Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Burning and Suppression of Solids–II (BASS-II) Summary Report

The Burning and Suppression of Solids (BASS) experiment hardware is a small flow duct that provides containment for small scale burning of solid samples within the Microgravity Science Glovebox (MSG) aboard the International Space Station (ISS). A video camera with a data overlay and a 35-mm still camera record the combustion events. The controls (ignition, fan speed, etc.) are operated by an astronaut while the principal investigator team monitors the experiment from the ground and communicates directly with the astronaut. For the first time on ISS, BASS–II utilized MSG working volume dilution with gaseous N2. We developed a perfectly stirred reactor model to determine the N2 flow time and flow rate to obtain the desired reduced O2 concentration in the working volume for each test. We calibrated the model with the Compound Specific Analyzer-Combustion Products (CSA-CP) O2 readings offset using the Major Constituents Analyzer reading of the ISS ambient atmosphere data for that day. This worked out extremely well for operations, and added a new vital variable, ambient O2 level, to our test matrices. The main variables tested in BASS–II were ambient O2 concentration, ventilation flow velocity, and fuel type, thickness, and geometry. BASS–II also utilized the onboard CSA-CP for O2 and CO readings, and the Carbon Dioxide Monitor for CO2 readings before and after each test. Readings from these sensors allow us to evaluate the completeness of the combustion. The O2 and CO2 readings before and after each test were analyzed and compared very well to stoichiometric ratios for a one-step gas-phase reaction. The CO versus CO2 followed a linear trend for some datasets, but not for all the different geometries of fuel and flow tested. We calculated the heat release rates during each test from the O2 consumption and burn times, using the constant 13.1 kJ of heat released per gram of O2 consumed. The results showed that most of the tests had heat release rates well below 100 W. Lastly, the global equivalence ratio for the tests is estimated to be fuel rich, 1.3 on average using mass loss and O2 consumption data.

Microgravity↗

SDS: A Framework for Scientific Data Services

Large-scale scientific applications typically write their data to parallel file systems with organizations designed to achieve fast write speeds. Analysis tasks frequently read the data in a pattern that is different from the write pattern, and therefore experience poor I/O performance. In this paper, we introduce a prototype framework for bridging the performance gap between write and read stages of data access from parallel file systems. We call this framework Scientific Data Services, or SDS for short. This initial implementation of SDS focuses on reorganizing previously written files into data layouts that benefit read patterns, and transparently directs read calls to the reorganized data. SDS follows a client-server architecture. The SDS Server manages partial or full replicas of reorganized datasets and serves SDS Clients' requests for data. The current version of the SDS client library supports HDF5 programming interface for reading data. The client library intercepts HDF5 calls and transparently redirects them to the reorganized data. The SDS client library also provides a querying interface for reading part of the data based on user-specified selective criteria. We describe the design and implementation of the SDS client-server architecture, and evaluate the response time of the SDS Server and the performance benefits of SDS.

59 BASIC BIOLOGICAL SCIENCES↗

Lower viral evolutionary pressure under stable versus fluctuating conditions in subzero Arctic brines

