Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

SU-D-202-01: Functional Lung Avoidance and Response-Adaptive Escalation (FLARE) RT: Feasibility of a Precision Radiation Oncology Strategy

Purpose: NSCLC patient RT is planned without consideration of spatial heterogeneity in lung function or tumor response, which may have contributed to failed uniform dose escalation in a randomized trial. The feasibility of functional lung avoidance and response-adaptive escalation (FLARE) RT to reduce dose to [{sup 99m}Tc]MAA-SPECT/CT perfused lung while redistributing 74Gy within [{sup 18}F]FDG-PET/CT biological target volumes was assessed. Methods: Eight Stage IIB–IIIB NSCLC patients underwent FDG-PET/CT and MAA-SPECT/CT treatment planning scans. Perfused lung objectives were derived from scatter/collimator/attenuation-corrected MAA-SPECT uptake relative to ITV-subtracted lung to maintain <20Gy mean lung dose (MLD). Prescriptions included 60Gy to PTV and concomitant boost of 74Gy mean to biological target volumes (BTV=GTV+PET margin) scaled to each BTV voxel by relative FDG-PET SUV. Dose-painting-by-numbers prescriptions were integrated into commercial TPS via previously reported ROI discretization. Dose constraints for lung, heart, cord, and esophagus were defined. FLARE RT plans were optimized with VMAT, proton pencil beam scanning (PBS) with 3%-3mm robust optimization, and combination PBS (avoidance) plus VMAT (escalation). Dosimetric differences were evaluated by Friedman non-parametric paired test with multiple sampling correction. Results: PTV and normal tissue objectives were not violated in 24 FLARE RT plans. Population median of mean BTV dose was 73.7Gy (68.5–75.5Gy), mean FDG-PET peak dose was 89.7Gy (73.5–103Gy), MLD was 12.3Gy (7.5–19.6Gy), and perfused MLD was 4.8Gy (0.9–12.1Gy). VMAT achieved higher dose to the FDG-PET peak subvolume (p=0.01), while PBS delivered lower dose to lung (p<0.001). Voxelwise linear correlation between BTV dose and FDG-PET uptake was higher for VMAT (R=0.93) and PBS+VMAT (R=0.94) compared to PBS alone (R=0.89). Conclusion: FLARE RT is feasible with VMAT and PBS. A combination of PBS for functional lung avoidance and VMAT for FDG-PET dose escalation balances target/normal tissue objective tradeoffs. These results support future testing of FLARE RT safety and efficacy within a precision radiation oncology trial. This work was supported by a Research Scholar grant from the Radiological Society of North American Research & Education Foundation.

60 APPLIED LIFE SCIENCES↗

SU-D-207A-03: Potential Role of BOLD MRI in Discrimination of Aggressive Tumor Habitat in Prostate Cancer

Purpose: To determine whether blood oxygenation level dependent (BOLD) MRI signal measured in prostate cancer patients, in addition to quantitative diffusion and perfusion parameters from multiparametric (mp)MRI exams, can help discriminate aggressive and/or radioresistant lesions. Methods: Several ongoing clinical trials in our institution require mpMRI exam to determine eligibility (presence of identifiable tumor lesion on mpMRI) and prostate volumes for dose escalation. Upon consent, patients undergo fiducial markers placement and a T2*-weighted imaging at the time of CT sim to facilitate the fusion. In a retrospective analysis eleven clinical trial patients were identified who had undergone mpMRI on GE 3T magnet, followed by T2*-weighted imaging (time-period mean±SD = 48±20 days) using a consistent protocol (gradient echo, TR/TE=30/11.8ms, flip angle=12, matrix=256×256×75, voxel size=1.25×1.25×2.5mm). ROIs for prostate tumor lesions were automatically determined using ADC threshold ≤1200 µm2/s. Although the MR protocol was not intended for BOLD analysis, we utilized the T2*-weighted signal normalized to that in nearby muscle; likewise, T2-weighted lesion signal was normalized to muscle, following rigid registration of the T2 to T2* images. The ratio of these normalized signals, T2*/T2, is a measure of BOLD effect in the prostate tumors. Perfusion parameters (Ktrans, ve, kep) were also calculated. Results: T2*/T2 (mean±SE) was found to be substantially lower for Gleason score (GS) 8&9 (0.82±0.04) compared to GS 7 (1.08±0.07). A k-means cluster analysis of T2*/T2 versus kep = Ktrans/ve revealed two distinct clusters, one with higher T2*/T2 and lower kep, containing only GS 7 lesions, and another with lower T2*/T2 and higher kep, associated with tumor aggressiveness. This latter cluster contained all GS 8&9 lesions, as well as some GS 7. Conclusion: BOLD MRI, in addition to ADC and kep, may play a role (perhaps orthogonal to Gleason score) in identifying prostate lesions that would benefit from more aggressive radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-E-10: Student-Driven Exploration of Radiographic Material Properties, Phantom Construction, and Clinical Workflows Or: The Extraordinary Life of CANDY MAN

