Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Response Spectrum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Simulation of Climatic Changes in the Arctic and North Atlantic During Recent Decades

The interactions of the atmosphere and ice-ocean system in the Arctic will be studied using a coupled ice-ocean model which will also use ice drift derived from microwave observations as forcing. We especially search for linkages between the recent large climatic shifts in the Arctic Ocean and atmosphere for which period we also have microwave sea ice data. The coupled model area covers the whole N. Atlantic thus interactions between the lower latitudes are also investigated because we anticipate that the same large scale atmospheric patterns which dominate the midlatitudes extend their influence on the Arctic. The model hindcast for 1951-1993 shows clear decadal variability in the leading modes of ocean circulation. No specific low-freq modes are expected for the ice drift because its spectrum is white. However, the ice drift exhibits two see-saw patterns in response to the leading atmospheric circulation mode ('Arctic Oscillation'), one of them is the well-known out of phase relationship between Baffin Bay and Barents-Kara Seas, the other one is between Siberian shelf and Alaskan Coast (Hakkinen and Geiger, 2000).

Hakkinen, Sirpa↗

Estimation of Aircraft Unsteady Aerodynamic Parameters from Dynamic Wind Tunnel Testing

Improved aerodynamic mathematical models, for use in aircraft simulation or flight control design, are required when representing nonlinear unsteady aerodynamics. A key limitation of conventional aerodynamic models is the inability to map frequency and amplitude dependent data into the equations of motion directly. In an effort to obtain a more general formulation of the aerodynamic model, researchers have been led to a parallel requirement for more general testing methods. Testing for a more comprehensive model can lead to a very time consuming number of tests especially if traditional single frequency harmonic testing is attempted. This paper presents an alternative to traditional single frequency forced-oscillation testing by utilizing Schroeder sweeps to efficiently obtain the frequency response of the unsteady aerodynamic model. Schroeder inputs provide signals with a flat power spectrum over a specified frequency band. For comparison, experimental results using the traditional single-frequency inputs are also considered. A method for data analysis to determine an adequate unsteady aerodynamic model is presented. Discussion of associated issues that arise during this type of analysis and comparison of results using traditional single frequency analysis are provided.

Murphy, Patrick C.↗

Effects of pH and dose on nasal absorption of scopolamine hydrobromide in human subjects

PURPOSE: The present study was conducted to evaluate the effects of formulation pH and dose on nasal absorption of scopolamine hydrobromide, the single most effective drug available for the prevention of nausea and vomiting induced by motion sickness. METHODS: Human subjects received scopolamine nasally at a dose of 0.2 mg/0.05 mL or 0.4 mg/0.10 mL, blood samples were collected at different time points, and plasma scopolamine concentrations were determined by LC-MS/MS. RESULTS: Following administration of a 0.2 mg dose, the average Cmax values were found to be 262+/-118, 419+/-161, and 488+/-331 pg/ mL for pH 4.0, 7.0, and 9.0 formulations, respectively. At the 0.4 mg dose the average Cmax values were found to be 503+/-199, 933+/-449, and 1,308+/-473 pg/mL for pH 4.0, 7.0, and 9.0 formulations, respectively. At a 0.2 mg dose, the AUC values were found to be 23,208+/-6,824, 29,145+/-9,225, and 25,721+/-5,294 pg x min/mL for formulation pH 4.0, 7.0, and 9.0, respectively. At a 0.4 mg dose, the average AUC value was found to be high for pH 9.0 formulation (70,740+/-29,381 pg x min/mL) as compared to those of pH 4.0 (59,573+/-13,700 pg x min/mL) and pH 7.0 (55,298+/-17,305 pg x min/mL) formulations. Both the Cmax and AUC values were almost doubled with doubling the dose. On the other hand, the average Tmax, values decreased linearly with a decrease in formulation pH at both doses. For example, at a 0.4 mg dose, the average Tmax values were 26.7+/-5.8, 15.0+/-10.0, and 8.8+/-2.5 minutes at formulation pH 4.0, 7.0, and 9.0, respectively. CONCLUSIONS: Nasal absorption of scopolamine hydrobromide in human subjects increased substantially with increases in formulation pH and dose.

