Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RF SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Recent Beam Stability Analysis for the EIC

This document summarizes work done in WBS 6.02.02 during FY23. Additional details can be found in the EIC overview paper presented at IPAC’23 [1], and the references therein. Progress has been made in the ESR and HSR lattice design, dynamic aperture optimization, and the RCS lattice design. The impedance and Collective effects are progressing and include the impedance optimization process of the vacuum systems for RCS, HSR, and ESR; collective effects studies; collective effects and beam-beam interaction; coupled bunch instabilities and the crab cavities; low-level RF feedback system design and beam-ion instability. The reversed phasing RF system has been numerically studied for the ESR to mitigate Robinson instability and demonstrate reliable stable beam operation. Various codes, including C++, SPACE [2], ELEGANT [3], and Mbtrack2 [4] have been employed to benchmark the results. The simulation of HSR bunch splitting with beam loading has been performed at 275 GeV energy. The evaluation of Beam Position Monitors aimed to validate their expected performance, with the primary objective being to verify their accuracy. Calculations of Electron Polarization in the ESR, RCS, and HSR are showing good progress. In the RCS, preliminary studies indicate excellent polarization transmission over intrinsic spin resonances, achieving over 90% transmission with improved performance compared to the previous lattice. Preliminary simulations in the ESR indicate encouraging results in minimizing depolarization and improving equilibrium polarization.

43 PARTICLE ACCELERATORS↗

A New Internal Optical Profilometry System for Characterization of RF Cavity Surfaces - CYCLOPS

Jefferson Lab has received and is commissioning a new interferometric optical profilometer specifically designed to provide internal surface mapping of elliptical rf cavities. The CavitY CaLibrated Optical Profilometry System -CYCLOPS - provides better than 2 µm lateral resolution and 0.1 µm surface height resolution of programmatically selected locations on the interior surface of multi-cell cavities. The system is being used to provide detailed characterization of surface topographic evolution as a function of applied surface treatments and to investigate particular localized defects. We also intend to use the system for 3D mapping of actual interior rf surface geometry for feedback to structure design model and fabrication tooling. First uses will be illustrated. CYCLOPS was developed and fabricated by MicroDynamics Inc., Woodstock, GA, USA.

Reece, Charles↗

RF MEMS and Their Applications in NASA's Space Communication Systems

Radio frequency (RF) and microwave communication systems rely on frequency, amplitude, and phase control circuits to efficiently use the available spectrum. Phase control circuits are required for electronically scanning phase array antennas that enable radiation pattern shaping, scanning, and hopping. Two types of phase shifters, which are the phase control circuits, are most often used. The first is comprised of two circuits with different phase characteristics such as two transmission lines of different lengths or a high pass and low pass filter and a switch that directs the RF power through one of the two circuits. Alternatively, a variable capacitor, or varactor, is used to change the effective electrical path length of a transmission line, which changes the phase characteristics. Filter banks are required for the diplexer at the front end of wide band communication satellites. These filters greatly increase the size and mass of the RF/microwave systems, but smaller diplexers may be made with a low loss varactor or a group of capacitors, a switch and an inductor.

Williams, W. Daniel↗

High-temperature metal purification using a compact, portable rf heating and levitation system on the wake shield

The potential use of a compact, battery-operated rf levitator and heating system to purify high-temperature melting materials in space is described. The wake shield now being fabricated for the Space Vacuum Epitaxy Center will provide an Ultra-high vacuum (10(exp -14) Torr hydrogen, 10(exp -14) Torr helium, 10(exp -30) Torr oxygen). The use of the wake shield to purify Nb, Ti, W, Ir, and other metals to a purity level not achievable on earth is described.

Hahs, C. A.↗

Radio frequency ion source operated with field effect transistor based radio frequency system

Characteristics of radio frequency (RF) plasma production are investigated using a field effect transistor inverter power supply as an RF wave source. With the frequency of around 0.3 MHz, an electron density over 10{sup 18} m{sup -3} is produced in argon plasma. Although lower densities are obtained in hydrogen plasma, it drastically increased up to 5x10{sup 18} m{sup -3} with an axial magnetic field of around 100 G applied in the driver region. Effects of the magnetic field and gas pressure are investigated in the RF produced plasma with the frequency of several hundred kilohertz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DIRECT RF SAMPLING BASED LLRF CONTROL SYSTEM FOR C-BAND LINEAR ACCELERATOR

Low Level RF (LLRF) control systems of linear accel- erators (LINACs) are typically implemented with hetero- dyne based architectures, which have complex analog RF mixers for up and down conversion. The Gen 3 Radio Fre- quency System-on-Chip (RFSoC) device from AMD Xilinx integrates data converters with maximum RF frequency of 6 GHz. This enables direct RF sampling of C-band LLRF signal typically operated at 5.712 GHz without any analogue mixers, which can significantly simplify the system architec- ture. The data converters sample RF signals in higher order Nyquist zones and then up or down convert digitally by the integrated data path in RFSoC. The closed-loop feedback control firmware implemented in FPGA integrated in RF- SoC can process the base-band signal from the ADC data path and calculate the updated phase and amplitude to be up- mixed by the DAC data path. We have developed a C-band LLRF control RFSoC platform with direct RF sampling, which targets Cool Copper Collider (𝐶3) and other C or S band LINAC research and development projects. In this paper, the architecture of the platform will be described. We have optimized the configuration of the data converter and characterized performance of them with RF pulses. The test results for some of the key performance parameters for the LLRF platform with our custom solid-state amplifier, such as phase and amplitude stability, will be discussed in this paper.