Purpose: To develop a hands-on learning experience that explores the radiological and structural properties of everyday items and applies this knowledge to design a simple phantom for radiotherapy exercises. Methods: Students were asked to compile a list of readily available materials thought to have radiation attenuation properties similar to tissues within the human torso. Participants scanned samples of suggested materials and regions of interest (ROIs) were used to characterize bulk attenuation properties. Properties of each material were assessed via comparison to a Gammex Tissue characterization phantom and used to construct a list of inexpensive near-tissue-equivalent materials. Critical discussions focusing on samples found to differ from student expectations were used to revise and narrow the comprehensive list. From their newly acquired knowledge, students designed and constructed a simple thoracic phantom for use in a simulated clinical workflow. Students were tasked with setting up the phantom and acquiring planning CT images for use in treatment planning and dose delivery. Results: Under engineer and physicist supervision, students were trained to use a CT simulator and acquired images for approximately 60 different foodstuffs, candies, and household items. Through peer discussion, students gained valuable insights and were made to review preconceptions about radiographic material properties. From a subset of imaged materials, a simple phantom was successfully designed and constructed to represent a human thorax. Students received hands-on experience with clinical treatment workflows by learning how to perform CT simulation, create a treatment plan for an embedded tumor, align the phantom for treatment, and deliver a treatment fraction. Conclusion: In this activity, students demonstrated their ability to reason through the radiographic material selection process, construct a simple phantom to specifications, and exercise their knowledge of clinical workflows. Furthermore, the enjoyable and inexpensive nature of this project proved to attract participant interest and drive creative exploration. Mahon and Riblett have nothing to disclose; Hugo has a research agreement with Phillips Medical systems, a license agreement with Varian Medical Systems, research grants from the National Institute of Health. Authors do not have any potential conflicts of interest to disclose.

60 APPLIED LIFE SCIENCES↗

SU-F-P-48: The Quantitative Evaluation and Comparison of Image Distortion and Loss of X-Ray Images Between Anti-Scattered Grid and Moire Compensation Processing in Digital Radiography

Purpose: To quantitatively analyze the influence image processing for Moire elimination has in digital radiography by comparing the image acquired from optimized anti-scattered grid only and the image acquired from software processing paired with misaligned low-frequency grid. Methods: Special phantom, which does not create scattered radiation, was used to acquire non-grid reference images and they were acquired without any grids. A set of images was acquired with optimized grid, aligned to pixel of a detector and other set of images was acquired with misaligned low-frequency grid paired with Moire elimination processing algorithm. X-ray technique used was based on consideration to Bucky factor derived from non-grid reference images. For evaluation, we analyze by comparing pixel intensity of acquired images with grids to that of reference images. Results: When compared to image acquired with optimized grid, images acquired with Moire elimination processing algorithm showed 10 to 50% lower mean contrast value of ROI. Severe distortion of images was found with when the object’s thickness was measured at 7 or less pixels. In this case, contrast value measured from images acquired with Moire elimination processing algorithm was under 30% of that taken from reference image. Conclusion: This study shows the potential risk of Moire compensation images in diagnosis. Images acquired with misaligned low-frequency grid results in Moire noise and Moire compensation processing algorithm used to remove this Moire noise actually caused an image distortion. As a result, fractures and/or calcifications which are presented in few pixels only may not be diagnosed properly. In future work, we plan to evaluate the images acquired without grid but based on 100% image processing and the potential risks it possesses.

