from collision measurements following the Richardson-Lucy deblurring method from optics. We illustrate basic features of the restoration methodology in a schematic model assuming either ideal or more realistic particle detection. Here, the inferred three-dimensional (3D) distributions for collisions may be easier to interpret in terms of collision dynamics and sought properties of bulk matter than the currently employed Fourier coefficients, that combine information from different azimuthal angles relative to the reaction plane.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deconvoluting experimental decay energy spectra: The O 26 case

In nuclear reaction experiments, the measured decay energy spectra can give insights into the shell structure of decaying systems. However, extracting the underlying physics from the measurements is challenging due to detector resolution and acceptance effects. The Richardson-Lucy (RL) algorithm, a deblurring method that is commonly used in optics and has proven to be a successful technique for restoring images, was applied to our experimental nuclear physics data. The only inputs to the method are the observed energy spectrum and the detector's response matrix also known as the transfer matrix. We demonstrate that the technique can help access information about the shell structure of particle-unbound systems from the measured decay energy spectrum that is not immediately accessible via traditional approaches such as χ-square fitting. For a similar purpose, we developed a machine learning model that uses a deep neural network (DNN) classifier to identify resonance states from the measured decay energy spectrum. We tested the performance of both methods on simulated data and experimental measurements. Then, we applied both algorithms to the decay energy spectrum of 26 O → 24 O + n + n measured via invariant mass spectroscopy. Here, the resonance states restored using the RL algorithm to deblur the measured decay energy spectrum agree with those found by the DNN classifier. Both deblurring and DNN approaches suggest that the raw decay energy spectrum of 26 O exhibits three peaks at approximately 0.15 MeV, 1.50 MeV, and 5.00 MeV, with half-widths of 0.29 MeV, 0.80 MeV, and 1.85 MeV, respectively.

Spectrometers & spectroscopic techniques↗

Strategic Placement and Sizing of Distributed Generation for Resilience Enhancement of Distribution Grids With Microgrid Formation

The rise in frequency and severity of extreme weather events highlights the need for resilient power distribution networks. Microgrids can help improve the resilience of distribution grids by providing continuous power supply using local distribution generation (DG) when the distribution grid fails. In this paper, we propose an approach for optimal placement and sizing of DG to form multiple microgrids throughout the distribution network by restoration actions such as switching operations in case of distribution grid outages caused by extreme weather events. Considering the randomness of damaged distribution lines, the DG placement and sizing problem is formulated as a two-stage stochastic mixed-integer program, with the first stage determining the placement and size of DG, and the second stage focusing on minimizing the amount of load shedding through network restoration and microgrid formations for each scenario. Due to the large number of scenarios, the sample average approximation (SAA) method is employed to solve the problem. The results of case studies on a modified IEEE 33 bus distribution grid demonstrate the effectiveness of the proposed DG placement and sizing strategy in improving the resilience of distribution grids by allowing the formation of multiple microgrids. In addition, the robustness and accuracy of the SAA method are validated through various case studies.

Distributed generation planning↗

A Secondary Control Framework for Microgrid Interoperability With Vendor-Agnostic Grid-Forming Units: Design, Implementation, and Demonstration via Large-Scale Hardware Setup

The reliable operation of islanded microgrids increasingly depends on secondary controls that restore voltage and frequency to nominal values and ensure accurate active and reactive power sharing. Centralized secondary control architectures achieve high accuracy through global coordination at the cost of single-point failures and limited scalability compared with decentralized/distributed approaches. But a critical gap remains in addressing the interoperability and vendor-agnostic operation of secondary controls in real-world microgrids where heterogeneous diesel generator(s) and grid-forming (GFM) inverter(s) from multiple manufacturers always coexist. Practical and vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids with multiple GFM units have not yet been developed; therefore, this paper proposes an interoperable and vendor-agnostic secondary control framework that operates seamlessly across GFM units from different vendors without relying on proprietary controls and protocols, hardware, or lock-ins. The framework leverages existing communication infrastructures (e.g., Modbus TCP/IP) to enable cost-effective deployment while addressing practical challenges, such as packet loss and quantization errors. Mitigation strategies-including data averaging, situational event-triggered control, and finite-iteration execution-are introduced to enhance reliability under real-world conditions. A generalized modeling and design framework is also presented, supported by robustness analysis to demonstrate independence from vendor-specific implementations. The proposed framework is validated through a large-scale hardware demonstration using a 3-$\phi$, 480-V, 60-Hz, 713-kVA laboratory hardware microgrid involving a heterogeneous diesel generator and multiple GFM inverters, showcasing its effectiveness in achieving stable voltage and frequency restoration and accurate power sharing under practical constraints. The results highlight the framework's potential as a scalable and practical solution for next-generation microgrids requiring openness, standard framework, and interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Challenges of Troubleshooting