Controlled Clinical Trial↗

The Solar Spectrum on the Martian Surface and its Effect on Photovoltaic Performance

Solar cells operating on the surface of Mars receive a spectrum of illumination different from the AM0 spectrum, since the sunlight is filtered by dust suspended in the atmosphere. This spectrum changes with the amount of dust in the atmosphere, as well as with air mass change due to time of day and season. This spectral variation affects the performance of solar cells. We used data from Mars Exploration Rovers to measure this spectrum. By comparing the measured intensity with the known reflectance of the pancam calibration target on the rovers Spirit and Opportunity, we measure the solar spectrum reaching the surface. The effect of this spectrum on the performance of solar cells is then calculated based on the spectral response of several different solar cell types.

Landis, Geoffrey A.↗

Mobile Instruments Measure Atmospheric Pollutants

As a part of NASA's active research of the Earth s atmosphere, which has included missions such as the Atmospheric Laboratory of Applications and Science (ATLAS, launched in 1992) and the Total Ozone Mapping Spectrometer (TOMS, launched on the Earth Probe satellite in 1996), the Agency also performs ground-based air pollution research. The ability to measure trace amounts of airborne pollutants precisely and quickly is important for determining natural patterns and human effects on global warming and air pollution, but until recent advances in field-grade spectroscopic instrumentation, this rapid, accurate data collection was limited and extremely difficult. In order to understand causes of climate change and airborne pollution, NASA has supported the development of compact, low power, rapid response instruments operating in the mid-infrared "molecular fingerprint" portion of the electromagnetic spectrum. These instruments, which measure atmospheric trace gases and airborne particles, can be deployed in mobile laboratories - customized ground vehicles, typically - to map distributions of pollutants in real time. The instruments must be rugged enough to operate rapidly and accurately, despite frequent jostling that can misalign, damage, or disconnect sensitive components. By measuring quickly while moving through an environment, a mobile laboratory can correlate data and geographic points, revealing patterns in the environment s pollutants. Rapid pollutant measurements also enable direct determination of pollutant sources and sinks (mechanisms that remove greenhouse gases and pollutants), providing information critical to understanding and managing atmospheric greenhouse gas and air pollutant concentrations.

Source record↗

The Solar Spectrum on the Martian Surface and Its Effect on Photovoltaic Performance

Solar cells operating on the surface of Mars receive a spectrum of illumination different from the AM0 spectrum, since the sunlight is filtered by dust suspended in the atmosphere. This spectrum changes with the amount of dust in the atmosphere, as well as with air mass change due to time of day and season. This spectral variation affects the performance of solar cells. We used data from Mars Exploration Rovers to measure this spectrum. By comparing the measured intensity with the known reflectance of the pancam calibration target on the rovers Spirit and Opportunity, we measure the solar spectrum reaching the surface. The effect of this spectrum on the performance of solar cells is then calculated based on the spectral response of several different solar cell types.

Landis, Geoffrey A.↗

ART-XC/SRG: Status of the X-ray Optics Development

The Astronomical Roentgen Telescope (ART) instrument is a hard x-ray instrument with energy response up to 30 keV that is to be launched on board of the Spectrum Roentgen Gamma (SRG) Mission. The instrument consists of seven identical mirror modules coupled with seven CdTe strip focal-plane detectors. The mirror modules are being developed at the Marshall Space Flight Center (MSFC.) Each module has approximately 65 sq. cm effective area and an on-axis angular resolution of 30 arcseconds half power diameter (HPD) at 8 keV. The current status of the mirror module development and testing will be presented.

Gubarev, M.↗

ART-XC/SRG: Status of the X-ray Optics Development

The Astronomical Roentgen Telescope (ART) instrument is a hard-x-ray instrument with energy response up to 30 keV that is to be launched on board of the Spectrum Roentgen Gamma (SRG) Mission. The instrument consists of seven identical mirror modules coupled with seven CdTe strip focal-plane detectors. The mirror modules are being developed at the Marshall Space Flight Center (MSFC.) Each module has approx. 65 sq. cm effective area and an on-axis angular resolution of 30 arcseconds half power diameter (HPD) at 8 keV. The current status of the mirror module development and testing will be presented.

