On Ba(+) production in the CRIT 2 experiment

Analysis of partical data from the CRIT 2 experiment, studying Alfven's critical ionization velocity (CIV) effect, shows that the density of newly created ions (presumably Ba(+) from the shaped-charge beam) is consistent with the increase in total plasma density measured by the independent RF plasma probe on board (Swenson et al., 1990) at the most active time period. We model this ion production using the measured electron flux data and the neutral barium model of Stenbaek-Nielsen et al. (1990a). To identify the main source mechanisms which may contribute most to the barium ionization, a simple model for the barium ion density at the payload location is developed based on Liouvilles theorem. We estimate that the electron impact ionization is responsible for 90% of the barium ion production observed by CRIT 2 in the first release and up to 45% in the second release. By employing a two-state approximation calculation (Rapp and Francis, 1962), the Ba-O(+) charge exchange cross section is found to range from about 2.0 X 10(exp -17) sq cm at a velocity of 4 km/s to 2.0 X 10(exp -15) sq cm at a velocity of 20 km/s. This result suggests that the Ba-O(+) charge exchange is probably dominant among all the non-CIV ionization processes. By considering the charge exchange process in our density model, the barrium ion densities are calculated for the two releases on CRIT II. The comparison between the model results and the observed data is found to be resonably consistent if the cross sections, as calculated above, are multiplied by 0.3 for the first release and 1.0 for the second release. Our result suggests that the charge exchange process could be the most important non-CIV ionization mechanism in the CRIT II experiment and it should be considered carefully case by case in CIV experiments.

Liou, K.↗

Pulse modulated microwave operation on large bore electron cyclotron resonance ion source with cylindrically comb-shaped magnetic fields configuration

In order to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure, the magnetic field configuration is constructed by a pair of comb-shaped magnet which has opposite polarity each other, and which cylindrically surrounds the plasma chamber. By using the pulse microwave mode operation, we aim at generation of plasma with parameters that cannot be achieved at the continuous microwave (cw) mode. The maximum beam current is obtained in the experimental condition of the pulse width 100-200 {mu}s at the duty ratio 40%-50%. According to probe measurements of the ECR plasma, it is found the electron density in the pulse mode is larger than that in the cw mode, while the electron temperatures in the pulse mode were lower than that in the cw mode. These indirect evidences cause to enhance ion beams in the pulse mode operation, and then suggest a spread of operation windows for plasma parameters suitable to production of molecular or cluster ions.

43 PARTICLE ACCELERATORS↗

Production of electron cyclotron resonance plasma by using multifrequencies microwaves and active beam profile control on a large bore electron cyclotron resonance ion source with permanent magnets

A new concept on magnetic field with all magnets on plasma production and confinement has been proposed to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure. The magnetic field configuration is constructed by a pair of magnets assembly, i.e., comb-shaped magnet which cylindrically surrounds the plasma chamber. The resonance zones corresponding to the fundamental ECR for 2.45 GHz and 11-13 GHz frequencies are constructed at different positions. The profiles of the plasma parameters in the ECR ion source are different from each frequency of microwave. Large bore extractor is set at the opposite side against the microwave feeds. It is found that differences of their profiles also appear at those of ion beam profiles. We conducted to launch simultaneously multiplex frequencies microwaves controlled individually, and tried to control the profiles of the plasma parameters and then those of extracted ion beam.

43 PARTICLE ACCELERATORS↗

Precise micromotion compensation of a tilted ion chain

Excess micromotion can be a substantial source of errors in trapped-ion based quantum processors and clocks due to the sensitivity of the internal states of the ion to external fields and motion. This problem can be fixed by compensating background electric fields in order to position ions at the RF node and minimize their driven micromotion. Here we describe techniques for compensating ion chains in scalable surface ion traps. These traps are capable of cancelling stray electric fields with fine spatial resolution in order to compensate multiple closely spaced ions due to their large number of relatively small control electrodes. We demonstrate a technique that compensates an ion chain to better than 5 V/m and within 0.1 degrees of chain rotation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-consistent modeling of radio-frequency plasma generation in stellarators