60 APPLIED LIFE SCIENCES↗

SU-F-R-17: Advancing Glioblastoma Multiforme (GBM) Recurrence Detection with MRI Image Texture Feature Extraction and Machine Learning

Purpose: To test the potential of early Glioblastoma Multiforme (GBM) recurrence detection utilizing image texture pattern analysis in serial MR images post primary treatment intervention. Methods: MR image-sets of six time points prior to the confirmed recurrence diagnosis of a GBM patient were included in this study, with each time point containing T1 pre-contrast, T1 post-contrast, T2-Flair, and T2-TSE images. Eight Gray-level co-occurrence matrix (GLCM) texture features including Contrast, Correlation, Dissimilarity, Energy, Entropy, Homogeneity, Sum-Average, and Variance were calculated from all images, resulting in a total of 32 features at each time point. A confirmed recurrent volume was contoured, along with an adjacent non-recurrent region-of-interest (ROI) and both volumes were propagated to all prior time points via deformable image registration. A support vector machine (SVM) with radial-basis-function kernels was trained on the latest time point prior to the confirmed recurrence to construct a model for recurrence classification. The SVM model was then applied to all prior time points and the volumes classified as recurrence were obtained. Results: An increase in classified volume was observed over time as expected. The size of classified recurrence maintained at a stable level of approximately 0.1 cm{sup 3} up to 272 days prior to confirmation. Noticeable volume increase to 0.44 cm{sup 3} was demonstrated at 96 days prior, followed by significant increase to 1.57 cm{sup 3} at 42 days prior. Visualization of the classified volume shows the merging of recurrence-susceptible region as the volume change became noticeable. Conclusion: Image texture pattern analysis in serial MR images appears to be sensitive to detecting the recurrent GBM a long time before the recurrence is confirmed by a radiologist. The early detection may improve the efficacy of targeted intervention including radiosurgery. More patient cases will be included to create a generalizable classification model applicable to a larger patient cohort. NIH R43CA183390 and R01CA188300.NSF Graduate Research Fellowship DGE-1144087.

60 APPLIED LIFE SCIENCES↗

SU-F-R-30: Interscanner Variability of Radiomics Features in Computed Tomography (CT) Using a Standard ACR Phantom

Purpose: A simple approach to investigate Interscanner variability of Radiomics features in computed tomography (CT) using a standard ACR phantom. Methods: The standard ACR phantom was scanned on CT scanners from three different manufacturers. Scanning parameters of 120 KVp, 200 mA were used while slice thickness of 3.0 mm on two scanners and 3.27 mm on third scanner was used. Three spherical regions of interest (ROI) from water, medium density and high density inserts were contoured. Ninety four Radiomics features were extracted using an in-house program. These features include shape (11), intensity (22), GLCM (26), GLZSM (11), RLM (11), and NGTDM (5) and 8 fractal dimensions features. To evaluate the Interscanner variability across three scanners, a coefficient of variation (COV) is calculated for each feature group. Each group is further classified according to the COV- by calculating the percentage of features in each of the following categories: COV less than 2%, between 2 and 10% and greater than 10%. Results: For all feature groups, similar trend was observed for three different inserts. Shape features were the most robust for all scanners as expected. 70% of the shape features had COV <2%. For intensity feature group, 2% COV varied from 9 to 32% for three scanners. All features in four groups GLCM, GLZSM, RLM and NGTDM were found to have Interscanner variability ≥2%. The fractal dimensions dependence for medium and high density inserts were similar while it was different for water inserts. Conclusion: We concluded that even for similar scanning conditions, Interscanner variability across different scanners was significant. The texture features based on GLCM, GLZSM, RLM and NGTDM are highly scanner dependent. Since the inserts of the ACR Phantom are not heterogeneous in HU values suggests that matrix based 2nd order features are highly affected by variation in noise. Research partly funded by NIH/NCI R01CA190105-01.