Troubleshooting work presents electrical and other workers with a challenging combination of physical hazards, working conditions, and time pressure, which can lead to unwanted outcomes if not carefully managed.Summaries of several incidents in which workers were injured or at risk of injury while performing troubleshooting work are presented, identifying organizational weaknesses and error precursors that contributed to each incident.The primary challenges include:Deranged equipment. Equipment that needs troubleshooting is not in a normal operating condition. Actions that are safe when the equipment is in a normal state may not be safe in the deranged state.Work planning and control. The steps taken in troubleshooting are most often determined by the results of the immediately previous diagnostic test, making effective work planning challenging.Multiple types of hazards. Most equipment will present a troubleshooting worker with several types of hazards, including hazardous energy as defined in 29 CFR 1910.147. Portions of the troubleshooting activity may be infeasible without these hazards present.Time pressure. Restoring operation of failed equipment often involves an explicit or implicit sense of urgency.Equipment design and construction. The physical construction of the equipment in large part will determine to which hazards troubleshooters may be exposed. It will also determine which hazards may be encountered while performing the servicing needed to restore the equipment or system to operation.There are effective methods for addressing each challenge, most of which require a combination of advance preparation and management commitment.

Mertz, David E.↗

Quantitative Evaluation of Reliability Improvement: Case Study on a Self-healing Distribution System

In this work, we develop a methodology and tool to quantitatively evaluate the reliability of a self-healing system that considers practical distribution system features such as the distributed energy resources, microgrids, and service restoration strategies. Also, this paper addresses various practical issues when being applied to an actual Duke Energy distribution system, including the design of feasible and practical service restoration strategies that are used to identify the customer interruptions after a fault, and the incorporation of the utility’s historical reliability indices that are used to calibrate the failure rate and repair time of distribution system components such as overhead lines and underground cables. This case study demonstrates the effectiveness of the proposed method.

Dong, Jiaojiao↗

On Control Schemes for Grid-Forming Inverters

Grid-forming inverters can collaboratively regulate the voltage and frequency of a microgrid. These inverters are expected to be seen more in the future microgrid, undertaking the roles of the conventional power generators. Like conventional power generators, they must balance supply and demand, contribute to power-sharing between inverters and other power generators, and restore the voltage and frequency after any power changes. These technical challenges are typically achieved through different primary and secondary controllers. This article reviews some state-of-the-art primary and secondary control schemes for the emerging technology of grid-forming inverters. First, the typical control schemes for grid-following inverters are briefly presented for the continuity of the discussion on the roles of the grid-forming inverters in future power-grid, followed by two basic control schemes for the grid-forming inverters. Then, two decentralized power-sharing techniques, i.e., droop, and virtual inertia, are analyzed. The technical challenges for inverter synchronization and some control methods are discussed afterward. Finally, several secondary control methods for the voltage and frequency restoration in grid-forming inverters are reviewed.

Sadeque, Fahmid↗

Control and Simulation of a Grid-Forming Inverter for Hybrid PV-Battery Plants in Power System Black Start

Power system restoration is an important part of system planning. Power utilities are required to maintain black start capable generators that can energize the transmission system and provide cranking power to non-blackstart capable generators. Traditionally, hydro and diesel units are used as black start capable generators. With the increased penetration of bulk size solar farms, inverter based generation can play an important role in faster and parallel black start thus ensuring system can be brought back into service without the conventional delays that can be expected with limited black start generators. Inverter-based photovoltaic (PV) power plants have advantages that are suitable for black start. This paper proposes the modeling, control, and simulation of a grid-forming inverter-based PV-battery power plant that can be used as a black start unit. The inverter control includes both primary and secondary control loops to imitate the control of a conventional synchronous machine. The proposed approach is verified using a test system modified from the IEEE 9-bus system in the time-domain electromagnetic transient simulation tool PSCAD. The simulation results shows voltage and frequency stability during a multi-step black-start and network energization process.

Nguyen, Quan H.↗

Power System Recovery Coordinated with (Non-)Black-Start Generators

Power restoration is an urgent task after a black-out, and recovery efficiency is critical when quantifying system resilience. Multiple elements should be considered to restore the power system quickly and safely. This paper proposes a recovery model to solve a direct-current optimal power flow (DCOPF) based on mixed-integer linear programming (MILP). Since most of the generators cannot start independently, the interaction between black-start (BS) and non-black-start (NBS) generators must be modeled appropriately. The energization status of the NBS is coordinated with the recovery status of transmission lines, and both of them are modeled as binary variables. Also, only after an NBS unit receives the cranking power through connected transmission lines, will it be allowed to participate in the following system dispatch. The amount of cranking power is estimated as a fixed proportion to the maximum generation capacity. The proposed model is validated on several test systems, as well as a 1393-bus representation system of the Puerto Rican electric power grid. Test results demonstrate how the recovery of NBS units and damaged transmission lines can be optimized, resulting in an efficient and well-coordinated recovery procedure.