A self-consistent model of radio-frequency (RF) plasma generation in stellarators in the ion cyclotron frequency range is described. The model includes equations for the particle and energy balance and boundary conditions for Maxwell’s equations. The equation of charged particle balance takes into account the influx of particles due to ionization and their loss via diffusion and convection. The equation of electron energy balance takes into account the RF heating power source, as well as energy losses due to the excitation and electron-impact ionization of gas atoms, energy exchange via Coulomb collisions, and plasma heat conduction. The deposited RF power is calculated by solving the boundary problem for Maxwell’s equations. When describing the dissipation of the energy of the RF field, collisional absorption and Landau damping are taken into account. At each time step, Maxwell’s equations are solved for the current profiles of the plasma density and plasma temperature. The calculations are performed for a cylindrical plasma. The plasma is assumed to be axisymmetric and homogeneous along the plasma column. The system of balance equations is solved using the Crank-Nicholson scheme. Maxwell’s equations are solved in a one-dimensional approximation by using the Fourier transformation along the azimuthal and longitudinal coordinates. Results of simulations of RF plasma generation in the Uragan-2M stellarator by using a frame antenna operating at frequencies lower than the ion cyclotron frequency are presented. The calculations show that the slow wave generated by the antenna is efficiently absorbed at the periphery of the plasma column, due to which only a small fraction of the input power reaches the confinement region. As a result, the temperature on the axis of the plasma column remains low, whereas at the periphery it is substantially higher. This leads to strong absorption of the RF field at the periphery via the Landau mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrity Monitoring of Mercury Discharge Lamps

Mercury discharge lamps are critical in many trapped ion frequency standard applications. An integrity monitoring system can be implemented using end-of-life signatures observed in operational mercury discharge lamps, making it possible to forecast imminent failure and to take action to mitigate the consequences (such as switching to a redundant system). Mercury lamps are used as a source of 194-nm ultraviolet radiation for optical pumping and state selection of mercury trapped ion frequency standards. Lamps are typically fabricated using 202Hg distilled into high-purity quartz, or other 194-nm transmitting material (e.g., sapphire). A buffer gas is also placed into the bulb, typically a noble gas such as argon, neon, or krypton. The bulbs are driven by strong RF fields oscillating at .200 MHz. The lamp output may age over time by two internal mechanisms: (1) the darkening of the bulb that attenuates light transmission and (2) the loss of mercury due to migration or chemical interactions with the bulb surface. During fabrication, excess mercury is placed into a bulb, so that the loss rate is compensated with new mercury emanating from a cool tip or adjacent reservoir. The light output is nearly constant or varies slightly at a constant rate for many months/years until the mercury source is depleted. At this point, the vapor pressure abruptly falls and the total light output and atomic clock SNR (signal-to-noise ratio) decrease. After several days to weeks, the light levels decrease to a point where the atomic clock SNR is no longer sufficient to stay in lock, or the lamp self-extinguishes. This signature has been observed in four separate end-of-life lamp failures while operating in the Deep Space Network (DSN). A simple integrator circuit can observe and document steady-state lamp behavior. When the light levels drop over a predetermined time interval by a specified amount (e.g., 20 percent), an alarm is set. For critical operational applications, such as the DSN or in space flight, this warning provides notice that a failure may be imminent, and for operators or control algorithm to take action.

Tjoelker, Robert L.↗

Final Technical Report for Grant No. DE-FC02-01ER54648, SciDAC Center for Simulation of Wave-Plasma Interactions

Harnessing the energy that is released in fusion reactions would provide a safe and abundant source of power to meet the growing energy needs of the world population. The next step toward the development of fusion as a practical energy source is the construction of ITER, a device capable of producing and controlling the high performance plasma required for self-sustaining fusion reactions, or “burning” plasma. The input power required to drive the ITER plasma into the burning regime will be supplied primarily with a combination of external power from radio frequency waves in the ion cyclotron range of frequencies and energetic ions from neutral beam injection sources, in addition to internally-generated Ohmic heating from the induced plasma current that also serves to create the magnetic equilibrium for the discharge. Since the success of the ITER project depends critically on the ability to create and maintain burning plasma conditions, it is absolutely necessary to have physics-based models that can accurately simulate the RF processes that affect the dynamical evolution of the ITER discharge. The Center for Simulation of Wave-Plasma Interactions (CSWPI) is a multi-institutional collaboration that has conducted ongoing research aimed at developing: (1) Coupled core-to-edge simulations that will lead to an increased understanding of parasitic losses of the applied RF power in the boundary plasma between the RF antenna and the core plasma; (2) Development of models for core interactions of RF waves with energetic electrons and ions (including fusion alpha particles and fast neutral beam ions) that include a more accurate representation of the particle dynamics in the combined equilibrium and wave fields; and (3) Development of improved algorithms that will take advantage of massively parallel computing platforms at the petascale level and beyond to achieve the needed physics, resolution, and/or statistics to address these issues. This research reported in this final technical report is focused on further verification and validation of simulation models for interactions of RF waves with energetic particles in the core with a long term goal of assessing their readiness for inclusion in integrated modeling frameworks and utilizing the world’s largest supercomputers to quantitatively predict the detailed electric field structure in the vicinity of the launching structures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of NIO1 construction