60 APPLIED LIFE SCIENCES↗

SU-F-R-33: Can CT and CBCT Be Used Simultaneously for Radiomics Analysis

Purpose: To investigate whether CBCT and CT can be used in radiomics analysis simultaneously. To establish a batch correction method for radiomics in two similar image modalities. Methods: Four sites including rectum, bladder, femoral head and lung were considered as region of interest (ROI) in this study. For each site, 10 treatment planning CT images were collected. And 10 CBCT images which came from same site of same patient were acquired at first radiotherapy fraction. 253 radiomics features, which were selected by our test-retest study at rectum cancer CT (ICC>0.8), were calculated for both CBCT and CT images in MATLAB. Simple scaling (z-score) and nonlinear correction methods were applied to the CBCT radiomics features. The Pearson Correlation Coefficient was calculated to analyze the correlation between radiomics features of CT and CBCT images before and after correction. Cluster analysis of mixed data (for each site, 5 CT and 5 CBCT data are randomly selected) was implemented to validate the feasibility to merge radiomics data from CBCT and CT. The consistency of clustering result and site grouping was verified by a chi-square test for different datasets respectively. Results: For simple scaling, 234 of the 253 features have correlation coefficient ρ>0.8 among which 154 features haveρ>0.9 . For radiomics data after nonlinear correction, 240 of the 253 features have ρ>0.8 among which 220 features have ρ>0.9. Cluster analysis of mixed data shows that data of four sites was almost precisely separated for simple scaling(p=1.29 * 10{sup −7}, χ{sup 2} test) and nonlinear correction (p=5.98 * 10{sup −7}, χ{sup 2} test), which is similar to the cluster result of CT data (p=4.52 * 10{sup −8}, χ{sup 2} test). Conclusion: Radiomics data from CBCT can be merged with those from CT by simple scaling or nonlinear correction for radiomics analysis.

60 APPLIED LIFE SCIENCES↗

SU-F-I-47: Optimizing Protocols for Image Quality and Dose in Abdominal CT of Large Patients

Purpose: Newer CT scanners are able to use scout views to adjust mA throughout the scan in order to achieve a given noise level. However, given constraints of radiologist preferences for kVp and rotation time, it may not be possible to achieve an acceptable noise level for large patients. A study was initiated to determine for which patients kVp and/or rotation time should be changed in order to achieve acceptable image quality. Methods: Patient scans were reviewed on two new Emergency Department scanners (Philips iCT) to identify patients over a large range of sizes. These iCTs were set with a limit of 500 mA to safeguard against a failure that might cause a CT scan to be (incorrectly) obtained at too-high mA. Scout views of these scans were assessed for both AP and LAT patient width and AP and LAT standard deviation in an ROI over the liver. Effective diameter and product of the scout standard deviations over the liver were both studied as possible metrics for identifying patients who would need kVp and/or rotation time changed. The mA used for the liver in the CT was compared to these metrics for those patients whose CT scans showed acceptable image quality. Results: Both effective diameter and product of the scout standard deviations over the liver result in similar predictions for which patients will require the kVp and/or rotation time to be changed to achieve an optimal combination of image quality and dose. Conclusion: Two mechanisms for CT technologists to determine based on scout characteristics what kVp, mA limit, and rotation time to use when DoseRight with our physicians’ preferred kVp and rotation time will not yield adequate image quality are described.

60 APPLIED LIFE SCIENCES↗

SU-F-I-59: Quality Assurance Phantom for PET/CT Alignment and Attenuation Correction

Purpose: This study utilizes a commercial PET/CT phantom to investigate two specific properties of a PET/CT system: the alignment accuracy of PET images with those from CT used for attenuation correction and the accuracy of this correction in PET images. Methods: A commercial PET/CT phantom consisting of three aluminum rods, two long central cylinders containing uniform activity, and attenuating materials such as air, water, bone and iodine contrast was scanned using a standard PET/CT protocol. Images reconstructed with 2 mm slice thickness and a 512 by 512 matrix were obtained. The center of each aluminum rod in the PET and CT images was compared to evaluate alignment accuracy. ROIs were drawn on transaxial images of the central rods at each section of attenuating material to determine the corrected activity (in BQML). BQML values were graphed as a function of slice number to provide a visual representation of the attenuation-correction throughout the whole phantom. Results: Alignment accuracy is high between the PET and CT images. The maximum deviation between the two in the axial plane is less than 1.5 mm, which is less than the width of a single pixel. BQML values measured along different sections of the large central rods are similar among the different attenuating materials except iodine contrast. Deviation of BQML values in the air and bone sections from the water section is less than 1%. Conclusion: Accurate alignment of PET and CT images is critical to ensure proper calculation and application of CT-based attenuation correction. This study presents a simple and quick method to evaluate the two with a single acquisition. As the phantom also includes spheres of increasing diameter, this could serve as a straightforward means to annually evaluate the status of a modern PET/CT system.