Zhao, Meng↗

Post-Disaster Microgrid Formation for Enhanced Distribution System Resilience

This paper proposes a deep reinforcement learning (DRL) based approach for post-disaster critical load restoration in active distribution systems to form microgrids through network reconfiguration to minimize critical load curtailments. Distribution networks are represented as graph networks, and optimal network configurations with microgrids are obtained by searching for the optimal spanning forest. The constraints to the research question being explored are the radial topology and power balance. Unlike existing analytical and population-based approaches, which necessitate the repetition of entire analyses and computation for each outage scenario to find the optimal spanning forest, the proposed approach, once properly trained, can quickly determine the optimal, or near-optimal, spanning forest even when outage scenarios change. When multiple lines fail in the system, the proposed approach forms microgrids with distributed energy resources in active distribution systems to reduce critical load curtailment. The proposed DRL-based model learns the action-value function using the REINFORCE algorithm, which is a model-free reinforcement learning technique based on stochastic policy gradients. A case study was conducted on a 33-node distribution test system, demonstrating the effectiveness of the proposed approach for post-disaster critical load restoration.

active distribution systems↗

Quantitative Metrics for Grid Resilience Evaluation and Optimization

Power system resilience has become a critical topic in recent years because of the increasing trend of extreme events and the growing integration of intermittent renewable energy sources. To enhance grid resilience against high-impact, low-frequency events, two questions should be answered: how to quantify the resilience of a given grid and how to incorporate the quantification into power system planning, operation, and restoration. Here this paper develops a new set of quantitative metrics with clear physical interpretation to comprehensively evaluate power system resilience. Using microgrids as an example, an event-based corrective scheduling (ECS) model and an online model predictive control (OMPC) model are developed to integrate the proposed quantitative resilience metrics into power system optimization models for resilience enhancement. The ECS model employs extreme event data to investigate the optimal restoration solution and to help microgrid operators prepare to respond to similar events. The OMPC model provides online decision-making support for operators to handle ongoing outages in the most resilient fashion. The effectiveness and superiority of the proposed quantitative resilience metrics and the resilience enhancement models are demonstrated through simulations and comparative studies on an IEEE test feeder and a real distribution feeder in Southern California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Climate cooling benefits of cellulosic bioenergy crops from elevated albedo

Abstract Changes in land surface albedo can alter ecosystem energy balance and potentially influence climate. We examined the albedo of six bioenergy cropping systems in southwest Michigan USA: monocultures of energy sorghum ( Sorghum bicolor ), switchgrass ( Panicum virgatum L.), and giant miscanthus ( Miscanthus × giganteus) , and polycultures of native grasses, early successional vegetation, and restored prairie. Direct field measurements of surface albedo ( α s ) from May 2018 through December 2020 at half‐hourly intervals in each system quantified the magnitudes and seasonal differences in albedo (∆ α ) and albedo‐induced radiative forcing (RF ∆ α ). We used a nearby forest as a historical native cover type to estimate reference albedo and RF ∆ α change upon original land use conversion, and a continuous no‐till maize ( Zea mays L .) system as a contemporary reference to estimate change upon conversion from annual row crops. Annually, α s differed significantly ( p < 0.05) among crops in the order: early successional (0.288 ± 0.012SE) >> miscanthus (0.271 ± 0.009) ≈ energy sorghum (0.270 ± 0.010) ≥ switchgrass (0.265 ± 0.009) ≈ restored prairie (0.264 ± 0.012) > native grasses (0.259 ± 0.010) > maize (0.247 ± 0.010). Reference forest had the lowest annual α s (0.134 ± 0.003). Albedo differences among crops during the growing season were also statistically significant, with growing season α s in perennial crops and energy sorghum on average ~20% higher (0.206 ± 0.003) than in no‐till maize (0.184 ± 0.002). Average non‐growing season (NGS) α s (0.370 ± 0.020) was much higher than growing season α s (0.203 ± 0.003) but these NGS differences were not significant. Overall, the original conversion of reference forest and maize landscapes to perennials provided a cooling effect on the local climate (RF αMAIZE : −3.83 ± 1.00 W m −2 ; RF αFOREST : −16.75 ± 3.01 W m −2 ). Significant differences among cropping systems suggest an additional management intervention for maximizing the positive climate benefit of bioenergy crops, with cellulosic crops on average ~9.1% more reflective than no‐till maize, which itself was about twice as reflective as the reference forest.

