Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Radiation Chemistry 2008 Gordon Research Conference - July 6-11, 2008

Radiation Chemistry is chemistry initiated by ionizing radiation: i.e. photons or particles with energy sufficient to create charge pairs and/or free radicals in a medium. The important transients include conduction band electrons and 'holes', excitons, ionic and neutral free radicals, highly excited states, and solvated electrons. Effects of radiation span timescales from the energy deposition in femtoseconds, through geminate recombination in picoseconds and nanoseconds, to fast radical chemistry in microseconds and milliseconds, and ultimately to processes like cancer occurring decades later. The radiation sources used to study these processes likewise run from femtosecond lasers to nanosecond accelerators to years of gamma irradiation. As a result the conference has a strong interdisciplinary flavor ranging from fundamental physics to clinical biology. While the conference focuses on fundamental science, application areas highlighted in the present conference will include nuclear power, polymer processing, and extraterrestrial chemistry.

99 GENERAL AND MISCELLANEOUS↗

Study of the influence of glucose on diffuse reflection of ultrashort laser pulses from a medium simulating a biological tissue

The influence of glucose on the diffuse reflection of near-IR femtosecond laser radiation from single- and three-layer media simulating biological tissues is studied experimentally. Based on a 800-nm femtosecond Ti:sapphire laser emitting 40-fs pulses and a VUV Agat streak camera, a setup is built for time and spatially resolved detection of radiation diffusely reflected from the volume of a strongly scattering medium. A multichannel fibreoptic system is developed for detecting pulses simultaneously at several fixed distances between a radiation source and detector. It is shown that the peak intensity and total energy of detected pulses are sensitive to variations in the glucose concentration in the medium under study from 0 to 1000 mg dL{sup -1}. The relative sensitivity in our experiments achieved 0.030% mg dL{sup -1}. (biophotonics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methods for aligning a spectrometer

An example method for aligning a spectrometer is described herein. The spectrometer includes a radiation source, a crystal analyzer, and a detector that are all positioned on an instrument plane. The method includes rotating the crystal analyzer about an axis that is within the instrument plane and perpendicular to a rotation plane such that (i) a reciprocal lattice vector of the crystal analyzer is within the instrument plane or (ii) a component of the reciprocal lattice vector within the rotation plane is perpendicular to the instrument plane. An origin of the reciprocal lattice vector is located on the axis. The method further includes tilting the crystal analyzer or translating the detector such that the reciprocal lattice vector bisects a line segment that is bounded by the detector and the radiation source. Example spectrometers related to the example method are also disclosed.

Mortensen, Devon R.↗

PHOTOIONIZED FEATURES IN THE X-RAY SPECTRUM OF EX HYDRAE

We present the first results from a long (496 ks) Chandra High Energy Transmission Grating observation of the intermediate polar EX Hydrae (EX Hya). In addition to the narrow emission lines from the cooling post-shock gas, for the first time we have detected a broad component in some of the X-ray emission lines, namely, O VIII lambda18.97, Mg XII lambda8.42, Si XIV lambda6.18, and Fe XVII lambda16.78. The broad and narrow components have widths of {approx}1600 km s{sup -1} and {approx}150 km s{sup -1}, respectively. We propose a scenario where the broad component is formed in the pre-shock accretion flow, photoionized by radiation from the post-shock flow. Because the photoionized region has to be close to the radiation source in order to produce strong photoionized emission lines from ions such as O VIII, Fe XVII, Mg XII, and Si XIV, our photoionization model constrains the height of the standing shock above the white dwarf surface. Thus, the X-ray spectrum from EX Hya manifests features of both magnetic and non-magnetic cataclysmic variables.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of Charge Transport Properties of CdZnTe Detectors with Synchrotron X-ray Radiation

Various internal defects, such as Te inclusions, twin boundaries, dislocation, etc., are prevalent in as-grown CdZnTe (CZT) crystals, which affect the charge transport properties of CZT crystals and, therefore, worsen the performance of CZT detectors. In order to develop high quality CZT detectors, it is imperative to clarify the effects of internal defects on the charge transport properties of CZT. Simple flood illumination with nuclear radiation source cannot reveal the nature of highly localized defects in CZT. Therefore, at Brookhaven's National Synchrotron Light Source (NSLS), we have developed a unique testing system for micro-scale defect investigation of CZT, which employs an X-ray beam collimated with the spatial resolution as small as 3 x 3 {micro}m{sup 2}, a microscopic size comparable to the scale of common defects in CZT. This powerful tool enables us to investigate the effect of internal defects on charge transport properties of CZT in detail.

