Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radio-frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Logistics Reduction: RFID Enabled Autonomous Logistics Management (REALM) (LR-REALM)

The Advanced Exploration Systems (AES) Logistics Reduction (LR) project Radio-frequency identification (RFID) Enabled Autonomous Logistics Management (REALM) task focuses on the subset of autonomous logistics management functions pertaining to automated localization and inventory of all physical assets pertaining to, or within, a vehicle utilizing RFID technologies. REALM technology can provide detailed data to enable autonomous operations such as automated crew procedure generation and robotic interaction with logistics and deep space habitats; this is especially of value where communication delays with Earth drive the need for self-reliance. The REALM project will conduct a series of ISS technology demonstrations. The first ISS demonstration, REALM-1, started in February 2017 and was completed at the end of FY19 when it was transitioned to the ISS program for sustaining operations. The second ISS demonstration, REALM-2, started late2019 and will continue for at least one year.

NASA TechPort↗

Retrieval of RFI Characteristics Using L-Band Satellite Data

Radio-frequency interference (RFI) has had a detrimental effect on L-band passive observatories such as SMOS, Aquarius and SMAP. A better knowledge of the characteristics of RFI signals might help mitigate this issue by leading to additional and better focused RFI detection algorithms and it might help identify RFI emitters on the ground. In this study we present approaches to retrieve some of the features of the RFI signals using SMAP data and we present some statistical considerations about the temporal and spectral characteristics of RFI sources.

Yan Soldo↗

A Spectrum Sensor for CubeSat Radios

Cube satellite (CubeSat) launches have increased exponentially over the last 20 years. This class of miniature spacecraft is well-suited for a set of nonconventional satellite architectures collectively known as formation flying. With the exponential pace of launches expected to continue, the prospect of spectrum management for these complex formations arises. In previous work, investigators focus on terrestrial applications of spectrum sensing, which have the luxury to utilize hardware with high size, weight, and power (SWaP) resources. In this work, we develop and test a spectrum sensor for CubeSat radio applications. Given that CubeSat radios are inherently designed for low SWaP, they cannot implement the computationally expensive spectral correlation analyzer (SCA) algorithms for signal detection. To that end, our investigation focuses on the application of the SCA to square-root-raised-cosine (SRRC) pulse-shaped quadrature amplitude modulation (QAM) waveforms using a field-programmable gate array (FPGA). This model requires no prior knowledge of the radio-frequency (RF) channel. We show that this model can consistently and accurately detect the symbol rate and center frequencies of waveforms located in a spectrum.

cubesat↗

Microwave Radiometry at Frequencies From 500 to 1400 MHz: An Emerging Technology for Earth Observations

Microwave radiometry has provided valuable spaceborne observations of Earth's geophysical properties for decades. The recent SMOS, Aquarius, and SMAP satellites have demonstrated the value of measurements at 1400 MHz for observing surface soil moisture, sea surface salinity, sea ice thickness, soil freeze/thaw state, and other geophysical variables. However, the information obtained is limited by penetration through the subsurface at 1400 MHz and by a reduced sensitivity to surface salinity in cold or wind-roughened waters. Recent airborne experiments have shown the potential of brightness temperature measurements from 500–1400 MHz to address these limitations by enabling sensing of soil moisture and sea ice thickness to greater depths, sensing of temperature deep within ice sheets, improved sensing of sea salinity in cold waters, and enhanced sensitivity to soil moisture under vegetation canopies. However, the absence of significant spectrum reserved for passive microwave measurements in the 500–1400 MHz band requires both an opportunistic sensing strategy and systems for reducing the impact of radio-frequency interference. Here, we summarize the potential advantages and applications of 500–1400 MHz microwave radiometry for Earth observation and review recent experiments and demonstrations of these concepts. We also describe the remaining questions and challenges to be addressed in advancing to future spaceborne operation of this technology along with recommendations for future research activities.

microwave radiometry↗

Lightweight Composite Reflectarray That Can Be Flattened, Folded, and Coiled for Compact Stowage