Lei, Cheyenne↗

Inoculated biocrust cover and functions diverged over a gradient of soil textures and water availability

Restoring biological crust (biocrust) in disturbed drylands is challenging due to the difficult environmental conditions, such as limited soil moisture, low soil nutrients, and extreme temperatures, that impede growth. Understanding how the key components of biocrust—mosses, lichens, and cyanobacteria—react to different environmental factors informs the optimal timing, locations, and species composition for biocrust reintroduction, thereby increasing the likelihood of establishment. Here, we inoculated soils with a diverse range of biocrust organisms, analogous to seeding an area with diverse vascular plant seeds, and varied environmental conditions to observe how these changes influenced the development and functions of reintroduced biocrust. We found that by manipulating soil texture and time spent wet, we can change the proportional cover of biocrust within a restoration‐like setting. Specifically, we found that 4 months after inoculation, finer textured soils that received more water become dominated by moss cover, while coarser textured soils with less water remained dominated by cyanobacteria cover, and the interactions between texture and time spent wet strongly influenced cover. We found biocrust morphological group cover had a small, but detectable, effect on ecosystem functions (soil stability and nitrogenase activity, a proxy for nitrogen fixation), but that environmental conditions had a stronger impact on the functions we measured. Manipulative experiments in controlled environments, like this one, can help elucidate the mechanisms underlying the establishment rate and patterns of biocrusts post‐inoculation, and inform implementation of inoculations in the field.

Environmental Sciences & Ecology↗

Response of ectomycorrhizal fungi to full and selective removal of an invasive tree in riparian woodland

The Brazilian pepper tree ( Schinus terebinthifolius ) is an invasive species that requires significant disturbance to eradicate. Previous studies have identified associations between the Brazilian pepper tree and ectomycorrhizal fungi (EMF). However, limited research has explored the connection between disturbance from removal and the effect on EMF. This study investigated the sensitivity of EMF and the broader fungal community to the full and selective removal of the Brazilian pepper tree. During the selective removal of Brazilian pepper tree, we examined the mycorrhizal community of the Arroyo willow ( Salix lasiolepis ) to assess the influence of the restoration disturbance on native species. We used ITS2 sequencing to identify the EMF present during the restoration. Our expectation was that both removal efforts would reduce the presence of EMF. Contrary to our predictions, full removal increased EMF richness and relative abundance in the soil. As anticipated, selective removal reduced the richness and relative abundance of EMF associated with soil. Selective removal led to a decrease in the richness of EMF in arroyo willow roots with no effect on relative abundance. Moreover, fungal community composition in soil and roots shifted significantly during selective and full removal. However, the community composition of EMF, specifically, remained constant across treatment types. During full removal efforts, the application of organic soil amendments may have contributed to the increase in the diversity and relative abundance of EMF. Selective removal will require additional measures, such as soil amendments, to curtail the loss of EMF.

Environmental Sciences & Ecology↗

On interpretation of fluctuations of conserved charges at high T

Abstract Fluctuations of conserved charges calculated on the lattice which can be measured experimentally, are well reproduced by a hadron resonanse gas model at temperatures below$$T_{ch} \sim 155$$ T ch ∼ 155 MeV and radically deviate from the hadron resonance gas predictions above the chiral restoration crossover. This behaviour is typically interpreted as an indication of deconfinement in the quark-gluon plasma regime. We present an argument that this interpretation may be too simple. The argument is based on the scaling of quantities with the number of colors: demonstration of deconfinement and QGP requires observable that is sensitive to$$\sim N_c^2$$ ∼ N c 2 gluons while the conserved charges are sensitive only to quarks and above$$T_{ch}$$ T ch scale as$$N_c^1$$ N c 1 . The latter scaling is consistent with the existence of an intermediate regime characterized by restored chiral symmetry and by approximate chiral spin symmetry which is a symmetry of confining interaction. In this regime the energy density, pressure and entropy density scale as$$N_c^1$$ N c 1 . In the large$$N_c$$ N c limit this regime might become a distinct phase separated from the hadron gas and from QGP by phase transitions. A natural observable that associates with deconfinement and is directly sensitive to deconfined$$N_c^2-1$$ N c 2 - 1 gluons is the Polyakov loop; in the$$N_c=3$$ N c = 3 world it remains very close to 0 at temperatures well above chiral crossover, reaches the value$$\sim 0.5$$ ∼ 0.5 around$$\sim 3T_{ch}$$ ∼ 3 T ch and the value close to 1 at temperatures$$\sim 1$$ ∼ 1 GeV.

Physics↗