60 APPLIED LIFE SCIENCES↗

SU-F-J-23: Field-Of-View Expansion in Cone-Beam CT Reconstruction by Use of Prior Information

Purpose: Cone-beam CT (CBCT) has become an integral part of online patient setup in an image-guided radiation therapy (IGRT). In addition, the utility of CBCT for dose calculation has actively been investigated. However, the limited size of field-of-view (FOV) and resulted CBCT image with a lack of peripheral area of patient body prevents the reliability of dose calculation. In this study, we aim to develop an FOV expanded CBCT in IGRT system to allow the dose calculation. Methods: Three lung cancer patients were selected in this study. We collected the cone-beam projection images in the CBCT-based IGRT system (X-ray volume imaging unit, ELEKTA), where FOV size of the provided CBCT with these projections was 410 × 410 mm{sup 2} (normal FOV). Using these projections, CBCT with a size of 728 × 728 mm{sup 2} was reconstructed by a posteriori estimation algorithm including a prior image constrained compressed sensing (PICCS). The treatment planning CT was used as a prior image. To assess the effectiveness of FOV expansion, a dose calculation was performed on the expanded CBCT image with region-of-interest (ROI) density mapping method, and it was compared with that of treatment planning CT as well as that of CBCT reconstructed by filtered back projection (FBP) algorithm. Results: A posteriori estimation algorithm with PICCS clearly visualized an area outside normal FOV, whereas the FBP algorithm yielded severe streak artifacts outside normal FOV due to under-sampling. The dose calculation result using the expanded CBCT agreed with that using treatment planning CT very well; a maximum dose difference was 1.3% for gross tumor volumes. Conclusion: With a posteriori estimation algorithm, FOV in CBCT can be expanded. Dose comparison results suggested that the use of expanded CBCTs is acceptable for dose calculation in adaptive radiation therapy. This study has been supported by KAKENHI (15K08691).

60 APPLIED LIFE SCIENCES↗

SU-F-J-175: Evaluation of Metal Artifact Reduction Algorithms in Computed Tomography and Their Application to Radiation Therapy Treatment Planning

Purpose: High-Z (metal) implants in CT scans cause significant streak-like artifacts in the reconstructed dataset. This results in both inaccurate CT Hounsfield units for the tissue as well as obscuration of the target and organs at risk (OARs) for radiation therapy planning. Herein we analyze two metal artifact reduction algorithms: GE’s Smart MAR and a Metal Deletion Technique (MDT) for geometric and Hounsfield Unit (HU) accuracy. Methods: A CT-to-electron density phantom, with multiple inserts of various densities and a custom Cerrobend insert (Zeff=76.8), is utilized in this continuing study. The phantom is scanned without metal (baseline) and again with the metal insert. Using one set of projection data, reconstructed CT volumes are created with filtered-back-projection (FBP) and the MAR and the MDT algorithms. Regions-of-Interest (ROIs) are evaluated for each insert for HU accuracy; the metal insert’s Full-Width-Half-Maximum (FWHM) is used to evaluate the geometric accuracy. Streak severity is quantified with an HU error metric over the phantom volume. Results: The original FBP reconstruction has a Root-Mean-Square-Error (RMSE) of 57.55 HU (STD=29.19, range=−145.8 to +79.2) compared to baseline. The MAR reconstruction has a RMSE of 20.98 HU (STD=13.92, range=−18.3 to +61.7). The MDT reconstruction has a RMSE of 10.05 HU (STD=10.5, range=−14.8 to +18.6). FWHM for baseline=162.05; FBP=161.84 (−0.13%); MAR=162.36 (+0.19%); MDT=162.99 (+0.58%). Streak severity metric for FBP=19.73 (22.659% bad pixels); MAR=8.743 (9.538% bad); MDT=4.899 (5.303% bad). Conclusion: Image quality, in terms of HU accuracy, in the presence of high-Z metal objects in CT scans is improved by metal artifact reduction reconstruction algorithms. The MDT algorithm had the highest HU value accuracy (RMSE=10.05 HU) and best streak severity metric, but scored the worst in terms of geometric accuracy. Qualitatively, the MAR and MDT algorithms increased detectability of inserts, although there is a loss of in-plane resolution near the metallic insert.