Climate change threatens Earth’s ice-based ecosystems which currently offer archives and eco-evolutionary experiments in the extreme. Arctic cryopeg brine (marine-derived, within permafrost) and sea ice brine, similar in subzero temperature and high salinity but different in temporal stability, are inhabited by microbes adapted to these extreme conditions. However, little is known about their viruses (community composition, diversity, interaction with hosts, or evolution) or how they might respond to geologically stable cryopeg versus fluctuating sea ice conditions. We used long- and short-read viromics and metatranscriptomics to study viruses in Arctic cryopeg brine, sea ice brine, and underlying seawater, recovering 11,088 vOTUs (~species-level taxonomic unit), a 4.4-fold increase of known viruses in these brines. More specifically, the long-read-powered viromes doubled the number of longer (≥25 kb) vOTUs generated and recovered more hypervariable regions by >5-fold compared to short-read viromes. Distribution assessment, by comparing to known viruses in public databases, supported that cryopeg brine viruses were of marine origin yet distinct from either sea ice brine or seawater viruses, while 94% of sea ice brine viruses were also present in seawater. A virus-encoded, ecologically important exopolysaccharide biosynthesis gene was identified, and many viruses (~half of metatranscriptome-inferred “active” vOTUs) were predicted as actively infecting the dominant microbial genera Marinobacter and Polaribacter in cryopeg and sea ice brines, respectively. Evolutionarily, microdiversity (intra-species genetic variations) analyses suggested that viruses within the stable cryopeg brine were under significantly lower evolutionary pressures than those in the fluctuating sea ice environment, while many sea ice brine virus-tail genes were under positive selection, indicating virus-host co-evolutionary arms races. Our results confirmed the benefits of long-read-powered viromics in understanding the environmental virosphere through significantly improved genomic recovery, expanding viral discovery and the potential for biological inference. Evidence of viruses actively infecting the dominant microbes in subzero brines and modulating host metabolism underscored the potential impact of viruses on these remote and underexplored extreme ecosystems. Microdiversity results shed light on different strategies viruses use to evolve and adapt when extreme conditions are stable versus fluctuating. Together, these findings verify the value of long-read-powered viromics and provide foundational data on viral evolution and virus-microbe interactions in Earth’s destabilized and rapidly disappearing cryosphere.

59 BASIC BIOLOGICAL SCIENCES↗

Constructing high complexity synthetic libraries of long ORFs using in vitro selection

We present a method that can significantly increase the complexity of protein libraries used for in vitro or in vivo protein selection experiments. Protein libraries are often encoded by chemically synthesized DNA, in which part of the open reading frame is randomized. There are, however, major obstacles associated with the chemical synthesis of long open reading frames, especially those containing random segments. Insertions and deletions that occur during chemical synthesis cause frameshifts, and stop codons in the random region will cause premature termination. These problems can together greatly reduce the number of full-length synthetic genes in the library. We describe a strategy in which smaller segments of the synthetic open reading frame are selected in vitro using mRNA display for the absence of frameshifts and stop codons. These smaller segments are then ligated together to form combinatorial libraries of long uninterrupted open reading frames. This process can increase the number of full-length open reading frames in libraries by up to two orders of magnitude, resulting in protein libraries with complexities of greater than 10(13). We have used this methodology to generate three types of displayed protein library: a completely random sequence library, a library of concatemerized oligopeptide cassettes with a propensity for forming amphipathic alpha-helical or beta-strand structures, and a library based on one of the most common enzymatic scaffolds, the alpha/beta (TIM) barrel. Copyright 2000 Academic Press.

Non-NASA Center↗

False positives in PIRADS (V2) 3, 4, and 5 lesions: relationship with reader experience and zonal location

Purpose: To investigate the effect of reader experience and zonal location on the occurrence of false positives (FPs) in PIRADS (V2) 3, 4, and 5 lesions on multiparametric (MP)-MRI of the prostate. Materials and methods: This retrospective study included 139 patients who had consecutively undergone an MP-MRI of the prostate in combination with a transrectal ultrasound MRI fusion-guided biopsy between 2014 and 2017. MRI exams were prospectively read by a group of inexperienced radiologists (cohort 1; 54 patients) and an experienced radiologist (cohort 2; 85 patients). Multivariable logistic regression analysis was performed to determine the association of experience of the radiologist and zonal location with a FP reading. FP rates were compared between readings by inexperienced and experienced radiologists according to zonal location, using Chi-square (χ{sup 2}) tests. Results: A total of 168 lesions in 139 patients were detected. Median patient age was 68 years (Interquartile range (IQR) 62.5–73), and median PSA was 10.9 ng/mL (IQR 7.6–15.9) for the entire patient cohort. According to multivariable logistic regression, inexperience of the radiologist was significantly (P = 0.044, odds ratio 1.927, 95% confidence interval [CI] 1.017–3.651) and independently associated with a FP reading, while zonal location was not (P = 0.202, odds ratio 1.444, 95% CI 0.820–2.539). In the transition zone (TZ), the FP rate of the inexperienced radiologists 59% (17/29) was significantly higher (χ{sup 2}P = 0.033) than that of the experienced radiologist 33% (13/40). Conclusion: Inexperience of the radiologist is significantly and independently associated with a FP reading, while zonal location is not. Inexperienced radiologists have a significantly higher FP rate in the TZ.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