The NIO1 (Negative Ion Optimization phase 1) project consists of a multiaperture negative ion source mounted on a 60 kV accelerating column; up to 9 beamlets (15 mA H{sup -} each one) arranged in 3x3 matrix with 14 mm spacing can be extracted. The moderate size and the modular concept make some relative rotation of the source magnetic filter and the electrodes possible, so that the effect of crossed and aligned field can be easily compared. Other goals of source experimental program are emittance (and beam profile) measurement at several distances (for simulation code validation), testing of diagnostic components and of radiofrequency coupling. A full set of construction drawing was completed; also the Fast Emittance Scanner (FES) and its vacuum chambers were built (four mounting positions are reserved to FES). Some low power rf matching boxes were developed for a test plasma, approximately half the source size. A cesium oven compatible with NIO1 is being also developed; by using some industrial standard 100 W heaters (with a proper driver) a careful control of temperature is planned.

43 PARTICLE ACCELERATORS↗

Ion beams extraction and measurements of plasma parameters on a multi-frequencies microwaves large bore ECRIS with permanent magnets

We have developed an all-permanent magnet large bore electron cyclotron resonance ion source (ECRIS) for broad ion beam processing. The cylindrically comb-shaped magnetic field configuration is adopted for efficient plasma production and good magnetic confinement. To compensate for disadvantages of fixed magnetic configuration, a traveling wave tube amplifier (TWTA) is used. In the comb-shaped ECRIS, it is difficult to achieve controlling ion beam profiles in the whole inside the chamber by using even single frequency-controllable TWTA (11-13GHz), because of large bore size with all-magnets. We have tried controlling profiles of plasma parameters and then those of extracted ion beams by launching two largely different frequencies simultaneously, i.e., multi-frequencies microwaves. Here we report ion beam profiles and corresponding plasma parameters under various experimental conditions, dependence of ion beams against extraction voltages, and influence of different electrode positions on the electron density profile.

43 PARTICLE ACCELERATORS↗

Assessment of a field-aligned ICRF antenna

Impurity contamination and localized heat loads associated with ion cyclotron range of frequency (ICRF) antenna operation are among the most challenging issues for ICRF utilization.. Another challenge is maintaining maximum coupled power through plasma variations including edge localized modes (ELMs) and confinement transitions. Here, we report on an experimental assessment of a field aligned (FA) antenna with respect to impurity contamination, impurity sources, RF enhanced heat flux and load tolerance. In addition, we compare the modification of the scrape of layer (SOL) plasma potential of the FA antenna to a conventional, toroidally aligned (TA) antenna, in order to explore the underlying physics governing impurity contamination linked to ICRF heating. The FA antenna is a 4-strap ICRF antenna where the current straps and antenna enclosure sides are perpendicular to and the Faraday screen rods are parallel to the total magnetic field. In principle, alignment with respect to the total magnetic field minimizes integrated E∥ (electric field along a magnetic field line) via symmetry. Consistent with expectations, we observed that the impurity contamination and impurity source at the FA antenna are reduced compared to the TA antenna. In both L and H-mode discharges, the radiated power is 20–30% lower for a FA-antenna heated discharge than a discharge heated with the TA-antennas. Further we observe that the fraction of RF energy deposited upon the antenna is less than 0.4 % of the total injected RF energy in dipole phasing. The total deposited energy increases significantly when the FA antenna is operated in monopole phasing. The FA antenna also exhibits an unexpected load tolerance for ELMs and confinement transitions compared to the TA antennas. However, inconsistent with expectations, we observe RF induced plasma potentials to be nearly identical for FA and TA antennas when operated in dipole phasing. In monopole phasing, the FA antenna has the highest plasma potentials and poor heating efficiency despite calculations indicating low integrated E∥. In mode conversion heating scenario, no core waves were detected in the plasma core indicating poor wave penetration. For monopole phasing, simulations suggest the antenna spectrum is peaked at very short wavelength and full wave simulations show the short wavelength has poor wave penetration to the plasma core.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modified Penning-Malmberg Trap for Storing Antiprotons