Herein is presented a design for a lightweight 5m 1m radio-frequency (RF) re ector that can be attened, folded, and coiled for compact stowage on board an ESPA-class spacecraft. The re ector is a re ectarray that operates at 3.2GHz. Compared to state- of-the-art technologies for RF re ectors, the presented design has advantages in terms of areal density, sti ness, deployed stability, and scalability. Thermal and structural analysis is presented to demonstrate deployed sti ness and thermoelastic stability of the proposed design. Thermal analysis is used to predict in- space deployed temperatures in an operational condition, and structural nite element analysis is used to predict deployed vibration modes and frequencies, and the thermoelastic deformation of the deployed re ector. Also presented are the fabrication, assembly, and testing of two one-third-scale-length full-scale-width 1:7m 1m test articles. These test articles are used to experimentally demonstrate RF functioning, stowage, deployment, and RF performance after deployment.

Pellegrino, Sergio↗

High Altitude Re-entry Plasma Emulation Experiment (HARPEE)

A table-top apparatus has recently been constructed at the NASA Glenn Research Center to investigate potential solutions for the radio-frequency communication blackout problem -- experienced by landing modules during high-speed atmospheric entry. This customized plasma chamber was designed to emulate Earth-based atmospheric entry plasmas with electron densities in the range of 10^16 m^-3 to 10^19 m^-3. The system makes use of a 40-kHz, perforated coaxial electrode pair to generate a disk-shaped, static plasma with an approximate diameter and thickness of 405 mm and 100 mm, respectively. A translatable Langmuir probe was employed to characterize the radial profile of electron temperature and density as a function the 40-kHz power (< 1 kW) and dry-nitrogen flow rate (< 160 SCCM).

plasma↗

RF Characterization of a Photocurable PEDOT:PSS:PEGDA Conductive Biomaterial for 3D-Printing Implantable Antennas

In this work, we demonstrate photocurable PEDOT:PSS:PEGDA biomaterial as a promising candidate for intracorporeal 3D printing. Intracorporeal 3D printing offers a less invasive method which offer flexibility to tailor the form factor of printed structures. Previous work has demonstrated the feasibility of a robotic probe to 3D-print biological tissues intracorporeally via a minor incision. This same probe could also 3D-print implantable antennas as long as a suitable conductive material is identified in terms of conductivity, biocompatibility, and ability to cure at room/body temperature for safety purposes. We assess the frequency-dependent conductivity of this biomaterial and explore the Radio-Frequency (RF) performance of resulting antennas operating in free-space and inside tissue-emulating phantoms. Results show that PEDOT:PSS biomaterial with 21% and 30% PEGDA content exhibit a conductivity of ~10 4 S/m up to 5 GHz, suitable for wireless implants. Comparing the two, 21% PEGDA content exhibits poorer curing abilities, while 30% PEGDA exhibits slightly lower conductivity. Measurements for 2.4 GHz free-space dipoles conducted in an anechoic chamber reveal only ~0.8 dB and ~1 dB lower gain for PEDOT:PSS:21%PEGDA and PEDOT:PSS:30%PEGDA biomaterial, respectively, as compared to their copper counterpart. For a 5 mm-deep implanted patch antenna, these two biomaterials exhibit 3.05 dB and 3.84 dB higher transmission loss than copper, respectively. If deemed necessary, this performance degradation can be overcome by increasing the overall antenna size since the printing process is now minimally invasive and miniaturization requirements can be relaxed.