Liu, C↗

Loran digital phase-locked loop and RF front-end system error analysis

An analysis of the system performance of the digital phase locked loops (DPLL) and RF front end that are implemented in the MINI-L4 Loran receiver is presented. Three of the four experiments deal with the performance of the digital phase locked loops. The other experiment deals with the RF front end and DPLL system error which arise in the front end due to poor signal to noise ratios. The ability of the DPLLs to track the offsets is studied.

Mccall, D. L.↗

RF Matching Feedback Control Systems on the JET ITER-Like Antenna

Ion Cyclotron Resonance Frequency (ICRF) antennas achieve maximum power transfer from RF generator to plasma load by establishing an impedance match. The JET ITER-Like Antenna (ILA) consists of 4 mutually coupled resonators that need to be matched simultaneously and whose resonant states need to be accurately controlled by several available actuators to couple maximum power and to achieve optimal ELM resilience. The operation of the matching system is described. Experimental operation revealed some phenomena and sensitivities that did not surface from simulation alone and that should be taken into account for the design of future ICRF antennae systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-power test of a C-band linear accelerating structure with an RFSoC-based LLRF system

Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure and to compensate for the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analog rf mixers, heterodyne-based architectures, and discrete data converters. There are multiple rf signals from each of the rf stations, so the number of rf channels required increases rapidly with multiple rf stations. With a large number of rf channels, the footprint, component cost, and system complexity of the LLRF hardware will increase significantly. To meet the design goals of being compact and affordable for future accelerators, we have designed the next-generation LLRF (NG-LLRF) with a higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs rf mixing digitally. Further, the NG-LLRF has been characterized in loopback mode to evaluate the performance of the system and has also been tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C 3 ) with a peak rf power level up to 16.45 MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15°, which are considerably better than the requirements of C 3 . The rf signals from the different stages of the accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes, which could be useful for controlling some of the rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed, and discussed.

47 OTHER INSTRUMENTATION↗

Electron bunch energy and phase feed-forward stabilization system for the Mark V RF-linac free-electron laser

An amplitude and phase compensation system has been developed and tested at the University of Hawai'i for the optimization of the RF drive system to the Mark V free-electron laser. Temporal uniformity of the RF drive is essential to the generation of an electron beam suitable for optimal free-electron laser performance and the operation of an inverse Compton scattering x-ray source. The design of the RF measurement and compensation system is described in detail and the results of RF phase compensation are presented. Performance of the free-electron laser was evaluated by comparing the measured effects of phase compensation with the results of a computer simulation. Finally, preliminary results are presented for the effects of amplitude compensation on the performance of the complete system.

43 PARTICLE ACCELERATORS↗

Part 1: Detailed Electromagnetic Design of an Integrated and Compact 1.3 GHZ Superconducting Radio Frequency (SRF) Electron

There exists a need for compact, reliable, high-power electron sources for applications including those in water treatment, basic science, defense, and security. There also exists a need for compact electron-beam based light and power sources of various power levels and at different frequencies (mm-wave to gamma rays) for applications also in the fields of basic science, industry, and defense and security. Today’s examples of high-average-power electron sources are neither very compact nor highly efficient. The same may be said for many of the electron-beam based light sources operated worldwide for myriad of applications. Recent breakthroughs in superconducting (SC) materials technology, radio-frequency (RF) power systems, specialized cathodes, and RF cavity designs offer ways to overcome the above-mentioned shortcomings. In this report, all these new features are integrated in a comprehensive design into one promising concept for a compact superconducting RF (SRF) high-average power electron linear accelerator. This design is capable of 5-50 kW average electron beam power and continuous wave operation with the corresponding electron beam energy up to 10 MeV.

43 PARTICLE ACCELERATORS↗

Overview of the Communications and Intelligent Systems Division at the NASA Glenn Research Center

NASA's plans for advancing aeronautics and space exploration requires optimization of current capabilities and development of new ones to support its mission. A key requirement associated with these efforts is the constant upgrading and optimization of communication systems. This presentation will provide a brief overview of NASA efforts, with emphasis on those being performed at the NASA Glenn Research Center, to develop communications technologies and systems in support of NASA aerospace communications needs. Status of specific technology examples in the area of cognitive communication systems, Advanced RF Technologies, Networks, and Systems Architectures will be presented and their impact in the overall scheme of needs will be discussed. In addition, cross- cutting technologies which enable sensing, control and communications technologies to perform in extreme environments as well as non-destructive evaluations techniques for vehicle health monitoring and related purposes will be presented.