polishCLR: A Nextflow Workflow for Polishing PacBio CLR Genome Assemblies

Long-read sequencing has revolutionized genome assembly, yielding highly contiguous, chromosome-level contigs. However, assemblies from some third generation long read technologies, such as Pacific Biosciences (PacBio) continuous long reads (CLR), have a high error rate. Such errors can be corrected with short reads through a process called polishing. Although best practices for polishing non-model de novo genome assemblies were recently described by the Vertebrate Genome Project (VGP) Assembly community, there is a need for a publicly available, reproducible workflow that can be easily implemented and run on a conventional high performance computing environment. Here, we describe polishCLR (https://github.com/isugifNF/polishCLR), a reproducible Nextflow workflow that implements best practices for polishing assemblies made from CLR data. PolishCLR can be initiated from several input options that extend best practices to suboptimal cases. It also provides re-entry points throughout several key processes, including identifying duplicate haplotypes in purge_dups, allowing a break for scaffolding if data are available, and throughout multiple rounds of polishing and evaluation with Arrow and FreeBayes. PolishCLR is containerized and publicly available for the greater assembly community as a tool to complete assemblies from existing, error-prone long-read data.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of sequencing depth in ChIP-seq experiments

In a chromatin immunoprecipitation followed by high-throughput sequencing (ChIP-seq) experiment, an important consideration in experimental design is the minimum number of sequenced reads required to obtain statistically significant results. We present an extensive evaluation of the impact of sequencing depth on identification of enriched regions for key histone modifications (H3K4me3, H3K36me3, H3K27me3 and H3K9me2/me3) using deep-sequenced datasets in human and fly. We propose to define sufficient sequencing depth as the number of reads at which detected enrichment regions increase <1% for an additional million reads. Although the required depth depends on the nature of the mark and the state of the cell in each experiment, we observe that sufficient depth is often reached at <20 million reads for fly. For human, there are no clear saturation points for the examined datasets, but our analysis suggests 40–50 million reads as a practical minimum for most marks. We also devise a mathematical model to estimate the sufficient depth and total genomic coverage of a mark. Lastly, we find that the five algorithms tested do not agree well for broad enrichment profiles, especially at lower depths. Our findings suggest that sufficient sequencing depth and an appropriate peak-calling algorithm are essential for ensuring robustness of conclusions derived from ChIP-seq data.

59 BASIC BIOLOGICAL SCIENCES↗

Residual Optically Stimulated Luminescent (OSL) Signals for Al 2 O 3 :C and a Readout System with Reproducible Partial Signal Clearance

Optically stimulated luminescent dosimeters (OSLDs) are devices that, when stimulated with light, emit light in proportion to the integrated ionizing radiation dose. The stimulation of OSL material results in the loss of a small fraction of signal stored within the dosimetric traps. Previous studies have investigated the signal loss due to readout stimulation, and the optical annealing of OSLDs. This study builds on former research by examining the behavior of OSL signal after annealing, exploring the functionality of a previously developed signal loss model, and comparing uncertainties for dosimeters reused with or without annealing. For a completely annealed dosimeter, the minimum signal level was 56 ± 8 counts, and readings followed a Gaussian distribution. For dosimeters above this signal level, the fractional signal loss due to the reading process has a linear relationship with the calculated signal. At low signal levels (below 20,000 counts), in this OSLD system,calculated signal percent errors increase significantly but otherwise are on average 0.72 ± 0.27%, 0.40 ± 0.19%, 0.33±0.12%, and 0.24±0.07% for 30, 75, 150, and 300 readings. Theoretical calculations of uncertainties showed that annealing before reusing dosimeters allows for dose errors below 1% with as few as 30 readings. Reusing dosimeters multiple times increases the dose errors especially with low numbers of readouts, so theoretically around 300 readings would be necessary to achieve errors around 1% or below in most scenarios. Note that these dose errors do not include the error associated with the signal-to-dose conversion factor.