Gubarev, M.↗

ART-XC/SRG: Status of the X-ray Optics Development

The Astronomical Roentgen Telescope (ART) instrument is a hard-x-ray instrument with energy response up to 30 keV that is to be launched on board of the Spectrum Roentgen Gamma (SRG) Mission. The instrument consists of seven identical mirror modules coupled with seven CdTe strip focal-plane detectors. The mirror modules are being developed at the Marshall Space Flight Center (MSFC.) Each module has approximately 65 sq. cm effective area and an on-axis angular resolution of 30 arcseconds half power diameter (HPD) at 8 keV. The current status of the mirror module development and testing will be presented.

Gubarev, M.↗

MeV Emission from Pulsar Wind Nebulae: Understanding Extreme Particle Acceleration in Highly Relativistic Outflows

The Earth is constantly bombarded from outer space by energetic particles. Where and how these "cosmic rays" are produced is poorly understood, with various particle types and energies likely originating from different sources. Particularly mysterious is the source of high-energy e+/- produced in our Galaxy, especially those responsible for both the high fraction of e+ in the GeV cosmic ray lepton spectrum and the e+/- and observed excess of microwaves and gamma-rays detected towards the Galactic center and bulge. While these particles could be evidence for exotic forms of dark matter, they might also be produced by "normal" astrophysical sources such as pulsars the strongly magnetized, rapidly rotating neutron stars whose rotational energy powers an ultra-relativistic outflow (commonly referred to as a "pulsar wind") whose interaction with the surrounding medium creates a pulsar wind nebula .While the detection of TeV emission from numerous PWNe strongly suggest they contain e+/- with PeV or higher energies, how and to what energies these particles are produced is unknown, let alone their dependence on the properties of the pulsar, pulsar wind, and surrounding medium. A major reason for this uncertainty is the lack of information concerning their MeV properties, since the synchrotron emission from the highest energy e+/- peaks in this waveband. Only by combining the MeV spectrum of PWNe measured by proposed missions with that obtained at lower (primarily radio and X-ray) and higher (TeV) photon energies by current and hopefully future facilities is it possible to measure the full spectrum of e+/- in these sources. The resultant insights into the underlying acceleration mechanism would significantly impact many areas of astrophysics from indirect searches for dark matter to the origin of cosmic rays to the physics of relativistic outflows observed from active galactic nuclei, gamma-ray bursts, and some gravitational wave events.

Gelfand, Joseph D.↗

Initial On-Orbit Spectral Calibration of the PACE Ocean Color Instrument

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Project Science Team has used Ocean Color Instrument (OCI) measurements of Fraunhofer lines in spectra of sunlight reflected by the solar diffuser and measurements of atmospheric absorption bands in cloudtop and ocean spectra to characterize the spectral calibration of OCI on orbit. Multiple lines have been analyzed for both the ultraviolet to visible (UVVIS, 340−607 nm) and visible to near-infrared (VISNIR, 597−897 nm) grating spectrographs. The spectrographs yield hyperspectral observations with 5 nm bandwidths and 0.625 nm sampling intervals. The on-orbit observations have been compared with the prelaunch spectral calibration of OCI performed by the Goddard Laser for Absolute Measurement of Radiance (GLAMR) during thermal vacuum testing to track any changes in the calibration since launch. The calibration analyzed the line positions and strengths for the Fraunhofer lines for each spectrograph by comparing the solar spectra measured by OCI with predicted solar spectra derived from the solar reference spectrum and the BRDF of the solar diffuser, convolved with the OCI relative spectral responses. The calibration also compared the line positions of the atmospheric absorption bands with the model transmissions used by the PACE Project. The line position comparisons show that the root mean square (RMS) spectral difference between the measured and predicted spectra is 0.15 nm, the average spectral shift is 0.062 nm, and the residual spectral dispersion over the wavelength range of the Fraunhofer lines is 0.17 nm. All three estimates of the spectral accuracy of OCI meet the instrument functional requirement of a spectral accuracy of 0.5 nm and are well within the 0.625 nm sampling interval of the data. The line strength comparisons between measured and predicted spectra are essentially the same. These results show that the spectral calibration of OCI on orbit has not drifted since the prelaunch calibration of OCI by GLAMR and that the on-orbit spectral calibration of OCI is stable over time. These results also provide a baseline for monitoring the future spectral performance of OCI on orbit.