43 PARTICLE ACCELERATORS↗

X-ray and EUV Emission Studies of Copper Vacuum Spark Plasma

A vacuum spark system with a copper anode and electrode of gap 1.5 mm is investigated for the purpose of developing it as a possible radiation source for Next Generation Lithography (NGL). At discharge voltage in the range of 10 to 15 kV and an ambient pressure of about 10{sup -3} mbar, both X-ray (measured by PIN diode) and extreme ultraviolet, EUV (measured by SXUV5A with integrated filter) can be measured simultaneously when good pinching discharge as indicated by sharp dip in the waveform of the rate of current is achieved. For discharge with mild pinching, only EUV emission is observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high-resolution inelastic X-ray scattering at high-repetition-rate self-seeded X-ray free-electron lasers

Inelastic X-ray scattering (IXS) is an important tool for studies of equilibrium dynamics in condensed matter. A new spectrometer recently proposed for ultra-high-resolution IXS (UHRIX) has achieved 0.6 meV and 0.25 nm -1 spectral and momentum-transfer resolutions, respectively. However, further improvements down to 0.1 meV and 0.02 nm -1 are required to close the gap in energy–momentum space between high- and low-frequency probes. It is shown that this goal can be achieved by further optimizing the X-ray optics and by increasing the spectral flux of the incident X-ray pulses. UHRIX performs best at energies from 5 to 10 keV, where a combination of self-seeding and undulator tapering at the SASE-2 beamline of the European XFEL promises up to a 100-fold increase in average spectral flux compared with nominal SASE pulses at saturation, or three orders of magnitude more than what is possible with storage-ring-based radiation sources. Wave-optics calculations show that about 7 × 10 12 photons s -1 in a 90 µeV bandwidth can be achieved on the sample. This will provide unique new possibilities for dynamics studies by IXS.

inelastic X-ray scattering↗

A Paris-Edinburgh Cell for High-Pressure and High-Temperature Structure Studies on Silicate Liquids Using Monochromatic Synchrotron Radiation

A Paris-Edinburgh press combined with a multi-channel collimator assembly has been commissioned at the GeoSoilEnviro Center for Advanced Radiation Sources (GSECARS) beamline for monochromatic X-ray scattering, with an emphasis on studying low-Z liquids, especially silicate liquids at high pressure. The Paris-Edinburgh press is mounted on a general-purpose diffractometer, with a pixel array detector mounted on the detector arm. The incident monochromatic undulator beam with energies up to 60 keV is focused both horizontally and vertically to a beam size about 30 × 30 µm. With this setup, background scattering from the surrounding pressure media is completely removed at 2θ angles above 10° for samples larger than 1.05 mm in diameter. Thirty minutes is typically sufficient to collect robust X-ray scattering signals from a 1.6 mm diameter amorphous silicate sample. Cell assemblies for the standard Paris-Edinburgh anvils have been developed and pressures and temperatures up to 7 GPa and 2300 K, respectively, have been maintained steadily over hours. We have also developed a cupped-toroidal Drickamer anvil to further increase pressure and temperature capabilities. The cupped-toroidal Drickamer anvil combines features of a modified Drickamer anvil and the traditional Paris-Edinburgh anvil. Pressures up to 12 GPa have been generated at temperatures up to 2100 K.

58 GEOSCIENCES↗

Conference Comments by the Editors

The Symposium on Radiation Measurements and Applications (SORMA) met for the first time on the West Coast June 2-5, 2008, in Berkeley, CA. With radiation detectors increasing in number, variety, and societal importance, we plan to alternate between SORMA East (in Ann Arbor, MI) and SORMA West so that the forum will be available every two years. The topic areas for SORMA West 2008 were much the same as those of recent Ann Arbor programs, and were meant to encompass the full breadth of ionizing radiation measurement applications and technologies, with both oral and poster presentations. The technical program of SORMA 2008 included 342 scientific presentations, 116 oral presentations plus eight invited keynote lectures in plenary sessions, as well as 218 presentations in poster sessions. The SORMA 2008 meetings were attended by 439 registered participants from 25 different countries. Topics of interest at the meeting ranged from room temperature semiconductor detectors, cryogenic detectors, photodetectors, neutron detectors, novel scintillators, nonproportionality and characterization of scintillators, simulation and analysis of radiation interactions, novel radiation sources, imaging technologies and homeland security and medical applications. This was the first conference of the SORMA series to be technically cosponsored by the Institute of Electrical and Electronic Engineers (IEEE), specifically by the Nuclear and Plasma Sciences Society (NPSS) of IEEE. The co-sponsorship has been important for visibility of SORMA and for attracting a record number of new participants. This special issue of IEEE TRANSACTIONS ON NUCLEAR SCIENCE comprises the refereed proceedings of SORMA 2008, containing 128 papers on the research presentations. The Chairs of the SORMA 2008 conference would like to acknowledge partial financial support from the NNSA, DNDO, and DTRA, and organizational support from Lawrence Berkeley National Laboratory and Lawrence Livermore National Laboratory. We acknowledge our corporate supporters: Caen Nuclear, Eljen Technology, Hilger Crystals and GE Global Research. Finally, we thank the members of the local organizing committee: Diana Attila, Thomas Budinger, Joe Chew, Daniel Chivers, Rob Johnson, Laurie O'Brien, Donna Raziano, Emily Sause, and Brian Wirth for doing all the work that actually made this conference happen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