Miranda, Felix A.↗

R&D ERL: Cryogenic System

The ERL cryogenic system will supply cooling to a super-conducting RF (SCRF) gun and the 5-cell super-conducting RF cavity system that need to be held cold at 2K. The engineering of the cavity cryomodules were carried out by AES in collaboration with BNL. The 2K superfluid bath is produced by pumping on the bath using a sub-atmospheric warm compression system. The cryogenic system makes use of mainly existing equipment relocated from other facilities: a 300W 4.5K coldbox, an 45 g/s screw compressor, a 3800 liter liquid helium storage dewar, a 170 m{sup 3} warm gas storage tank, and a 40,000 liter vertical low pressure liquid nitrogen storage dewar. An existing wet expander obtained from another facility has been added to increase the plant capacity. In order to deliver the required 3 to 4 bar helium to the cryomodules while using up stored liquid capacity at low pressure, a new subcooler will be installed to function as the capacity transfer device. A 2K to 4K recovery heat exchanger is also implemented for each cryomodule to recover refrigeration below 4K, thus maximizing 2K cooling capacity with the given sub-atmospheric pump. No 4K-300K refrigeration recovery is implemented at this time of the returning sub-atmospheric cold vapor, hence the 2K load appears as a liquefaction1 load on the cryogenic plant. A separate LN2 cooling loop supplies liquid nitrogen to the superconducting gun's cathode tip.

43 PARTICLE ACCELERATORS↗

Modeling for the phased injector upgrade for 12 GeV CEBAF

As a follow on to the 12 GeV upgrade to the Continuous Electron Beam Accelerator Facility, the front end of the DC photo-gun-based injector has gone through a phased upgrade. The first phase focused on the beamline between the gun and the RF chopper system, and the second phase addresses the beamline after the RF chopper system including replacing the capture section and quarter cryomodule with a new booster module containing a 2-cell and 7-cell cavity string. Throughout the design process, we maintained and developed three models, one for the existing injector and one for each of the upgrade phases. With these models, we evaluated proposed hardware upgrades, evaluated and determined optimized beamline element positions, developed buncher voltage requirements, and settings for optimal injector running. In this paper, we will describe the models and results from these various studies and provide a brief summary of Phase 1 commissioning.

Kazimi, R.↗

X-BAND TRAVELING WAVE RF DEFLECTOR STRUCTURES

Design studies on the X-Band transverse RF deflectors operating at HEM{sub ll} mode have been made for two different applications. One is for beam measurement of time-sliced emittance and slice energy spread for the upgraded LCLS project, its optimization in RF efficiency and system design are carefully considered. Another is to design an ultra-fast RF kicker in order to pick up single bunches from the bunch-train of the B-factory storage ring. The challenges are to obtain very short structure filling time with high RF group velocity and good RF efficiency with reasonable transverse shunt impedance. Its RF system will be discussed.

43 PARTICLE ACCELERATORS↗

High temperature metal purification using a compact portable rf heating and levitation system on the wake shield

The Wake Shield Facility (WSF) can provide an ideal vacuum environment for the purification of high temperature metals in space. The Modular Electromagnetic Levitator (MEL), will provide the opportunity to study undercooling of metals in space and allow to determine material properties in space. The battery powered rf levitation and heating system developed for the MEL demonstrated efficiency of 36 percent. This system is being considered to purify metals at temperatures below 3000 C.

Hahs, C. A.↗

SU-F-J-142: Proposed Method to Broaden Inclusion Potential of Patients Able to Use the Calypso Tracking System in Prostate Radiotherapy

Purpose: To introduce a non-standard method of patient setup, using BellyBoard immobilization, to better utilize the localization and tracking potential of an RF-beacon system with EBRT for prostate cancer. Methods: An RF-beacon phantom was imaged using a wide bore CT scanner, both in a standard level position and with a known rotation (4° pitch and 7.5° yaw). A commercial treatment planning system (TPS) was used to determine positional coordinates of each beacon, and the centroid of the three beacons for both setups. For each setup at the Linac, kV AP and Rt Lateral images were obtained. A full characterization of the RF-beacon system in clinical mode was completed for various beacons’ array-to-centroid distances, which includes vertical, lateral, and longitudinal offset data, as well as pitch and yaw offset measurements for the tilted phantom. For the single patient who has been setup using the proposed BellyBoard method, a supine simulation was first obtained. When abdominal protrusion was found to be exceeding the limits of the RF-Beacon system through distance-based analysis in the TPS, the patient is re-simulated prone with the BellyBoard. Array to centroid distance is measured again in the TPS, and if found to be within the localization or tracking region it is applied. Results: Characterization of limitations for the RF-beacon system in clinical mode showed acceptable consistency of offset determination for phantom setup accuracy. The nonstandard patient setup method reduced the beacons’ centroid-to-array distance by 8.32cm, from 25.13cm to 16.81cm; completely out of tracking range (greater than 20cm) to within setup tracking range (less than 20cm). Conclusion: Using the RF-beacon system in combination with this novel patient setup can allow patients who would otherwise not be candidates for beacon enhanced EBRT to now be able to benefit from the reduced PTV margins of this treatment method.

60 APPLIED LIFE SCIENCES↗