61 RADIATION PROTECTION AND DOSIMETRY↗

Towards Scalable 3D Integration of 2T-nC FeRAM with Hundreds of Layer Stacking

In this article, we study the limits of the number of capacitors and read history dependence in a 2T-nC ferroelectric random-access memory (FeRAM) cell, paving the way for its high-density integration toward hundreds of stacked layers. Through a comprehensive experimental and simulation study on the scaling behavior of the 2T-nC FeRAM architecture, we demonstrate: (i) successful fabrication of 2T-64C cells with robust memory operation and clearly distinguishable ‘0’ and ‘1’ states, even in 64- capacitor configurations; (ii) that the parasitic capacitance of the floating node originates predominantly from the linear component of the ferroelectric capacitor, and its impact on n-scaling—due to degraded sense margin—can be mitigated by floating unselected capacitors with enough TΩ isolation; (iii) that sharing write and read transistors among n capacitors introduces a read history dependence issue due to fluctuating floating node voltage (VFN); and (iv) that a proposed FN discharge scheme can effectively eliminate read-sequence dependence, at the cost of reduced read endurance.

36 MATERIALS SCIENCE↗

SU-E-T-173: Evaluation of the MicroSTAR Reader for the OSLD System for Remote Dosimetry Audits at the IROC HQAC

Purpose: Analysis of the performance of the microSTARii reader for optically stimulated luminescence dosimeters (OSLD) used by the IROC Houston Quality Assurance Center (IROC HQAC) for external audits compare to the characteristics of the Microstar reader. Methods: The IROC HQAC uses the Microstar reader for the OSLD program for verification of output of photon, electron and proton beams. The calculation of dose from the OSLD system is based on a group of factors defined at time of the commissioning of a batch of detectors. Factors like system sensitivity (SS), depletion (KD), element correction factor (ECF), linearity (KL), energy correction (KE). The new microSTARii unit presents many hardware and software upgrades that were considered useful for this program. Based on these changes many factors, that were considered reader dependent, were revised in order to analyze the effect of the new reading process. The SS, KD, ECF and KL were evaluated and compared with data defined based on reading done on Microstar reader. Results: The SS is reader specific and specified at 100 cGy dose level. This value is define per reading session and monitored over time. The KD factor was found to be different because of reading procedure are different. The ECF values changed for a group of nano dots compare to values defined based on reading done on the Microstar reader. The KL was defined for the reader. Conclusion: The new microSTARii reader presents new features that improve the efficiency of the OSLD program at the IROC HQAC. New characterization is needed before final implementation is done to match the requirements of the existing OSLD system defined for the Microstar reader. Changes in uncertainty of the results has not been analized.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-222: Investigation of Pre and Post Irradiation Fading of the TLD100 Thermoluminescence Dosimetry for Photon Beams

Purpose: The pre-irradiation and post-irradiation fading of the Thermoluminescense dosimeter signals were investigated in this study. Methods: Two groups of TLD chips with pre-determined ECC values were used in this study. The two groups were divided into 6 series, each composing of 5 TLD chips.The first group was used for pre-irradiation fading. 5 TLDs were exposed to a known amount of radiation from Cs-137 source, and were read out the next day. After seven days, the other 5 TLDs were exposed to the same amount of radiation and were read out after a day. The other series of 5 TLDs were also exposed after 7,19,28, 59, and 90 days, and were read out a day after irradiation. The loss in TLD signal were obtained for all the above cases. The second group, was used for postirradiation fading. All the TLDs of this group were exposed to a known amount of radiation from Cs-137 source. The 6 series composed of 5 TLDs were read out after 1,7,19,28,59, and 90 days. The above-mentioned procedures for obtaining pre-irradiation, and post-irradiation fading were performed for three storage temperatures (25°C, 4°C, and −18°C). Results: According to the results obtained in this study, in case of pre-irradiation fading study, the signal losses after 90 days are 12%, 24%, and 17% for 25°C, 4°C, and −18°C respectively. In case of post-irradiation fading study, the sensitivity losses after 90 days are 25%, 216%, and 20% for 25°C, 4°C, and −18°C respectively. Conclusion: The results indicate that the optimized time between exposing and reading out, and also the optimized time between annealing and exposing is 1 day.The reduction of Storage temperature will reduce the post-irradiation fading, While temperature reduction does not have any effect on pre-irradiation fading.