3D-printing↗

Automated Detection of Spurious Signals in VLBI Phase Calibration Data

In this memorandum, a set of processing strategies for automatic masking of phase calibration tones is outlined as implemented in the software package PIMA in the task Generate Phase Calibration Mask, or GEPM. The task relies on a robust procedure of cleaning phase calibration data before employing several mathematical strategies designed to selectively identify spurious signals from phase calibration tones. These strategies were derived as more rigorous implementations of heuristics traditionally used by analysts in manually identifying problematic phase calibration data. The task is intended to automate the process of generating a phase calibration mask and in so doing increase the speed and regularity of VLBI analysis. At the outset of the project, a series of goals were identified to evaluate the success of this mask generation. This included the development of an algorithm to identify and mask short-term (defined as less than 10 seconds in length) spurious signals affecting phase calibration data, the development of an algorithm to identify and mask phase calibration tones affected by constant radio-frequency interference, the implementation of a detection scheme for identifying large jumps in phase calibration phase caused by clock breaks, and finally a method of reporting phase calibration health metrics to the user. Processing of over 10 experiments has demonstrated that the final form of the task GEPM as detailed in this technical memorandum satisfies each of these conditions and satisfactorily performs the task of automatic phase calibration data masking, although the wide variety in quality and characteristics of phase calibration data makes a single solution to the problem quite difficult. A series of user inputs have therefore been defined to assist analysts in tailoring automatic masking to specific stations and phase calibration generators. The vast majority of applicable code was written in FORTRAN to increase execution speed and ease of interfacing with the existing code base in PIMA, but a wrapper function in Python was also written to allow for a simpler method of interacting with GEPM and inputting relevant parameters. In addition to this report, thorough documentation was added to the already existing repositories associated with PIMA as a whole.

Geodesy↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

Design and optimization of higher order mode couplers for the superconducting cavities of the PERLE energy recovery linac

The Powerful Energy Recovery Linac for Experiments (PERLE) is an energy recovery linac (ERL) facility based on superconducting radio-frequency (SRF) technology to be hosted at the Laboratoire de Physique des 2 Infinis Irène Joliot-Curie (IJCLab) in France. With a target beam power of 10 MW, PERLE aims to demonstrate the high-current, continuous wave, multi-pass operation to validate options for future high-energy machines, such as the 50 GeV ERL proposed for the Large Hadron electron Collider (LHeC) and the Future Circular electron-hadron Collider (FCC-eh), and host dedicated particle physics and nuclear experiments. In high-current ERLs, the regenerative Beam Breakup (BBU), emerging from the beam and cavity Higher Order Modes (HOMs) interaction, is a major concern for their stable operation. Beam-induced HOMs can increase the cavity heat load at cryogenic temperature and cause beam instabilities. HOM couplers are installed in the cavity beam pipes to absorb HOM energy and mitigate these effects. This thesis presents the design and optimization of several coaxial HOM couplers for the 5-cell 801.58 MHz elliptical Nb cavities of the 500 MeV PERLE ERL configuration. The RF transmission of the HOM couplers was optimized to enhance the damping of the most dangerous HOMs. The optimized HOM couplers were integrated into endgroups to simulate their damping performance and thermal behavior. The optimized HOM couplers were 3D-printed in epoxy and copper-coated. Low-power RF measurements were conducted on the produced HOM couplers installed in copper PERLE-type cavities to validate their damping performance and propose several endgroups for the PERLE 5-cell cavity to mitigate HOMs below the BBU instability limits.

Barbagallo, Carmelo↗

Coming Closer to High Frequency Gravitational Wave Detection With MAGO

In the last years, low frequency gravitational waves (GWs) have been consistently measured by the LIGO&#x2;Virgo collaboration, but little to no attention has been paid to higher frequencies GWs in the range of 10 kHz to 100 MHz, at which confirmation for current theories or even new physics could be hidden. The MAGO 2.0 project aims at filling this gap in the parameter space using superconducting radio-frequency (SRF) cavities. Exploiting the excellent Q-factors of these resonators, we plan to detect tiny harmonic deformations induced by GWs which change the boundary conditions of the oscillating electromagnetic field. We present the results of the first cold tests ran at DESY and FNAL using the cavity prototype built 20 years ago at the end of the MAGO collaboration, characterizing the RF spectrum, Q-factor and surface resistance. Additionally we introduce the mechanical vibration spectrum characterization and the RF response of the cavity with the injection of a “fake GW” signal using piezoelectric actuators.

Marconato, Giovanni [Hamburg U.]↗

Quantum Enhanced Dark-Matter Search with Entangled Fock States in High-Quality Cavities

We present a quantum-enhanced protocol for detecting wave-like dark matter using an array of $N$ entangled superconducting cavities initialized in an $m$-photon Fock state. By distributing and recollecting the quantum state with an entanglement-distribution operation, the scan rate scales as $N^2(m+1)$ while thermal excitation is the dominant background, significantly outperforming classical single-cavity methods under matched conditions. We evaluate the robustness of our scheme against additional noise sources, including decoherence and beamsplitter infidelity, through theoretical analysis and numerical simulations. In practice, the key requirements, namely high-Q superconducting radio-frequency cavities that support long integration times, high-fidelity microwave beamsplitters, and universal cavity control, are already available on current experimental platforms, making the protocol experimentally feasible.