Radiometric Calibration↗

Analysis and Validation of Spectral Irradiance Simulations for 75 kW Bifacial Solar Test Field

This work investigates how the spectrum of irradiance incident on the rear of bifacial modules impacts their performance. Light incident on the rear of bifacial modules can be reflected from the ground, mounting structures, and other nearby objects, causing both the intensity and spectrum to be modified. As a result, PV cells and sensors with different spectral responses report different values for the rear irradiance, leading to increased uncertainty when modeling performance. Here, we calculate the spectral irradiance incident on the rear of modules through raytrace simulations and validate with measured field data collected from a 75kW single-axis-tracked bifacial test site. Spectral responses for different sensors and PV cells are applied and compared with field measurements for four days. Based on these results, a method for improving non-spectral simulations is proposed. In addition, a linear regression is applied to the modeled spectral results as a method to gain insight into the contributions of ground reflected light to total rear irradiance.

bifacial photovoltaics↗

Analytical and numerical investigation of structural response of compliant wall materials, part 1

Surface motion of compliant walls in drag reduction experiments was analyzed. Critical comparison was made between the dynamic motion of the structure and the postulated mechanism of drag reduction. The spectrum of surface motion indicated that membranes over deep cavities respond at low frequencies and large wavelengths. The membrane over a deep cavity is therefore found not to yield the desired response predicted by the postulated mechanism. The membrane over a thin air gap is found to act as a wavelength chopper, and analysis of the nonlinear response of that compliant surface indicated its possible suitability for compliant wall experiments. Periodic structures are found to lock in the desired wavelengths of motion, and it was shown that at least in Kramer's initial experiments they produced high frequency surface motions. Laminated structures are found to be very ineffective as compliant models, except when there is no bonding between the membrane and the backing. Computer programs developed for these analyses are documented.

Balasubramanian, R.↗

Deep learning for exploring ultra-thin ferroelectrics with highly improved sensitivity of piezoresponse force microscopy

Hafnium oxide-based ferroelectrics have been extensively studied because of their existing ferroelectricity, even in ultra-thin film form. However, studying the weak response from ultra-thin film requires improved measurement sensitivity. In general, resonance-enhanced piezoresponse force microscopy (PFM) has been used to characterize ferroelectricity by fitting a simple harmonic oscillation model with the resonance spectrum. However, an iterative approach, such as traditional least squares (LS) fitting, is sensitive to noise and can result in the misunderstanding of weak responses. In this study, we developed the deep neural network (DNN) hybrid with deep denoising autoencoder (DDA) and principal component analysis (PCA) to extract resonance information. The DDA/PCA-DNN improves the PFM sensitivity down to 0.3 pm, allowing measurement of weak piezoresponse with low excitation voltage in 10-nm-thick Hf 0.5 Zr 0.5 O 2 thin films. Our hybrid approaches could provide more chances to explore the low piezoresponse of the ultra-thin ferroelectrics and could be applied to other microscopic techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Issues in protection from galactic cosmic rays