60 APPLIED LIFE SCIENCES↗

SU-F-J-194: Development of Dose-Based Image Guided Proton Therapy Workflow

Purpose: To implement image-guided proton therapy (IGPT) based on daily proton dose distribution. Methods: Unlike x-ray therapy, simple alignment based on anatomy cannot ensure proper dose coverage in proton therapy. Anatomy changes along the beam path may lead to underdosing the target, or overdosing the organ-at-risk (OAR). With an in-room mobile computed tomography (CT) system, we are developing a dose-based IGPT software tool that allows patient positioning and treatment adaption based on daily dose distributions. During an IGPT treatment, daily CT images are acquired in treatment position. After initial positioning based on rigid image registration, proton dose distribution is calculated on daily CT images. The target and OARs are automatically delineated via deformable image registration. Dose distributions are evaluated to decide if repositioning or plan adaptation is necessary in order to achieve proper coverage of the target and sparing of OARs. Besides online dose-based image guidance, the software tool can also map daily treatment doses to the treatment planning CT images for offline adaptive treatment. Results: An in-room helical CT system is commissioned for IGPT purposes. It produces accurate CT numbers that allow proton dose calculation. GPU-based deformable image registration algorithms are developed and evaluated for automatic ROI-delineation and dose mapping. The online and offline IGPT functionalities are evaluated with daily CT images of the proton patients. Conclusion: The online and offline IGPT software tool may improve the safety and quality of proton treatment by allowing dose-based IGPT and adaptive proton treatments. Research is partially supported by Mevion Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-J-213: Feasibility Study of Using a Dual-Energy Cone Beam CT (DECBCT) in Proton Therapy Treatment Planning

Purpose: The aim of this study is to evaluate the feasibility of using a dual-energy CBCT (DECBCT) in proton therapy treatment planning to allow for accurate electron density estimation. Methods: For direct comparison, two scenarios were selected: a dual-energy fan-beam CT (high: 140 kVp, low: 80 kVp) and a DECBCT (high: 125 kVp, low: 80 kVp). A Gammex 467 tissue characterization phantom was used, including the rods of air, water, bone (B2–30% mineral), cortical bone (SB3), lung (LN-300), brain, liver and adipose. For the CBCT, Hounsfield Unit (HU) numbers were first obtained from the reconstructed images after a calibration was made based on water (=0) and air materials (=−1000). For each tissue surrogate, region-of-interest (ROI) analyses were made to derive high-energy and low-energy HU values (HUhigh and HUlow), which were subsequently used to estimate electron density based on the algorithm as previously described by Hunemohr N., et al. Parameters k1 and k2 are energy dependent and can be derived from calibration materials. Results: While for the dual-energy FBCT, the electron density is found be within +/−3% error relative to the values provided by the phantom vendor: −1.8% (water), 0.03% (lung), 1.1% (brain), −2.82% (adipose), −0.49% (liver) and −1.89% (cortical bones). While for the DECBCT, the estimation of electron density exhibits a relatively larger variation: −1.76% (water), −36.7% (lung), −1.92% (brain), −3.43% (adipose), 8.1% (liver) and 9.5% (cortical bones). Conclusion: For DECBCT, the accuracy of electron density estimation is inferior to that of a FBCT, especially for materials of either low-density (lung) or high density (cortical bone) compared to water. Such limitation arises from inaccurate HU number derivation in a CBCT. Advanced scatter-correction and HU calibration routines, as well as the deployment of photon counting CT detectors need be investigated to minimize the difference between FBCT and CBCT.

60 APPLIED LIFE SCIENCES↗

SU-F-T-94: Plan2pdf - a Software Tool for Automatic Plan Report for Philips Pinnacle TPS

Purpose: To implement an automatic electronic PDF plan reporting tool for Philips Pinnacle treatment planning system (TPS) Methods: An electronic treatment plan reporting software is developed by us to enable fully automatic PDF report from Pinnacle TPS to external EMR programs such as MOSAIQ. The tool is named “plan2pdf”. plan2pdf is implemented using Pinnacle scripts, Java and UNIX shell scripts, without any external program needed. plan2pdf supports full auto-mode and manual mode reporting. In full auto-mode, with a single mouse click, plan2pdf will generate a detailed Pinnacle plan report in PDF format, which includes customizable cover page, Pinnacle plan summary, orthogonal views through each plan POI and maximum dose point, DRR for each beam, serial transverse views captured throughout the dose grid at a user specified interval, DVH and scorecard windows. The final PDF report is also automatically bookmarked for each section above for convenient plan review. The final PDF report can either be saved on a user specified folder on Pinnacle, or it can be automatically exported to an EMR import folder via a user configured FTP service. In manual capture mode, plan2pdf allows users to capture any Pinnacle plan by full screen, individual window or rectangular ROI drawn on screen. Furthermore, to avoid possible patients’ plan mix-up during auto-mode reporting, a user conflict check feature is included in plan2pdf: it prompts user to wait if another patient is being exported by plan2pdf by another user. Results: plan2pdf is tested extensively and successfully at our institution consists of 5 centers, 15 dosimetrists and 10 physicists, running Pinnacle version 9.10 on Enterprise servers. Conclusion: plan2pdf provides a highly efficient, user friendly and clinical proven platform for all Philips Pinnacle users, to generate a detailed plan report in PDF format for external EMR systems.