60 APPLIED LIFE SCIENCES↗

TU-F-BRE-05: Experimental Determination of K Factor in Small Field Dosimetry

Purpose: Small-field dosimetry is challenging due to charged-particle disequilibrium, source occlusion and more importantly finite size of detectors. IAEA/AAPM has published approach to convert detector readings to dose by k factor. Manufacturers have been trying to provide various types of micro-detectors that could be used in small fields. However k factors depends on detector perturbations and are derived using Monte Carlo simulation. PTW has introduced a microDiamond for small-field dosimetry. An experimental approach is presented to derive the k factor for this detector. Methods: PTW microDiamond is a small volume detector with 1.1 mm radius and 1.0 micron thick synthetic diamond. Output factors were measured from 1×1cm2 to 12×12 cm2 on a Varian machine at various depths using various micro-detectors with published k factors. Dose is calculated as reading * K. Assuming k factor is accurate, output factor should be identical with every micro-detectors. Hence published k values (Francescon et al Med Phys 35, 504-513,2008) were used to covert readings and then output factors were computed. Based on the converged curve from other detectors, k factor for microDiamond was computed versus field size. Results: Traditional output factors as ratio of readings normalized to 10×10 cm2 differ significantly for micro-detectors for fields smaller than 3×3 cm2 which are now being used extensively. When readings are converted to dose, the output factor is independent of detector. Based on this method, k factor for microDiamond was estimated to be nearly constant 0.993±0.007 over varied field sizes. Conclusion: Our method provides a unique opportunity to determine the k factor for any unknown detector. It is shown that even though k factor depends on machine type due to focal spot, however for fields ≥1×1 cm2 this method provides accurate evaluation of k factor. Additionally microDiamond could be used with assumption that k factor is nearly unity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-CD-BRA-03: Direct Measurement of Magnetic Field Correction Factors, KQB, for Application in Future Codes of Practice for Reference Dosimetry

Purpose: With an MR-linac, radiation is delivered in the presence of a magnetic field. Modifications in the codes of practice (CoPs) for reference dosimetry are required to incorporate the effect of the magnetic field. Methods: In most CoPs the absorbed dose is determined using the well-known kQ formalism as the product of the calibration coefficient, the corrected electrometer reading and kQ, to account for the difference in beam quality. To keep a similar formalism a single correction factor is introduced which replaces kQ, and which corrects for beam quality and B-field, kQ,B. In this study we propose a method to determine kQ,B under reference conditions in the MRLinac without using a primary standard, as the product of:- the ratio between detector readings without and with B-field (kB),- the ratio between doses in the point of measurement with and without B-field (rho),- kQ in the absence of the B-field in the MRLinac beam (kQmrl0,Q0),The ratio of the readings, which covers the change in detector reading due to the different electron trajectories in the detector, was measured with a waterproof ionization chamber (IBA-FC65g) in a water phantom in the MRLinac without and with B-field. The change in dose-to-water in the point of measurement due to the B-field was determined with a Monte Carlo based TPS. Results: For the presented approach, the measured ratio of readings is 0.956, the calculated ratio of doses in the point of measurement is 0.995. Based on TPR20,10 measurements kQ was calculated as 0.989 using NCS-18. This yields a value of 0.9408 for kQ,B. Conclusion: The presented approach to determine kQ,B agrees with a method based on primary standards within 0.4% with an uncertainty of 1% (1 std.uncert). It differs from a similar approach using a PMMA-phantom and an NE2571 chamber with 1.3%.