A modified Penning-Malmberg trap that could store a small cloud of antiprotons for a relatively long time (weeks) has been developed. This trap is intended for use in research on the feasibility of contemplated future matter/antimatter-annihilation systems as propulsion sources for spacecraft on long missions. This trap is also of interest in its own right as a means of storing and manipulating antiprotons for terrestrial scientific experimentation. The use of Penning-Malmberg traps to store antiprotons is not new. What is new here is the modified trap design, which utilizes state-of-the-art radiofrequency (RF) techniques, including ones that, heretofore, have been used in radio-communication applications but not in iontrap applications. A basic Penning-Malmberg trap includes an evacuated round tube that contains or is surrounded by three or more collinear tube electrodes. A steady axial magnetic field that reaches a maximum at the geometric center of the tube is applied by an external source, and DC bias voltages that give rise to an electrostatic potential that reaches a minimum at the center are applied to the electrodes. The combination of electric and magnetic fields confines the charged particles (ions or electrons) for which it was designed to a prolate spheroidal central region. However, geometric misalignments and the diffusive cooling process prevent the steady fields of a basic Penning- Malmberg trap from confining the particles indefinitely. In the modified Penning-Malmberg trap, the loss of antiprotons is reduced or eliminated by use of a "rotating-wall" RF stabilization scheme that also heats the antiproton cloud to minimize loss by matter/antimatter annihilation. The scheme involves the superposition of a quadrupole electric field that rotates about the cylindrical axis at a suitably chosen radio frequency. The modified Penning-Malmberg trap (see Figure 1) includes several collinear sets of electrodes inside a tubular vacuum chamber. Each set comprises either a single metal tube or else a tube that is segmented into four electrodes that subtend equal angles about the cylindrical axis. The output of an RF signal generator is fed through a 90 hybrid coupler and then through two baluns to generate four replicas of the signal at relative phase shifts of 0 , 90 , 180 , and 270 (see Figure 2). These signal replicas are fed through 6-dB directional couplers, then via coaxial cables to the vacuum chamber. The signal is then routed to a phase cancellation network, which filters out the drive signal with the difference representing the plasma interaction. Inside the vacuum chamber, twisted-pair wires feed the signals from the coaxial cables to the four electrodes of each segmented electrode tube.

Sims, William H.↗

Pulsed Multiple Reaction Monitoring Approach to Enhancing Sensitivity of a Tandem Quadrupole Mass Spectrometer

Liquid chromatography (LC)-triple quadrupole mass spectrometers operating in a Multiple Reaction Monitoring (MRM) mode are increasingly used for quantitative analysis of low abundance analytes in highly complex biochemical matrices. After development and selection of optimum MRM transition, sensitivity and data quality limitations are largely related to mass spectral peak interferences from sample or matrix constituents and statistical limitations at low number of ions reaching the detector. Herein, we report a new approach to enhancing MRM sensitivity by converting the continuous stream of ions from the ion source into a pulsed ion beam through the use of an Ion Funnel Trap (IFT). Evaluation of the pulsed MRM approach was performed with a tryptic digest of Shewanella oneidensis strain MR-1 spiked with several reference peptides. The sensitivity improvement observed with the IFT coupled to the triple quadrupole instrument is based on several unique features. First, ion accumulation in the radio frequency (RF) ion trap facilitates improved droplet desolvation, which is manifested in the reduced background ion noise at the detector. Second, signal amplitude for a given transition is enhanced because of an order-of-magnitude increase in the ion charge density per unit time compared to a continuous mode of operation. Third, signal detection at the full duty cycle is obtained, as the trap use eliminates dead times between transitions, which are inevitable with continuous ion streams. In comparison with the conventional approach, the pulsed MRM signals showed up to 5-fold enhanced peak amplitude and 2-3 fold reduced chemical background, resulting in an improvement in the limit of detection (LOD) by a factor of ~ 4 to ~ 8.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced polarization of low pressure 3 He through metastability exchange optical pumping at high field

Here, we report high steady-state nuclear polarization of 1 torr 3 He gas nuclei via metastability exchange optical pumping at magnetic fields above 2 T. The introduction of highly polarized 3 He gas into Brookhaven’s Electron Beam Ion Source would enable a new, polarized 3 He ion source for use at the Relativistic Heavy Ion Collider and a future Electron–Ion Collider facility. By adapting recent developments in high field metastability exchange optical pumping for higher pressure gas, we have successfully polarized 1 torr 3 He sealed cells in the EBIS solenoid. Through careful manipulation of the RF discharge parameters, polarizations above 80% were attained at 2, 3 and 4 T, with 89% being reached at 3 T with a 664 s relaxation time.