Freiman, Benjamin [Fermilab]↗

Improving the performance of mid-T baked niobium cavities through post-bake surface treatment

The Medium temperature (mid-T) baking of niobium superconducting radio-frequency cavities at 300 350 C in a vacuum furnace is known to enhance the quality factor (Q₀). However, despite this improvement, cavities treated with this process often exhibit premature quench at relatively low accelerating fields. This limitation is suspected to arise from the formation of surface contaminants, such as niobium carbides, during the furnace bake at 350 C for 3 h. To investigate the influence of potential surface contamination, this study applied an ultralight chemical removal to 1.3 GHz and 650 MHz single-cell cavities that had undergone medium-temperature baking. The removal of the top RF surface layer led to a notable improvement in the quench field and Q₀, indicating a beneficial effect of eliminating possible surface residues introduced during the bake.

Chouhan, V. [Fermilab] (ORCID:0000000282004931)↗

IOTA Experiment for Proton Pulse Compression at Extreme Space-Charge

The longitudinal compression of high-intensity, space-charge-dominated proton bunches is a critical requirement for future proton-driven muon colliders. We propose a proton bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to investigate optimal radio-frequency (RF) cavity parameters and lattice configurations. IOTA is a compact, fixed-energy storage ring dedicated to beam physics Research and Development and capable of circulating a 2.5 MeV proton beam under extreme space-charge conditions. Using the ImpactX code with its 3D space-charge solver, simulations indicate that the bunch length can be rapidly reduced by at least a factor of two without appreciable degradation of transverse beam quality--even in the strong space-charge regime. However, longitudinal defocusing due to the space-charge remains a significant challenge in short-pulsed intense proton bunches, and the optimization of compression under these conditions is discussed.

Simons, B. D. [Northern Illinois U.]↗

Machine Learning for Multipactor Susceptibility Prediction in Planar RF Gaps

Multipactor discharge is a nonlinear electron avalanche that limits the performance of high-power radio-frequency (RF) and vacuum electronic devices. Predicting multipactor susceptibility traditionally relies on Monte Carlo or particle-in-cell (PIC) simulations, which become computationally expensive for large parametric studies. In this work, we present a supervised machine-learning (ML) framework for prediction of multipactor susceptibility in a two-surface planar geometry. The models are trained using high-fidelity PIC simulation generated susceptibility data and learn the relationship between operational parameters, geometry, and material-dependent secondary electron emission properties. The proposed approach enables rapid reconstruction of susceptibility charts while preserving the physical structure of multipactor growth regions.

43 PARTICLE ACCELERATORS↗

Cryogenic RF characterization of the MAGO cavity for high-frequency gravitational-wave detection

Superconducting radio-frequency (SRF) cavities are promising resonant sensors for gravitational-wave detection in the kHz-MHz frequency range. We report the cryogenic RF characterization of a prototype superconducting niobium cavity with an unconventional geometry designed for narrow electromagnetic mode separation. Following an adapted surface preparation procedure, cryogenic tests were performed at Fermilab and DESY at temperatures down to 2 K. Mechanical tuning at room temperature achieved a mode splitting of approximately 11 kHz at cryogenic temperature. High electromagnetic quality factors consistent with previous prototype cavities were measured. The measurements further revealed phase transfer characteristics relevant for stable low-level RF control as well as indications of mode coupling potentially caused by one-point multipacting. In addition, first cryogenic measurements of the mechanical eigenmodes yielded mechanical quality factors significantly below commonly assumed theoretical values. These results demonstrate the successful application of established SRF preparation and characterization techniques to a non-standard resonator geometry and provide important experimental input for the development of future SRF-based gravitational-wave detectors.

Dokuyucu, Can [DESY]↗