60 APPLIED LIFE SCIENCES↗

A model for optimizing file access patterns using spatio-temporal parallelism. In: UltraVis '13 Proceedings of the 8th International Workshop on Ultrascale Visualization, Article No. 4

For many years now, I/O read time has been recognized as the primary bottleneck for parallel visualization and analysis of large-scale data. In this paper, we introduce a model that can estimate the read time for a file stored in a parallel filesystem when given the file access pattern. Read times ultimately depend on how the file is stored and the access pattern used to read the file. The file access pattern will be dictated by the type of parallel decomposition used. We employ spatio-temporal parallelism, which combines both spatial and temporal parallelism, to provide greater flexibility to possible file access patterns. Using our model, we were able to configure the spatio-temporal parallelism to design optimized read access patterns that resulted in a speedup factor of approximately 400 over traditional file access patterns.

Nouanesengsy, Boonthanome↗

ADEPT, a dynamic next generation sequencing data error-detection program with trimming

Illumina is the most widely used next generation sequencing technology and produces millions of short reads that contain errors. These sequencing errors constitute a major problem in applications such as de novo genome assembly, metagenomics analysis and single nucleotide polymorphism discovery. In this study, we present ADEPT, a dynamic error detection method, based on the quality scores of each nucleotide and its neighboring nucleotides, together with their positions within the read and compares this to the position-specific quality score distribution of all bases within the sequencing run. This method greatly improves upon other available methods in terms of the true positive rate of error discovery without affecting the false positive rate, particularly within the middle of reads. We conclude that ADEPT is the only tool to date that dynamically assesses errors within reads by comparing position-specific and neighboring base quality scores with the distribution of quality scores for the dataset being analyzed. The result is a method that is less prone to position-dependent under-prediction, which is one of the most prominent issues in error prediction. The outcome is that ADEPT improves upon prior efforts in identifying true errors, primarily within the middle of reads, while reducing the false positive rate.

59 BASIC BIOLOGICAL SCIENCES↗

Metagenomic analysis of planktonic microbial consortia from a non-tidal urban-impacted segment of James River

Knowledge of the diversity and ecological function of the microbial consortia of James River in Virginia, USA, is essential to developing a more complete understanding of the ecology of this model river system. Metagenomic analysis of James River's planktonic microbial community was performed for the first time using an unamplified genomic library and a 16S rDNA amplicon library prepared and sequenced by Ion PGM and MiSeq, respectively. From the 0.46-Gb WGS library (GenBank:SRR1146621; MG-RAST:4532156.3), 4 x 10 6 reads revealed >3 x 10 6 genes, 240 families of prokaryotes, and 155 families of eukaryotes. From the 0.68-Gb 16S library (GenBank:SRR2124995; MG-RAST:4631271.3; EMB:2184), 4 x 10 6 reads revealed 259 families of eubacteria. Results of the WGS and 16S analyses were highly consistent and indicated that more than half of the bacterial sequences were Proteobacteria , predominantly Comamonadaceae . The most numerous genera in this group were Acidovorax (including iron oxidizers, nitrotolulene degraders, and plant pathogens), which accounted for 10 % of assigned bacterial reads. Polaromonas were another 6 % of all bacterial reads, with many assignments to groups capable of degrading polycyclic aromatic hydrocarbons. Albidiferax (iron reducers) and Variovorax (biodegraders of a variety of natural biogenic compounds as well as anthropogenic contaminants such as polycyclic aromatic hydrocarbons and endocrine disruptors) each accounted for an additional 3% of bacterial reads. Comparison of these data to other publically-available aquatic metagenomes revealed that this stretch of James River is highly similar to the upper Mississippi River, and that these river systems are more similar to aquaculture and sludge ecosystems than they are to lakes or to a pristine section of the upper Amazon River. Altogether, these analyses exposed previously unknown aspects of microbial biodiversity, documented the ecological responses of microbes to urban effects, and revealed the noteworthy presence of 22 human-pathogenic bacterial genera (e.g., Enterobacteriaceae , pathogenic Pseudomonadaceae , and ‘Vibrionales' ) and 6 pathogenic eukaryotic genera (e.g., Trypanosomatidae and Vahlkampfiidae). This information about pathogen diversity may be used to promote human epidemiological studies, enhance existing water quality monitoring efforts, and increase awareness of the possible health risks associated with recreational use of James River.