Radiation risks to astronauts depend on the microscopic fluctuations of energy absorption events in specific tissues. These fluctuations depend not only on the space environment but also on the modifications of that environment by the shielding provided by structures surrounding the astronauts and the attenuation characteristics of the astronaut's body. The effects of attenuation within the shield and body depends on the tissue biological response to these microscopic fluctuations. In the absence of an accepted method for estimating astronaut risk, we examined the attenuation characteristics using conventional linear energy transfer (LET)-dependent quality factors (as one means of representing relative biological effectiveness, RBE) and a track-structure repair model to fit cell transformation (and inactivation) data in the C3H10 T1/2 mouse cell system obtained for various ion beams. Although the usual aluminum spacecraft shield is effective in reducing dose equivalent with increasing shield thickness, cell transformation rates are increased for thin aluminum shields. Clearly, the exact nature of the biological response to LET and track width is critical to evaluation of biological protection factors provided by a shield design. A significant fraction of biological injury results from the LET region above 100 keV/mu m. Uncertainty in nuclear cross-sections results in a factor of 2-3 in the transmitted LET spectrum beyond depths of 15 g/cm2, but even greater uncertainty is due to the combined effects of uncertainty in biological response and nuclear parameters. Clearly, these uncertainties must be reduced before the shield design can be finalised.

NASA Discipline Number 45-10↗

Light-Induced Melting of Competing Stripe Orders without Introducing Superconductivity in La 2 − x Ba x CuO 4

The ultrafast manipulation of quantum material has led to many novel and significant discoveries. Among them, the light-induced transient superconductivity in cuprates achieved by melting competing stripe orders represents a highly appealing accomplishment. However, recent investigations have shown that the notion of photoinduced superconductivity remains a topic of controversy, and its elucidation solely through c -axis time-resolved terahertz spectroscopy remains an arduous task. Here, we measure the in-plane and out-of-plane transient terahertz responses simultaneously in the stripe-ordered nonsuperconducting La 2 − x Ba x CuO 4 after near-infrared excitations. We find that although a pump-induced reflectivity edge appears in the c -axis reflectance spectrum, the reflectivity along the CuO 2 planes decreases simultaneously, indicating an enhancement in the scattering rate of quasiparticles. This in-plane transient response is clearly distinct from the features associated with superconducting condensation. Therefore, we conclude the out-of-plane transient responses cannot be explained by an equivalent of Josephson tunneling. Notably, those pump-induced terahertz responses remain consistent even when we vary the near-infrared optical pump wavelengths and hole concentrations. Our results provide critical evidence that transient three-dimensional superconductivity cannot be induced by melting the competing stripe orders with pump pulses whose photon energy is much higher than the superconducting gap of cuprates. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

The integrated optic RF spectrum analyzer

The results of measurements made on a fully integrated optic RF spectrum analyzer (IOSA) are reported. The performance of the device acousto-optic bandwidth, single-tone RF resolution, two-tone RF resolution, single-tone dynamic range, two-tone dynamic range, and single-tone RF response are presented. The device parameters that control device performance are analyzed. These results demonstrate the viability of the IOSA for real time spectrum analysis of pulsed and CW RF signals. Improvements of RF bandwidth resolution can be obtained by the use of larger collimated optical beams which requires larger optical lens elements, and hence, larger crystals.

Pedinoff, M. E.↗

Oxygen Vacancy Injection as a Pathway to Enhancing Electromechanical Response in Ferroelectrics

Since their discovery in late 1940s, perovskite ferroelectric materials have become one of the central objects of condensed matter physics and materials science due to the broad spectrum of functional behaviors they exhibit, including electro-optical phenomena and strong electromechanical coupling. In such disordered materials, the static properties of defects such as oxygen vacancies are well explored but the dynamic effects are less understood. In this work, the first observation of enhanced electromechanical response in BaTiO3 thin films is reported driven via dynamic local oxygen vacancy control in piezoresponse force microscopy (PFM). A persistence in peizoelectricity past the bulk Curie temperature and an enhanced electromechanical response due to a created internal electric field that further enhances the intrinsic electrostriction are explicitly demonstrated. The findings are supported by a series of temperature dependent band excitation PFM in ultrahigh vacuum and a combination of modeling techniques including finite element modeling, reactive force field, and density functional theory. Furthermore, this study shows the pivotal role that dynamics of vacancies in complex oxides can play in determining functional properties and thus provides a new route toward– achieving enhanced ferroic response with higher functional temperature windows in ferroelectrics and other ferroic materials.

36 MATERIALS SCIENCE↗