60 APPLIED LIFE SCIENCES↗

SU-F-T-477: Investigation of DEFGEL Dosimetry Using MRI

Purpose: The DEFGEL dosimeter/phantom allows for the measurement of 3D dose distributions while maintaining tissue equivalence and deformability. Although DEFGEL is traditionally read out with optical CT, the use of MRI would permit the measurement of 3D dose distributions in optically interfering configurations, like while embedded in a phantom. To the knowledge of the authors, this work is the first investigation that uses MRI to measure dose distributions in DEFGEL dosimeters. Methods: The DEFGEL (6%T) formula was used to create 1 cm thick, 4.5 cm diameter cylindrical dosimeters. The dosimeters were irradiated using a Varian Clinac 21EX linac. The MRI based transverse relaxation rate (R2) of the gel was measured in a central slice of the dosimeter with a Spin-Echo (SE) pulse sequence on a 3T GE SIGNA PET/MR scanner. The R2 values were fit to a monoexponential dose response equation using in-house software (MATLAB). Results: The data was well fit using a monoexponential fit for R2 as a function of absorbed dose (R{sup 2} = 0.9997). The fitting parameters of the monoexponential fit resulted in a 0.1229 Gy{sub −1}s{sub −1} slope. The data also resulted in an average standard deviation of 1.8% for the R2 values within the evaluated ROI. Conclusion: The close fit for the dose response curve shows that a DEFGEL based dosimeter can be paired with a SE MRI acquisition. The Type A uncertainty of the MRI method shows adequate precision, while the slope of the fit curve is large enough that R2 differences between different gel doses are distinguishable. These results suggest that the gel could potentially be used in configurations where an optical readout is not viable, such as measurements with the gel dosimeter positioned inside larger or optically opaque phantoms. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

SU-F-T-581: The Effect of Scanning Orientation On New EBT-XD Film Using Vidar and Epson Scanners

Purpose: To study the effect of film scanning orientation for new EBT-XD film using Vidar and Epson scanners, compared with EBT3 films. Methods: The EBT-XD (lot#01081501) and EBT3 films (lot#11031501) were cut into 4cm×7cm pieces and each film piece was uniformly exposed to a 6MV photon beam (15×15cm{sup 2}) at 5 cm depth and 100cm SAD in polystyrene phantom, one at a time. The doses delivered were 0,2.5,5,10,20,30,40 and 50 Gy for EBT-XD films, and 0,0.5,1,2,4,8,12 and 16 Gy for EBT3 films, respectively. All films were scanned at least 16 hours after irradiation, one at a time, in portrait or landscape orientation, using a Vidar DosimetryPro Advantage Red and an Epson 10000XL scanner (red channel). Each film piece was positioned at the center of a frame (36cm×36cm) with a cutout slightly larger than the film size for scanning. The scanned data (71 dpi), were analyzed using ImageJ and the average in the ROI (3cm×3cm) of each film at the center was obtained. Results: Dose response curves (netOD vs. dose) were established and compared with EBT-XD and EBT3 film in portrait or landscape orientation using these two scanners. The portrait to landscape (P/L) ratio for each film/scanner combination was determined. The EBT-XD film is about three times less sensitive than EBT3 film. The netOD is higher for portrait than landscape orientation for all the film/scanner combinations. For EBT-XD and EBT3, the average P/L ratios are 1.02 and 1.03 using Vidar scanner, and 1.03 and 1.05 using Epson scanner (red channel), respectively. Conclusion: The effect of film scanning orientation for new EBT-XD film using Vidar Advantage Red and Epson 10000XL scanners has been studied, in comparison with EBT3 film. The portrait/landscape ratios are the lowest for EBT-XD film using Vidar Advantage Red scanner among the four film/scanner combinations.