43 PARTICLE ACCELERATORS↗

Phase Rotation Scheme To Combine an RF Technique With Laser-Plasma Interaction For Real Applications Of Laser-Produced Ions

A phase rotation scheme of laser-produced ions from a solid target by the application of a synchronized RF electric voltage with a pulsed laser has been experimentally investigated with the use of a 100 TW laser, J-KAREN at JAEA, KPSI. Up to now, energy peaks of up to around 2.0 MeV have been created with a FWHM of 2.6% with good reproducibility using a two-gap resonator of a quarter wave length with the same frequency as the source laser (approx80 MHz). It is also found that the position of the peak can be well controlled by adjusting the relative phase between the RF electric field and the laser, which is very promising for real applications of such laser-produced protons. In order to also apply such a phase rotation system for higher energy protons (<200 MeV), a scheme to use a small linear accelerator (LINAC) with multi-gaps is proposed as a phase rotator. With multi-gap structure, alternating focusing between longitudinal and transverse degrees of freedoms can be realized. From the point of compactness and realizing a small focused spot, however, a scheme combining separate quadrupole magnets just before and after the RF cavity excited with the Wideroee mode, might be more effective. The scheme presented here will realize laser-produced ions (protons) with good reproducibility by combining with RF technology.

43 PARTICLE ACCELERATORS↗

On the Life Expectancy of High-Power CW magnetrons for Superconducting Accelerators*

Utilization of the high-power CW magnetrons as RF sources in SRF accelerators was proposed in a number of works, e.g., [1, 2]. But typically, the CW high-power magnetrons are designed as RF sources for industrial heating, and the lifetime of the tubes is not the first priority as it is required for high-energy accelerators. The high-power CW magnetrons use cathodes made of pure tungsten. The emission properties of the tungsten cathodes are not deteriorated much by electron and ion bombardment, but the latter causes sputtering of the cathode in the magnetron crossed fields. The sputtered cathode material covers the magnetron interior. That leads to sparks and discharges in a magnetron limiting its lifetime. Thus, the life expectancy estimates are highly important for application of CW magnetrons in SRF accelerator projects.

43 PARTICLE ACCELERATORS↗

Adherence of ion beam sputter deposited metal films on H-13 steel

An electron bombardment argon ion source was used to sputter deposit 17 different metal and metal oxide films ranging in thickness from 1 to 8 micrometers on H-13 steel substrates. The film adherence to the substrate surface was measured using a tensile test apparatus. Comparisons in bond strength were made between ion beam, ion plating, and RF deposited films. A protective coating to prevent heat checking in H-13 steel dies used for aluminum die casting was studied. The results of exposing the coated substrates to temperatures up to 700 degrees are presented.

Mirtich, M. J.↗

Status of the ITER Ion Cyclotron H&CD

The ITER Ion Cyclotron Heating and Current Drive system (IC H&CD) is designed to deliver 20MW to a broad range of plasma scenarios between 40 and 55MHz, during very long pulses. It consists of two broadband equatorial port plug antennas, their pre-matching and matching systems, transmission lines, Radio Frequency (RF) Sources and High Voltage Power Supplies. The overall project schedule has been revised and agreed by ITER Council; it re-integrates the second antenna and its power supplies in construction baseline and sets the dates for progressive installation with DT phase planned in 2035. Recent progress on ICRF subsystems is reported, covering design evolution, qualification of test articles and specific R&D results in domestic agencies, suppliers, associated laboratories and IO.

Agarwal, Rohit↗

Simultaneous analysis of ion and electron heat transport by power modulation in JET

Heating power modulation experiments using ion cyclotron resonance heating (ICRH) in the {sup 3}He minority scheme have been performed in the JET tokamak to investigate heat transport properties. This RF scheme provides a dominant localized ion heating, but also some electron heating, and therefore both ion and electron heat channels were modulated. This allows us to carry out a simultaneous transport analysis of ion and electron heat transport channels, including transient transport phenomena. This also provides an experimental assessment of the ICRH heat sources of the {sup 3}He scheme. The modulation approach, so far widely used for electron transport studies, has been validated for ion heat transport in these experiments and yields results on stiffness and threshold of the ion temperature gradient (ITG)-driven ion heat transport. The results for the electron channel demonstrate the importance of the ITG-driven, off-diagonal, contribution to electron heat transport in plasmas with significant ion heating.

43 PARTICLE ACCELERATORS↗