54 ENVIRONMENTAL SCIENCES↗

FY11 Report on Metagenome Analysis using Pathogen Marker Libraries

A method, sequence library, and software suite was invented to rapidly assess whether any member of a pre-specified list of threat organisms or their near neighbors is present in a metagenome. The system was designed to handle mega- to giga-bases of FASTA-formatted raw sequence reads from short or long read next generation sequencing platforms. The approach is to pre-calculate a viral and a bacterial "Pathogen Marker Library" (PML) containing sub-sequences specific to pathogens or their near neighbors. A list of expected matches comparing every bacterial or viral genome against the PML sequences is also pre-calculated. To analyze a metagenome, reads are compared to the PML, and observed PML-metagenome matches are compared to the expected PML-genome matches, and the ratio of observed relative to expected matches is reported. In other words, a 3-way comparison among the PML, metagenome, and existing genome sequences is used to quickly assess which (if any) species included in the PML is likely to be present in the metagenome, based on available sequence data. Our tests showed that the species with the most PML matches correctly indicated the organism sequenced for empirical metagenomes consisting of a cultured, relatively pure isolate. These runs completed in 1 minute to 3 hours on 12 CPU (1 thread/CPU), depending on the metagenome and PML. Using more threads on the same number of CPU resulted in speed improvements roughly proportional to the number of threads. Simulations indicated that detection sensitivity depends on both sequencing coverage levels for a species and the size of the PML: species were correctly detected even at ~0.003x coverage by the large PMLs, and at ~0.03x coverage by the smaller PMLs. Matches to true positive species were 3-4 orders of magnitude higher than to false positives. Simulations with short reads (36 nt and ~260 nt) showed that species were usually detected for metagenome coverage above 0.005x and coverage in the PML above 0.05x, and detection probability appears to be a function of both coverages. Multiple species could be detected simultaneously in a simulated low-coverage, complex metagenome, and the largest PML gave no false negative species and no false positive genera. The presence of multiple species was predicted in a complex metagenome from a human gut microbiome with 1.9 GB of short reads (75 nt); the species predicted were reasonable gut flora and no biothreat agents were detected, showing the feasibility of PML analysis of empirical complex metagenomes.

59 BASIC BIOLOGICAL SCIENCES↗

A Two-Step PCR Protocol Enabling Flexible Primer Choice and High Sequencing Yield for Illumina MiSeq Meta-Barcoding

High-throughput amplicon sequencing that primarily targets the 16S ribosomal DNA (rDNA) (for bacteria and archaea) and the Internal Transcribed Spacer rDNA (for fungi) have facilitated microbial community discovery across diverse environments. A three-step PCR that utilizes flexible primer choices to construct the library for Illumina amplicon sequencing has been applied to several studies in forest and agricultural systems. The three-step PCR protocol, while producing high-quality reads, often yields a large number (up to 46%) of reads that are unable to be assigned to a specific sample according to its barcode. Here, we improve this technique through an optimized two-step PCR protocol. We tested and compared the improved two-step PCR meta-barcoding protocol against the three-step PCR protocol using four different primer pairs (fungal ITS: ITS1F-ITS2 and ITS1F-ITS4, and bacterial 16S: 515F-806R and 341F-806R). We demonstrate that the sequence quantity and recovery rate were significantly improved with the two-step PCR approach (fourfold more read counts per sample; determined reads ≈90% per run) while retaining high read quality (Q30 > 80%). Given that synthetic barcodes are incorporated independently from any specific primers, this two-step PCR protocol can be broadly adapted to different genomic regions and organisms of scientific interest.

16S rDNA↗