60 APPLIED LIFE SCIENCES↗

SU-F-T-640: Feasibility of Using a Commercially Available Surface Guided Radiotherapy System with An Open-Face SRS Immobilization System

Purpose: To evaluate the inherent accuracy of using a surface guided radiotherapy system (SGRT) in the setup and monitoring of patients receiving stereotactic radiosurgery with an open-face SRS immobilization system. Methods: An anthropomorphic head phantom was set up using the Qfix Encompass SRS Immobilization System on a Varian Edge with OSMS and Varian TrueBeam with AlignRT. The phantom was positioned at 0° gantry and couch. A reference image was acquired using the SGRT system and an ROI was created over the mask opening. The couch and gantry were rotated to different combinations focusing on clinically used SRS gantry/couch combinations and those blocking the SGRT cameras. Perceived surface deviation by the SGRT system from the reference image was recorded. A Winston-Lutz test was performed on couch angles tested and used to exclude couch walkout. The deviation magnitude was calculated using translational values and rotational raw values were recorded. Results: The maximum couch walkouts were: 0.4mm (Edge) and 0.5mm (TB). Solely rotating the gantry resulted in a median couch deviation of 0.2mm and range of 0.1–0.3mm for both linacs. Only rotating the couch (0° gantry) resulted in median deviations of 0.6mm and 0.5mm with ranges of 0.3–1.0mm and 0.3–0.7mm for the Edge and TB, respectively. Combining gantry and couch rotations, the median deviations were 0.7mm and 0.9mm with ranges of 0.3–1.1mm and 0.2–1.9mm for the Edge and TB, respectively. Including all combinations, rotation, roll, and pitch median deviations ranged from 0.1–0.3° with pitch demonstrating consistently higher values and a maximum deviation of 1.0° (both linacs). Conclusion: SGRT is a reliable monitoring tool, though taking into account system fluctuations, 1mm is too restrictive a site tolerance to use with the Qfix Encompass mask. Gantry rotation has little effect on system fluctuation even with camera blockage, whereas couch rotation has a larger effect.

43 PARTICLE ACCELERATORS↗

SU-F-T-662: Feasibility Study of Fe3O4/TaOx Nano Particles as a Radiosensitizer for Radiation Therapy

Purpose: To investigate the feasibility of using multifunctional Fe{sub 3}O{sub 4}/TaOx(core / shell) nano particles developed for CT and MRI contrast agent as dose enhancing radiosensitizers. Methods: Firstly, to verify the imaging detectability of Fe{sub 3}O{sub 4}/TaOx nano particles, in-vivo tests were conducted. Approximately 600 mg/kg of 19 nm diameter Fe{sub 3}O{sub 4}/TaOx nano particles dispersed in phosphate buffered saline(PBS) were injected to ten nude Balb/c mice through the tail vein. Difference between pre- and post-injection images was analyzed by computing the pixel histogram and correlation coefficient factor using MATLAB in the user defined ROI. Secondly, to quantify the potential therapeutic enhancement with nano materials, DER (Dose Enhancement Ratio) and number of SER (Secondary Electron Ratio) were computed using TOPAS(ver.2.0 P-03) MC simulation. Results: In CT, MRI imaging, the aorta, the blood vessel, and the liver were clearly visualized after intravenous injection of Fe{sub 3}O{sub 4}/TaOx nano particles. There was large different between pre and post-injection images of Histogram data and Coefficients of correlation factor in CT and MR are 0.006, 0.060, respectively. When 70 MeV protons were irradiated for a Gold, Tantalum, TaOx, Fe{sub 3}O{sub 4}/TaOx, Fe{sub 3}O{sub 4} nano particle, DER was 2.59, 2.41, 1.68, 1.54 and 1.36 respectively. Similarly, SER increment was 2.31, 2.15, 1.56, 1.46, and 1.27 for Gold, Tantalum, TaOx, Fe{sub 3}O{sub 4}/TaOx, Fe{sub 3}O{sub 4} nano particle, respectively. Conclusion: Fe{sub 3}O{sub 4}/TaOx nano particles have potential as a multifunctional agent which enhances the accuracy in cancer detection through visualization of developed tumor lesion and increases the therapeutic effect in proton therapy. The dose enhancement with Fe{sub 3}O{sub 4}/TaOx was estimated as half of the Gold. However, tumor targeting such as combined with magnetic field may overcome the low DER. This research was supported by the NRF funded by the Ministry of Science, ICT & Future Planning (2012M3A9B6055201 and 2012R1A1A2042414), Samsung Medical Center grant[GFO1130081].

60 APPLIED LIFE SCIENCES↗