INTERRUPTION OF TIDAL-DISRUPTION FLARES BY SUPERMASSIVE BLACK HOLE BINARIES

Supermassive black hole binaries (SMBHBs) are products of galaxy mergers, and are important in testing LAMBDA cold dark matter cosmology and locating gravitational-wave-radiation sources. A unique electromagnetic signature of SMBHBs in galactic nuclei is essential in identifying the binaries in observations from the IR band through optical to X-ray. Recently, the flares in optical, UV, and X-ray caused by supermassive black holes (SMBHs) tidally disrupting nearby stars have been successfully used to observationally probe single SMBHs in normal galaxies. In this Letter, we investigate the accretion of the gaseous debris of a tidally disrupted star by a SMBHB. Using both stability analysis of three-body systems and numerical scattering experiments, we show that the accretion of stellar debris gas, which initially decays with time propor tot {sup -5/3}, would stop at a time T{sub tr} approx = etaT{sub b}. Here, eta approx 0.25 and T{sub b} is the orbital period of the SMBHB. After a period of interruption, the accretion recurs discretely at time T{sub r} approx = xi{sub b}, where xi approx 1. Both eta and xi sensitively depend on the orbital parameters of the tidally disrupted star at the tidal radius and the orbit eccentricity of SMBHB. The interrupted accretion of the stellar debris gas gives rise to an interrupted tidal flare, which could be used to identify SMBHBs in non-active galaxies in the upcoming transient surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Hydrogen Bonding in Proteins and Water Studied by Far-IR and Low-Wavenumber Raman Spectroscopy

Far-IR spectra with a synchrotron radiation source were for the first time recorded through a microscope coupled to an FTIR-spectrometer. A comparison with spectra recorded with an ordinary globar source revealed that no artifacts occurred with synchrotron radiation. A comparison of ATR (Si-prism) and transmission spectra of a tetrapeptide showed that the ATR-microscope technique could be applied. ATR- and transmission spectra were recorded of polyglycine and compared to the low wavenumber Raman spectrum in the R(v)-representation. A protein band at 115-125 cm{sup -1} was assigned to hydrogen bond modes. Collectively these modes might drive conformational changes in proteins. Based mainly on previously published results the determination of water with a structure like that in bulk liquid water was performed for human and animal skin samples. Changes in water content were reported for freezing and thawing of human skin biopsies and for human skin with benign or malignant skin diseases.

60 APPLIED LIFE SCIENCES↗

Solving Inverse Radiation Transport Problems with Multi-Sensor Data in the Presence of Correlated Measurement and Modeling Errors

Inverse radiation transport focuses on identifying the configuration of an unknown radiation source given its observed radiation signatures. The inverse problem is traditionally solved by finding the set of transport model parameter values that minimizes a weighted sum of the squared differences by channel between the observed signature and the signature predicted by the hypothesized model parameters. The weights are inversely proportional to the sum of the variances of the measurement and model errors at a given channel. The traditional implicit (often inaccurate) assumption is that the errors (differences between the modeled and observed radiation signatures) are independent across channels. Here, an alternative method that accounts for correlated errors between channels is described and illustrated using an inverse problem based on the combination of gamma and neutron multiplicity counting measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Provisional standards of radiation safety of flight personnel and passengers in air transport of the civil aviation

Provisional standards for radiation affecting passenger aircraft are considered. Agencies responsible for seeing that the regulations are enforced are designated while radiation sources and types of radiation are defined. Standard levels of permissible radiation are given and conditions for radiation safety are discussed. Dosimetric equipment on board aircraft is delineated and regulation effective dates are given.

Source record↗

Cryogenic Blackbody-Radiation Calibration Source

Operating temperatures range from ambient down to minus 100 degrees C. V-grooved front face of source body blackened and recessed in black sleeve. Semiairtight chamber that houses source purged with dry nitrogen gas to prevent formation of dew or frost at low operating temperature.

Burkett, Cecil G., Jr.↗

DE 1 particle and wave observations in Auroral Kilometric Radiation (AKR) source regions

The high-altitude plasma instrument on board the DE 1 satellite was operating during several near crossings of the AKR source in the nightside auroral region. Observations of electron distributions indicate a region of perpendicular heating adjacent to, and within, the source region. Loss cones, trapped particles, beams, and electron conical distributions are also observed near and within the source region, which extends perpendicular to the magnetic field line for at least 20 km. Near the AKR source region wave-particle interactions appear to have modified the observed electron distributions. We compare the observations to those predicted by recently published numerical simulations.

Menietti, J. D.↗

Method and Apparatus for Polaradiometric Pyrometer

A radiation pyrometer for measuring the true temperature of a body is provided by detecting and measuring thermal radiation from the body based on the principle that the effects of angular emission I(sub 1) and reflection I(sub 2) on the polarization states p and s of radiation are complementary such that upon detecting the combined partial polarization state components I(sub p) = I(sub 1p) + I(sub 2p) and I(sub s) = I(sub 1s) + I(sub 2s) and adjusting the intensity of the variable radiation source of the reflected radiation I(sub 2) until the combined partial radiation components I(sub p) and I(sub s) are equal, the effects of emissivity as well as diffusivity of the surface of the body are eliminated, thus obviating the need for any post processing of brightness temperature data.

Abtahi, Ali A.↗